CVE-2024-37993 (GCVE-0-2024-37993)
Vulnerability from cvelistv5
Published
2024-09-10 09:36
Modified
2024-09-10 15:04
Severity ?
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
6.9 (Medium) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N
6.9 (Medium) - CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The affected applications do not authenticated the creation of Ajax2App instances. This could allow an unauthenticated attacker to cause a denial of service condition.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-765405.html | Vendor Advisory |
Impacted products
{ containers: { adp: [ { metrics: [ { other: { content: { id: "CVE-2024-37993", options: [ { Exploitation: "none", }, { Automatable: "no", }, { "Technical Impact": "partial", }, ], role: "CISA Coordinator", timestamp: "2024-09-10T15:04:12.477171Z", version: "2.0.3", }, type: "ssvc", }, }, ], providerMetadata: { dateUpdated: "2024-09-10T15:04:32.084Z", orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0", shortName: "CISA-ADP", }, title: "CISA ADP Vulnrichment", }, ], cna: { affected: [ { defaultStatus: "unknown", product: "SIMATIC Reader RF610R CMIIT", vendor: "Siemens", versions: [ { lessThan: "V4.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Reader RF610R ETSI", vendor: "Siemens", versions: [ { lessThan: "V4.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Reader RF610R FCC", vendor: "Siemens", versions: [ { lessThan: "V4.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Reader RF615R CMIIT", vendor: "Siemens", versions: [ { lessThan: "V4.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Reader RF615R ETSI", vendor: "Siemens", versions: [ { lessThan: "V4.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Reader RF615R FCC", vendor: "Siemens", versions: [ { lessThan: "V4.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Reader RF650R ARIB", vendor: "Siemens", versions: [ { lessThan: "V4.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Reader RF650R CMIIT", vendor: "Siemens", versions: [ { lessThan: "V4.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Reader RF650R ETSI", vendor: "Siemens", versions: [ { lessThan: "V4.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Reader RF650R FCC", vendor: "Siemens", versions: [ { lessThan: "V4.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Reader RF680R ARIB", vendor: "Siemens", versions: [ { lessThan: "V4.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Reader RF680R CMIIT", vendor: "Siemens", versions: [ { lessThan: "V4.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Reader RF680R ETSI", vendor: "Siemens", versions: [ { lessThan: "V4.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Reader RF680R FCC", vendor: "Siemens", versions: [ { lessThan: "V4.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Reader RF685R ARIB", vendor: "Siemens", versions: [ { lessThan: "V4.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Reader RF685R CMIIT", vendor: "Siemens", versions: [ { lessThan: "V4.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Reader RF685R ETSI", vendor: "Siemens", versions: [ { lessThan: "V4.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC Reader RF685R FCC", vendor: "Siemens", versions: [ { lessThan: "V4.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF1140R", vendor: "Siemens", versions: [ { lessThan: "V1.1", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF1170R", vendor: "Siemens", versions: [ { lessThan: "V1.1", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF166C", vendor: "Siemens", versions: [ { lessThan: "V2.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF185C", vendor: "Siemens", versions: [ { lessThan: "V2.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF186C", vendor: "Siemens", versions: [ { lessThan: "V2.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF186CI", vendor: "Siemens", versions: [ { lessThan: "V2.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF188C", vendor: "Siemens", versions: [ { lessThan: "V2.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF188CI", vendor: "Siemens", versions: [ { lessThan: "V2.2", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "SIMATIC RF360R", vendor: "Siemens", versions: [ { lessThan: "V2.2", status: "affected", version: "0", versionType: "custom", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The affected applications do not authenticated the creation of Ajax2App instances. This could allow an unauthenticated attacker to cause a denial of service condition.", }, ], metrics: [ { cvssV3_1: { baseScore: 5.3, baseSeverity: "MEDIUM", vectorString: "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", version: "3.1", }, }, { cvssV4_0: { baseScore: 6.9, baseSeverity: "MEDIUM", vectorString: "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N", version: "4.0", }, }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-284", description: "CWE-284: Improper Access Control", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2024-09-10T09:36:39.074Z", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { url: "https://cert-portal.siemens.com/productcert/html/ssa-765405.html", }, ], }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2024-37993", datePublished: "2024-09-10T09:36:39.074Z", dateReserved: "2024-06-11T08:32:52.184Z", dateUpdated: "2024-09-10T15:04:32.084Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", "vulnerability-lookup:meta": { fkie_nvd: { configurations: "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_rf360r_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.2\", \"matchCriteriaId\": \"D8930F2B-7C37-4059-85FC-0316B631C860\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_rf360r:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"63F05227-208B-42C8-8D56-A5D106CAD32F\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_rf1170r_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.1\", \"matchCriteriaId\": \"CC216594-D56B-454D-BD2C-50631B8C8F9C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_rf1170r:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DD8AD128-F6E2-45BD-9098-EC559D193194\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_rf1140r_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.1\", \"matchCriteriaId\": \"11F4F714-F802-4D13-A965-0A22B80DA9D0\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_rf1140r:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1EA20BB5-024E-4389-A0FE-C218E15D31A8\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_reader_rf685r_fcc_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.2\", \"matchCriteriaId\": \"F61801B9-80FD-45EC-9A20-5C703CB8BE76\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_reader_rf685r_fcc:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"76F5073F-CAE9-4071-9C86-2B29FB529A49\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_reader_rf685r_etsi_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.2\", \"matchCriteriaId\": \"058EDB3A-31B8-482F-B825-B0A7E192356E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_reader_rf685r_etsi:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D00C8A81-53EB-425F-A730-AC7505285B73\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_reader_rf685r_cmiit_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.2\", \"matchCriteriaId\": \"62FC4D21-B225-4349-A8E8-68780CC465D1\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_reader_rf685r_cmiit:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B3C8FC67-825D-4E55-8341-E449EA98B6AD\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_reader_rf685r_arib_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.2\", \"matchCriteriaId\": \"1E84B475-1FB7-4BF1-880B-8DB5137BB941\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_reader_rf685r_arib:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"BFAA7370-1B78-4AF8-8358-830460A5E81C\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_reader_rf680r_fcc_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.2\", \"matchCriteriaId\": \"970B3705-6172-4C00-B402-30A7F23C5A08\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_reader_rf680r_fcc:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"40D5F6C3-3AC5-40F2-B755-130E24169AB3\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_reader_rf680r_etsi_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.2\", \"matchCriteriaId\": \"7D261FBC-1E4C-4016-AD0E-F234EE36F09A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_reader_rf680r_etsi:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"08729226-19DB-410A-A764-B84E5213839D\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_reader_rf680r_cmiit_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.2\", \"matchCriteriaId\": \"B5B465BD-D425-44C7-931C-E6DAABB79B67\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_reader_rf680r_cmiit:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"EA13A689-EBB3-47D3-83AB-4EAFCB0CCF14\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_reader_rf680r_arib_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.2\", \"matchCriteriaId\": \"C1B9A6C1-E7AD-46DE-A0EC-E6E03B957A13\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_reader_rf680r_arib:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CC372090-E9D1-4CB7-8CDC-8FA439764359\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_reader_rf650r_fcc_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.2\", \"matchCriteriaId\": \"6BBDF6C6-A67A-412F-8ACF-27E3AA0EE8E9\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_reader_rf650r_fcc:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"EFD9ED6C-B948-4F73-ADC9-2EA7AFB646C9\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_reader_rf650r_etsi_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.2\", \"matchCriteriaId\": \"28C49CB8-179A-47B7-9B04-FC214382B643\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_reader_rf650r_etsi:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"70C73C18-EC1D-431A-808F-1C16706B7F26\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_reader_rf650r_cmiit_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.2\", \"matchCriteriaId\": \"896E8488-0AB0-4C39-9729-1E42F4C28419\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_reader_rf650r_cmiit:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"838474F2-85A2-4315-8F0C-B1AAC9B20373\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_reader_rf650r_arib_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.2\", \"matchCriteriaId\": \"E525612D-8273-42FD-8DAD-D589ED61C9D6\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_reader_rf650r_arib:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5735D69B-EBA4-4ADD-9D02-AFFBDB14B085\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_reader_rf615r_fcc_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.2\", \"matchCriteriaId\": \"130361E8-6979-492F-89A3-4EFFF8F5379F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_reader_rf615r_fcc:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"557BB258-1B9D-457F-9573-85439950C361\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_reader_rf615r_etsi_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.2\", \"matchCriteriaId\": \"DC98A393-C374-4411-94FE-9832CD8690ED\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_reader_rf615r_etsi:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C951AC92-DD7E-4C24-BC38-1D041D81691C\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_reader_rf615r_cmiit_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.2\", \"matchCriteriaId\": \"2AA399AA-B0C4-48D5-B5F5-EE7A65D10A95\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_reader_rf615r_cmiit:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C4C96D63-0711-48F8-ADE2-261FCF306049\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_reader_rf610r_fcc_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.2\", \"matchCriteriaId\": \"C902FA6A-3E5D-471C-8513-27FE8BB5B2DC\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_reader_rf610r_fcc:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F85BC978-9C30-4484-B6D7-B7A4543EFDA5\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_reader_rf610r_etsi_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.2\", \"matchCriteriaId\": \"FA5DA457-347E-4B6B-8003-882BD4D95D64\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_reader_rf610r_etsi:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E0BFFE2B-5843-4A03-A6A7-1098A4FB9A0C\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_reader_rf610r_cmiit_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.2\", \"matchCriteriaId\": \"B07B2FDF-E6A5-4E06-9328-01F311E85AF9\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_reader_rf610r_cmiit:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C3CE2417-B29E-4CBD-9A30-3DB5C30771D5\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_rf188ci_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.2\", \"matchCriteriaId\": \"84F1472B-A584-4712-BEF7-7B4BDE166CE2\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_rf188ci:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B0927991-E820-4FC3-9EFE-96E4C9BFCCCD\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.2\", \"matchCriteriaId\": \"D7DB4915-E989-4085-B201-C5CCC86AB924\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E21F9909-8D80-40BE-81E0-6ED7FE140A3A\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_rf186ci_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.2\", \"matchCriteriaId\": \"B280EE0D-F3F9-46E3-949F-109844428C35\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_rf186ci:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1EAEB335-BD22-4CEF-A3EA-9D98A09FEBF0\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.2\", \"matchCriteriaId\": \"E86AC831-9FB9-4D17-AA06-E68C176F1A23\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_rf186c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9B0933EB-82BE-42BB-978B-C9EC2FE1C795\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.2\", \"matchCriteriaId\": \"1A27B28F-A037-4730-A0DD-96BB568F4A58\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_rf185c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"82494B5E-80EE-47ED-B87E-CF8C8907B6FE\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_rf166c_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.2\", \"matchCriteriaId\": \"D48EE1B0-3010-44F2-AEF9-A3E35BD03971\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_rf166c:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"391AD485-A49D-43D0-AAE5-1F58B38D4E22\"}]}]}]", descriptions: "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The affected applications do not authenticated the creation of Ajax2App instances. This could allow an unauthenticated attacker to cause a denial of service condition.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (Todas las versiones < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (Todas las versiones < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (Todas las versiones < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (Todas las versiones < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (Todas las versiones < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (Todas las versiones < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (Todas las versiones < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (Todas las versiones < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (Todas las versiones < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (Todas las versiones < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (Todas las versiones < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (Todas las versiones < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (Todas las versiones < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (Todas las versiones < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (Todas las versiones < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (Todas las versiones < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (Todas las versiones < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (Todas las versiones < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (Todas las versiones < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (Todas las versiones < V1.1), SIMATIC RF166C (6GT2002-0EE20) (Todas las versiones < V2.2), SIMATIC RF185C (6GT2002-0JE10) (Todas las versiones < V2.2), SIMATIC RF186C (6GT2002-0JE20) (Todas las versiones < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (Todas las versiones < V2.2), SIMATIC RF188C (6GT2002-0JE40) (Todas las versiones < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (Todas las versiones < V2.2), SIMATIC RF360R (6GT2801-5BA30) (Todas las versiones < V2.2). Las aplicaciones afectadas no autentican la creaci\\u00f3n de instancias de Ajax2App. Esto podr\\u00eda permitir que un atacante no autenticado provoque una condici\\u00f3n de denegaci\\u00f3n de servicio.\"}]", id: "CVE-2024-37993", lastModified: "2024-09-18T15:32:26.037", metrics: "{\"cvssMetricV40\": [{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"4.0\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\", \"baseScore\": 6.9, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"vulnerableSystemConfidentiality\": \"NONE\", \"vulnerableSystemIntegrity\": \"NONE\", \"vulnerableSystemAvailability\": \"LOW\", \"subsequentSystemConfidentiality\": \"NONE\", \"subsequentSystemIntegrity\": \"NONE\", \"subsequentSystemAvailability\": \"NONE\", \"exploitMaturity\": \"NOT_DEFINED\", \"confidentialityRequirements\": \"NOT_DEFINED\", \"integrityRequirements\": \"NOT_DEFINED\", \"availabilityRequirements\": \"NOT_DEFINED\", \"modifiedAttackVector\": \"NOT_DEFINED\", \"modifiedAttackComplexity\": \"NOT_DEFINED\", \"modifiedAttackRequirements\": \"NOT_DEFINED\", \"modifiedPrivilegesRequired\": \"NOT_DEFINED\", \"modifiedUserInteraction\": \"NOT_DEFINED\", \"modifiedVulnerableSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedVulnerableSystemIntegrity\": \"NOT_DEFINED\", \"modifiedVulnerableSystemAvailability\": \"NOT_DEFINED\", \"modifiedSubsequentSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedSubsequentSystemIntegrity\": \"NOT_DEFINED\", \"modifiedSubsequentSystemAvailability\": \"NOT_DEFINED\", \"safety\": \"NOT_DEFINED\", \"automatable\": \"NOT_DEFINED\", \"recovery\": \"NOT_DEFINED\", \"valueDensity\": \"NOT_DEFINED\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\"}}], \"cvssMetricV31\": [{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 1.4}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}", published: "2024-09-10T10:15:11.090", references: "[{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-765405.html\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Vendor Advisory\"]}]", sourceIdentifier: "productcert@siemens.com", vulnStatus: "Analyzed", weaknesses: "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-284\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]", }, nvd: "{\"cve\":{\"id\":\"CVE-2024-37993\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-09-10T10:15:11.090\",\"lastModified\":\"2024-09-18T15:32:26.037\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The affected applications do not authenticated the creation of Ajax2App instances. This could allow an unauthenticated attacker to cause a denial of service condition.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (Todas las versiones < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (Todas las versiones < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (Todas las versiones < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (Todas las versiones < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (Todas las versiones < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (Todas las versiones < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (Todas las versiones < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (Todas las versiones < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (Todas las versiones < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (Todas las versiones < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (Todas las versiones < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (Todas las versiones < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (Todas las versiones < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (Todas las versiones < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (Todas las versiones < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (Todas las versiones < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (Todas las versiones < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (Todas las versiones < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (Todas las versiones < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (Todas las versiones < V1.1), SIMATIC RF166C (6GT2002-0EE20) (Todas las versiones < V2.2), SIMATIC RF185C (6GT2002-0JE10) (Todas las versiones < V2.2), SIMATIC RF186C (6GT2002-0JE20) (Todas las versiones < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (Todas las versiones < V2.2), SIMATIC RF188C (6GT2002-0JE40) (Todas las versiones < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (Todas las versiones < V2.2), SIMATIC RF360R (6GT2801-5BA30) (Todas las versiones < V2.2). Las aplicaciones afectadas no autentican la creación de instancias de Ajax2App. Esto podría permitir que un atacante no autenticado provoque una condición de denegación de servicio.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":6.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnerableSystemConfidentiality\":\"NONE\",\"vulnerableSystemIntegrity\":\"NONE\",\"vulnerableSystemAvailability\":\"LOW\",\"subsequentSystemConfidentiality\":\"NONE\",\"subsequentSystemIntegrity\":\"NONE\",\"subsequentSystemAvailability\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirements\":\"NOT_DEFINED\",\"integrityRequirements\":\"NOT_DEFINED\",\"availabilityRequirements\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnerableSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedVulnerableSystemIntegrity\":\"NOT_DEFINED\",\"modifiedVulnerableSystemAvailability\":\"NOT_DEFINED\",\"modifiedSubsequentSystemConfidentiality\":\"NOT_DEFINED\",\"modifiedSubsequentSystemIntegrity\":\"NOT_DEFINED\",\"modifiedSubsequentSystemAvailability\":\"NOT_DEFINED\",\"safety\":\"NOT_DEFINED\",\"automatable\":\"NOT_DEFINED\",\"recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-284\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_rf360r_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.2\",\"matchCriteriaId\":\"D8930F2B-7C37-4059-85FC-0316B631C860\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_rf360r:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"63F05227-208B-42C8-8D56-A5D106CAD32F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_rf1170r_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.1\",\"matchCriteriaId\":\"CC216594-D56B-454D-BD2C-50631B8C8F9C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_rf1170r:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DD8AD128-F6E2-45BD-9098-EC559D193194\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_rf1140r_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.1\",\"matchCriteriaId\":\"11F4F714-F802-4D13-A965-0A22B80DA9D0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_rf1140r:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1EA20BB5-024E-4389-A0FE-C218E15D31A8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_reader_rf685r_fcc_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.2\",\"matchCriteriaId\":\"F61801B9-80FD-45EC-9A20-5C703CB8BE76\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_reader_rf685r_fcc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"76F5073F-CAE9-4071-9C86-2B29FB529A49\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_reader_rf685r_etsi_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.2\",\"matchCriteriaId\":\"058EDB3A-31B8-482F-B825-B0A7E192356E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_reader_rf685r_etsi:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D00C8A81-53EB-425F-A730-AC7505285B73\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_reader_rf685r_cmiit_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.2\",\"matchCriteriaId\":\"62FC4D21-B225-4349-A8E8-68780CC465D1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_reader_rf685r_cmiit:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B3C8FC67-825D-4E55-8341-E449EA98B6AD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_reader_rf685r_arib_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.2\",\"matchCriteriaId\":\"1E84B475-1FB7-4BF1-880B-8DB5137BB941\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_reader_rf685r_arib:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BFAA7370-1B78-4AF8-8358-830460A5E81C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_reader_rf680r_fcc_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.2\",\"matchCriteriaId\":\"970B3705-6172-4C00-B402-30A7F23C5A08\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_reader_rf680r_fcc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"40D5F6C3-3AC5-40F2-B755-130E24169AB3\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_reader_rf680r_etsi_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.2\",\"matchCriteriaId\":\"7D261FBC-1E4C-4016-AD0E-F234EE36F09A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_reader_rf680r_etsi:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"08729226-19DB-410A-A764-B84E5213839D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_reader_rf680r_cmiit_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.2\",\"matchCriteriaId\":\"B5B465BD-D425-44C7-931C-E6DAABB79B67\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_reader_rf680r_cmiit:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EA13A689-EBB3-47D3-83AB-4EAFCB0CCF14\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_reader_rf680r_arib_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.2\",\"matchCriteriaId\":\"C1B9A6C1-E7AD-46DE-A0EC-E6E03B957A13\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_reader_rf680r_arib:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CC372090-E9D1-4CB7-8CDC-8FA439764359\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_reader_rf650r_fcc_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.2\",\"matchCriteriaId\":\"6BBDF6C6-A67A-412F-8ACF-27E3AA0EE8E9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_reader_rf650r_fcc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EFD9ED6C-B948-4F73-ADC9-2EA7AFB646C9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_reader_rf650r_etsi_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.2\",\"matchCriteriaId\":\"28C49CB8-179A-47B7-9B04-FC214382B643\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_reader_rf650r_etsi:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"70C73C18-EC1D-431A-808F-1C16706B7F26\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_reader_rf650r_cmiit_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.2\",\"matchCriteriaId\":\"896E8488-0AB0-4C39-9729-1E42F4C28419\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_reader_rf650r_cmiit:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"838474F2-85A2-4315-8F0C-B1AAC9B20373\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_reader_rf650r_arib_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.2\",\"matchCriteriaId\":\"E525612D-8273-42FD-8DAD-D589ED61C9D6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_reader_rf650r_arib:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5735D69B-EBA4-4ADD-9D02-AFFBDB14B085\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_reader_rf615r_fcc_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.2\",\"matchCriteriaId\":\"130361E8-6979-492F-89A3-4EFFF8F5379F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_reader_rf615r_fcc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"557BB258-1B9D-457F-9573-85439950C361\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_reader_rf615r_etsi_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.2\",\"matchCriteriaId\":\"DC98A393-C374-4411-94FE-9832CD8690ED\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_reader_rf615r_etsi:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C951AC92-DD7E-4C24-BC38-1D041D81691C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_reader_rf615r_cmiit_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.2\",\"matchCriteriaId\":\"2AA399AA-B0C4-48D5-B5F5-EE7A65D10A95\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_reader_rf615r_cmiit:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C4C96D63-0711-48F8-ADE2-261FCF306049\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_reader_rf610r_fcc_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.2\",\"matchCriteriaId\":\"C902FA6A-3E5D-471C-8513-27FE8BB5B2DC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_reader_rf610r_fcc:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F85BC978-9C30-4484-B6D7-B7A4543EFDA5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_reader_rf610r_etsi_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.2\",\"matchCriteriaId\":\"FA5DA457-347E-4B6B-8003-882BD4D95D64\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_reader_rf610r_etsi:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E0BFFE2B-5843-4A03-A6A7-1098A4FB9A0C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_reader_rf610r_cmiit_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.2\",\"matchCriteriaId\":\"B07B2FDF-E6A5-4E06-9328-01F311E85AF9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_reader_rf610r_cmiit:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C3CE2417-B29E-4CBD-9A30-3DB5C30771D5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_rf188ci_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.2\",\"matchCriteriaId\":\"84F1472B-A584-4712-BEF7-7B4BDE166CE2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_rf188ci:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B0927991-E820-4FC3-9EFE-96E4C9BFCCCD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_rf188c_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.2\",\"matchCriteriaId\":\"D7DB4915-E989-4085-B201-C5CCC86AB924\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_rf188c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E21F9909-8D80-40BE-81E0-6ED7FE140A3A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_rf186ci_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.2\",\"matchCriteriaId\":\"B280EE0D-F3F9-46E3-949F-109844428C35\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_rf186ci:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1EAEB335-BD22-4CEF-A3EA-9D98A09FEBF0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_rf186c_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.2\",\"matchCriteriaId\":\"E86AC831-9FB9-4D17-AA06-E68C176F1A23\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_rf186c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9B0933EB-82BE-42BB-978B-C9EC2FE1C795\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_rf185c_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.2\",\"matchCriteriaId\":\"1A27B28F-A037-4730-A0DD-96BB568F4A58\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_rf185c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"82494B5E-80EE-47ED-B87E-CF8C8907B6FE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_rf166c_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.2\",\"matchCriteriaId\":\"D48EE1B0-3010-44F2-AEF9-A3E35BD03971\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_rf166c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"391AD485-A49D-43D0-AAE5-1F58B38D4E22\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-765405.html\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}", vulnrichment: { containers: "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-37993\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-09-10T15:04:12.477171Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-09-10T15:04:26.382Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\"}}, {\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 6.9, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"SIMATIC Reader RF610R CMIIT\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Reader RF610R ETSI\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Reader RF610R FCC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Reader RF615R CMIIT\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Reader RF615R ETSI\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Reader RF615R FCC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Reader RF650R ARIB\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Reader RF650R CMIIT\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Reader RF650R ETSI\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Reader RF650R FCC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Reader RF680R ARIB\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Reader RF680R CMIIT\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Reader RF680R ETSI\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Reader RF680R FCC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Reader RF685R ARIB\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Reader RF685R CMIIT\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Reader RF685R ETSI\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC Reader RF685R FCC\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V4.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC RF1140R\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC RF1170R\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V1.1\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC RF166C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC RF185C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC RF186C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC RF186CI\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC RF188C\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC RF188CI\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"SIMATIC RF360R\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2.2\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-765405.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The affected applications do not authenticated the creation of Ajax2App instances. This could allow an unauthenticated attacker to cause a denial of service condition.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-284\", \"description\": \"CWE-284: Improper Access Control\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2024-09-10T09:36:39.074Z\"}}}", cveMetadata: "{\"cveId\": \"CVE-2024-37993\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-09-10T15:04:32.084Z\", \"dateReserved\": \"2024-06-11T08:32:52.184Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2024-09-10T09:36:39.074Z\", \"assignerShortName\": \"siemens\"}", dataType: "CVE_RECORD", dataVersion: "5.1", }, }, }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.