cve-2022-25622
Vulnerability from cvelistv5
Published
2022-04-12 00:00
Modified
2024-08-03 04:42
Severity ?
EPSS score ?
Summary
The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.
This could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T04:42:50.341Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf" }, { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC CFU DIQ", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC CFU PA", "vendor": "Siemens", "versions": [ { "lessThan": "V2.0.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200AL IM 157-1 PN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200pro IM 154-8FX PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 MF HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HA (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/2 HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET 200SP IM 155-6 PN/3 HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, AI 8xRTD/TC, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, CM 4x IO-Link, M12-L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V5.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V5.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= V5.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DI 16x24VDC, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DI 8x24VDC, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.3", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L", "vendor": "Siemens", "versions": [ { "lessThan": "V5.1.2", "status": "affected", "version": "V5.1.1", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/MF Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= 4.2" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0.0" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 315T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317T-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 317TF-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-300 CPU 319F-3 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 412-2 PN V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 414F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 CPU 416F-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V6.0.10", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 V10 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V10.1.1" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V8.2.3", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CP51M1", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1.10", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC TDC CPU555", "vendor": "Siemens", "versions": [ { "lessThan": "V1.2.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC WinAC RTX F 2010", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS DCM", "vendor": "Siemens", "versions": [ { "lessThan": "V1.5 SP1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G110M", "vendor": "Siemens", "versions": [ { "lessThan": "V4.7.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G115D", "vendor": "Siemens", "versions": [ { "lessThan": "V4.7.14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G120 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V4.7 SP14", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G130", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.3.13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS G150", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.3.13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S110", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S120 (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2 SP3 HF13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S150", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2.3.13", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS S210 (6SL5...)", "vendor": "Siemens", "versions": [ { "lessThan": "V5.2 SP3 HF18", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SINAMICS V90", "vendor": "Siemens", "versions": [ { "lessThan": "V1.04.04", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8 PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200S IM 151-8F PN/DP CPU", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS ET 200SP IM 155-6 PN HF TX RAIL", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "V4.2.0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS HCS4200 CIM4210", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS HCS4200 CIM4210C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS HCS4300 CIM4310", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS NET PN/PN Coupler", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e= 4.2" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 314C-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.3.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 315F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-300 CPU 317F-2 PN/DP", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.2.19" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 414-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIPLUS S7-400 CPU 416-3 PN/DP V7", "vendor": "Siemens", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.\n\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-07-09T12:04:01.924Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf" }, { "url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-25622", "datePublished": "2022-04-12T00:00:00", "dateReserved": "2022-02-21T00:00:00", "dateUpdated": "2024-08-03T04:42:50.341Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2022-25622\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-04-12T09:15:14.483\",\"lastModified\":\"2024-07-09T12:15:05.463\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined.\\n\\nThis could allow an attacker to create a denial of service condition for TCP services on affected devices by sending specially crafted TCP segments.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC CFU DIQ, SIMATIC CFU PA, SIMATIC ET 200S IM151-8 PN/DP CPU, SIMATIC ET 200S IM151-8F PN/DP CPU, SIMATIC ET 200pro IM154-8 PN/DP CPU, SIMATIC ET 200pro IM154-8F PN/DP CPU, SIMATIC ET 200pro IM154-8FX PN/DP CPU, SIMATIC ET200AL IM157-1 PN, SIMATIC ET200MP IM155-5 PN HF (incl. SIPLUS), SIMATIC ET200SP IM155-6 MF HF, SIMATIC ET200SP IM155-6 PN HA (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN/2 HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN/3 HF (incl. variantes SIPLUS) variantes SIPLUS), SIMATIC ET200ecoPN, CM 8x IO-Link, M12-L, SIMATIC ET200ecoPN, DI 16x24VDC, M12-L, SIMATIC ET200ecoPN, DI 8x24VDC, M12-L, SIMATIC ET200ecoPN, DIQ 16x24VDC/2A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/0,5A, M12-L, SIMATIC ET200ecoPN, DQ 8x24VDC/2A, M12-L, Acoplador SIMATIC PN/MF, Acoplador SIMATIC PN/PN, familia de CPUs SIMATIC S7-1500 (incl. CPUs ET200 relacionadas y variantes SIPLUS), SIMATIC S7-300 CPU 314C-2 PN/DP, SIMATIC S7-300 CPU 315-2 PN/DP, SIMATIC S7-300 CPU 315F-2 PN/DP, SIMATIC S7-300 CPU 315T-3 PN/DP, SIMATIC S7-300 CPU 317-2 PN/DP, SIMATIC S7-300 CPU 317F-2 PN/DP, SIMATIC S7-300 CPU 317T-3 PN/DP, SIMATIC S7-300 CPU 317TF-3 PN/DP, SIMATIC S7-300 CPU 319-3 PN/DP, SIMATIC S7-300 CPU 319F-3 PN/DP, familia de CPUs SIMATIC S7-300 (incl. CPUs ET200 relacionadas y variantes SIPLUS), familia de CPUs SIMATIC S7-400 H V6 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V7 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-410 V10 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-410 V8 (incl. variantes SIPLUS). variantes SIPLUS), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX, SIMIT Simulation Platform, SINAMICS DCM, SINAMICS G110M, SINAMICS G115D, SINAMICS G120 (incl. variantes SIPLUS), SINAMICS G130, SINAMICS G150, SINAMICS S110, SINAMICS S120 (incl. variantes SIPLUS), SIMATIC S120 (incl. variantes SIPLUS). variantes SIPLUS), SINAMICS S150, SINAMICS S210, SINAMICS V90, SIPLUS ET 200S IM151-8 PN/DP CPU, SIPLUS ET 200S IM151-8F PN/DP CPU, SIPLUS HCS4200 CIM4210, SIPLUS HCS4200 CIM4210C, SIPLUS HCS4300 CIM4310, SIPLUS NET PN/PN Coupler, SIPLUS S7-300 CPU 314C-2 PN/DP, SIPLUS S7-300 CPU 315-2 PN/DP, SIPLUS S7-300 CPU 315F-2 PN/DP, SIPLUS S7-300 CPU 317-2 PN/DP, SIPLUS S7-300 CPU 317F-2 PN/DP. La pila PROFINET (PNIO), cuando se integra con la pila IP de Interniche, maneja incorrectamente los recursos internos para los segmentos TCP en los que la longitud m\u00ednima del TCP-Header es inferior a la definida. Esto podr\u00eda permitir a un atacante crear una condici\u00f3n de denegaci\u00f3n de servicio para los servicios TCP en los dispositivos afectados mediante el env\u00edo de segmentos TCP especialmente dise\u00f1ados\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":5.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cfu_diq_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CF0CF4BB-3200-4942-ADA2-120D348E03A4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cfu_diq:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AF942F59-C13F-40FC-9601-2B4202677CC4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_cfu_pa_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A5119182-CB31-466A-AB0F-7956C8B45AE0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_cfu_pa:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B6C1E4CC-2657-4383-83D8-5C8F88B12755\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E4872DF2-8C81-45BA-A606-99D0A75464AC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"602FB384-0DB2-488C-B3CC-96E3A2882976\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-400h_v6_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6668A57C-BC46-4008-B174-9E557946ACA2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400h_v6:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1D082EB6-3C13-40C1-9949-179DC59037C1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-400_pn\\\\/dp_v7_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EC44664E-830D-4122-A97A-1AFA61F5BBB5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_pn\\\\/dp_v7:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C48D93F2-FB6B-4D4D-84FB-3A7CDE89B727\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-410_v8_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"18E1CA5D-3D7D-49D0-A417-235E2AF6075C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-410_v8:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"926D9DCF-A7EA-416A-9A07-122D1FCA027B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-410_v10_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"70A009DD-9D8A-4FF3-B65C-D1AF477D5CB5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-410_v10:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6F240847-0ADC-475C-BDDF-6483A8FF5602\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.0.0\",\"matchCriteriaId\":\"1ED5EE9B-B05A-4D2A-9FC6-0519E020FFB8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-1500_cpu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"01048F7F-9C5B-47C0-AE16-321FCA670F3D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_tdc_cp51m1_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3E2689E6-A204-4744-827E-EEFB11B7C334\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_tdc_cp51m1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8DA1E7C4-6352-41A4-8A94-C24DDB456572\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_tdc_cpu555_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2D9C7D4A-F989-4B01-8FFD-5B5859F42D43\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_tdc_cpu555:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AE6AB995-D67B-43E5-B8FF-97C38D20CB10\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_winac_rtx_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2E721F4E-2F84-496D-938D-A27F3E53E543\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_winac_rtx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CA5ADAB0-3985-4933-8CDD-D1546D8271CC\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:simit_simulation_platform:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7902D452-4DA8-420E-BD33-5FC112C2F5BE\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-446448.html\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-446448.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.