All the vulnerabilites related to Siemens - SIMATIC Reader RF685R ETSI
var-202106-1490
Vulnerability from variot
A vulnerability has been identified in SIMATIC RF166C (All versions > V1.1 and < V1.3.2), SIMATIC RF185C (All versions > V1.1 and < V1.3.2), SIMATIC RF186C (All versions > V1.1 and < V1.3.2), SIMATIC RF186CI (All versions > V1.1 and < V1.3.2), SIMATIC RF188C (All versions > V1.1 and < V1.3.2), SIMATIC RF188CI (All versions > V1.1 and < V1.3.2), SIMATIC RF360R (All versions < V2.0), SIMATIC Reader RF610R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF610R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF610R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF615R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF615R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF615R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF650R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF650R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF680R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF680R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF685R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF685R FCC (All versions > V3.0 < V4.0). Affected devices do not properly handle large numbers of incoming connections. An attacker may leverage this to cause a Denial-of-Service situation. plural SIMATIC The product contains a resource depletion vulnerability.Denial of service (DoS) It may be put into a state. Pillow is a Python-based image processing library. There is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202106-1490", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "simatic reader rf650r etsi", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "simatic rf186ci", "scope": "gt", "trust": 1.0, "vendor": "siemens", "version": "1.1" }, { "model": "simatic reader rf650r cmiit", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "simatic reader rf615r cmiit", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "simatic reader rf680r etsi", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "simatic reader rf615r etsi", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "simatic reader rf680r fcc", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic reader rf610r etsi", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "simatic rf188c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.3.2" }, { "model": "simatic reader rf680r cmiit", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "simatic reader rf680r arib", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic reader rf615r fcc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "simatic reader rf685r cmiit", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic rf188ci", "scope": "gt", "trust": 1.0, "vendor": "siemens", "version": "1.1" }, { "model": "simatic reader rf650r fcc", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic reader rf685r arib", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic reader rf610r cmiit", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "simatic rf186c", "scope": "gt", "trust": 1.0, "vendor": "siemens", "version": "1.1" }, { "model": "simatic rf185c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.3.2" }, { "model": "simatic reader rf650r cmiit", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic reader rf610r fcc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "simatic rf166c", "scope": "gt", "trust": 1.0, "vendor": "siemens", "version": "1.1" }, { "model": "simatic reader rf685r fcc", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic reader rf650r etsi", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic reader rf650r arib", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "simatic reader rf615r fcc", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic rf188c", "scope": "gt", "trust": 1.0, "vendor": "siemens", "version": "1.1" }, { "model": "simatic reader rf610r etsi", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic reader rf615r etsi", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic reader rf680r etsi", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic reader rf685r etsi", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "simatic rf186ci", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.3.2" }, { "model": "simatic rf186c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.3.2" }, { "model": "simatic reader rf680r cmiit", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic reader rf685r fcc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "simatic reader rf615r cmiit", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic rf185c", "scope": "gt", "trust": 1.0, "vendor": "siemens", "version": "1.1" }, { "model": "simatic rf360r", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "simatic reader rf680r arib", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "simatic reader rf685r cmiit", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "simatic reader rf650r fcc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "simatic reader rf680r fcc", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "simatic reader rf685r etsi", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic rf188ci", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.3.2" }, { "model": "simatic reader rf610r fcc", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic reader rf685r arib", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.0" }, { "model": "simatic reader rf610r cmiit", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic reader rf650r arib", "scope": "gte", "trust": 1.0, "vendor": "siemens", "version": "3.0" }, { "model": "simatic rf166c", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "1.3.2" }, { "model": "simatic rf185c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic rf360r", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic rf685r", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic rf188ci", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic rf680r", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic rf186ci", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic rf188c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic rf615r", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic rf186c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic rf166c", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-008155" }, { "db": "NVD", "id": "CVE-2021-31340" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf166c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2", "versionStartExcluding": "1.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf166c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2", "versionStartExcluding": "1.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf185c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2", "versionStartExcluding": "1.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf186c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf186ci_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2", "versionStartExcluding": "1.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf186ci:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2", "versionStartExcluding": "1.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf188ci_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "1.3.2", "versionStartExcluding": "1.1", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf188ci:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_rf360r_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_rf360r:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_reader_rf610r_cmiit_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0", "versionStartIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_reader_rf610r_cmiit:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_reader_rf610r_etsi_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0", "versionStartIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_reader_rf610r_etsi:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_reader_rf610r_fcc_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0", "versionStartIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_reader_rf610r_fcc:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_reader_rf615r_cmiit_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0", "versionStartIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_reader_rf615r_cmiit:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_reader_rf615r_etsi_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0", "versionStartIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_reader_rf615r_etsi:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_reader_rf615r_fcc_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0", "versionStartIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_reader_rf615r_fcc:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_reader_rf650r_cmiit_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0", "versionStartIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_reader_rf650r_cmiit:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_reader_rf650r_etsi_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0", "versionStartIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_reader_rf650r_etsi:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_reader_rf650r_fcc_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0", "versionStartIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_reader_rf650r_fcc:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_reader_rf650r_arib_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0", "versionStartIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_reader_rf650r_arib:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_reader_rf680r_cmiit_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0", "versionStartIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_reader_rf680r_cmiit:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_reader_rf680r_etsi_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0", "versionStartIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_reader_rf680r_etsi:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_reader_rf680r_fcc_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0", "versionStartIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_reader_rf680r_fcc:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_reader_rf680r_arib_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0", "versionStartIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_reader_rf680r_arib:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_reader_rf685r_cmiit_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0", "versionStartIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_reader_rf685r_cmiit:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_reader_rf685r_etsi_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0", "versionStartIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_reader_rf685r_etsi:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_reader_rf685r_fcc_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0", "versionStartIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_reader_rf685r_fcc:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:simatic_reader_rf685r_arib_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.0", "versionStartIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:simatic_reader_rf685r_arib:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-31340" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens reported this vulnerability to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202106-475" } ], "trust": 0.6 }, "cve": "CVE-2021-31340", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 5.0, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 5.0, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-31340", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2021-31340", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-31340", "trust": 1.8, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202106-475", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-31340", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-31340" }, { "db": "JVNDB", "id": "JVNDB-2021-008155" }, { "db": "NVD", "id": "CVE-2021-31340" }, { "db": "CNNVD", "id": "CNNVD-202106-475" }, { "db": "CNNVD", "id": "CNNVD-202104-975" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC RF166C (All versions \u003e V1.1 and \u003c V1.3.2), SIMATIC RF185C (All versions \u003e V1.1 and \u003c V1.3.2), SIMATIC RF186C (All versions \u003e V1.1 and \u003c V1.3.2), SIMATIC RF186CI (All versions \u003e V1.1 and \u003c V1.3.2), SIMATIC RF188C (All versions \u003e V1.1 and \u003c V1.3.2), SIMATIC RF188CI (All versions \u003e V1.1 and \u003c V1.3.2), SIMATIC RF360R (All versions \u003c V2.0), SIMATIC Reader RF610R CMIIT (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF610R ETSI (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF610R FCC (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF615R CMIIT (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF615R ETSI (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF615R FCC (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF650R ARIB (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF650R CMIIT (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF650R ETSI (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF650R FCC (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF680R ARIB (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF680R CMIIT (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF680R ETSI (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF680R FCC (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF685R ARIB (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF685R CMIIT (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF685R ETSI (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF685R FCC (All versions \u003e V3.0 \u003c V4.0). Affected devices do not properly handle large numbers of incoming connections. An attacker may leverage this to cause a Denial-of-Service situation. plural SIMATIC The product contains a resource depletion vulnerability.Denial of service (DoS) It may be put into a state. Pillow is a Python-based image processing library. \nThere is currently no information about this vulnerability, please feel free to follow CNNVD or manufacturer announcements", "sources": [ { "db": "NVD", "id": "CVE-2021-31340" }, { "db": "JVNDB", "id": "JVNDB-2021-008155" }, { "db": "CNNVD", "id": "CNNVD-202104-975" }, { "db": "VULMON", "id": "CVE-2021-31340" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-31340", "trust": 3.3 }, { "db": "SIEMENS", "id": "SSA-787292", "trust": 1.7 }, { "db": "ICS CERT", "id": "ICSA-21-159-13", "trust": 1.5 }, { "db": "JVN", "id": "JVNVU95781418", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-008155", "trust": 0.8 }, { "db": "CS-HELP", "id": "SB2021061004", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202106-475", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2021041363", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202104-975", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-31340", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-31340" }, { "db": "JVNDB", "id": "JVNDB-2021-008155" }, { "db": "NVD", "id": "CVE-2021-31340" }, { "db": "CNNVD", "id": "CNNVD-202106-475" }, { "db": "CNNVD", "id": "CNNVD-202104-975" } ] }, "id": "VAR-202106-1490", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.493551585 }, "last_update_date": "2023-12-18T11:26:25.354000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-787292", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-787292.pdf" }, { "title": "Siemens SIMATIC Remediation of resource management error vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=154812" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=4afce23c1d098bd5a98b3faa63307634" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-31340" }, { "db": "JVNDB", "id": "JVNDB-2021-008155" }, { "db": "CNNVD", "id": "CNNVD-202106-475" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-400", "trust": 1.0 }, { "problemtype": "Resource exhaustion (CWE-400) [ Other ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-008155" }, { "db": "NVD", "id": "CVE-2021-31340" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-787292.pdf" }, { "trust": 0.9, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-159-13" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu95781418/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-31340" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021061004" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/simatic-rfid-readers-overload-via-incoming-connections-35642" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-13" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2021041363" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/400.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2021-31340" }, { "db": "JVNDB", "id": "JVNDB-2021-008155" }, { "db": "NVD", "id": "CVE-2021-31340" }, { "db": "CNNVD", "id": "CNNVD-202106-475" }, { "db": "CNNVD", "id": "CNNVD-202104-975" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2021-31340" }, { "db": "JVNDB", "id": "JVNDB-2021-008155" }, { "db": "NVD", "id": "CVE-2021-31340" }, { "db": "CNNVD", "id": "CNNVD-202106-475" }, { "db": "CNNVD", "id": "CNNVD-202104-975" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-06-08T00:00:00", "db": "VULMON", "id": "CVE-2021-31340" }, { "date": "2022-03-04T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-008155" }, { "date": "2021-06-08T20:15:08.853000", "db": "NVD", "id": "CVE-2021-31340" }, { "date": "2021-06-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202106-475" }, { "date": "2021-04-13T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-04-12T00:00:00", "db": "VULMON", "id": "CVE-2021-31340" }, { "date": "2022-03-04T08:56:00", "db": "JVNDB", "id": "JVNDB-2021-008155" }, { "date": "2022-10-06T17:28:44.817000", "db": "NVD", "id": "CVE-2021-31340" }, { "date": "2022-05-23T00:00:00", "db": "CNNVD", "id": "CNNVD-202106-475" }, { "date": "2021-04-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202104-975" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202106-475" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0SIMATIC\u00a0 Resource depletion vulnerability in the product", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-008155" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "resource management error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202106-475" } ], "trust": 0.6 } }
cve-2024-37990
Vulnerability from cvelistv5
7.0 (High) - CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-37990", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-10T15:12:00.893655Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-10T15:12:10.308Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC Reader RF610R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF610R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF610R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF615R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF615R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF615R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R ARIB", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R ARIB", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R ARIB", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF1140R", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF1170R", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF166C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF185C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF186C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF186CI", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF188C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF188CI", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF360R", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions \u003c V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions \u003c V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions \u003c V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions \u003c V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions \u003c V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions \u003c V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions \u003c V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions \u003c V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions \u003c V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions \u003c V2.2). The affected applications contain configuration files which can be modified. An attacker with privilege access can modify these files and enable features that are not released for this device." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 7, "baseSeverity": "HIGH", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-912", "description": "CWE-912: Hidden Functionality", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:36:33.772Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-765405.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-37990", "datePublished": "2024-09-10T09:36:33.772Z", "dateReserved": "2024-06-11T08:32:52.183Z", "dateUpdated": "2024-09-10T15:12:10.308Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-31340
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-787292.pdf | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T22:55:53.544Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-787292.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC RF166C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V1.1 and \u003c V1.3.2" } ] }, { "product": "SIMATIC RF185C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V1.1 and \u003c V1.3.2" } ] }, { "product": "SIMATIC RF186C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V1.1 and \u003c V1.3.2" } ] }, { "product": "SIMATIC RF186CI", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V1.1 and \u003c V1.3.2" } ] }, { "product": "SIMATIC RF188C", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V1.1 and \u003c V1.3.2" } ] }, { "product": "SIMATIC RF188CI", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V1.1 and \u003c V1.3.2" } ] }, { "product": "SIMATIC RF360R", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V2.0" } ] }, { "product": "SIMATIC Reader RF610R CMIIT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V3.0 \u003c V4.0" } ] }, { "product": "SIMATIC Reader RF610R ETSI", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V3.0 \u003c V4.0" } ] }, { "product": "SIMATIC Reader RF610R FCC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V3.0 \u003c V4.0" } ] }, { "product": "SIMATIC Reader RF615R CMIIT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V3.0 \u003c V4.0" } ] }, { "product": "SIMATIC Reader RF615R ETSI", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V3.0 \u003c V4.0" } ] }, { "product": "SIMATIC Reader RF615R FCC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V3.0 \u003c V4.0" } ] }, { "product": "SIMATIC Reader RF650R ARIB", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V3.0 \u003c V4.0" } ] }, { "product": "SIMATIC Reader RF650R CMIIT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V3.0 \u003c V4.0" } ] }, { "product": "SIMATIC Reader RF650R ETSI", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V3.0 \u003c V4.0" } ] }, { "product": "SIMATIC Reader RF650R FCC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V3.0 \u003c V4.0" } ] }, { "product": "SIMATIC Reader RF680R ARIB", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V3.0 \u003c V4.0" } ] }, { "product": "SIMATIC Reader RF680R CMIIT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V3.0 \u003c V4.0" } ] }, { "product": "SIMATIC Reader RF680R ETSI", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V3.0 \u003c V4.0" } ] }, { "product": "SIMATIC Reader RF680R FCC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V3.0 \u003c V4.0" } ] }, { "product": "SIMATIC Reader RF685R ARIB", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V3.0 \u003c V4.0" } ] }, { "product": "SIMATIC Reader RF685R CMIIT", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V3.0 \u003c V4.0" } ] }, { "product": "SIMATIC Reader RF685R ETSI", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V3.0 \u003c V4.0" } ] }, { "product": "SIMATIC Reader RF685R FCC", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003e V3.0 \u003c V4.0" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC RF166C (All versions \u003e V1.1 and \u003c V1.3.2), SIMATIC RF185C (All versions \u003e V1.1 and \u003c V1.3.2), SIMATIC RF186C (All versions \u003e V1.1 and \u003c V1.3.2), SIMATIC RF186CI (All versions \u003e V1.1 and \u003c V1.3.2), SIMATIC RF188C (All versions \u003e V1.1 and \u003c V1.3.2), SIMATIC RF188CI (All versions \u003e V1.1 and \u003c V1.3.2), SIMATIC RF360R (All versions \u003c V2.0), SIMATIC Reader RF610R CMIIT (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF610R ETSI (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF610R FCC (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF615R CMIIT (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF615R ETSI (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF615R FCC (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF650R ARIB (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF650R CMIIT (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF650R ETSI (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF650R FCC (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF680R ARIB (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF680R CMIIT (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF680R ETSI (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF680R FCC (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF685R ARIB (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF685R CMIIT (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF685R ETSI (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF685R FCC (All versions \u003e V3.0 \u003c V4.0). Affected devices do not properly handle large numbers of incoming connections. An attacker may leverage this to cause a Denial-of-Service situation." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-05-10T09:46:26", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-787292.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2021-31340", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC RF166C", "version": { "version_data": [ { "version_value": "All versions \u003e V1.1 and \u003c V1.3.2" } ] } }, { "product_name": "SIMATIC RF185C", "version": { "version_data": [ { "version_value": "All versions \u003e V1.1 and \u003c V1.3.2" } ] } }, { "product_name": "SIMATIC RF186C", "version": { "version_data": [ { "version_value": "All versions \u003e V1.1 and \u003c V1.3.2" } ] } }, { "product_name": "SIMATIC RF186CI", "version": { "version_data": [ { "version_value": "All versions \u003e V1.1 and \u003c V1.3.2" } ] } }, { "product_name": "SIMATIC RF188C", "version": { "version_data": [ { "version_value": "All versions \u003e V1.1 and \u003c V1.3.2" } ] } }, { "product_name": "SIMATIC RF188CI", "version": { "version_data": [ { "version_value": "All versions \u003e V1.1 and \u003c V1.3.2" } ] } }, { "product_name": "SIMATIC RF360R", "version": { "version_data": [ { "version_value": "All versions \u003c V2.0" } ] } }, { "product_name": "SIMATIC Reader RF610R CMIIT", "version": { "version_data": [ { "version_value": "All versions \u003e V3.0 \u003c V4.0" } ] } }, { "product_name": "SIMATIC Reader RF610R ETSI", "version": { "version_data": [ { "version_value": "All versions \u003e V3.0 \u003c V4.0" } ] } }, { "product_name": "SIMATIC Reader RF610R FCC", "version": { "version_data": [ { "version_value": "All versions \u003e V3.0 \u003c V4.0" } ] } }, { "product_name": "SIMATIC Reader RF615R CMIIT", "version": { "version_data": [ { "version_value": "All versions \u003e V3.0 \u003c V4.0" } ] } }, { "product_name": "SIMATIC Reader RF615R ETSI", "version": { "version_data": [ { "version_value": "All versions \u003e V3.0 \u003c V4.0" } ] } }, { "product_name": "SIMATIC Reader RF615R FCC", "version": { "version_data": [ { "version_value": "All versions \u003e V3.0 \u003c V4.0" } ] } }, { "product_name": "SIMATIC Reader RF650R ARIB", "version": { "version_data": [ { "version_value": "All versions \u003e V3.0 \u003c V4.0" } ] } }, { "product_name": "SIMATIC Reader RF650R CMIIT", "version": { "version_data": [ { "version_value": "All versions \u003e V3.0 \u003c V4.0" } ] } }, { "product_name": "SIMATIC Reader RF650R ETSI", "version": { "version_data": [ { "version_value": "All versions \u003e V3.0 \u003c V4.0" } ] } }, { "product_name": "SIMATIC Reader RF650R FCC", "version": { "version_data": [ { "version_value": "All versions \u003e V3.0 \u003c V4.0" } ] } }, { "product_name": "SIMATIC Reader RF680R ARIB", "version": { "version_data": [ { "version_value": "All versions \u003e V3.0 \u003c V4.0" } ] } }, { "product_name": "SIMATIC Reader RF680R CMIIT", "version": { "version_data": [ { "version_value": "All versions \u003e V3.0 \u003c V4.0" } ] } }, { "product_name": "SIMATIC Reader RF680R ETSI", "version": { "version_data": [ { "version_value": "All versions \u003e V3.0 \u003c V4.0" } ] } }, { "product_name": "SIMATIC Reader RF680R FCC", "version": { "version_data": [ { "version_value": "All versions \u003e V3.0 \u003c V4.0" } ] } }, { "product_name": "SIMATIC Reader RF685R ARIB", "version": { "version_data": [ { "version_value": "All versions \u003e V3.0 \u003c V4.0" } ] } }, { "product_name": "SIMATIC Reader RF685R CMIIT", "version": { "version_data": [ { "version_value": "All versions \u003e V3.0 \u003c V4.0" } ] } }, { "product_name": "SIMATIC Reader RF685R ETSI", "version": { "version_data": [ { "version_value": "All versions \u003e V3.0 \u003c V4.0" } ] } }, { "product_name": "SIMATIC Reader RF685R FCC", "version": { "version_data": [ { "version_value": "All versions \u003e V3.0 \u003c V4.0" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC RF166C (All versions \u003e V1.1 and \u003c V1.3.2), SIMATIC RF185C (All versions \u003e V1.1 and \u003c V1.3.2), SIMATIC RF186C (All versions \u003e V1.1 and \u003c V1.3.2), SIMATIC RF186CI (All versions \u003e V1.1 and \u003c V1.3.2), SIMATIC RF188C (All versions \u003e V1.1 and \u003c V1.3.2), SIMATIC RF188CI (All versions \u003e V1.1 and \u003c V1.3.2), SIMATIC RF360R (All versions \u003c V2.0), SIMATIC Reader RF610R CMIIT (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF610R ETSI (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF610R FCC (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF615R CMIIT (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF615R ETSI (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF615R FCC (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF650R ARIB (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF650R CMIIT (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF650R ETSI (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF650R FCC (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF680R ARIB (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF680R CMIIT (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF680R ETSI (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF680R FCC (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF685R ARIB (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF685R CMIIT (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF685R ETSI (All versions \u003e V3.0 \u003c V4.0), SIMATIC Reader RF685R FCC (All versions \u003e V3.0 \u003c V4.0). Affected devices do not properly handle large numbers of incoming connections. An attacker may leverage this to cause a Denial-of-Service situation." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400: Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-787292.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-787292.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2021-31340", "datePublished": "2021-06-08T19:47:16", "dateReserved": "2021-04-15T00:00:00", "dateUpdated": "2024-08-03T22:55:53.544Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-37994
Vulnerability from cvelistv5
5.3 (Medium) - CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-37994", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-10T15:03:36.814417Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-10T15:03:52.417Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC Reader RF610R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF610R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF610R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF615R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF615R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF615R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R ARIB", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R ARIB", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R ARIB", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF1140R", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF1170R", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF166C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF185C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF186C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF186CI", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF188C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF188CI", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF360R", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions \u003c V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions \u003c V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions \u003c V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions \u003c V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions \u003c V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions \u003c V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions \u003c V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions \u003c V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions \u003c V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions \u003c V2.2). The affected application contains a hidden configuration item to enable debug functionality. This could allow an attacker to gain insight into the internal configuration of the deployment." } ], "metrics": [ { "cvssV3_1": { "baseScore": 4.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-912", "description": "CWE-912: Hidden Functionality", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:36:40.841Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-765405.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-37994", "datePublished": "2024-09-10T09:36:40.841Z", "dateReserved": "2024-06-11T08:32:52.184Z", "dateUpdated": "2024-09-10T15:03:52.417Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-37991
Vulnerability from cvelistv5
6.0 (Medium) - CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-37991", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-10T15:09:26.404268Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-10T15:09:35.340Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC Reader RF610R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF610R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF610R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF615R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF615R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF615R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R ARIB", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R ARIB", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R ARIB", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF1140R", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF1170R", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF166C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF185C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF186C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF186CI", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF188C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF188CI", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF360R", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions \u003c V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions \u003c V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions \u003c V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions \u003c V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions \u003c V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions \u003c V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions \u003c V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions \u003c V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions \u003c V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions \u003c V2.2). The service log files of the affected application can be accessed without proper authentication. This could allow an unauthenticated attacker to get access to sensitive information." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 6, "baseSeverity": "MEDIUM", "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:P/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-200", "description": "CWE-200: Exposure of Sensitive Information to an Unauthorized Actor", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:36:35.565Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-765405.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-37991", "datePublished": "2024-09-10T09:36:35.565Z", "dateReserved": "2024-06-11T08:32:52.183Z", "dateUpdated": "2024-09-10T15:09:35.340Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-37995
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-37995", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-10T15:08:52.987640Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-10T15:09:02.700Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC Reader RF610R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF610R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF610R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF615R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF615R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF615R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R ARIB", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R ARIB", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R ARIB", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF1140R", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF1170R", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF166C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF185C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF186C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF186CI", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF188C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF188CI", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF360R", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions \u003c V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions \u003c V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions \u003c V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions \u003c V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions \u003c V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions \u003c V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions \u003c V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions \u003c V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions \u003c V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions \u003c V2.2). The affected application improperly handles error while a faulty certificate upload leading to crashing of application. This vulnerability could allow an attacker to disclose sensitive information." } ], "metrics": [ { "cvssV3_1": { "baseScore": 2.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 2.1, "baseSeverity": "LOW", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-703", "description": "CWE-703: Improper Check or Handling of Exceptional Conditions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:36:42.714Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-765405.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-37995", "datePublished": "2024-09-10T09:36:42.714Z", "dateReserved": "2024-06-11T08:32:52.184Z", "dateUpdated": "2024-09-10T15:09:02.700Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-37992
