All the vulnerabilites related to Siemens - SIMATIC ET200ecoPN, DI 16x24VDC, M12-L
cve-2019-19300
Vulnerability from cvelistv5
Published
2020-04-14 00:00
Modified
2024-08-05 02:16
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, KTK ATE530S, SIDOOR ATD430W, SIDOOR ATE530S COATED, SIDOOR ATE531S, SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0), SIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0), SIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0), SIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0), SIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0), SIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0), SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants), SIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0), SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0), SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0), SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0), SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0), SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0), SIMATIC MICRO-DRIVE PDC, SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0), SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0), SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0), SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0), SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0), SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0), SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0), SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0), SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0), SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0), SIMATIC S7-400 H V6 and below CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0), SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0), SINAMICS S/G Control Unit w. PROFINET, SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0), SIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0), SIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0), SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0), SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0), SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0), SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0), SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0). The Interniche-based TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:16:46.943Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-593272.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-593272.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "KTK ATE530S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIDOOR ATD430W", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIDOOR ATE530S COATED", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIDOOR ATE531S", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 MF HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/2 HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/3 HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V5.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V5.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V5.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DI 16x24VDC, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DI 8x24VDC, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.3", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC MICRO-DRIVE PDC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/MF Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V4.2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V4.4.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 Software Controller", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315T-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317T-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319F-3 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6\u00a0and below\u00a0CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S/G Control Unit w. PROFINET", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V4.2" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P, KTK ATE530S, SIDOOR ATD430W, SIDOOR ATE530S COATED, SIDOOR ATE531S, SIMATIC ET 200AL IM 157-1 PN (6ES7157-1AB00-0AB0), SIMATIC ET 200MP IM 155-5 PN HF (6ES7155-5AA00-0AC0), SIMATIC ET 200pro IM 154-8 PN/DP CPU (6ES7154-8AB01-0AB0), SIMATIC ET 200pro IM 154-8F PN/DP CPU (6ES7154-8FB01-0AB0), SIMATIC ET 200pro IM 154-8FX PN/DP CPU (6ES7154-8FX00-0AB0), SIMATIC ET 200S IM 151-8 PN/DP CPU (6ES7151-8AB01-0AB0), SIMATIC ET 200S IM 151-8F PN/DP CPU (6ES7151-8FB01-0AB0), SIMATIC ET 200SP IM 155-6 MF HF (6ES7155-6MU00-0CN0), SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants), SIMATIC ET 200SP IM 155-6 PN HF (6ES7155-6AU00-0CN0), SIMATIC ET 200SP IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0), SIMATIC ET 200SP IM 155-6 PN/3 HF (6ES7155-6AU30-0CN0), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants), SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L (6ES7144-6JF00-0BB0), SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L (6ES7148-6JE00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L (6ES7148-6JJ00-0BB0), SIMATIC ET200ecoPN, DI 16x24VDC, M12-L (6ES7141-6BH00-0BB0), SIMATIC ET200ecoPN, DI 8x24VDC, M12-L (6ES7141-6BG00-0BB0), SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L (6ES7143-6BH00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L (6ES7142-6BG00-0BB0), SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L (6ES7142-6BR00-0BB0), SIMATIC MICRO-DRIVE PDC, SIMATIC PN/MF Coupler (6ES7158-3MU10-0XA0), SIMATIC PN/PN Coupler (6ES7158-3AD10-0XA0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants), SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0), SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0), SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0), SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0), SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0), SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0), SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0), SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0), SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0), SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0), SIMATIC S7-400 H V6\u00a0and below\u00a0CPU family (incl. SIPLUS variants), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX 2010 (6ES7671-0RC08-0YA0), SIMATIC WinAC RTX F 2010 (6ES7671-1RC08-0YA0), SINAMICS S/G Control Unit w. PROFINET, SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-2AC0), SIPLUS ET 200MP IM 155-5 PN HF (6AG1155-5AA00-7AC0), SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL (6AG2155-5AA00-1AC0), SIPLUS ET 200S IM 151-8 PN/DP CPU (6AG1151-8AB01-7AB0), SIPLUS ET 200S IM 151-8F PN/DP CPU (6AG1151-8FB01-2AB0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU00-4CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-2CN0), SIPLUS ET 200SP IM 155-6 PN HF (6AG1155-6AU01-7CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU00-1CN0), SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL (6AG2155-6AU01-1CN0), SIPLUS ET 200SP IM 155-6 PN HF TX RAIL (6AG2155-6AU01-4CN0), SIPLUS NET PN/PN Coupler (6AG2158-3AD10-4XA0), SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0), SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0), SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0), SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0), SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0). The Interniche-based TCP Stack can be forced to make very expensive calls for every incoming packet which can lead to a denial of service." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-09T12:03:59.957Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-593272.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-593272.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-19300", "datePublished": "2020-04-14T00:00:00", "dateReserved": "2019-11-26T00:00:00", "dateUpdated": "2024-08-05T02:16:46.943Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-25622
Vulnerability from cvelistv5
Published
2022-04-12 00:00
Modified
2024-08-03 04:42
Severity ?
EPSS score ?
Summary
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.
This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T04:42:50.341Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CFU DIQ", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU PA", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 MF HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/2 HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/3 HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V5.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V5.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V5.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DI 16x24VDC, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DI 8x24VDC, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.3", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/MF Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= 4.2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 412-2 PN V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.10", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V10.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V8.2.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.10", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "V1.2.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM", "vendor": "Siemens", "versions": [ { "lessThan": "V1.5 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M", "vendor": "Siemens", "versions": [ { "lessThan": "V4.7.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G115D", "vendor": "Siemens", "versions": [ { "lessThan": "V4.7.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.7 SP14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.3.13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.3.13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2 SP3 HF13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.3.13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S210 (6SL5...)", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2 SP3 HF18", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS V90", "vendor": "Siemens", "versions": [ { "lessThan": "V1.04.04", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS HCS4200 CIM4210", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS HCS4200 CIM4210C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS HCS4300 CIM4310", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= 4.2" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.\n\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-09T12:04:01.924Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-25622", "datePublished": "2022-04-12T00:00:00", "dateReserved": "2022-02-21T00:00:00", "dateUpdated": "2024-08-03T04:42:50.341Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }