All the vulnerabilites related to Siemens - SINETPLAN
cve-2019-10915
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf | x_refsource_MISC | |
http://www.securityfocus.com/bid/109124 | vdb-entry, x_refsource_BID | |
https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf | x_refsource_CONFIRM | |
https://www.us-cert.gov/ics/advisories/icsa-19-253-02 | x_refsource_MISC |
▼ | Vendor | Product |
---|---|---|
Siemens AG | TIA Administrator |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T22:40:15.369Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf" }, { "name": "109124", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/109124" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "TIA Administrator", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions \u003c V1.0 SP1 Upd1" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306: Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2019-09-24T15:35:14", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf" }, { "name": "109124", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/109124" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-10915", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "TIA Administrator", "version": { "version_data": [ { "version_value": "All versions \u003c V1.0 SP1 Upd1" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in TIA Administrator (All versions \u003c V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-306: Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf" }, { "name": "109124", "refsource": "BID", "url": "http://www.securityfocus.com/bid/109124" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf" }, { "name": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02", "refsource": "MISC", "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-10915", "datePublished": "2019-07-11T21:17:46", "dateReserved": "2019-04-08T00:00:00", "dateUpdated": "2024-08-04T22:40:15.369Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-27194
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://cert-portal.siemens.com/productcert/pdf/ssa-711829.pdf | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T05:25:31.062Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-711829.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC PCS neo (Administration Console)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V3.1 SP1" } ] }, { "product": "SINETPLAN", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "TIA Portal", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "V15, V15.1, V16 and V17" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC PCS neo (Administration Console) (All versions \u003c V3.1 SP1), SINETPLAN (All versions), TIA Portal (V15, V15.1, V16 and V17). The affected system cannot properly process specially crafted packets sent to port 8888/tcp. A remote attacker could exploit this vulnerability to cause a Denial-of-Service condition. The affected devices must be restarted manually." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-400", "description": "CWE-400: Uncontrolled Resource Consumption", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-04-12T09:07:58", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-711829.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-27194", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC PCS neo (Administration Console)", "version": { "version_data": [ { "version_value": "All versions \u003c V3.1 SP1" } ] } }, { "product_name": "SINETPLAN", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "TIA Portal", "version": { "version_data": [ { "version_value": "V15, V15.1, V16 and V17" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC PCS neo (Administration Console) (All versions \u003c V3.1 SP1), SINETPLAN (All versions), TIA Portal (V15, V15.1, V16 and V17). The affected system cannot properly process specially crafted packets sent to port 8888/tcp. A remote attacker could exploit this vulnerability to cause a Denial-of-Service condition. The affected devices must be restarted manually." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-400: Uncontrolled Resource Consumption" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-711829.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-711829.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2022-27194", "datePublished": "2022-04-12T09:07:59", "dateReserved": "2022-03-15T00:00:00", "dateUpdated": "2024-08-03T05:25:31.062Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
var-202204-0227
Vulnerability from variot
A vulnerability has been identified in SIMATIC PCS neo (Administration Console) (All versions < V3.1 SP1), SINETPLAN (All versions), TIA Portal (V15, V15.1, V16 and V17). The affected system cannot properly process specially crafted packets sent to port 8888/tcp. A remote attacker could exploit this vulnerability to cause a Denial-of-Service condition. The affected devices must be restarted manually. Siemens' SIMATIC PCS neo , sinetplan , totally integrated automation portal Exists in a resource exhaustion vulnerability.Service operation interruption (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202204-0227", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "sinetplan", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "*" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "16" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15.1" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "15" }, { "model": "totally integrated automation portal", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "17" }, { "model": "simatic pcs neo", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "3.1" }, { "model": "simatic pcs neo", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "3.1" }, { "model": "sinetplan", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "totally integrated automation portal", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "simatic pcs neo", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-008099" }, { "db": "NVD", "id": "CVE-2022-27194" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_neo:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "3.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_neo:3.1:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:sinetplan:*:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:15:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:15.1:-:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:16:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:totally_integrated_automation_portal:17:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-27194" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Peter Cheng of Elex Feigong Research reported this vulnerability to Siemens.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202204-2947" } ], "trust": 0.6 }, "cve": "CVE-2022-27194", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "impactScore": 6.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 7.8, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2022-27194", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2022-27194", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-27194", "trust": 1.8, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202204-2947", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2022-27194", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "VULMON", "id": "CVE-2022-27194" }, { "db": "JVNDB", "id": "JVNDB-2022-008099" }, { "db": "NVD", "id": "CVE-2022-27194" }, { "db": "CNNVD", "id": "CNNVD-202204-2947" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in SIMATIC PCS neo (Administration Console) (All versions \u003c V3.1 SP1), SINETPLAN (All versions), TIA Portal (V15, V15.1, V16 and V17). The affected system cannot properly process specially crafted packets sent to port 8888/tcp. A remote attacker could exploit this vulnerability to cause a Denial-of-Service condition. The affected devices must be restarted manually. Siemens\u0027 SIMATIC PCS neo , sinetplan , totally integrated automation portal Exists in a resource exhaustion vulnerability.Service operation interruption (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2022-27194" }, { "db": "JVNDB", "id": "JVNDB-2022-008099" }, { "db": "VULMON", "id": "CVE-2022-27194" } ], "trust": 1.71 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-27194", "trust": 3.3 }, { "db": "SIEMENS", "id": "SSA-711829", "trust": 2.5 }, { "db": "ICS CERT", "id": "ICSA-22-104-16", "trust": 1.5 }, { "db": "JVN", "id": "JVNVU91165555", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2022-008099", "trust": 0.8 }, { "db": "CS-HELP", "id": "SB2022042009", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202204-2947", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2022-27194", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2022-27194" }, { "db": "JVNDB", "id": "JVNDB-2022-008099" }, { "db": "NVD", "id": "CVE-2022-27194" }, { "db": "CNNVD", "id": "CNNVD-202204-2947" } ] }, "id": "VAR-202204-0227", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.6076923 }, "last_update_date": "2023-12-18T11:56:14.931000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Multiple Siemens SIMATIC product Remediation of resource management error vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=189472" } ], "sources": [ { "db": "CNNVD", "id": "CNNVD-202204-2947" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-400", "trust": 1.0 }, { "problemtype": "Resource exhaustion (CWE-400) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-008099" }, { "db": "NVD", "id": "CVE-2022-27194" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-711829.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu91165555/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-27194" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-104-16" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-104-16" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/simatic-pcs-neo-denial-of-service-via-tia-administrator-38021" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022042009" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-27194/" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/400.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-16" } ], "sources": [ { "db": "VULMON", "id": "CVE-2022-27194" }, { "db": "JVNDB", "id": "JVNDB-2022-008099" }, { "db": "NVD", "id": "CVE-2022-27194" }, { "db": "CNNVD", "id": "CNNVD-202204-2947" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2022-27194" }, { "db": "JVNDB", "id": "JVNDB-2022-008099" }, { "db": "NVD", "id": "CVE-2022-27194" }, { "db": "CNNVD", "id": "CNNVD-202204-2947" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-04-12T00:00:00", "db": "VULMON", "id": "CVE-2022-27194" }, { "date": "2023-07-24T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-008099" }, { "date": "2022-04-12T09:15:15.017000", "db": "NVD", "id": "CVE-2022-27194" }, { "date": "2022-04-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202204-2947" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-04-19T00:00:00", "db": "VULMON", "id": "CVE-2022-27194" }, { "date": "2023-07-24T08:22:00", "db": "JVNDB", "id": "JVNDB-2022-008099" }, { "date": "2022-04-19T18:28:39.223000", "db": "NVD", "id": "CVE-2022-27194" }, { "date": "2022-04-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202204-2947" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202204-2947" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Resource Exhaustion Vulnerability in Multiple Siemens Products", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-008099" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "resource management error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202204-2947" } ], "trust": 0.6 } }
