CWE-1242

Inclusion of Undocumented Features or Chicken Bits

The device includes chicken bits or undocumented features that can create entry points for unauthorized actors.

CVE-2017-20204 (GCVE-0-2017-20204)

Vulnerability from cvelistv5 – Published: 2025-10-15 01:20 – Updated: 2025-10-15 19:56
VLAI?
Summary
DBLTek GoIP devices (models GoIP 1, 4, 8, 16, and 32) contain an undocumented vendor backdoor in the Telnet administrative interface that allows remote authentication as an undocumented user via a proprietary challenge–response scheme which is fundamentally flawed. Because the challenge response can be computed from the challenge itself, a remote attacker can authenticate without knowledge of a secret and obtain a root shell on the device. This can lead to persistent remote code execution, full device compromise, and arbitrary control of the device and any managed services. The firmware used within these devices was updated in December 2016 to make this vulnerability more complex to exploit. However, it is unknown if DBLTek has taken steps to fully mitigate.
CWE
  • CWE-1242 - Inclusion of Undocumented Features or Chicken Bits
Assigner
Impacted products
Credits
SpiderLabs/Trustwave/LevelBlue
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2017-20204",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-15T19:53:59.880259Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-15T19:56:35.584Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GoIP",
          "vendor": "DBL Technology (DBLTek)",
          "versions": [
            {
              "status": "affected",
              "version": "*"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "SpiderLabs/Trustwave/LevelBlue"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "DBLTek GoIP devices (models GoIP 1, 4, 8, 16, and 32) contain an undocumented vendor backdoor in the Telnet administrative interface that allows remote authentication as an undocumented user via a proprietary challenge\u2013response scheme which is fundamentally flawed. Because the challenge response can be computed from the challenge itself, a remote attacker can authenticate without knowledge of a secret and obtain a root shell on the device. This can lead to persistent remote code execution, full device compromise, and arbitrary control of the device and any managed services. The firmware used within these devices was updated in December 2016 to make this vulnerability more complex to exploit. However, it is unknown if DBLTek has taken steps to fully mitigate."
            }
          ],
          "value": "DBLTek GoIP devices (models GoIP 1, 4, 8, 16, and 32) contain an undocumented vendor backdoor in the Telnet administrative interface that allows remote authentication as an undocumented user via a proprietary challenge\u2013response scheme which is fundamentally flawed. Because the challenge response can be computed from the challenge itself, a remote attacker can authenticate without knowledge of a secret and obtain a root shell on the device. This can lead to persistent remote code execution, full device compromise, and arbitrary control of the device and any managed services. The firmware used within these devices was updated in December 2016 to make this vulnerability more complex to exploit. However, it is unknown if DBLTek has taken steps to fully mitigate."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-443",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-443 Malicious Logic Inserted Into Product by Authorized Developer"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1242",
              "description": "CWE-1242 Inclusion of Undocumented Features or Chicken Bits",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-15T01:20:42.502Z",
        "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "shortName": "VulnCheck"
      },
      "references": [
        {
          "tags": [
            "product"
          ],
          "url": "http://www.dbltek.com/"
        },
        {
          "tags": [
            "technical-description",
            "exploit"
          ],
          "url": "https://www.trustwave.com/en-us/resources/blogs/spiderlabs-blog/undocumented-backdoor-account-in-dbltek-goip/"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/JacobMisirian/DblTekGoIPPwn"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.vulncheck.com/advisories/dbltek-goip-telnet-admin-interface-undocumented-backdoor"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "DBLTek GoIP Telnet Admin Interface Undocumented Backdoor",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
    "assignerShortName": "VulnCheck",
    "cveId": "CVE-2017-20204",
    "datePublished": "2025-10-15T01:20:42.502Z",
    "dateReserved": "2025-10-14T15:02:13.120Z",
    "dateUpdated": "2025-10-15T19:56:35.584Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-4469 (GCVE-0-2021-4469)

Vulnerability from cvelistv5 – Published: 2025-11-14 22:53 – Updated: 2025-11-17 14:38
VLAI?
Summary
Denver SHO-110 IP cameras expose a secondary HTTP service on TCP port 8001 that provides access to a '/snapshot' endpoint without authentication. While the primary web interface on port 80 enforces authentication, the backdoor service allows any remote attacker to retrieve image snapshots by directly requesting the 'snapshot' endpoint. An attacker can repeatedly collect snapshots and reconstruct the camera stream, compromising the confidentiality of the monitored environment.
CWE
  • CWE-306 - Missing Authentication for Critical Function
  • CWE-1242 - Inclusion of Undocumented Features or Chicken Bits
Assigner
Impacted products
Vendor Product Version
Denver SHO-110 Affected: 0
    cpe:2.3:h:denver:i:sho-110:*:*:*:*:*:*:*
Create a notification for this product.
Credits
Ivan Nikolsky (enty8080)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-4469",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-17T14:38:14.369155Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-17T14:38:39.748Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:h:denver:i:sho-110:*:*:*:*:*:*:*"
          ],
          "defaultStatus": "unknown",
          "product": "SHO-110",
          "vendor": "Denver",
          "versions": [
            {
              "status": "affected",
              "version": "0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Ivan Nikolsky (enty8080)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Denver SHO-110 IP cameras expose a secondary HTTP service on TCP port 8001 that provides access to a \u0027/snapshot\u0027 endpoint without authentication. While the primary web interface on port 80 enforces authentication, the backdoor service allows any remote attacker to retrieve image snapshots by directly requesting the \u0027snapshot\u0027 endpoint. An attacker can repeatedly collect snapshots and reconstruct the camera stream, compromising the confidentiality of the monitored environment."
            }
          ],
          "value": "Denver SHO-110 IP cameras expose a secondary HTTP service on TCP port 8001 that provides access to a \u0027/snapshot\u0027 endpoint without authentication. While the primary web interface on port 80 enforces authentication, the backdoor service allows any remote attacker to retrieve image snapshots by directly requesting the \u0027snapshot\u0027 endpoint. An attacker can repeatedly collect snapshots and reconstruct the camera stream, compromising the confidentiality of the monitored environment."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-36",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-36 Using Unpublished Interfaces or Functionality"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-1242",
              "description": "CWE-1242 Inclusion of Undocumented Features or Chicken Bits",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-16T13:06:32.465Z",
        "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "shortName": "VulnCheck"
      },
      "references": [
        {
          "tags": [
            "exploit"
          ],
          "url": "https://www.exploit-db.com/exploits/50162"
        },
        {
          "tags": [
            "product"
          ],
          "url": "http://old.denver.eu/products/smart-home-security/denver-sho-110/c-1024/c-1243/p-3826"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.vulncheck.com/advisories/denver-sho-110-ip-camera-unauthenticated-snapshot-access"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "tags": [
        "unsupported-when-assigned"
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2021-07-29T16:00:00.000Z",
          "value": "ExploitDB-50162 is publicly disclosed."
        }
      ],
      "title": "Denver SHO-110 IP Camera Unauthenticated Snapshot Access",
      "x_generator": {
        "engine": "vulncheck"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
    "assignerShortName": "VulnCheck",
    "cveId": "CVE-2021-4469",
    "datePublished": "2025-11-14T22:53:04.754Z",
    "dateReserved": "2025-11-14T20:33:38.739Z",
    "dateUpdated": "2025-11-17T14:38:39.748Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2024-2103 (GCVE-0-2024-2103)

Vulnerability from cvelistv5 – Published: 2024-04-04 15:18 – Updated: 2024-08-01 19:03
VLAI?
Summary
Inclusion of undocumented features vulnerability accessible when logged on with a privileged access level on the following Schweitzer Engineering Laboratories relays could allow the relay to behave unpredictably: SEL-700BT Motor Bus Transfer Relay, SEL-700G Generator Protection Relay, SEL-710-5 Motor Protection Relay, SEL-751 Feeder Protection Relay, SEL-787-2/-3/-4 Transformer Protection Relay, SEL-787Z High-Impedance Differential Relay . See product instruction manual appendix A dated 20240308 for more details regarding the SEL-751 Feeder Protection Relay. For more information for the other affected products, see their instruction manuals dated 20240329.
CWE
  • CWE-1242 - Inclusion of Undocumented Features
Assigner
SEL
Credits
Anonymous Researcher
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2103",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-04T17:11:57.943227Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:28:59.654Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:03:39.137Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://selinc.com/support/security-notifications/external-reports/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "SEL-700BT Motor Bus Transfer Relay",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R301-V6",
              "status": "affected",
              "version": "R301-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R302-V1",
              "status": "affected",
              "version": "R302-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": " SEL-700G Generator Protection Relay",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R301-V6",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R302-V1",
              "status": "affected",
              "version": "R302-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SEL-710-5 Motor Protection Relay",
          "vendor": "SEL-710-5 Motor Protection Relay",
          "versions": [
            {
              "lessThan": "R302-V1",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SEL-751 Feeder Protection Relay",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R302-V3",
              "status": "affected",
              "version": "R101-V0",
              "versionType": "custom"
            },
            {
              "lessThan": "R400-V2",
              "status": "affected",
              "version": "R400-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SEL-787-2/-3/-4 Transformer Protection Relay",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R302-V1",
              "status": "affected",
              "version": "R100-V0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "SEL-787Z High-Impedance Differential Relay",
          "vendor": "Schweitzer Engineering Laboratories",
          "versions": [
            {
              "lessThan": "R302-V3",
              "status": "affected",
              "version": "R302-V0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Anonymous Researcher"
        }
      ],
      "datePublic": "2024-04-04T15:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\n\nInclusion of undocumented features vulnerability accessible when logged on with a privileged access level on the following Schweitzer Engineering Laboratories relays could allow the relay to behave unpredictably:\u003cbr\u003eSEL-700BT Motor Bus Transfer Relay, SEL-700G Generator Protection Relay, SEL-710-5 Motor Protection Relay, SEL-751 Feeder Protection Relay, SEL-787-2/-3/-4 Transformer Protection Relay, SEL-787Z High-Impedance Differential Relay\u003cbr\u003e\u003cbr\u003e. See product instruction manual appendix A dated 20240308 for more details regarding the SEL-751 Feeder Protection Relay. For more information for the other affected products, see their instruction manuals dated 20240329.\u003cp\u003e\u003cspan style=\"background-color: rgb(252, 252, 252);\"\u003e\u003cbr\u003e\u003c/span\u003e\u003c/p\u003e"
            }
          ],
          "value": "\nInclusion of undocumented features vulnerability accessible when logged on with a privileged access level on the following Schweitzer Engineering Laboratories relays could allow the relay to behave unpredictably:\nSEL-700BT Motor Bus Transfer Relay, SEL-700G Generator Protection Relay, SEL-710-5 Motor Protection Relay, SEL-751 Feeder Protection Relay, SEL-787-2/-3/-4 Transformer Protection Relay, SEL-787Z High-Impedance Differential Relay\n\n. See product instruction manual appendix A dated 20240308 for more details regarding the SEL-751 Feeder Protection Relay. For more information for the other affected products, see their instruction manuals dated 20240329.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1242",
              "description": "CWE-1242: Inclusion of Undocumented Features",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-04T15:57:14.010Z",
        "orgId": "5804bb70-792c-43e0-8596-486cc0efe699",
        "shortName": "SEL"
      },
      "references": [
        {
          "url": "https://selinc.com/support/security-notifications/external-reports/"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Inclusion of Undocumented Features",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5804bb70-792c-43e0-8596-486cc0efe699",
    "assignerShortName": "SEL",
    "cveId": "CVE-2024-2103",
    "datePublished": "2024-04-04T15:18:01.645Z",
    "dateReserved": "2024-03-01T16:25:22.105Z",
    "dateUpdated": "2024-08-01T19:03:39.137Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-52564 (GCVE-0-2024-52564)

