CVE-2022-31257 (GCVE-0-2022-31257)
Vulnerability from cvelistv5 – Published: 2022-07-12 10:06 – Updated: 2024-08-03 07:11
VLAI?
Summary
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.31), Mendix Applications using Mendix 8 (All versions < V8.18.18), Mendix Applications using Mendix 9 (All versions < V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.12). In case of access to an active user session in an application that is built with an affected version, it’s possible to change that user’s password bypassing password validations within a Mendix application. This could allow to set weak passwords.
Severity ?
No CVSS data available.
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Mendix Applications using Mendix 7 |
Affected:
All versions < V7.23.31
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T07:11:39.898Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Mendix Applications using Mendix 7",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.23.31"
}
]
},
{
"product": "Mendix Applications using Mendix 8",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V8.18.18"
}
]
},
{
"product": "Mendix Applications using Mendix 9",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.14.0"
}
]
},
{
"product": "Mendix Applications using Mendix 9 (V9.12)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.12.2"
}
]
},
{
"product": "Mendix Applications using Mendix 9 (V9.6)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V9.6.12"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). In case of access to an active user session in an application that is built with an affected version, it\u2019s possible to change that user\u2019s password bypassing password validations within a Mendix application. This could allow to set weak passwords."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-07-12T10:06:42",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-31257",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Mendix Applications using Mendix 7",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.23.31"
}
]
}
},
{
"product_name": "Mendix Applications using Mendix 8",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V8.18.18"
}
]
}
},
{
"product_name": "Mendix Applications using Mendix 9",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.14.0"
}
]
}
},
{
"product_name": "Mendix Applications using Mendix 9 (V9.12)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.12.2"
}
]
}
},
{
"product_name": "Mendix Applications using Mendix 9 (V9.6)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V9.6.12"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). In case of access to an active user session in an application that is built with an affected version, it\u2019s possible to change that user\u2019s password bypassing password validations within a Mendix application. This could allow to set weak passwords."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284: Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-31257",
"datePublished": "2022-07-12T10:06:43",
"dateReserved": "2022-05-20T00:00:00",
"dateUpdated": "2024-08-03T07:11:39.898Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"7.0.0\", \"versionEndExcluding\": \"7.32.31\", \"matchCriteriaId\": \"A25B23A6-DFBF-46B4-BF0C-5819189EB009\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"8.0.0\", \"versionEndExcluding\": \"8.18.18\", \"matchCriteriaId\": \"8471E2B7-B69D-4D3F-AA7C-B953F28E6D6E\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"9.6.0\", \"versionEndExcluding\": \"9.6.12\", \"matchCriteriaId\": \"DB45CC2F-34B6-4824-8DFC-E571C3F1E873\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"9.12.0\", \"versionEndExcluding\": \"9.12.2\", \"matchCriteriaId\": \"11365A01-2860-4627-8947-1FDB3DC0C454\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"9.13.0\", \"versionEndExcluding\": \"9.14.0\", \"matchCriteriaId\": \"F6942480-6F30-4C74-81DB-ED498BCA42F2\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). In case of access to an active user session in an application that is built with an affected version, it\\u2019s possible to change that user\\u2019s password bypassing password validations within a Mendix application. This could allow to set weak passwords.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en las aplicaciones de Mendix usando Mendix 7 (Todas las versiones anteriores a V7.23.31), las aplicaciones de Mendix usando Mendix 8 (Todas las versiones anteriores a V8.18.18), las aplicaciones de Mendix usando Mendix 9 (Todas las versiones anteriores a V9.14.0), las aplicaciones de Mendix usando Mendix 9 (versi\\u00f3n V9.12) (Todas las versiones anteriores a V9.12.2), las aplicaciones de Mendix usando Mendix 9 (versi\\u00f3n V9.6) (Todas las versiones anteriores a V9.6.12). En caso de acceder a una sesi\\u00f3n de usuario activa en una aplicaci\\u00f3n construida con una versi\\u00f3n afectada, es posible cambiar la contrase\\u00f1a de ese usuario omitiendo las comprobaciones de contrase\\u00f1a dentro de una aplicaci\\u00f3n Mendix. Esto podr\\u00eda permitir establecer contrase\\u00f1as d\\u00e9biles\"}]",
"id": "CVE-2022-31257",
"lastModified": "2024-11-21T07:04:14.230",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:P/A:N\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2022-07-12T10:15:10.653",
"references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-284\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-Other\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2022-31257\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-07-12T10:15:10.653\",\"lastModified\":\"2024-11-21T07:04:14.230\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions \u003c V7.23.31), Mendix Applications using Mendix 8 (All versions \u003c V8.18.18), Mendix Applications using Mendix 9 (All versions \u003c V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions \u003c V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions \u003c V9.6.12). In case of access to an active user session in an application that is built with an affected version, it\u2019s possible to change that user\u2019s password bypassing password validations within a Mendix application. This could allow to set weak passwords.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en las aplicaciones de Mendix usando Mendix 7 (Todas las versiones anteriores a V7.23.31), las aplicaciones de Mendix usando Mendix 8 (Todas las versiones anteriores a V8.18.18), las aplicaciones de Mendix usando Mendix 9 (Todas las versiones anteriores a V9.14.0), las aplicaciones de Mendix usando Mendix 9 (versi\u00f3n V9.12) (Todas las versiones anteriores a V9.12.2), las aplicaciones de Mendix usando Mendix 9 (versi\u00f3n V9.6) (Todas las versiones anteriores a V9.6.12). En caso de acceder a una sesi\u00f3n de usuario activa en una aplicaci\u00f3n construida con una versi\u00f3n afectada, es posible cambiar la contrase\u00f1a de ese usuario omitiendo las comprobaciones de contrase\u00f1a dentro de una aplicaci\u00f3n Mendix. Esto podr\u00eda permitir establecer contrase\u00f1as d\u00e9biles\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:P/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0.0\",\"versionEndExcluding\":\"7.32.31\",\"matchCriteriaId\":\"A25B23A6-DFBF-46B4-BF0C-5819189EB009\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.0.0\",\"versionEndExcluding\":\"8.18.18\",\"matchCriteriaId\":\"8471E2B7-B69D-4D3F-AA7C-B953F28E6D6E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.6.0\",\"versionEndExcluding\":\"9.6.12\",\"matchCriteriaId\":\"DB45CC2F-34B6-4824-8DFC-E571C3F1E873\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.12.0\",\"versionEndExcluding\":\"9.12.2\",\"matchCriteriaId\":\"11365A01-2860-4627-8947-1FDB3DC0C454\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mendix:mendix:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"9.13.0\",\"versionEndExcluding\":\"9.14.0\",\"matchCriteriaId\":\"F6942480-6F30-4C74-81DB-ED498BCA42F2\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-433782.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…