All the vulnerabilites related to Schweitzer Engineering Laboratories - SEL-751 Feeder Protection Relay
cve-2024-2103
Vulnerability from cvelistv5
Published
2024-04-04 15:18
Modified
2024-08-01 19:03
Severity ?
EPSS score ?
Summary
Inclusion of Undocumented Features
References
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-2103", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-04-04T17:11:57.943227Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:28:59.654Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T19:03:39.137Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://selinc.com/support/security-notifications/external-reports/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "SEL-700BT Motor Bus Transfer Relay", "vendor": "Schweitzer Engineering Laboratories", "versions": [ { "lessThan": "R301-V6", "status": "affected", "version": "R301-V0", "versionType": "custom" }, { "lessThan": "R302-V1", "status": "affected", "version": "R302-V0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": " SEL-700G Generator Protection Relay", "vendor": "Schweitzer Engineering Laboratories", "versions": [ { "lessThan": "R301-V6", "status": "affected", "version": "R100-V0", "versionType": "custom" }, { "lessThan": "R302-V1", "status": "affected", "version": "R302-V0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "SEL-710-5 Motor Protection Relay", "vendor": "SEL-710-5 Motor Protection Relay", "versions": [ { "lessThan": "R302-V1", "status": "affected", "version": "R100-V0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "SEL-751 Feeder Protection Relay", "vendor": "Schweitzer Engineering Laboratories", "versions": [ { "lessThan": "R302-V3", "status": "affected", "version": "R101-V0", "versionType": "custom" }, { "lessThan": "R400-V2", "status": "affected", "version": "R400-V0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "SEL-787-2/-3/-4 Transformer Protection Relay", "vendor": "Schweitzer Engineering Laboratories", "versions": [ { "lessThan": "R302-V1", "status": "affected", "version": "R100-V0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "SEL-787Z High-Impedance Differential Relay", "vendor": "Schweitzer Engineering Laboratories", "versions": [ { "lessThan": "R302-V3", "status": "affected", "version": "R302-V0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Anonymous Researcher" } ], "datePublic": "2024-04-04T15:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\n\nInclusion of undocumented features vulnerability accessible when logged on with a privileged access level on the following Schweitzer Engineering Laboratories relays could allow the relay to behave unpredictably:\u003cbr\u003eSEL-700BT Motor Bus Transfer Relay, SEL-700G Generator Protection Relay, SEL-710-5 Motor Protection Relay, SEL-751 Feeder Protection Relay, SEL-787-2/-3/-4 Transformer Protection Relay, SEL-787Z High-Impedance Differential Relay\u003cbr\u003e\u003cbr\u003e. See product instruction manual appendix A dated 20240308 for more details regarding the SEL-751 Feeder Protection Relay. For more information for the other affected products, see their instruction manuals dated 20240329.\u003cp\u003e\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003e\u003cbr\u003e\u003c/span\u003e\u003c/p\u003e" } ], "value": "\nInclusion of undocumented features vulnerability accessible when logged on with a privileged access level on the following Schweitzer Engineering Laboratories relays could allow the relay to behave unpredictably:\nSEL-700BT Motor Bus Transfer Relay, SEL-700G Generator Protection Relay, SEL-710-5 Motor Protection Relay, SEL-751 Feeder Protection Relay, SEL-787-2/-3/-4 Transformer Protection Relay, SEL-787Z High-Impedance Differential Relay\n\n. See product instruction manual appendix A dated 20240308 for more details regarding the SEL-751 Feeder Protection Relay. For more information for the other affected products, see their instruction manuals dated 20240329.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1242", "description": "CWE-1242: Inclusion of Undocumented Features", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-04T15:57:14.010Z", "orgId": "5804bb70-792c-43e0-8596-486cc0efe699", "shortName": "SEL" }, "references": [ { "url": "https://selinc.com/support/security-notifications/external-reports/" } ], "source": { "discovery": "EXTERNAL" }, "title": "Inclusion of Undocumented Features", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699", "assignerShortName": "SEL", "cveId": "CVE-2024-2103", "datePublished": "2024-04-04T15:18:01.645Z", "dateReserved": "2024-03-01T16:25:22.105Z", "dateUpdated": "2024-08-01T19:03:39.137Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }