CVE-2024-41912 (GCVE-0-2024-41912)

Vulnerability from cvelistv5 – Published: 2024-08-07 19:54 – Updated: 2025-03-13 20:26
VLAI?
Summary
A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware flaw does not properly implement access controls.
CWE
  • CWE-284 - Improper Access Control
Assigner
hp
Impacted products
Vendor Product Version
HP Inc. Poly Clariti Manager Affected: See HP Security Bulletin reference for affected versions.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-41912",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-03T14:36:16.370155Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-284",
                "description": "CWE-284 Improper Access Control",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-13T20:26:13.846Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Poly Clariti Manager",
          "vendor": "HP Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "See HP Security Bulletin reference for affected versions."
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware flaw does not properly implement access controls."
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-07T19:54:47.266Z",
        "orgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
        "shortName": "hp"
      },
      "references": [
        {
          "url": "https://support.hp.com/us-en/document/ish_11006235-11006266-16/hpsbpy03958"
        }
      ],
      "x_generator": {
        "engine": "cveClient/1.0.15"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "74586083-13ce-40fd-b46a-8e5d23cfbcb2",
    "assignerShortName": "hp",
    "cveId": "CVE-2024-41912",
    "datePublished": "2024-08-07T19:54:47.266Z",
    "dateReserved": "2024-07-23T15:33:15.305Z",
    "dateUpdated": "2025-03-13T20:26:13.846Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:hp:poly_clariti_manager_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"10.10.2.2_100\", \"matchCriteriaId\": \"BDAFC172-AA9F-4B89-932D-3F13D10F99C9\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:hp:poly_clariti_manager:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B85257C9-48C2-4B7F-8B0D-D2BF6C49C618\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware flaw does not properly implement access controls.\"}, {\"lang\": \"es\", \"value\": \"Se descubri\\u00f3 una vulnerabilidad en las versiones de firmware hasta 10.10.2.2 en dispositivos Poly Clariti Manager. La falla del firmware no implementa adecuadamente los controles de acceso.\"}]",
      "id": "CVE-2024-41912",
      "lastModified": "2024-09-06T15:13:26.177",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}]}",
      "published": "2024-08-07T20:15:50.877",
      "references": "[{\"url\": \"https://support.hp.com/us-en/document/ish_11006235-11006266-16/hpsbpy03958\", \"source\": \"hp-security-alert@hp.com\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "hp-security-alert@hp.com",
      "vulnStatus": "Analyzed",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-41912\",\"sourceIdentifier\":\"hp-security-alert@hp.com\",\"published\":\"2024-08-07T20:15:50.877\",\"lastModified\":\"2025-10-02T17:37:04.417\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware flaw does not properly implement access controls.\"},{\"lang\":\"es\",\"value\":\"Se descubri\u00f3 una vulnerabilidad en las versiones de firmware hasta 10.10.2.2 en dispositivos Poly Clariti Manager. La falla del firmware no implementa adecuadamente los controles de acceso.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:poly_clariti_manager:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"10.12.0.2_100\",\"matchCriteriaId\":\"01297D80-BD62-405F-B5AC-934060D6696F\"}]}]}],\"references\":[{\"url\":\"https://support.hp.com/us-en/document/ish_11006235-11006266-16/hpsbpy03958\",\"source\":\"hp-security-alert@hp.com\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-41912\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-03T14:36:16.370155Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-284\", \"description\": \"CWE-284 Improper Access Control\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-08-09T13:46:06.999Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"HP Inc.\", \"product\": \"Poly Clariti Manager\", \"versions\": [{\"status\": \"affected\", \"version\": \"See HP Security Bulletin reference for affected versions.\"}]}], \"references\": [{\"url\": \"https://support.hp.com/us-en/document/ish_11006235-11006266-16/hpsbpy03958\"}], \"x_generator\": {\"engine\": \"cveClient/1.0.15\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability was discovered in the firmware builds up to 10.10.2.2 in Poly Clariti Manager devices. The firmware flaw does not properly implement access controls.\"}], \"providerMetadata\": {\"orgId\": \"74586083-13ce-40fd-b46a-8e5d23cfbcb2\", \"shortName\": \"hp\", \"dateUpdated\": \"2024-08-07T19:54:47.266Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-41912\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-03-13T20:26:13.846Z\", \"dateReserved\": \"2024-07-23T15:33:15.305Z\", \"assignerOrgId\": \"74586083-13ce-40fd-b46a-8e5d23cfbcb2\", \"datePublished\": \"2024-08-07T19:54:47.266Z\", \"assignerShortName\": \"hp\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…