Vulnerability from cvelistv5
5.9 (Medium) - CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-37992", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-10T15:04:53.594332Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-10T15:08:09.459Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC Reader RF610R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF610R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF610R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF615R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF615R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF615R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R ARIB", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R ARIB", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R ARIB", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF1140R", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF1170R", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF166C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF185C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF186C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF186CI", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF188C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF188CI", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF360R", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions \u003c V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions \u003c V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions \u003c V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions \u003c V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions \u003c V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions \u003c V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions \u003c V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions \u003c V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions \u003c V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions \u003c V2.2). The affected devices does not properly handle the error in case of exceeding characters while setting SNMP leading to the restart of the application." } ], "metrics": [ { "cvssV3_1": { "baseScore": 4.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 5.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-703", "description": "CWE-703: Improper Check or Handling of Exceptional Conditions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:36:37.300Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-765405.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-37992", "datePublished": "2024-09-10T09:36:37.300Z", "dateReserved": "2024-06-11T08:32:52.183Z", "dateUpdated": "2024-09-10T15:08:09.459Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-37993
Vulnerability from cvelistv5
6.9 (Medium) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-37993", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-09-10T15:04:12.477171Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-09-10T15:04:32.084Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "SIMATIC Reader RF610R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF610R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF610R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF615R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF615R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF615R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R ARIB", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF650R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R ARIB", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF680R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R ARIB", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R CMIIT", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R ETSI", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC Reader RF685R FCC", "vendor": "Siemens", "versions": [ { "lessThan": "V4.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF1140R", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF1170R", "vendor": "Siemens", "versions": [ { "lessThan": "V1.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF166C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF185C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF186C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF186CI", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF188C", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF188CI", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unknown", "product": "SIMATIC RF360R", "vendor": "Siemens", "versions": [ { "lessThan": "V2.2", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions \u003c V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions \u003c V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions \u003c V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions \u003c V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions \u003c V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions \u003c V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions \u003c V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions \u003c V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions \u003c V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions \u003c V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions \u003c V2.2). The affected applications do not authenticated the creation of Ajax2App instances. This could allow an unauthenticated attacker to cause a denial of service condition." } ], "metrics": [ { "cvssV3_1": { "baseScore": 5.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } }, { "cvssV4_0": { "baseScore": 6.9, "baseSeverity": "MEDIUM", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N", "version": "4.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-284", "description": "CWE-284: Improper Access Control", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T09:36:39.074Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-765405.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-37993", "datePublished": "2024-09-10T09:36:39.074Z", "dateReserved": "2024-06-11T08:32:52.184Z", "dateUpdated": "2024-09-10T15:04:32.084Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }