All the vulnerabilites related to WAGO - PFC200 G2 750-821x-xxx-xxx
cve-2024-41971
Vulnerability from cvelistv5
Published
2024-11-18 09:04
Modified
2024-11-18 15:19
Severity ?
EPSS score ?
Summary
WAGO: Arbitrary File Overwrite in Multiple Devices
References
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-41971", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-18T15:19:07.273651Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-18T15:19:34.134Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "CC100 0751-9x01", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC100 G2 0750-811x-xxxx-xxxx", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC200 G2 750-821x-xxx-xxx", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-420x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-430x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-520x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-530x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-620x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-630x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Edge Controller 0752-8303/8000-0002", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Diego Giubertoni" }, { "lang": "en", "type": "reporter", "user": "00000000-0000-4000-9000-000000000000", "value": "Nozomi Networks" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A low privileged remote attacker can overwrite an arbitrary file on the filesystem leading to a DoS and data loss.\u003cbr\u003e" } ], "value": "A low privileged remote attacker can overwrite an arbitrary file on the filesystem leading to a DoS and data loss." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-18T09:04:42.052Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://cert.vde.com/en/advisories/VDE-2024-047" } ], "source": { "advisory": "VDE-2024-047", "defect": [ "CERT@VDE#641658" ], "discovery": "UNKNOWN" }, "title": "WAGO: Arbitrary File Overwrite in Multiple Devices", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2024-41971", "datePublished": "2024-11-18T09:04:42.052Z", "dateReserved": "2024-07-25T09:07:31.465Z", "dateUpdated": "2024-11-18T15:19:34.134Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-41972
Vulnerability from cvelistv5
Published
2024-11-18 09:04
Modified
2024-11-19 14:54
Severity ?
EPSS score ?
Summary
WAGO: Arbitrary File Overwrite Leading to Privileged File Read in Multiple Devices
References
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-41972", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-19T14:53:48.536484Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-19T14:54:08.033Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "CC100 0751-9x01", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC100 G2 0750-811x-xxxx-xxxx", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC200 G2 750-821x-xxx-xxx", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-420x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-430x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-520x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-530x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-620x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-630x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Edge Controller 0752-8303/8000-0002", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Diego Giubertoni" }, { "lang": "en", "type": "reporter", "user": "00000000-0000-4000-9000-000000000000", "value": "Nozomi Networks" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A low privileged remote attacker can\u0026nbsp;overwrite an arbitrary file on the filesystem which\u0026nbsp;may lead to an arbitrary file read with root privileges.\u003cbr\u003e" } ], "value": "A low privileged remote attacker can\u00a0overwrite an arbitrary file on the filesystem which\u00a0may lead to an arbitrary file read with root privileges." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-35", "description": "CWE-35 Path Traversal: \u0027.../...//\u0027", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-18T09:04:56.284Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://cert.vde.com/en/advisories/VDE-2024-047" } ], "source": { "advisory": "VDE-2024-047", "defect": [ "CERT@VDE#641658" ], "discovery": "UNKNOWN" }, "title": "WAGO: Arbitrary File Overwrite Leading to Privileged File Read in Multiple Devices", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2024-41972", "datePublished": "2024-11-18T09:04:56.284Z", "dateReserved": "2024-07-25T09:07:31.466Z", "dateUpdated": "2024-11-19T14:54:08.033Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-41974
Vulnerability from cvelistv5
Published
2024-11-18 09:05
Modified
2024-11-18 15:12
Severity ?
EPSS score ?
Summary
WAGO: BACNet Service Property Modification Due to Permission Misconfiguration in Multiple Devices
References
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-41974", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-18T15:12:08.030082Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-18T15:12:34.402Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "CC100 0751-9x01", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC100 G2 0750-811x-xxxx-xxxx", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC200 G2 750-821x-xxx-xxx", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-420x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-430x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-520x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-530x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-620x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-630x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Edge Controller 0752-8303/8000-0002", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Diego Giubertoni" }, { "lang": "en", "type": "reporter", "user": "00000000-0000-4000-9000-000000000000", "value": "Nozomi Networks" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A low privileged remote attacker\u0026nbsp;may modify the BACNet service properties due to incorrect permission assignment for critical resources which may lead to a DoS limited to BACNet communication.\u003cbr\u003e\u003cbr\u003e" } ], "value": "A low privileged remote attacker\u00a0may modify the BACNet service properties due to incorrect permission assignment for critical resources which may lead to a DoS limited to BACNet communication." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.1, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-732", "description": "CWE-732 Incorrect Permission Assignment for Critical Resource", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-18T09:05:32.043Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://cert.vde.com/en/advisories/VDE-2024-047" } ], "source": { "advisory": "VDE-2024-047", "defect": [ "CERT@VDE#641658" ], "discovery": "UNKNOWN" }, "title": "WAGO: BACNet Service Property Modification Due to Permission Misconfiguration in Multiple Devices", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2024-41974", "datePublished": "2024-11-18T09:05:32.043Z", "dateReserved": "2024-07-25T09:07:31.466Z", "dateUpdated": "2024-11-18T15:12:34.402Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-41969
Vulnerability from cvelistv5
Published
2024-11-18 09:04
Modified
2024-11-18 09:04
Severity ?
EPSS score ?
Summary
WAGO: CODESYS V3 Configuration Authentication Bypass in Multiple Devices
References
Impacted products
{ "containers": { "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "CC100 0751-9x01", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC100 G2 0750-811x-xxxx-xxxx", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC200 G2 750-821x-xxx-xxx", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-420x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-430x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-520x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-530x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-620x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-630x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Edge Controller 0752-8303/8000-0002", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC100 G1 0750-810x/xxxx-xxxx", "vendor": "WAGO", "versions": [ { "lessThan": "3.10.11", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC200 G1 750-820x-xxx-xxx", "vendor": "WAGO", "versions": [ { "lessThan": "3.10.11", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Diego Giubertoni" }, { "lang": "en", "type": "reporter", "user": "00000000-0000-4000-9000-000000000000", "value": "Nozomi Networks" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A low privileged remote attacker may\u0026nbsp;modify the configuration of the CODESYS V3 service through a missing authentication vulnerability which could lead to full system access and/or DoS.\u0026nbsp;\u003cbr\u003e" } ], "value": "A low privileged remote attacker may\u00a0modify the configuration of the CODESYS V3 service through a missing authentication vulnerability which could lead to full system access and/or DoS." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-18T09:04:13.691Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://cert.vde.com/en/advisories/VDE-2024-047" } ], "source": { "advisory": "VDE-2024-047", "defect": [ "CERT@VDE#641658" ], "discovery": "UNKNOWN" }, "title": "WAGO: CODESYS V3 Configuration Authentication Bypass in Multiple Devices", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2024-41969", "datePublished": "2024-11-18T09:04:13.691Z", "dateReserved": "2024-07-25T09:07:31.464Z", "dateUpdated": "2024-11-18T09:04:13.691Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-41973
Vulnerability from cvelistv5
Published
2024-11-18 09:05
Modified
2024-11-18 15:13
Severity ?
EPSS score ?
Summary
WAGO: Remote Arbitrary File Write with Root Privileges in multiple Devices
References
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-41973", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-18T15:13:35.584257Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-18T15:13:57.685Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "CC100 0751-9x01", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC100 G2 0750-811x-xxxx-xxxx", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC200 G2 750-821x-xxx-xxx", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-420x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-430x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-520x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-530x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-620x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-630x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Edge Controller 0752-8303/8000-0002", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Diego Giubertoni" }, { "lang": "en", "type": "reporter", "user": "00000000-0000-4000-9000-000000000000", "value": "Nozomi Networks" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A low privileged remote attacker can\u0026nbsp;specify an arbitrary file on the filesystem which\u0026nbsp;may lead to an arbitrary file writes with root privileges.\u003cbr\u003e" } ], "value": "A low privileged remote attacker can\u00a0specify an arbitrary file on the filesystem which\u00a0may lead to an arbitrary file writes with root privileges." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-35", "description": "CWE-35 Path Traversal: \u0027.../...//\u0027", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-18T09:05:15.892Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://cert.vde.com/en/advisories/VDE-2024-047" } ], "source": { "advisory": "VDE-2024-047", "defect": [ "CERT@VDE#641658" ], "discovery": "UNKNOWN" }, "title": "WAGO: Remote Arbitrary File Write with Root Privileges in multiple Devices", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2024-41973", "datePublished": "2024-11-18T09:05:15.892Z", "dateReserved": "2024-07-25T09:07:31.466Z", "dateUpdated": "2024-11-18T15:13:57.685Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-41968
Vulnerability from cvelistv5
Published
2024-11-18 09:03
Modified
2024-11-19 14:56
Severity ?
EPSS score ?
Summary
WAGO: Docker Settings Manipulation in Multiple Devices
References
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-41968", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-19T14:56:16.336634Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-19T14:56:53.627Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "CC100 0751-9x01", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC100 G2 0750-811x-xxxx-xxxx", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC200 G2 750-821x-xxx-xxx", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-420x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-430x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-520x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-530x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-620x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-630x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Edge Controller 0752-8303/8000-0002", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC100 G1 0750-810x/xxxx-xxxx", "vendor": "WAGO", "versions": [ { "lessThan": "3.10.11", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC200 G1 750-820x-xxx-xxx", "vendor": "WAGO", "versions": [ { "lessThan": "3.10.11", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Diego Giubertoni" }, { "lang": "en", "type": "reporter", "user": "00000000-0000-4000-9000-000000000000", "value": "Nozomi Networks" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A low privileged remote attacker may modify the docker settings setup of the device, leading to a limited DoS.\u0026nbsp;\u003cbr\u003e" } ], "value": "A low privileged remote attacker may modify the docker settings setup of the device, leading to a limited DoS." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.4, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-18T09:03:20.948Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://cert.vde.com/en/advisories/VDE-2024-047" } ], "source": { "advisory": "VDE-2024-047", "defect": [ "CERT@VDE#641658" ], "discovery": "UNKNOWN" }, "title": "WAGO: Docker Settings Manipulation in Multiple Devices", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2024-41968", "datePublished": "2024-11-18T09:03:20.948Z", "dateReserved": "2024-07-25T09:07:31.463Z", "dateUpdated": "2024-11-19T14:56:53.627Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-41970
Vulnerability from cvelistv5
Published
2024-11-18 09:04
Modified
2024-11-18 15:17
Severity ?
EPSS score ?
Summary
WAGO: Unauthorized Diagnostic Data Exposure in Multiple Devices
References
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-41970", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-18T15:17:05.082537Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-18T15:17:28.237Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "CC100 0751-9x01", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC100 G2 0750-811x-xxxx-xxxx", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC200 G2 750-821x-xxx-xxx", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-420x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-430x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-520x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-530x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-620x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-630x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Edge Controller 0752-8303/8000-0002", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Diego Giubertoni" }, { "lang": "en", "type": "reporter", "user": "00000000-0000-4000-9000-000000000000", "value": "Nozomi Networks" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A low privileged remote attacker\u0026nbsp;may gain access to forbidden diagnostic data due to incorrect permission assignment for critical resources.\u003cbr\u003e" } ], "value": "A low privileged remote attacker\u00a0may gain access to forbidden diagnostic data due to incorrect permission assignment for critical resources." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-732", "description": "CWE-732 Incorrect Permission Assignment for Critical Resource", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-18T09:04:27.334Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://cert.vde.com/en/advisories/VDE-2024-047" } ], "source": { "advisory": "VDE-2024-047", "defect": [ "CERT@VDE#641658" ], "discovery": "UNKNOWN" }, "title": "WAGO: Unauthorized Diagnostic Data Exposure in Multiple Devices", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2024-41970", "datePublished": "2024-11-18T09:04:27.334Z", "dateReserved": "2024-07-25T09:07:31.465Z", "dateUpdated": "2024-11-18T15:17:28.237Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-41967
Vulnerability from cvelistv5
Published
2024-11-18 09:03
Modified
2024-11-18 15:22
Severity ?
EPSS score ?
Summary
WAGO: Boot Mode Manipulation in Multiple Devices
References
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-41967", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-11-18T15:22:03.669949Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-18T15:22:26.251Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "CC100 0751-9x01", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC100 G2 0750-811x-xxxx-xxxx", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC200 G2 750-821x-xxx-xxx", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-420x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-430x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-520x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-530x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-620x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "TP600 0762-630x/8000-000x", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Edge Controller 0752-8303/8000-0002", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "4.5.10 (FW27)", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC100 G1 0750-810x/xxxx-xxxx", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "3.10.11", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC200 G1 750-820x-xxx-xxx", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "3.10.11", "status": "affected", "version": "0.0.0", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "finder", "user": "00000000-0000-4000-9000-000000000000", "value": "Diego Giubertoni" }, { "lang": "en", "type": "reporter", "user": "00000000-0000-4000-9000-000000000000", "value": "Nozomi Networks" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "A low privileged remote attacker\u0026nbsp;may modify the boot mode configuration setup of the device, leading to modification of the firmware upgrade process or a denial-of-service attack.\u003cbr\u003e" } ], "value": "A low privileged remote attacker\u00a0may modify the boot mode configuration setup of the device, leading to modification of the firmware upgrade process or a denial-of-service attack." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-11-18T09:03:57.513Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://cert.vde.com/en/advisories/VDE-2024-047" } ], "source": { "advisory": "VDE-2024-047", "defect": [ "CERT@VDE#641658" ], "discovery": "UNKNOWN" }, "title": "WAGO: Boot Mode Manipulation in Multiple Devices", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2024-41967", "datePublished": "2024-11-18T09:03:57.513Z", "dateReserved": "2024-07-25T09:07:31.463Z", "dateUpdated": "2024-11-18T15:22:26.251Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }