Search criteria

28 vulnerabilities found for Poly Clariti Manager by HP Inc.

CVE-2025-43489 (GCVE-0-2025-43489)

Vulnerability from cvelistv5 – Published: 2025-07-22 23:36 – Updated: 2025-07-23 15:14
VLAI?
Summary
A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The vulnerability could deserialize untrusted data without validation. HP has addressed the issue in the latest software update.
CWE
  • CWE-502 - Deserialization of Untrusted Data
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43489",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T14:53:26.779409Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T15:14:51.346Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The vulnerability could deserialize untrusted data without validation. HP has addressed the issue in the latest software update.\u003cbr\u003e"
            }
          ],
          "value": "A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The vulnerability could deserialize untrusted data without validation. HP has addressed the issue in the latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 2,
            "baseSeverity": "LOW",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-502",
              "description": "CWE-502 Deserialization of Untrusted Data",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:36:58.181Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43489",
    "datePublished": "2025-07-22T23:36:58.181Z",
    "dateReserved": "2025-04-16T15:25:24.712Z",
    "dateUpdated": "2025-07-23T15:14:51.346Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43488 (GCVE-0-2025-43488)

Vulnerability from cvelistv5 – Published: 2025-07-22 23:26 – Updated: 2025-07-23 15:14
VLAI?
Summary
A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.2. The vulnerability could allow a bypass of the application's XSS filter by submitting untrusted characters. HP has addressed the issue in the latest software update.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43488",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T14:53:32.556379Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T15:14:56.207Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.2. The vulnerability could allow a bypass of the application\u0027s XSS filter by submitting untrusted characters. HP has addressed the issue in the latest software update.\u003cbr\u003e"
            }
          ],
          "value": "A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.2. The vulnerability could allow a bypass of the application\u0027s XSS filter by submitting untrusted characters. HP has addressed the issue in the latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 2,
            "baseSeverity": "LOW",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:26:24.451Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43488",
    "datePublished": "2025-07-22T23:26:24.451Z",
    "dateReserved": "2025-04-16T15:25:24.712Z",
    "dateUpdated": "2025-07-23T15:14:56.207Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43487 (GCVE-0-2025-43487)

Vulnerability from cvelistv5 – Published: 2025-07-22 23:24 – Updated: 2025-07-23 13:18
VLAI?
Summary
A potential privilege escalation through Sudo vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.2. The firmware flaw does not properly implement access controls. HP has addressed the issue in the latest software update.
CWE
  • CWE-250 - Execution with Unnecessary Privileges
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43487",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T13:17:37.578534Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T13:18:02.474Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A potential privilege escalation through Sudo vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.2. The firmware flaw does not properly implement access controls. HP has addressed the issue in the latest software update.\u003cbr\u003e"
            }
          ],
          "value": "A potential privilege escalation through Sudo vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.2. The firmware flaw does not properly implement access controls. HP has addressed the issue in the latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "LOW",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:L/VA:N/SC:H/SI:L/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-250",
              "description": "CWE-250: Execution with Unnecessary Privileges",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:24:44.253Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43487",
    "datePublished": "2025-07-22T23:24:44.253Z",
    "dateReserved": "2025-04-16T15:25:24.712Z",
    "dateUpdated": "2025-07-23T13:18:02.474Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43486 (GCVE-0-2025-43486)

Vulnerability from cvelistv5 – Published: 2025-07-22 23:21 – Updated: 2025-07-23 14:56
VLAI?
Summary
A potential stored cross-site scripting vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The website allows user input to be stored and rendered without proper sanitization. HP has addressed the issue in the latest software update.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43486",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T14:56:00.463994Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T14:56:14.596Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A potential stored cross-site scripting vulnerability has been\nidentified in the Poly Clariti Manager for versions prior to 10.12.1. The\nwebsite allows user input to be stored and rendered without proper\nsanitization. HP has addressed the issue in the latest software update."
            }
          ],
          "value": "A potential stored cross-site scripting vulnerability has been\nidentified in the Poly Clariti Manager for versions prior to 10.12.1. The\nwebsite allows user input to be stored and rendered without proper\nsanitization. HP has addressed the issue in the latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:N/VA:N/SC:L/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:21:42.248Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43486",
    "datePublished": "2025-07-22T23:21:42.248Z",
    "dateReserved": "2025-04-16T15:25:24.712Z",
    "dateUpdated": "2025-07-23T14:56:14.596Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43485 (GCVE-0-2025-43485)

Vulnerability from cvelistv5 – Published: 2025-07-22 23:18 – Updated: 2025-07-23 14:58
VLAI?
Summary
A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.2. The vulnerability could potentially allow a privileged user to retrieve credentials from the log files. HP has addressed the issue in the latest software update.
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43485",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T14:58:23.583510Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T14:58:30.540Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA potential security\nvulnerability has been identified in the Poly Clariti Manager for versions\nprior to 10.12.2. The vulnerability could potentially allow a privileged\nuser to retrieve credentials from the log files. HP has addressed the issue in\nthe latest software update.\u003c/p\u003e"
            }
          ],
          "value": "A potential security\nvulnerability has been identified in the Poly Clariti Manager for versions\nprior to 10.12.2. The vulnerability could potentially allow a privileged\nuser to retrieve credentials from the log files. HP has addressed the issue in\nthe latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:N/VA:N/SC:L/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:18:37.858Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43485",
    "datePublished": "2025-07-22T23:18:37.858Z",
    "dateReserved": "2025-04-16T15:25:24.712Z",
    "dateUpdated": "2025-07-23T14:58:30.540Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43484 (GCVE-0-2025-43484)

Vulnerability from cvelistv5 – Published: 2025-07-22 23:16 – Updated: 2025-07-23 20:11
VLAI?
Summary
A potential reflected cross-site scripting vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The website does not validate or sanitize the user input before rendering it in the response. HP has addressed the issue in the latest software update.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43484",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T20:11:34.526319Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T20:11:43.688Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A potential reflected cross-site scripting vulnerability has been\nidentified in the Poly Clariti Manager for versions prior to 10.12.1. The\nwebsite does not validate or sanitize the user input before rendering it in the\nresponse. HP has addressed the issue in the latest software update."
            }
          ],
          "value": "A potential reflected cross-site scripting vulnerability has been\nidentified in the Poly Clariti Manager for versions prior to 10.12.1. The\nwebsite does not validate or sanitize the user input before rendering it in the\nresponse. HP has addressed the issue in the latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:L/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:16:02.138Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43484",
    "datePublished": "2025-07-22T23:16:02.138Z",
    "dateReserved": "2025-04-16T15:25:24.712Z",
    "dateUpdated": "2025-07-23T20:11:43.688Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43483 (GCVE-0-2025-43483)

Vulnerability from cvelistv5 – Published: 2025-07-22 23:14 – Updated: 2025-07-23 20:11
VLAI?
Summary
A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The vulnerability could allow the retrieval of hardcoded cryptographic keys. HP has addressed the issue in the latest software update.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43483",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T20:10:49.864916Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T20:11:12.870Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003e\u003cp\u003eA potential security vulnerability has been\nidentified in the Poly Clariti Manager for versions prior to 10.12.1. The\nvulnerability could allow the retrieval of hardcoded cryptographic keys. HP has\naddressed the issue in the latest software update.\u003c/p\u003e\u003c/span\u003e"
            }
          ],
          "value": "A potential security vulnerability has been\nidentified in the Poly Clariti Manager for versions prior to 10.12.1. The\nvulnerability could allow the retrieval of hardcoded cryptographic keys. HP has\naddressed the issue in the latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:N/VA:N/SC:L/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321: Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:14:26.801Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43483",
    "datePublished": "2025-07-22T23:14:26.801Z",
    "dateReserved": "2025-04-16T15:25:24.712Z",
    "dateUpdated": "2025-07-23T20:11:12.870Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43022 (GCVE-0-2025-43022)

Vulnerability from cvelistv5 – Published: 2025-07-22 23:05 – Updated: 2025-07-23 20:10
VLAI?
Summary
A potential SQL injection vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The vulnerability could allow a privileged user to execute SQL commands. HP has addressed the issue in the latest software update.
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43022",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T20:10:21.143873Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T20:10:32.249Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A potential SQL injection vulnerability has been identified in the Poly\nClariti Manager for versions prior to 10.12.1. The vulnerability could allow\na privileged user to execute SQL commands. HP has addressed the issue in\nthe latest software update.\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "A potential SQL injection vulnerability has been identified in the Poly\nClariti Manager for versions prior to 10.12.1. The vulnerability could allow\na privileged user to execute SQL commands. HP has addressed the issue in\nthe latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "LOW",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "LOW",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:05:24.070Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43022",
    "datePublished": "2025-07-22T23:05:24.070Z",
    "dateReserved": "2025-04-16T13:49:21.689Z",
    "dateUpdated": "2025-07-23T20:10:32.249Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43021 (GCVE-0-2025-43021)

Vulnerability from cvelistv5 – Published: 2025-07-22 23:03 – Updated: 2025-07-23 20:09
VLAI?
Summary
A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The vulnerability could allow the use and retrieval of the default password. HP has addressed the issue in the latest software update.
CWE
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43021",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T20:08:55.434389Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T20:09:03.981Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eA potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The vulnerability could allow the use and retrieval of the default password. HP has addressed the issue in the latest software update.\u003c/span\u003e\n\n\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The vulnerability could allow the use and retrieval of the default password. HP has addressed the issue in the latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:N/VA:N/SC:L/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1393",
              "description": "CWE-1393: Use of Default Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:11:58.549Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43021",
    "datePublished": "2025-07-22T23:03:32.074Z",
    "dateReserved": "2025-04-16T13:49:21.689Z",
    "dateUpdated": "2025-07-23T20:09:03.981Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43020 (GCVE-0-2025-43020)

Vulnerability from cvelistv5 – Published: 2025-07-22 23:01 – Updated: 2025-07-23 19:58
VLAI?
Summary
A potential command injection vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.2. The vulnerability could allow a privileged user to submit arbitrary input. HP has addressed the issue in the latest software update.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43020",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T19:58:33.347366Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T19:58:42.413Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA potential command\ninjection vulnerability has been identified in the Poly Clariti Manager for\nversions prior to 10.12.2. The vulnerability could allow a privileged user\nto submit arbitrary input. HP has addressed the issue in the latest software update.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "A potential command\ninjection vulnerability has been identified in the Poly Clariti Manager for\nversions prior to 10.12.2. The vulnerability could allow a privileged user\nto submit arbitrary input. HP has addressed the issue in the latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:N/VA:N/SC:L/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:01:09.020Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43020",
    "datePublished": "2025-07-22T23:01:09.020Z",
    "dateReserved": "2025-04-16T13:49:21.689Z",
    "dateUpdated": "2025-07-23T19:58:42.413Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-41912 (GCVE-0-2024-41912)

Vulnerability from cvelistv5 – Published: 2024-08-07 19:54 – Updated: 2025-03-13 20:26
VLAI?
Summary
A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware flaw does not properly implement access controls.
CWE
  • CWE-284 - Improper Access Control
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-41912",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-03T14:36:16.370155Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-284",
                "description": "CWE-284 Improper Access Control",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-13T20:26:13.846Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware flaw does not properly implement access controls."
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-07T19:54:47.266Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_11006235-11006266-16/hpsbpy03958"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2024-41912",
    "datePublished": "2024-08-07T19:54:47.266Z",
    "dateReserved": "2024-07-23T15:33:15.305Z",
    "dateUpdated": "2025-03-13T20:26:13.846Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-41911 (GCVE-0-2024-41911)

Vulnerability from cvelistv5 – Published: 2024-08-06 14:07 – Updated: 2024-10-28 20:23
VLAI?
Summary
A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The flaw does not properly neutralize input during a web page generation.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.4,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-41911",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-06T15:52:22.228928Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-79",
                "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-28T20:23:13.420Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The flaw does not properly neutralize input during a web page generation."
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-06T14:07:33.637Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_11006770-11006795-16/hpsbpy03959"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2024-41911",
    "datePublished": "2024-08-06T14:07:33.637Z",
    "dateReserved": "2024-07-23T15:33:15.305Z",
    "dateUpdated": "2024-10-28T20:23:13.420Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-41910 (GCVE-0-2024-41910)

Vulnerability from cvelistv5 – Published: 2024-08-06 14:05 – Updated: 2025-03-14 16:06
VLAI?
Summary
A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware contained multiple XSS vulnerabilities in the version of JavaScript used.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.1,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-41910",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-03T14:36:11.018010Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-79",
                "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-14T16:06:19.571Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices.  The firmware contained multiple XSS vulnerabilities in the version of JavaScript used."
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-08T17:27:55.381Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_11006981-11007005-16/hpsbpy03960"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2024-41910",
    "datePublished": "2024-08-06T14:05:28.473Z",
    "dateReserved": "2024-07-23T15:33:15.305Z",
    "dateUpdated": "2025-03-14T16:06:19.571Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-41913 (GCVE-0-2024-41913)

Vulnerability from cvelistv5 – Published: 2024-08-06 13:57 – Updated: 2025-03-19 15:21
VLAI?
Summary
A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware flaw does not properly sanitize User input.
CWE
  • CWE-434 - Unrestricted Upload of File with Dangerous Type
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-41913",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-19T15:20:42.654177Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-434",
                "description": "CWE-434 Unrestricted Upload of File with Dangerous Type",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-19T15:21:17.519Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices.  The firmware flaw does not properly sanitize User input."
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-06T13:57:29.551Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_11006488-11006512-16/hpsbpy03957"
        }
      ],
      "title": "Clariti Manager \u2013 Arbitrary File Upload",
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2024-41913",
    "datePublished": "2024-08-06T13:57:29.551Z",
    "dateReserved": "2024-07-23T15:33:15.305Z",
    "dateUpdated": "2025-03-19T15:21:17.519Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43489 (GCVE-0-2025-43489)

Vulnerability from nvd – Published: 2025-07-22 23:36 – Updated: 2025-07-23 15:14
VLAI?
Summary
A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The vulnerability could deserialize untrusted data without validation. HP has addressed the issue in the latest software update.
CWE
  • CWE-502 - Deserialization of Untrusted Data
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43489",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T14:53:26.779409Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T15:14:51.346Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The vulnerability could deserialize untrusted data without validation. HP has addressed the issue in the latest software update.\u003cbr\u003e"
            }
          ],
          "value": "A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The vulnerability could deserialize untrusted data without validation. HP has addressed the issue in the latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 2,
            "baseSeverity": "LOW",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-502",
              "description": "CWE-502 Deserialization of Untrusted Data",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:36:58.181Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43489",
    "datePublished": "2025-07-22T23:36:58.181Z",
    "dateReserved": "2025-04-16T15:25:24.712Z",
    "dateUpdated": "2025-07-23T15:14:51.346Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43488 (GCVE-0-2025-43488)

Vulnerability from nvd – Published: 2025-07-22 23:26 – Updated: 2025-07-23 15:14
VLAI?
Summary
A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.2. The vulnerability could allow a bypass of the application's XSS filter by submitting untrusted characters. HP has addressed the issue in the latest software update.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43488",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T14:53:32.556379Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T15:14:56.207Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.2. The vulnerability could allow a bypass of the application\u0027s XSS filter by submitting untrusted characters. HP has addressed the issue in the latest software update.\u003cbr\u003e"
            }
          ],
          "value": "A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.2. The vulnerability could allow a bypass of the application\u0027s XSS filter by submitting untrusted characters. HP has addressed the issue in the latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 2,
            "baseSeverity": "LOW",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:26:24.451Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43488",
    "datePublished": "2025-07-22T23:26:24.451Z",
    "dateReserved": "2025-04-16T15:25:24.712Z",
    "dateUpdated": "2025-07-23T15:14:56.207Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43487 (GCVE-0-2025-43487)

Vulnerability from nvd – Published: 2025-07-22 23:24 – Updated: 2025-07-23 13:18
VLAI?
Summary
A potential privilege escalation through Sudo vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.2. The firmware flaw does not properly implement access controls. HP has addressed the issue in the latest software update.
CWE
  • CWE-250 - Execution with Unnecessary Privileges
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43487",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T13:17:37.578534Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T13:18:02.474Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A potential privilege escalation through Sudo vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.2. The firmware flaw does not properly implement access controls. HP has addressed the issue in the latest software update.\u003cbr\u003e"
            }
          ],
          "value": "A potential privilege escalation through Sudo vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.2. The firmware flaw does not properly implement access controls. HP has addressed the issue in the latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "LOW",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:L/VA:N/SC:H/SI:L/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-250",
              "description": "CWE-250: Execution with Unnecessary Privileges",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:24:44.253Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43487",
    "datePublished": "2025-07-22T23:24:44.253Z",
    "dateReserved": "2025-04-16T15:25:24.712Z",
    "dateUpdated": "2025-07-23T13:18:02.474Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43486 (GCVE-0-2025-43486)

Vulnerability from nvd – Published: 2025-07-22 23:21 – Updated: 2025-07-23 14:56
VLAI?
Summary
A potential stored cross-site scripting vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The website allows user input to be stored and rendered without proper sanitization. HP has addressed the issue in the latest software update.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43486",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T14:56:00.463994Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T14:56:14.596Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A potential stored cross-site scripting vulnerability has been\nidentified in the Poly Clariti Manager for versions prior to 10.12.1. The\nwebsite allows user input to be stored and rendered without proper\nsanitization. HP has addressed the issue in the latest software update."
            }
          ],
          "value": "A potential stored cross-site scripting vulnerability has been\nidentified in the Poly Clariti Manager for versions prior to 10.12.1. The\nwebsite allows user input to be stored and rendered without proper\nsanitization. HP has addressed the issue in the latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:N/VA:N/SC:L/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:21:42.248Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43486",
    "datePublished": "2025-07-22T23:21:42.248Z",
    "dateReserved": "2025-04-16T15:25:24.712Z",
    "dateUpdated": "2025-07-23T14:56:14.596Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43485 (GCVE-0-2025-43485)

Vulnerability from nvd – Published: 2025-07-22 23:18 – Updated: 2025-07-23 14:58
VLAI?
Summary
A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.2. The vulnerability could potentially allow a privileged user to retrieve credentials from the log files. HP has addressed the issue in the latest software update.
CWE
  • CWE-532 - Insertion of Sensitive Information into Log File
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43485",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T14:58:23.583510Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T14:58:30.540Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA potential security\nvulnerability has been identified in the Poly Clariti Manager for versions\nprior to 10.12.2. The vulnerability could potentially allow a privileged\nuser to retrieve credentials from the log files. HP has addressed the issue in\nthe latest software update.\u003c/p\u003e"
            }
          ],
          "value": "A potential security\nvulnerability has been identified in the Poly Clariti Manager for versions\nprior to 10.12.2. The vulnerability could potentially allow a privileged\nuser to retrieve credentials from the log files. HP has addressed the issue in\nthe latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:N/VA:N/SC:L/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-532",
              "description": "CWE-532 Insertion of Sensitive Information into Log File",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:18:37.858Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43485",
    "datePublished": "2025-07-22T23:18:37.858Z",
    "dateReserved": "2025-04-16T15:25:24.712Z",
    "dateUpdated": "2025-07-23T14:58:30.540Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43484 (GCVE-0-2025-43484)

Vulnerability from nvd – Published: 2025-07-22 23:16 – Updated: 2025-07-23 20:11
VLAI?
Summary
A potential reflected cross-site scripting vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The website does not validate or sanitize the user input before rendering it in the response. HP has addressed the issue in the latest software update.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43484",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T20:11:34.526319Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T20:11:43.688Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A potential reflected cross-site scripting vulnerability has been\nidentified in the Poly Clariti Manager for versions prior to 10.12.1. The\nwebsite does not validate or sanitize the user input before rendering it in the\nresponse. HP has addressed the issue in the latest software update."
            }
          ],
          "value": "A potential reflected cross-site scripting vulnerability has been\nidentified in the Poly Clariti Manager for versions prior to 10.12.1. The\nwebsite does not validate or sanitize the user input before rendering it in the\nresponse. HP has addressed the issue in the latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 6,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:L/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:16:02.138Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43484",
    "datePublished": "2025-07-22T23:16:02.138Z",
    "dateReserved": "2025-04-16T15:25:24.712Z",
    "dateUpdated": "2025-07-23T20:11:43.688Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43483 (GCVE-0-2025-43483)

Vulnerability from nvd – Published: 2025-07-22 23:14 – Updated: 2025-07-23 20:11
VLAI?
Summary
A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The vulnerability could allow the retrieval of hardcoded cryptographic keys. HP has addressed the issue in the latest software update.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43483",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T20:10:49.864916Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T20:11:12.870Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003e\u003cp\u003eA potential security vulnerability has been\nidentified in the Poly Clariti Manager for versions prior to 10.12.1. The\nvulnerability could allow the retrieval of hardcoded cryptographic keys. HP has\naddressed the issue in the latest software update.\u003c/p\u003e\u003c/span\u003e"
            }
          ],
          "value": "A potential security vulnerability has been\nidentified in the Poly Clariti Manager for versions prior to 10.12.1. The\nvulnerability could allow the retrieval of hardcoded cryptographic keys. HP has\naddressed the issue in the latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:N/VA:N/SC:L/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321: Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:14:26.801Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43483",
    "datePublished": "2025-07-22T23:14:26.801Z",
    "dateReserved": "2025-04-16T15:25:24.712Z",
    "dateUpdated": "2025-07-23T20:11:12.870Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43022 (GCVE-0-2025-43022)

Vulnerability from nvd – Published: 2025-07-22 23:05 – Updated: 2025-07-23 20:10
VLAI?
Summary
A potential SQL injection vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The vulnerability could allow a privileged user to execute SQL commands. HP has addressed the issue in the latest software update.
CWE
  • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43022",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T20:10:21.143873Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T20:10:32.249Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A potential SQL injection vulnerability has been identified in the Poly\nClariti Manager for versions prior to 10.12.1. The vulnerability could allow\na privileged user to execute SQL commands. HP has addressed the issue in\nthe latest software update.\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "A potential SQL injection vulnerability has been identified in the Poly\nClariti Manager for versions prior to 10.12.1. The vulnerability could allow\na privileged user to execute SQL commands. HP has addressed the issue in\nthe latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "LOW",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "LOW",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:05:24.070Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43022",
    "datePublished": "2025-07-22T23:05:24.070Z",
    "dateReserved": "2025-04-16T13:49:21.689Z",
    "dateUpdated": "2025-07-23T20:10:32.249Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43021 (GCVE-0-2025-43021)

Vulnerability from nvd – Published: 2025-07-22 23:03 – Updated: 2025-07-23 20:09
VLAI?
Summary
A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The vulnerability could allow the use and retrieval of the default password. HP has addressed the issue in the latest software update.
CWE
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43021",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T20:08:55.434389Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T20:09:03.981Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003eA potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The vulnerability could allow the use and retrieval of the default password. HP has addressed the issue in the latest software update.\u003c/span\u003e\n\n\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "A potential security vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.1. The vulnerability could allow the use and retrieval of the default password. HP has addressed the issue in the latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:L/UI:N/VC:H/VI:N/VA:N/SC:L/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1393",
              "description": "CWE-1393: Use of Default Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:11:58.549Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43021",
    "datePublished": "2025-07-22T23:03:32.074Z",
    "dateReserved": "2025-04-16T13:49:21.689Z",
    "dateUpdated": "2025-07-23T20:09:03.981Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-43020 (GCVE-0-2025-43020)

Vulnerability from nvd – Published: 2025-07-22 23:01 – Updated: 2025-07-23 19:58
VLAI?
Summary
A potential command injection vulnerability has been identified in the Poly Clariti Manager for versions prior to 10.12.2. The vulnerability could allow a privileged user to submit arbitrary input. HP has addressed the issue in the latest software update.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-43020",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T19:58:33.347366Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T19:58:42.413Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA potential command\ninjection vulnerability has been identified in the Poly Clariti Manager for\nversions prior to 10.12.2. The vulnerability could allow a privileged user\nto submit arbitrary input. HP has addressed the issue in the latest software update.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "A potential command\ninjection vulnerability has been identified in the Poly Clariti Manager for\nversions prior to 10.12.2. The vulnerability could allow a privileged user\nto submit arbitrary input. HP has addressed the issue in the latest software update."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:N/VA:N/SC:L/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-22T23:01:09.020Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Poly Clariti Manager - Multiple Security Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2025-43020",
    "datePublished": "2025-07-22T23:01:09.020Z",
    "dateReserved": "2025-04-16T13:49:21.689Z",
    "dateUpdated": "2025-07-23T19:58:42.413Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-41912 (GCVE-0-2024-41912)

Vulnerability from nvd – Published: 2024-08-07 19:54 – Updated: 2025-03-13 20:26
VLAI?
Summary
A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware flaw does not properly implement access controls.
CWE
  • CWE-284 - Improper Access Control
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-41912",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-03T14:36:16.370155Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-284",
                "description": "CWE-284 Improper Access Control",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-13T20:26:13.846Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware flaw does not properly implement access controls."
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-07T19:54:47.266Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_11006235-11006266-16/hpsbpy03958"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2024-41912",
    "datePublished": "2024-08-07T19:54:47.266Z",
    "dateReserved": "2024-07-23T15:33:15.305Z",
    "dateUpdated": "2025-03-13T20:26:13.846Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-41911 (GCVE-0-2024-41911)

Vulnerability from nvd – Published: 2024-08-06 14:07 – Updated: 2024-10-28 20:23
VLAI?
Summary
A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The flaw does not properly neutralize input during a web page generation.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 5.4,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "LOW",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-41911",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-06T15:52:22.228928Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-79",
                "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-28T20:23:13.420Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The flaw does not properly neutralize input during a web page generation."
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-06T14:07:33.637Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_11006770-11006795-16/hpsbpy03959"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2024-41911",
    "datePublished": "2024-08-06T14:07:33.637Z",
    "dateReserved": "2024-07-23T15:33:15.305Z",
    "dateUpdated": "2024-10-28T20:23:13.420Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-41910 (GCVE-0-2024-41910)

Vulnerability from nvd – Published: 2024-08-06 14:05 – Updated: 2025-03-14 16:06
VLAI?
Summary
A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware contained multiple XSS vulnerabilities in the version of JavaScript used.
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 6.1,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "LOW",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "CHANGED",
              "userInteraction": "REQUIRED",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-41910",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-03T14:36:11.018010Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-79",
                "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-14T16:06:19.571Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices.  The firmware contained multiple XSS vulnerabilities in the version of JavaScript used."
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-08T17:27:55.381Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_11006981-11007005-16/hpsbpy03960"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2024-41910",
    "datePublished": "2024-08-06T14:05:28.473Z",
    "dateReserved": "2024-07-23T15:33:15.305Z",
    "dateUpdated": "2025-03-14T16:06:19.571Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-41913 (GCVE-0-2024-41913)

Vulnerability from nvd – Published: 2024-08-06 13:57 – Updated: 2025-03-19 15:21
VLAI?
Summary
A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware flaw does not properly sanitize User input.
CWE
  • CWE-434 - Unrestricted Upload of File with Dangerous Type
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-41913",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-19T15:20:42.654177Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-434",
                "description": "CWE-434 Unrestricted Upload of File with Dangerous Type",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-19T15:21:17.519Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices.  The firmware flaw does not properly sanitize User input."
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-06T13:57:29.551Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_11006488-11006512-16/hpsbpy03957"
        }
      ],
      "title": "Clariti Manager \u2013 Arbitrary File Upload",
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2024-41913",
    "datePublished": "2024-08-06T13:57:29.551Z",
    "dateReserved": "2024-07-23T15:33:15.305Z",
    "dateUpdated": "2025-03-19T15:21:17.519Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}