Vulnerability from cvelistv5 – Published: 2024-12-05 09:41 – Updated: 2025-01-29 04:55
VLAI?
Summary
Inclusion of undocumented features or chicken bits issue exists in UD-LT1 firmware Ver.2.1.8 and earlier and UD-LT1/EX firmware Ver.2.1.8 and earlier. A remote attacker may disable the firewall function of the affected products. As a result, an arbitrary OS command may be executed and/or configuration settings of the device may be altered.
CWE
  • CWE-1242 - Inclusion of undocumented features or chicken bits
Assigner
Impacted products
Vendor Product Version
I-O DATA DEVICE, INC. UD-LT1 Affected: firmware Ver.2.1.8 and earlier
Create a notification for this product.
    I-O DATA DEVICE, INC. UD-LT1/EX Affected: firmware Ver.2.1.8 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:iodata:ud-lt1_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ud-lt1_firmware",
            "vendor": "iodata",
            "versions": [
              {
                "lessThanOrEqual": "2.1.8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:iodata:ud-lt1\\/ex_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ud-lt1\\/ex_firmware",
            "vendor": "iodata",
            "versions": [
              {
                "lessThanOrEqual": "2.1.8",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-52564",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-06T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-29T04:55:28.107Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "UD-LT1",
          "vendor": "I-O DATA DEVICE, INC.",
          "versions": [
            {
              "status": "affected",
              "version": "firmware Ver.2.1.8 and earlier"
            }
          ]
        },
        {
          "product": "UD-LT1/EX",
          "vendor": "I-O DATA DEVICE, INC.",
          "versions": [
            {
              "status": "affected",
              "version": "firmware Ver.2.1.8 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Inclusion of undocumented features or chicken bits issue exists in UD-LT1 firmware Ver.2.1.8 and earlier and UD-LT1/EX firmware Ver.2.1.8 and earlier. A remote attacker may disable the firewall function of the affected products. As a result, an arbitrary OS command may be executed and/or configuration settings of the device may be altered."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1242",
              "description": "Inclusion of undocumented features or chicken bits",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-05T09:41:39.909Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://www.iodata.jp/support/information/2024/11_ud-lt1/"
        },
        {
          "url": "https://jvn.jp/en/jp/JVN46615026/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2024-52564",
    "datePublished": "2024-12-05T09:41:39.909Z",
    "dateReserved": "2024-11-14T01:18:51.324Z",
    "dateUpdated": "2025-01-29T04:55:28.107Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-54457 (GCVE-0-2024-54457)

Vulnerability from cvelistv5 – Published: 2024-12-18 06:37 – Updated: 2024-12-18 15:28
VLAI?
Summary
Inclusion of undocumented features or chicken bits issue exists in AE1021 firmware versions 2.0.10 and earlier and AE1021PE firmware versions 2.0.10 and earlier, which may allow a logged-in user to enable telnet service.
CWE
  • CWE-1242 - Inclusion of undocumented features or chicken bits
Assigner
Impacted products
Vendor Product Version
FXC Inc. AE1021 Affected: firmware versions 2.0.10 and earlier
Create a notification for this product.
    FXC Inc. AE1021PE Affected: firmware versions 2.0.10 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-54457",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-18T15:25:57.981597Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-18T15:28:14.673Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AE1021",
          "vendor": "FXC Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "firmware versions 2.0.10 and earlier"
            }
          ]
        },
        {
          "product": "AE1021PE",
          "vendor": "FXC Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "firmware versions 2.0.10 and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Inclusion of undocumented features or chicken bits issue exists in AE1021 firmware versions 2.0.10 and earlier and AE1021PE firmware versions 2.0.10 and earlier, which may allow a logged-in user to enable telnet service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1242",
              "description": "Inclusion of undocumented features or chicken bits",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-18T06:37:11.912Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://www.fxc.jp/news/20241213"
        },
        {
          "url": "https://jvn.jp/en/vu/JVNVU91084137/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2024-54457",
    "datePublished": "2024-12-18T06:37:11.912Z",
    "dateReserved": "2024-12-10T07:10:13.893Z",
    "dateUpdated": "2024-12-18T15:28:14.673Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-7011 (GCVE-0-2024-7011)

Vulnerability from cvelistv5 – Published: 2024-09-27 02:45 – Updated: 2024-11-05 20:07
VLAI?
Summary
Sharp NEC Projectors (NP-CB4500UL, NP-CB4500WL, NP-CB4700UL, NP-P525UL, NP-P525UL+, NP-P525ULG, NP-P525ULJL, NP-P525WL, NP-P525WL+, NP-P525WLG, NP-P525WLJL, NP-CG6500UL, NP-CG6500WL, NP-CG6700UL, NP-P605UL, NP-P605UL+, NP-P605ULG, NP-P605ULJL, NP-CA4120X, NP-CA4160W, NP-CA4160X, NP-CA4200U, NP-CA4200W, NP-CA4202W, NP-CA4260X, NP-CA4300X, NP-CA4355X, NP-CD2100U, NP-CD2120X, NP-CD2300X, NP-CR2100X, NP-CR2170W, NP-CR2170X, NP-CR2200U, NP-CR2200W, NP-CR2280X, NP-CR2310X, NP-CR2350X, NP-MC302XG, NP-MC332WG, NP-MC332WJL, NP-MC342XG, NP-MC372X, NP-MC372XG, NP-MC382W, NP-MC382WG, NP-MC422XG, NP-ME342UG, NP-ME372W, NP-ME372WG, NP-ME372WJL, NP-ME382U, NP-ME382UG, NP-ME382UJL, NP-ME402X, NP-ME402XG, NP-ME402XJL, NP-CB4500XL, NP-CG6400UL, NP-CG6400WL, NP-CG6500XL, NP-PE455UL, NP-PE455ULG, NP-PE455WL, NP-PE455WLG, NP-PE505XLG, NP-CB4600U, NP-CF6600U, NP-P474U, NP-P554U, NP-P554U+, NP-P554UG, NP-P554UJL, NP-CG6600UL, NP-P547UL, NP-P547ULG, NP-P547ULJL, NP-P607UL+, NP-P627UL, NP-P627UL+, NP-P627ULG, NP-P627ULJL, NP-PV710UL-B, NP-PV710UL-B1, NP-PV710UL-W, NP-PV710UL-W+, NP-PV710UL-W1, NP-PV730UL-BJL, NP-PV730UL-WJL, NP-PV800UL-B, NP-PV800UL-B+, NP-PV800UL-B1, NP-PV800UL-BJL, NP-PV800UL-W, NP-PV800UL-W+, NP-PV800UL-W1, NP-PV800UL-WJL, NP-CA4200X, NP-CA4265X, NP-CA4300U, NP-CA4300W, NP-CA4305X, NP-CA4400X, NP-CD2125X, NP-CD2200W, NP-CD2300U, NP-CD2310X, NP-CR2105X, NP-CR2200X, NP-CR2205W, NP-CR2300U, NP-CR2300W, NP-CR2315X, NP-CR2400X, NP-MC333XG, NP-MC363XG, NP-MC393WJL, NP-MC423W, NP-MC423WG, NP-MC453X, NP-MC453X, NP-MC453XG, NP-MC453XJL, NP-ME383WG, NP-ME403U, NP-ME403UG, NP-ME403UJL, NP-ME423W, NP-ME423WG, NP-ME423WJL, NP-ME453X, NP-ME453XG, NP-CB4400USL, NP-CB4400WSL, NP-CB4510UL, NP-CB4510WL, NP-CB4510XL, NP-CB4550USL, NP-CB6700UL, NP-CG6510UL, NP-PE456USL, NP-PE456USLG, NP-PE456USLJL, NP-PE456WSLG, NP-PE506UL, NP-PE506ULG, NP-PE506ULJL, NP-PE506WL, NP-PE506WLG, NP-PE506WLJL) allows an attacker to cause a denial-of-service (DoS) condition via SNMP service.
CWE
  • CWE-1242 - Inclusion of Undocumented Features or Chicken Bits
Assigner
NEC
Impacted products
Vendor Product Version
Sharp NEC Display Solutions, Ltd. NP-CB4500UL, NP-CB4500WL, NP-CB4700UL, NP-P525UL, NP-P525UL+, NP-P525ULG, NP-P525ULJL, NP-P525WL, NP-P525WL+, NP-P525WLG, NP-P525WLJL, NP-CG6500UL, NP-CG6500WL, NP-CG6700UL, NP-P605UL, NP-P605UL+, NP-P605ULG, NP-P605ULJL, NP-CA4120X, NP-CA4160W, NP-CA4160X, NP-CA4200U, NP-CA4200W, NP-CA4202W, NP-CA4260X, NP-CA4300X, NP-CA4355X, NP-CD2100U, NP-CD2120X, NP-CD2300X, NP-CR2100X, NP-CR2170W, NP-CR2170X, NP-CR2200U, NP-CR2200W, NP-CR2280X, NP-CR2310X, NP-CR2350X, NP-MC302XG, NP-MC332WG, NP-MC332WJL, NP-MC342XG, NP-MC372X, NP-MC372XG, NP-MC382W, NP-MC382WG, NP-MC422XG, NP-ME342UG, NP-ME372W, NP-ME372WG, NP-ME372WJL, NP-ME382U, NP-ME382UG, NP-ME382UJL, NP-ME402X, NP-ME402XG, NP-ME402XJL, NP-CB4500XL, NP-CG6400UL, NP-CG6400WL, NP-CG6500XL, NP-PE455UL, NP-PE455ULG, NP-PE455WL, NP-PE455WLG, NP-PE505XLG, NP-CB4600U, NP-CF6600U, NP-P474U, NP-P554U, NP-P554U+, NP-P554UG, NP-P554UJL, NP-CG6600UL, NP-P547UL, NP-P547ULG, NP-P547ULJL, NP-P607UL+, NP-P627UL, NP-P627UL+, NP-P627ULG, NP-P627ULJL, NP-PV710UL-B, NP-PV710UL-B1, NP-PV710UL-W, NP-PV710UL-W+, NP-PV710UL-W1, NP-PV730UL-BJL, NP-PV730UL-WJL, NP-PV800UL-B, NP-PV800UL-B+, NP-PV800UL-B1, NP-PV800UL-BJL, NP-PV800UL-W, NP-PV800UL-W+, NP-PV800UL-W1, NP-PV800UL-WJL, NP-CA4200X, NP-CA4265X, NP-CA4300U, NP-CA4300W, NP-CA4305X, NP-CA4400X, NP-CD2125X, NP-CD2200W, NP-CD2300U, NP-CD2310X, NP-CR2105X, NP-CR2200X, NP-CR2205W, NP-CR2300U, NP-CR2300W, NP-CR2315X, NP-CR2400X, NP-MC333XG, NP-MC363XG, NP-MC393WJL, NP-MC423W, NP-MC423WG, NP-MC453X, NP-MC453X, NP-MC453XG, NP-MC453XJL, NP-ME383WG, NP-ME403U, NP-ME403UG, NP-ME403UJL, NP-ME423W, NP-ME423WG, NP-ME423WJL, NP-ME453X, NP-ME453XG, NP-CB4400USL, NP-CB4400WSL, NP-CB4510UL, NP-CB4510WL, NP-CB4510XL, NP-CB4550USL, NP-CB6700UL, NP-CG6510UL, NP-PE456USL, NP-PE456USLG, NP-PE456USLJL, NP-PE456WSLG, NP-PE506UL, NP-PE506ULG, NP-PE506ULJL, NP-PE506WL, NP-PE506WLG, NP-PE506WLJL Affected: all
Create a notification for this product.
Credits
Southern Metropolitan Cemeteries Trust JP Hofmeyr
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-7011",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-27T14:20:39.329947Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-05T20:07:10.772Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "NP-CB4500UL, NP-CB4500WL, NP-CB4700UL, NP-P525UL, NP-P525UL+, NP-P525ULG, NP-P525ULJL, NP-P525WL, NP-P525WL+, NP-P525WLG, NP-P525WLJL, NP-CG6500UL, NP-CG6500WL, NP-CG6700UL, NP-P605UL, NP-P605UL+, NP-P605ULG, NP-P605ULJL, NP-CA4120X, NP-CA4160W, NP-CA4160X, NP-CA4200U, NP-CA4200W, NP-CA4202W, NP-CA4260X, NP-CA4300X, NP-CA4355X, NP-CD2100U, NP-CD2120X, NP-CD2300X, NP-CR2100X, NP-CR2170W, NP-CR2170X, NP-CR2200U, NP-CR2200W, NP-CR2280X, NP-CR2310X, NP-CR2350X, NP-MC302XG, NP-MC332WG, NP-MC332WJL, NP-MC342XG, NP-MC372X, NP-MC372XG, NP-MC382W, NP-MC382WG, NP-MC422XG, NP-ME342UG, NP-ME372W, NP-ME372WG, NP-ME372WJL, NP-ME382U, NP-ME382UG, NP-ME382UJL, NP-ME402X, NP-ME402XG, NP-ME402XJL, NP-CB4500XL, NP-CG6400UL, NP-CG6400WL, NP-CG6500XL, NP-PE455UL, NP-PE455ULG, NP-PE455WL, NP-PE455WLG, NP-PE505XLG, NP-CB4600U, NP-CF6600U, NP-P474U, NP-P554U, NP-P554U+, NP-P554UG, NP-P554UJL, NP-CG6600UL, NP-P547UL, NP-P547ULG, NP-P547ULJL, NP-P607UL+, NP-P627UL, NP-P627UL+, NP-P627ULG, NP-P627ULJL, NP-PV710UL-B, NP-PV710UL-B1, NP-PV710UL-W, NP-PV710UL-W+, NP-PV710UL-W1, NP-PV730UL-BJL, NP-PV730UL-WJL, NP-PV800UL-B, NP-PV800UL-B+, NP-PV800UL-B1, NP-PV800UL-BJL, NP-PV800UL-W, NP-PV800UL-W+, NP-PV800UL-W1, NP-PV800UL-WJL, NP-CA4200X, NP-CA4265X, NP-CA4300U, NP-CA4300W, NP-CA4305X, NP-CA4400X, NP-CD2125X, NP-CD2200W, NP-CD2300U, NP-CD2310X, NP-CR2105X, NP-CR2200X, NP-CR2205W, NP-CR2300U, NP-CR2300W, NP-CR2315X, NP-CR2400X, NP-MC333XG, NP-MC363XG, NP-MC393WJL, NP-MC423W, NP-MC423WG, NP-MC453X, NP-MC453X, NP-MC453XG, NP-MC453XJL, NP-ME383WG, NP-ME403U, NP-ME403UG, NP-ME403UJL, NP-ME423W, NP-ME423WG, NP-ME423WJL, NP-ME453X, NP-ME453XG, NP-CB4400USL, NP-CB4400WSL, NP-CB4510UL, NP-CB4510WL, NP-CB4510XL, NP-CB4550USL, NP-CB6700UL, NP-CG6510UL, NP-PE456USL, NP-PE456USLG, NP-PE456USLJL, NP-PE456WSLG, NP-PE506UL, NP-PE506ULG, NP-PE506ULJL, NP-PE506WL, NP-PE506WLG, NP-PE506WLJL",
          "vendor": "Sharp NEC Display Solutions, Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Southern Metropolitan Cemeteries Trust JP Hofmeyr"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eSharp NEC Projectors (NP-CB4500UL, NP-CB4500WL, NP-CB4700UL, NP-P525UL, NP-P525UL+, NP-P525ULG, NP-P525ULJL, NP-P525WL, NP-P525WL+, NP-P525WLG, NP-P525WLJL, NP-CG6500UL, NP-CG6500WL, NP-CG6700UL, NP-P605UL, NP-P605UL+, NP-P605ULG, NP-P605ULJL, NP-CA4120X, NP-CA4160W, NP-CA4160X, NP-CA4200U, NP-CA4200W, NP-CA4202W, NP-CA4260X, NP-CA4300X, NP-CA4355X, NP-CD2100U, NP-CD2120X, NP-CD2300X, NP-CR2100X, NP-CR2170W, NP-CR2170X, NP-CR2200U, NP-CR2200W, NP-CR2280X, NP-CR2310X, NP-CR2350X, NP-MC302XG, NP-MC332WG, NP-MC332WJL, NP-MC342XG, NP-MC372X, NP-MC372XG, NP-MC382W, NP-MC382WG, NP-MC422XG, NP-ME342UG, NP-ME372W, NP-ME372WG, NP-ME372WJL, NP-ME382U, NP-ME382UG, NP-ME382UJL, NP-ME402X, NP-ME402XG, NP-ME402XJL, NP-CB4500XL, NP-CG6400UL, NP-CG6400WL, NP-CG6500XL, NP-PE455UL, NP-PE455ULG, NP-PE455WL, NP-PE455WLG, NP-PE505XLG, NP-CB4600U, NP-CF6600U, NP-P474U, NP-P554U, NP-P554U+, NP-P554UG, NP-P554UJL, NP-CG6600UL, NP-P547UL, NP-P547ULG, NP-P547ULJL, NP-P607UL+, NP-P627UL, NP-P627UL+, NP-P627ULG, NP-P627ULJL, NP-PV710UL-B, NP-PV710UL-B1, NP-PV710UL-W, NP-PV710UL-W+, NP-PV710UL-W1, NP-PV730UL-BJL, NP-PV730UL-WJL, NP-PV800UL-B, NP-PV800UL-B+, NP-PV800UL-B1, NP-PV800UL-BJL, NP-PV800UL-W, NP-PV800UL-W+, NP-PV800UL-W1, NP-PV800UL-WJL, NP-CA4200X, NP-CA4265X, NP-CA4300U, NP-CA4300W, NP-CA4305X, NP-CA4400X, NP-CD2125X, NP-CD2200W, NP-CD2300U, NP-CD2310X, NP-CR2105X, NP-CR2200X, NP-CR2205W, NP-CR2300U, NP-CR2300W, NP-CR2315X, NP-CR2400X, NP-MC333XG, NP-MC363XG, NP-MC393WJL, NP-MC423W, NP-MC423WG, NP-MC453X, NP-MC453X, NP-MC453XG, NP-MC453XJL, NP-ME383WG, NP-ME403U, NP-ME403UG, NP-ME403UJL, NP-ME423W, NP-ME423WG, NP-ME423WJL, NP-ME453X, NP-ME453XG, NP-CB4400USL, NP-CB4400WSL, NP-CB4510UL, NP-CB4510WL, NP-CB4510XL, NP-CB4550USL, NP-CB6700UL, NP-CG6510UL, NP-PE456USL, NP-PE456USLG, NP-PE456USLJL, NP-PE456WSLG, NP-PE506UL, NP-PE506ULG, NP-PE506ULJL, NP-PE506WL, NP-PE506WLG, NP-PE506WLJL) allows an attacker to cause a denial-of-service (DoS) condition via SNMP service.\u003c/p\u003e"
            }
          ],
          "value": "Sharp NEC Projectors (NP-CB4500UL, NP-CB4500WL, NP-CB4700UL, NP-P525UL, NP-P525UL+, NP-P525ULG, NP-P525ULJL, NP-P525WL, NP-P525WL+, NP-P525WLG, NP-P525WLJL, NP-CG6500UL, NP-CG6500WL, NP-CG6700UL, NP-P605UL, NP-P605UL+, NP-P605ULG, NP-P605ULJL, NP-CA4120X, NP-CA4160W, NP-CA4160X, NP-CA4200U, NP-CA4200W, NP-CA4202W, NP-CA4260X, NP-CA4300X, NP-CA4355X, NP-CD2100U, NP-CD2120X, NP-CD2300X, NP-CR2100X, NP-CR2170W, NP-CR2170X, NP-CR2200U, NP-CR2200W, NP-CR2280X, NP-CR2310X, NP-CR2350X, NP-MC302XG, NP-MC332WG, NP-MC332WJL, NP-MC342XG, NP-MC372X, NP-MC372XG, NP-MC382W, NP-MC382WG, NP-MC422XG, NP-ME342UG, NP-ME372W, NP-ME372WG, NP-ME372WJL, NP-ME382U, NP-ME382UG, NP-ME382UJL, NP-ME402X, NP-ME402XG, NP-ME402XJL, NP-CB4500XL, NP-CG6400UL, NP-CG6400WL, NP-CG6500XL, NP-PE455UL, NP-PE455ULG, NP-PE455WL, NP-PE455WLG, NP-PE505XLG, NP-CB4600U, NP-CF6600U, NP-P474U, NP-P554U, NP-P554U+, NP-P554UG, NP-P554UJL, NP-CG6600UL, NP-P547UL, NP-P547ULG, NP-P547ULJL, NP-P607UL+, NP-P627UL, NP-P627UL+, NP-P627ULG, NP-P627ULJL, NP-PV710UL-B, NP-PV710UL-B1, NP-PV710UL-W, NP-PV710UL-W+, NP-PV710UL-W1, NP-PV730UL-BJL, NP-PV730UL-WJL, NP-PV800UL-B, NP-PV800UL-B+, NP-PV800UL-B1, NP-PV800UL-BJL, NP-PV800UL-W, NP-PV800UL-W+, NP-PV800UL-W1, NP-PV800UL-WJL, NP-CA4200X, NP-CA4265X, NP-CA4300U, NP-CA4300W, NP-CA4305X, NP-CA4400X, NP-CD2125X, NP-CD2200W, NP-CD2300U, NP-CD2310X, NP-CR2105X, NP-CR2200X, NP-CR2205W, NP-CR2300U, NP-CR2300W, NP-CR2315X, NP-CR2400X, NP-MC333XG, NP-MC363XG, NP-MC393WJL, NP-MC423W, NP-MC423WG, NP-MC453X, NP-MC453X, NP-MC453XG, NP-MC453XJL, NP-ME383WG, NP-ME403U, NP-ME403UG, NP-ME403UJL, NP-ME423W, NP-ME423WG, NP-ME423WJL, NP-ME453X, NP-ME453XG, NP-CB4400USL, NP-CB4400WSL, NP-CB4510UL, NP-CB4510WL, NP-CB4510XL, NP-CB4550USL, NP-CB6700UL, NP-CG6510UL, NP-PE456USL, NP-PE456USLG, NP-PE456USLJL, NP-PE456WSLG, NP-PE506UL, NP-PE506ULG, NP-PE506ULJL, NP-PE506WL, NP-PE506WLG, NP-PE506WLJL) allows an attacker to cause a denial-of-service (DoS) condition via SNMP service."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1242",
              "description": "CWE-1242: Inclusion of Undocumented Features or Chicken Bits",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-27T02:45:05.979Z",
        "orgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282",
        "shortName": "NEC"
      },
      "references": [
        {
          "url": "https://www.sharp-nec-displays.com/global/support/info/Projector_vulnerability_202408.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282",
    "assignerShortName": "NEC",
    "cveId": "CVE-2024-7011",
    "datePublished": "2024-09-27T02:45:05.979Z",
    "dateReserved": "2024-07-23T04:53:07.799Z",
    "dateUpdated": "2024-11-05T20:07:10.772Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-12176 (GCVE-0-2025-12176)

Vulnerability from cvelistv5 – Published: 2025-10-24 15:56 – Updated: 2025-10-24 19:56
VLAI?
Summary
Undocumented administrative accounts were getting created to facilitate access for applications running on board.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5.
CWE
  • CWE-1242 - Inclusion of Undocumented Features or Chicken Bits
Assigner
Impacted products
Vendor Product Version
Azure Access Technology BLU-IC2 Affected: 0 , ≤ 1.19.5 (semver)
Create a notification for this product.
Credits
Kevin Schaller Benjamin Lafois Alexi Bitsios Sebastian Toscano Dominik Schneider
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12176",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-24T16:41:48.448092Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-24T19:56:09.959Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "BLU-IC2",
          "vendor": "Azure Access Technology",
          "versions": [
            {
              "lessThanOrEqual": "1.19.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "BLU-IC4",
          "vendor": "Azure Access Technology",
          "versions": [
            {
              "lessThanOrEqual": "1.19.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Kevin Schaller"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Benjamin Lafois"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Alexi Bitsios"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Sebastian Toscano"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Dominik Schneider"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Undocumented administrative accounts were getting created to facilitate access for applications running on board.\u003cp\u003eThis issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5.\u003c/p\u003e"
            }
          ],
          "value": "Undocumented administrative accounts were getting created to facilitate access for applications running on board.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-36",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-36 Using Unpublished Interfaces or Functionality"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1242",
              "description": "CWE-1242: Inclusion of Undocumented Features or Chicken Bits",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-24T15:56:07.959Z",
        "orgId": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
        "shortName": "azure-access"
      },
      "references": [
        {
          "url": "https://azure-access.com/security-advisories"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Undocumented Administrative Accounts",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0340c66-c385-4f8b-991b-3d05f6fd5220",
    "assignerShortName": "azure-access",
    "cveId": "CVE-2025-12176",
    "datePublished": "2025-10-24T15:56:07.959Z",
    "dateReserved": "2025-10-24T15:51:46.644Z",
    "dateUpdated": "2025-10-24T19:56:09.959Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-22450 (GCVE-0-2025-22450)

Vulnerability from cvelistv5 – Published: 2025-01-22 05:49 – Updated: 2025-02-12 20:41
VLAI?
Summary
Inclusion of undocumented features issue exists in UD-LT2 firmware Ver.1.00.008_SE and earlier. A remote attacker may disable the LAN-side firewall function of the affected products, and open specific ports.
CWE
  • CWE-1242 - Inclusion of undocumented features or chicken bits
Assigner
Impacted products
Vendor Product Version
I-O DATA DEVICE, INC. UD-LT2 Affected: firmware Ver.1.00.008_SE and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-22450",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-22T14:33:09.160199Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-12T20:41:22.761Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "UD-LT2",
          "vendor": "I-O DATA DEVICE, INC.",
          "versions": [
            {
              "status": "affected",
              "version": "firmware Ver.1.00.008_SE and earlier"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Inclusion of undocumented features issue exists in UD-LT2 firmware Ver.1.00.008_SE and earlier. A remote attacker may disable the LAN-side firewall function of the affected products, and open specific ports."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1242",
              "description": "Inclusion of undocumented features or chicken bits",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-22T05:49:13.793Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "url": "https://www.iodata.jp/support/information/2025/01_ud-lt2/"
        },
        {
          "url": "https://jvn.jp/en/jp/JVN15293958/"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2025-22450",
    "datePublished": "2025-01-22T05:49:13.793Z",
    "dateReserved": "2025-01-16T07:05:53.738Z",
    "dateUpdated": "2025-02-12T20:41:22.761Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-52548 (GCVE-0-2025-52548)

Vulnerability from cvelistv5 – Published: 2025-09-02 11:26 – Updated: 2025-09-02 13:28
VLAI?
Summary
E3 Site Supervisor Control (firmware version < 2.31F01) contains a hidden API call in the application services that enables SSH and Shellinabox, which exist but are disabled by default. An attacker with admin access to the application services can utilize this API to enable remote access to the underlying OS.
CWE
Assigner
Impacted products
Vendor Product Version
Copeland LP E3 Supervisory Control Affected: 0 , < 2.31F01 (firmware)
Create a notification for this product.
Credits
Armis Labs
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-52548",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-02T13:27:58.507057Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-02T13:28:08.207Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "E3 Supervisory Control",
          "vendor": "Copeland LP",
          "versions": [
            {
              "lessThan": "2.31F01",
              "status": "affected",
              "version": "0",
              "versionType": "firmware"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Armis Labs"
        }
      ],
      "datePublic": "2025-07-29T12:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "E3 Site Supervisor Control (firmware version \u0026lt; 2.31F01) contains a hidden API call in the application services that enables SSH and Shellinabox, which exist but are disabled by default. An attacker with admin access to the application services can utilize this API to enable remote access to the underlying OS."
            }
          ],
          "value": "E3 Site Supervisor Control (firmware version \u003c 2.31F01) contains a hidden API call in the application services that enables SSH and Shellinabox, which exist but are disabled by default. An attacker with admin access to the application services can utilize this API to enable remote access to the underlying OS."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1242",
              "description": "CWE-1242",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-02T11:26:08.636Z",
        "orgId": "dd59f033-460c-4b88-a075-d4d3fedb6191",
        "shortName": "Armis"
      },
      "references": [
        {
          "url": "https://www.armis.com/research/frostbyte10/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade firmware of affected E3 Supervisory Controls to a version \u0026gt; 2.30F1.\u003cbr\u003e"
            }
          ],
          "value": "Upgrade firmware of affected E3 Supervisory Controls to a version \u003e 2.30F1."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Enabling SSH and Shellinabox on the vulnerable machine",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Restrict access to the E3 Supervisory Controls network interface (ETH 0) by use of restricted VLAN or subnet and / or network firewall. Ensure the restricted VLAN or subnet is never accessible from untrusted networks."
            }
          ],
          "value": "Restrict access to the E3 Supervisory Controls network interface (ETH 0) by use of restricted VLAN or subnet and / or network firewall. Ensure the restricted VLAN or subnet is never accessible from untrusted networks."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dd59f033-460c-4b88-a075-d4d3fedb6191",
    "assignerShortName": "Armis",
    "cveId": "CVE-2025-52548",
    "datePublished": "2025-09-02T11:26:08.636Z",
    "dateReserved": "2025-06-17T17:29:21.841Z",
    "dateUpdated": "2025-09-02T13:28:08.207Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-55050 (GCVE-0-2025-55050)

Vulnerability from cvelistv5 – Published: 2025-09-09 18:56 – Updated: 2025-09-10 14:29
VLAI?
Summary
CWE-1242: Inclusion of Undocumented Features
CWE
Assigner
Impacted products
Vendor Product Version
Baicells NOVA430e/430i, NOVA436Q, NEUTRINO430, NOVA846 Affected: BaiBLQ_3.0.12 and older versions. BaiBU_DNB4_2.4.9 and older versions
Create a notification for this product.
Credits
Shahaf Levi
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-55050",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-10T14:14:42.350737Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-10T14:29:16.462Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "NOVA430e/430i, NOVA436Q, NEUTRINO430, NOVA846",
          "vendor": "Baicells",
          "versions": [
            {
              "status": "affected",
              "version": "BaiBLQ_3.0.12 and older versions. BaiBU_DNB4_2.4.9 and older versions"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Shahaf Levi"
        }
      ],
      "datePublic": "2025-09-09T18:52:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "CWE-1242: Inclusion of Undocumented Features"
            }
          ],
          "value": "CWE-1242: Inclusion of Undocumented Features"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1242",
              "description": "CWE-1242",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-09T18:56:59.092Z",
        "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "shortName": "INCD"
      },
      "references": [
        {
          "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
        }
      ],
      "source": {
        "advisory": "ILVN-2025-0243",
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
    "assignerShortName": "INCD",
    "cveId": "CVE-2025-55050",
    "datePublished": "2025-09-09T18:56:59.092Z",
    "dateReserved": "2025-08-06T11:04:25.088Z",
    "dateUpdated": "2025-09-10T14:29:16.462Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation

Phases: Architecture and Design, Implementation

Description:

  • The implementation of chicken bits in a released product is highly discouraged. If implemented at all, ensure that they are disabled in production devices. All interfaces to a device should be documented.
CAPEC-212: Functionality Misuse

An adversary leverages a legitimate capability of an application in such a way as to achieve a negative technical impact. The system functionality is not altered or modified but used in a way that was not intended. This is often accomplished through the overuse of a specific functionality or by leveraging functionality with design flaws that enables the adversary to gain access to unauthorized, sensitive data.

CAPEC-36: Using Unpublished Interfaces or Functionality

An adversary searches for and invokes interfaces or functionality that the target system designers did not intend to be publicly available. If interfaces fail to authenticate requests, the attacker may be able to invoke functionality they are not authorized for.

Back to CWE stats page