Search criteria
62 vulnerabilities found for Parasolid V34.0 by Siemens
CVE-2023-30795 (GCVE-0-2023-30795)
Vulnerability from cvelistv5 – Published: 2023-08-08 09:20 – Updated: 2024-10-11 22:16
VLAI?
Summary
A vulnerability has been identified in JT Open (All versions < V11.4), JT Utilities (All versions < V13.4), Parasolid V34.0 (All versions < V34.0.253), Parasolid V34.1 (All versions < V34.1.243), Parasolid V35.0 (All versions < V35.0.177), Parasolid V35.1 (All versions < V35.1.073). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT Open |
Affected:
All versions < V11.4
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:37:15.439Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-001569.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-30795",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T22:16:06.900938Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T22:16:31.109Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT Open",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V11.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "JT Utilities",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.253"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.243"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.177"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.1.073"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT Open (All versions \u003c V11.4), JT Utilities (All versions \u003c V13.4), Parasolid V34.0 (All versions \u003c V34.0.253), Parasolid V34.1 (All versions \u003c V34.1.243), Parasolid V35.0 (All versions \u003c V35.0.177), Parasolid V35.1 (All versions \u003c V35.1.073). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-08T09:20:19.964Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-001569.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-30795",
"datePublished": "2023-08-08T09:20:19.964Z",
"dateReserved": "2023-04-18T09:19:57.943Z",
"dateUpdated": "2024-10-11T22:16:31.109Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-25140 (GCVE-0-2023-25140)
Vulnerability from cvelistv5 – Published: 2023-02-14 10:37 – Updated: 2025-03-19 18:53
VLAI?
Summary
A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.254), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.1 (All versions < V35.1.150), Solid Edge SE2022 (All versions < V222.0MP12). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V34.0 |
Affected:
All versions < V34.0.254
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:18:35.846Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-25140",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-19T18:53:27.859268Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-19T18:53:35.636Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.254"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.170"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.1.150"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V222.0MP12"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V34.0 (All versions \u003c V34.0.254), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Parasolid V35.1 (All versions \u003c V35.1.150), Solid Edge SE2022 (All versions \u003c V222.0MP12). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-14T09:31:55.102Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-25140",
"datePublished": "2023-02-14T10:37:08.574Z",
"dateReserved": "2023-02-03T08:06:30.685Z",
"dateUpdated": "2025-03-19T18:53:35.636Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-47936 (GCVE-0-2022-47936)
Vulnerability from cvelistv5 – Published: 2023-02-14 10:36 – Updated: 2025-03-20 20:07
VLAI?
Summary
A vulnerability has been identified in JT Open (All versions < V11.2.3.0), JT Utilities (All versions < V13.2.3.0), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.1 (All versions < V35.1.150). The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT Open |
Affected:
All versions < V11.2.3.0
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T15:02:36.549Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-47936",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-20T20:07:21.772715Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-20T20:07:30.206Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT Open",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V11.2.3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "JT Utilities",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.170"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.1.150"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT Open (All versions \u003c V11.2.3.0), JT Utilities (All versions \u003c V13.2.3.0), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Parasolid V35.1 (All versions \u003c V35.1.150). The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-15T09:24:56.841Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-47936",
"datePublished": "2023-02-14T10:36:21.369Z",
"dateReserved": "2022-12-23T11:29:16.433Z",
"dateUpdated": "2025-03-20T20:07:30.206Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-46346 (GCVE-0-2022-46346)
Vulnerability from cvelistv5 – Published: 2022-12-13 00:00 – Updated: 2024-08-03 14:31
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19071)
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.264
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:31:45.864Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.264"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.170"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V222.0MP12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2023",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V223.0Update2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19071)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-14T09:31:11.475Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-46346",
"datePublished": "2022-12-13T00:00:00",
"dateReserved": "2022-11-30T00:00:00",
"dateUpdated": "2024-08-03T14:31:45.864Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-46349 (GCVE-0-2022-46349)
Vulnerability from cvelistv5 – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:42
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19384)
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.264
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:31:45.951Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-46349",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:21:12.567451Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:42:27.034Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.264"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.170"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V222.0MP12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2023",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V223.0Update2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19384)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-14T09:31:14.921Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-46349",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2022-11-30T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:42:27.034Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-46345 (GCVE-0-2022-46345)
Vulnerability from cvelistv5 – Published: 2022-12-13 00:00 – Updated: 2024-08-03 14:31
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.264
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:33.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "33.1.264",
"status": "affected",
"version": "33.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:solid_edge:se2022:-:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "solid_edge",
"vendor": "siemens",
"versions": [
{
"lessThan": "v223.0",
"status": "affected",
"version": "se2022",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:34.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "34.1.242",
"status": "affected",
"version": "34.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:35.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.0.170",
"status": "affected",
"version": "35.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:34.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "34.0.252",
"status": "affected",
"version": "34.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-46345",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:00:20.745055Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-05T19:22:59.367Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:31:46.241Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.264"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.170"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V222.0MP12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2023",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V223.0Update2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-14T09:31:10.275Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-46345",
"datePublished": "2022-12-13T00:00:00",
"dateReserved": "2022-11-30T00:00:00",
"dateUpdated": "2024-08-03T14:31:46.241Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-46347 (GCVE-0-2022-46347)
Vulnerability from cvelistv5 – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:42
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19079)
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.264
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:31:45.791Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-46347",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:21:20.520359Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:42:43.444Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.264"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.170"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V222.0MP12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2023",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V223.0Update2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19079)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-14T09:31:12.594Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-46347",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2022-11-30T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:42:43.444Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-46348 (GCVE-0-2022-46348)
Vulnerability from cvelistv5 – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:42
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19383)
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.264
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:31:46.340Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-46348",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:21:16.601521Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:42:35.733Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.264"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.170"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V222.0MP12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2023",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V223.0Update2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19383)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-14T09:31:13.727Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-46348",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2022-11-30T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:42:35.733Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-39157 (GCVE-0-2022-39157)
Vulnerability from cvelistv5 – Published: 2022-11-08 00:00 – Updated: 2025-04-21 13:47
VLAI?
Summary
A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.0 (All versions >= V34.0.252 < V34.0.254), Parasolid V34.1 (All versions < V34.1.242), Parasolid V34.1 (All versions >= V34.1.242 < V34.1.244), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.0 (All versions >= V35.0.170 < V35.0.184), Simcenter Femap (All versions < V2023.1). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17745)
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V34.0 |
Affected:
All versions < V34.0.252
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T11:10:32.613Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853037.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-39157",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:22:35.932896Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:47:13.547Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V34.0.252 \u003c V34.0.254"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V34.1.242 \u003c V34.1.244"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.170"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V35.0.170 \u003c V35.0.184"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Femap",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2023.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.0 (All versions \u003e= V34.0.252 \u003c V34.0.254), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V34.1 (All versions \u003e= V34.1.242 \u003c V34.1.244), Parasolid V35.0 (All versions \u003c V35.0.170), Parasolid V35.0 (All versions \u003e= V35.0.170 \u003c V35.0.184), Simcenter Femap (All versions \u003c V2023.1). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17745)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-15T09:24:49.998Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853037.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-39157",
"datePublished": "2022-11-08T00:00:00.000Z",
"dateReserved": "2022-09-01T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:47:13.547Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43397 (GCVE-0-2022-43397)
Vulnerability from cvelistv5 – Published: 2022-11-08 00:00 – Updated: 2025-04-21 13:46
VLAI?
Summary
A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Simcenter Femap (All versions < V2023.1). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17854)
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V34.0 |
Affected:
All versions < V34.0.252
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:32:57.387Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853037.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43397",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:22:12.468907Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:46:27.727Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.170"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Femap",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2023.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Simcenter Femap (All versions \u003c V2023.1). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17854)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-15T09:24:50.974Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853037.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-43397",
"datePublished": "2022-11-08T00:00:00.000Z",
"dateReserved": "2022-10-18T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:46:27.727Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-39156 (GCVE-0-2022-39156)
Vulnerability from cvelistv5 – Published: 2022-09-13 09:41 – Updated: 2024-08-03 11:10
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18196)
Severity ?
No CVSS data available.
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.262
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T11:10:32.600Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.262"
}
]
},
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
},
{
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.161"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
},
{
"product": "Simcenter Femap V2022.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.1.3"
}
]
},
{
"product": "Simcenter Femap V2022.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.2.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18196)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-13T09:41:10",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-39156",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V33.1.262"
}
]
}
},
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
}
},
{
"product_name": "Parasolid V34.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.0.252"
}
]
}
},
{
"product_name": "Parasolid V34.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.1.242"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V35.0.161"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.1.3"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.2.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18196)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-39156",
"datePublished": "2022-09-13T09:41:10",
"dateReserved": "2022-09-01T00:00:00",
"dateUpdated": "2024-08-03T11:10:32.600Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-39155 (GCVE-0-2022-39155)
Vulnerability from cvelistv5 – Published: 2022-09-13 09:41 – Updated: 2024-08-03 11:10
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18192)
Severity ?
No CVSS data available.
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.262
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T11:10:32.610Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.262"
}
]
},
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
},
{
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.161"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
},
{
"product": "Simcenter Femap V2022.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.1.3"
}
]
},
{
"product": "Simcenter Femap V2022.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.2.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18192)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-13T09:41:09",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-39155",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V33.1.262"
}
]
}
},
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
}
},
{
"product_name": "Parasolid V34.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.0.252"
}
]
}
},
{
"product_name": "Parasolid V34.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.1.242"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V35.0.161"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.1.3"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.2.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18192)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-39155",
"datePublished": "2022-09-13T09:41:09",
"dateReserved": "2022-09-01T00:00:00",
"dateUpdated": "2024-08-03T11:10:32.610Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-39154 (GCVE-0-2022-39154)
Vulnerability from cvelistv5 – Published: 2022-09-13 09:41 – Updated: 2024-08-03 11:10
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18188)
Severity ?
No CVSS data available.
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.262
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T11:10:32.551Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.262"
}
]
},
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
},
{
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.161"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
},
{
"product": "Simcenter Femap V2022.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.1.3"
}
]
},
{
"product": "Simcenter Femap V2022.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.2.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18188)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-13T09:41:08",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-39154",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V33.1.262"
}
]
}
},
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
}
},
{
"product_name": "Parasolid V34.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.0.252"
}
]
}
},
{
"product_name": "Parasolid V34.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.1.242"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V35.0.161"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.1.3"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.2.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18188)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-39154",
"datePublished": "2022-09-13T09:41:09",
"dateReserved": "2022-09-01T00:00:00",
"dateUpdated": "2024-08-03T11:10:32.551Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-39153 (GCVE-0-2022-39153)
Vulnerability from cvelistv5 – Published: 2022-09-13 09:41 – Updated: 2024-08-03 11:10
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18187)
Severity ?
No CVSS data available.
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.262
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T11:10:32.564Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.262"
}
]
},
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
},
{
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.161"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
},
{
"product": "Simcenter Femap V2022.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.1.3"
}
]
},
{
"product": "Simcenter Femap V2022.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.2.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18187)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-13T09:41:08",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-39153",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V33.1.262"
}
]
}
},
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
}
},
{
"product_name": "Parasolid V34.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.0.252"
}
]
}
},
{
"product_name": "Parasolid V34.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.1.242"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V35.0.161"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.1.3"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.2.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18187)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-39153",
"datePublished": "2022-09-13T09:41:08",
"dateReserved": "2022-09-01T00:00:00",
"dateUpdated": "2024-08-03T11:10:32.564Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-39152 (GCVE-0-2022-39152)
Vulnerability from cvelistv5 – Published: 2022-09-13 09:41 – Updated: 2024-08-03 11:10
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17740)
Severity ?
No CVSS data available.
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.262
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T11:10:32.670Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.262"
}
]
},
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
},
{
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.161"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
},
{
"product": "Simcenter Femap V2022.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.1.3"
}
]
},
{
"product": "Simcenter Femap V2022.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.2.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17740)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-13T09:41:07",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-39152",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V33.1.262"
}
]
}
},
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
}
},
{
"product_name": "Parasolid V34.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.0.252"
}
]
}
},
{
"product_name": "Parasolid V34.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.1.242"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V35.0.161"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.1.3"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.2.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17740)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-39152",
"datePublished": "2022-09-13T09:41:07",
"dateReserved": "2022-09-01T00:00:00",
"dateUpdated": "2024-08-03T11:10:32.670Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-30795 (GCVE-0-2023-30795)
Vulnerability from nvd – Published: 2023-08-08 09:20 – Updated: 2024-10-11 22:16
VLAI?
Summary
A vulnerability has been identified in JT Open (All versions < V11.4), JT Utilities (All versions < V13.4), Parasolid V34.0 (All versions < V34.0.253), Parasolid V34.1 (All versions < V34.1.243), Parasolid V35.0 (All versions < V35.0.177), Parasolid V35.1 (All versions < V35.1.073). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT Open |
Affected:
All versions < V11.4
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:37:15.439Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-001569.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-30795",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-11T22:16:06.900938Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-11T22:16:31.109Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT Open",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V11.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "JT Utilities",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.4"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.253"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.243"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.177"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.1.073"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT Open (All versions \u003c V11.4), JT Utilities (All versions \u003c V13.4), Parasolid V34.0 (All versions \u003c V34.0.253), Parasolid V34.1 (All versions \u003c V34.1.243), Parasolid V35.0 (All versions \u003c V35.0.177), Parasolid V35.1 (All versions \u003c V35.1.073). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-08T09:20:19.964Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-001569.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-30795",
"datePublished": "2023-08-08T09:20:19.964Z",
"dateReserved": "2023-04-18T09:19:57.943Z",
"dateUpdated": "2024-10-11T22:16:31.109Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-25140 (GCVE-0-2023-25140)
Vulnerability from nvd – Published: 2023-02-14 10:37 – Updated: 2025-03-19 18:53
VLAI?
Summary
A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.254), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.1 (All versions < V35.1.150), Solid Edge SE2022 (All versions < V222.0MP12). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V34.0 |
Affected:
All versions < V34.0.254
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T11:18:35.846Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-25140",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-19T18:53:27.859268Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-19T18:53:35.636Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.254"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.170"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.1.150"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V222.0MP12"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V34.0 (All versions \u003c V34.0.254), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Parasolid V35.1 (All versions \u003c V35.1.150), Solid Edge SE2022 (All versions \u003c V222.0MP12). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-14T09:31:55.102Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-25140",
"datePublished": "2023-02-14T10:37:08.574Z",
"dateReserved": "2023-02-03T08:06:30.685Z",
"dateUpdated": "2025-03-19T18:53:35.636Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-47936 (GCVE-0-2022-47936)
Vulnerability from nvd – Published: 2023-02-14 10:36 – Updated: 2025-03-20 20:07
VLAI?
Summary
A vulnerability has been identified in JT Open (All versions < V11.2.3.0), JT Utilities (All versions < V13.2.3.0), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.1 (All versions < V35.1.150). The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process.
Severity ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | JT Open |
Affected:
All versions < V11.2.3.0
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T15:02:36.549Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-47936",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-20T20:07:21.772715Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-20T20:07:30.206Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "JT Open",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V11.2.3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "JT Utilities",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2.3.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.170"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.1.150"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT Open (All versions \u003c V11.2.3.0), JT Utilities (All versions \u003c V13.2.3.0), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Parasolid V35.1 (All versions \u003c V35.1.150). The affected application contains a stack overflow vulnerability while parsing specially crafted JT files. This could allow an attacker to execute code in the context of the current process."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-15T09:24:56.841Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-47936",
"datePublished": "2023-02-14T10:36:21.369Z",
"dateReserved": "2022-12-23T11:29:16.433Z",
"dateUpdated": "2025-03-20T20:07:30.206Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-46346 (GCVE-0-2022-46346)
Vulnerability from nvd – Published: 2022-12-13 00:00 – Updated: 2024-08-03 14:31
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19071)
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.264
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:31:45.864Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.264"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.170"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V222.0MP12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2023",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V223.0Update2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19071)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-14T09:31:11.475Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-46346",
"datePublished": "2022-12-13T00:00:00",
"dateReserved": "2022-11-30T00:00:00",
"dateUpdated": "2024-08-03T14:31:45.864Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-46349 (GCVE-0-2022-46349)
Vulnerability from nvd – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:42
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19384)
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.264
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:31:45.951Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-46349",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:21:12.567451Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:42:27.034Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.264"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.170"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V222.0MP12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2023",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V223.0Update2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19384)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-14T09:31:14.921Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-46349",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2022-11-30T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:42:27.034Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-46345 (GCVE-0-2022-46345)
Vulnerability from nvd – Published: 2022-12-13 00:00 – Updated: 2024-08-03 14:31
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.264
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:33.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "33.1.264",
"status": "affected",
"version": "33.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:solid_edge:se2022:-:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "solid_edge",
"vendor": "siemens",
"versions": [
{
"lessThan": "v223.0",
"status": "affected",
"version": "se2022",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:34.1:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "34.1.242",
"status": "affected",
"version": "34.1",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:35.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "35.0.170",
"status": "affected",
"version": "35.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:siemens:parasolid:34.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "parasolid",
"vendor": "siemens",
"versions": [
{
"lessThan": "34.0.252",
"status": "affected",
"version": "34.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-46345",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T13:00:20.745055Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-05T19:22:59.367Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:31:46.241Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.264"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.170"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V222.0MP12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2023",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V223.0Update2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19070)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-14T09:31:10.275Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-46345",
"datePublished": "2022-12-13T00:00:00",
"dateReserved": "2022-11-30T00:00:00",
"dateUpdated": "2024-08-03T14:31:46.241Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-46347 (GCVE-0-2022-46347)
Vulnerability from nvd – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:42
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19079)
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.264
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:31:45.791Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-46347",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:21:20.520359Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:42:43.444Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.264"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.170"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V222.0MP12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2023",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V223.0Update2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19079)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-14T09:31:12.594Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-46347",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2022-11-30T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:42:43.444Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-46348 (GCVE-0-2022-46348)
Vulnerability from nvd – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:42
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.264), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19383)
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.264
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:31:46.340Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-46348",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:21:16.601521Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:42:35.733Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.264"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.170"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V222.0MP12"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2022",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"defaultStatus": "unknown",
"product": "Solid Edge SE2023",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V223.0Update2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.264), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Solid Edge SE2022 (All versions \u003c V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions \u003c V223.0Update2). The affected applications contain an out of bounds write past the end of an allocated structure while parsing specially crafted X_B files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19383)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-03-14T09:31:13.727Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-588101.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-46348",
"datePublished": "2022-12-13T00:00:00.000Z",
"dateReserved": "2022-11-30T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:42:35.733Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-39157 (GCVE-0-2022-39157)
Vulnerability from nvd – Published: 2022-11-08 00:00 – Updated: 2025-04-21 13:47
VLAI?
Summary
A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.0 (All versions >= V34.0.252 < V34.0.254), Parasolid V34.1 (All versions < V34.1.242), Parasolid V34.1 (All versions >= V34.1.242 < V34.1.244), Parasolid V35.0 (All versions < V35.0.170), Parasolid V35.0 (All versions >= V35.0.170 < V35.0.184), Simcenter Femap (All versions < V2023.1). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17745)
Severity ?
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V34.0 |
Affected:
All versions < V34.0.252
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T11:10:32.613Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853037.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-39157",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:22:35.932896Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:47:13.547Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V34.0.252 \u003c V34.0.254"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V34.1.242 \u003c V34.1.244"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.170"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V35.0.170 \u003c V35.0.184"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Femap",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2023.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.0 (All versions \u003e= V34.0.252 \u003c V34.0.254), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V34.1 (All versions \u003e= V34.1.242 \u003c V34.1.244), Parasolid V35.0 (All versions \u003c V35.0.170), Parasolid V35.0 (All versions \u003e= V35.0.170 \u003c V35.0.184), Simcenter Femap (All versions \u003c V2023.1). The affected application contains an out of bounds read past the end of an allocated structure while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17745)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-15T09:24:49.998Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853037.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-39157",
"datePublished": "2022-11-08T00:00:00.000Z",
"dateReserved": "2022-09-01T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:47:13.547Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-43397 (GCVE-0-2022-43397)
Vulnerability from nvd – Published: 2022-11-08 00:00 – Updated: 2025-04-21 13:46
VLAI?
Summary
A vulnerability has been identified in Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.170), Simcenter Femap (All versions < V2023.1). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17854)
Severity ?
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V34.0 |
Affected:
All versions < V34.0.252
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:32:57.387Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853037.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-43397",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-18T15:22:12.468907Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-21T13:46:27.727Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"defaultStatus": "unknown",
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.170"
}
]
},
{
"defaultStatus": "unknown",
"product": "Simcenter Femap",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2023.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.170), Simcenter Femap (All versions \u003c V2023.1). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17854)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-15T09:24:50.974Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853037.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-43397",
"datePublished": "2022-11-08T00:00:00.000Z",
"dateReserved": "2022-10-18T00:00:00.000Z",
"dateUpdated": "2025-04-21T13:46:27.727Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-39156 (GCVE-0-2022-39156)
Vulnerability from nvd – Published: 2022-09-13 09:41 – Updated: 2024-08-03 11:10
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18196)
Severity ?
No CVSS data available.
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.262
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T11:10:32.600Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.262"
}
]
},
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
},
{
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.161"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
},
{
"product": "Simcenter Femap V2022.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.1.3"
}
]
},
{
"product": "Simcenter Femap V2022.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.2.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18196)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-13T09:41:10",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-39156",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V33.1.262"
}
]
}
},
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
}
},
{
"product_name": "Parasolid V34.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.0.252"
}
]
}
},
{
"product_name": "Parasolid V34.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.1.242"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V35.0.161"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.1.3"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.2.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18196)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-39156",
"datePublished": "2022-09-13T09:41:10",
"dateReserved": "2022-09-01T00:00:00",
"dateUpdated": "2024-08-03T11:10:32.600Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-39155 (GCVE-0-2022-39155)
Vulnerability from nvd – Published: 2022-09-13 09:41 – Updated: 2024-08-03 11:10
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18192)
Severity ?
No CVSS data available.
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.262
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T11:10:32.610Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.262"
}
]
},
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
},
{
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.161"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
},
{
"product": "Simcenter Femap V2022.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.1.3"
}
]
},
{
"product": "Simcenter Femap V2022.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.2.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18192)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-13T09:41:09",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-39155",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V33.1.262"
}
]
}
},
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
}
},
{
"product_name": "Parasolid V34.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.0.252"
}
]
}
},
{
"product_name": "Parasolid V34.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.1.242"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V35.0.161"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.1.3"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.2.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18192)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-39155",
"datePublished": "2022-09-13T09:41:09",
"dateReserved": "2022-09-01T00:00:00",
"dateUpdated": "2024-08-03T11:10:32.610Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-39154 (GCVE-0-2022-39154)
Vulnerability from nvd – Published: 2022-09-13 09:41 – Updated: 2024-08-03 11:10
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18188)
Severity ?
No CVSS data available.
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.262
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T11:10:32.551Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.262"
}
]
},
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
},
{
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.161"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
},
{
"product": "Simcenter Femap V2022.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.1.3"
}
]
},
{
"product": "Simcenter Femap V2022.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.2.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18188)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-13T09:41:08",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-39154",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V33.1.262"
}
]
}
},
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
}
},
{
"product_name": "Parasolid V34.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.0.252"
}
]
}
},
{
"product_name": "Parasolid V34.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.1.242"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V35.0.161"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.1.3"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.2.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18188)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-39154",
"datePublished": "2022-09-13T09:41:09",
"dateReserved": "2022-09-01T00:00:00",
"dateUpdated": "2024-08-03T11:10:32.551Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-39153 (GCVE-0-2022-39153)
Vulnerability from nvd – Published: 2022-09-13 09:41 – Updated: 2024-08-03 11:10
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18187)
Severity ?
No CVSS data available.
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.262
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T11:10:32.564Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.262"
}
]
},
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
},
{
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.161"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
},
{
"product": "Simcenter Femap V2022.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.1.3"
}
]
},
{
"product": "Simcenter Femap V2022.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.2.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18187)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-13T09:41:08",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-39153",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V33.1.262"
}
]
}
},
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
}
},
{
"product_name": "Parasolid V34.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.0.252"
}
]
}
},
{
"product_name": "Parasolid V34.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.1.242"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V35.0.161"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.1.3"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.2.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application is vulnerable to out of bounds read past the end of an allocated buffer when parsing X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-18187)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-39153",
"datePublished": "2022-09-13T09:41:08",
"dateReserved": "2022-09-01T00:00:00",
"dateUpdated": "2024-08-03T11:10:32.564Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-39152 (GCVE-0-2022-39152)
Vulnerability from nvd – Published: 2022-09-13 09:41 – Updated: 2024-08-03 11:10
VLAI?
Summary
A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V33.1 (All versions >= V33.1.262 < V33.1.263), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Parasolid V35.0 (All versions >= V35.0.161 < V35.0.164), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17740)
Severity ?
No CVSS data available.
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | Parasolid V33.1 |
Affected:
All versions < V33.1.262
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T11:10:32.670Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V33.1.262"
}
]
},
{
"product": "Parasolid V33.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
},
{
"product": "Parasolid V34.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.0.252"
}
]
},
{
"product": "Parasolid V34.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V34.1.242"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V35.0.161"
}
]
},
{
"product": "Parasolid V35.0",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
},
{
"product": "Simcenter Femap V2022.1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.1.3"
}
]
},
{
"product": "Simcenter Femap V2022.2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2022.2.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17740)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-13T09:41:07",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-39152",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V33.1.262"
}
]
}
},
{
"product_name": "Parasolid V33.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V33.1.262 \u003c V33.1.263"
}
]
}
},
{
"product_name": "Parasolid V34.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.0.252"
}
]
}
},
{
"product_name": "Parasolid V34.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V34.1.242"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V35.0.161"
}
]
}
},
{
"product_name": "Parasolid V35.0",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V35.0.161 \u003c V35.0.164"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.1",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.1.3"
}
]
}
},
{
"product_name": "Simcenter Femap V2022.2",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2022.2.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Parasolid V33.1 (All versions \u003c V33.1.262), Parasolid V33.1 (All versions \u003e= V33.1.262 \u003c V33.1.263), Parasolid V34.0 (All versions \u003c V34.0.252), Parasolid V34.1 (All versions \u003c V34.1.242), Parasolid V35.0 (All versions \u003c V35.0.161), Parasolid V35.0 (All versions \u003e= V35.0.161 \u003c V35.0.164), Simcenter Femap V2022.1 (All versions \u003c V2022.1.3), Simcenter Femap V2022.2 (All versions \u003c V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17740)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-518824.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-39152",
"datePublished": "2022-09-13T09:41:07",
"dateReserved": "2022-09-01T00:00:00",
"dateUpdated": "2024-08-03T11:10:32.670Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}