var-201907-1466
Vulnerability from variot
A vulnerability has been identified in TIA Administrator (All versions < V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. TIA Administrator Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. SimaticWinCC (TIAPortal) is an engineering software for configuring and programming Simatic panels, Simatic industrial PCs and standard PCWinccruntime professional visualization software running WinCC RuntimeAdvanced or SCADA systems. An authentication vulnerability exists in SiemensTIAAdministrator. An attacker can exploit this issue to bypass the authentication mechanism or execute arbitrary commands. This may aid in further attacks
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201907-1466", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "tia administrator", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "1.0" }, { "model": "sinetplan", "scope": "eq", "trust": 1.0, "vendor": "siemens", "version": "2.0" }, { "model": "tia administrator", "scope": "lt", "trust": 0.8, "vendor": "siemens", "version": "1.0 sp1 upd1" }, { "model": "tia administrato sp1 upd1", "scope": "lt", "trust": 0.6, "vendor": "siemens", "version": "v1.0" }, { "model": "tia administrator", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "tia administrator sp1 upd1", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "1.0" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "tia administrator", "version": "1.0" } ], "sources": [ { "db": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4" }, { "db": "CNVD", "id": "CNVD-2019-22235" }, { "db": "BID", "id": "109124" }, { "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "db": "NVD", "id": "CVE-2019-10915" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:tia_administrator:1.0:sp1:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:sinetplan:2.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2019-10915" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Joseph Bingham from Tenable.", "sources": [ { "db": "BID", "id": "109124" }, { "db": "CNNVD", "id": "CNNVD-201907-692" } ], "trust": 0.9 }, "cve": "CVE-2019-10915", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 4.6, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 3.9, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Local", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 4.6, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2019-10915", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "id": "CNVD-2019-22235", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "id": "c0202593-9236-4865-9b2d-ebb56c677ca4", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.9 [IVD]" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2019-10915", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "Low", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2019-10915", "trust": 1.8, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2019-22235", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201907-692", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4", "trust": 0.2, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4" }, { "db": "CNVD", "id": "CNVD-2019-22235" }, { "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "db": "NVD", "id": "CVE-2019-10915" }, { "db": "CNNVD", "id": "CNNVD-201907-692" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in TIA Administrator (All versions \u003c V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. TIA Administrator Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. SimaticWinCC (TIAPortal) is an engineering software for configuring and programming Simatic panels, Simatic industrial PCs and standard PCWinccruntime professional visualization software running WinCC RuntimeAdvanced or SCADA systems. An authentication vulnerability exists in SiemensTIAAdministrator. \nAn attacker can exploit this issue to bypass the authentication mechanism or execute arbitrary commands. This may aid in further attacks", "sources": [ { "db": "NVD", "id": "CVE-2019-10915" }, { "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "db": "CNVD", "id": "CNVD-2019-22235" }, { "db": "BID", "id": "109124" }, { "db": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4" } ], "trust": 2.61 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-10915", "trust": 3.5 }, { "db": "SIEMENS", "id": "SSA-721298", "trust": 2.5 }, { "db": "ICS CERT", "id": "ICSA-19-253-02", "trust": 2.4 }, { "db": "BID", "id": "109124", "trust": 1.9 }, { "db": "ICS CERT", "id": "ICSA-19-192-03", "trust": 1.7 }, { "db": "SIEMENS", "id": "SSA-834884", "trust": 1.6 }, { "db": "CNVD", "id": "CNVD-2019-22235", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201907-692", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2019-007049", "trust": 0.8 }, { "db": "AUSCERT", "id": "ESB-2019.3444", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2019.2587", "trust": 0.6 }, { "db": "IVD", "id": "C0202593-9236-4865-9B2D-EBB56C677CA4", "trust": 0.2 } ], "sources": [ { "db": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4" }, { "db": "CNVD", "id": "CNVD-2019-22235" }, { "db": "BID", "id": "109124" }, { "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "db": "NVD", "id": "CVE-2019-10915" }, { "db": "CNNVD", "id": "CNNVD-201907-692" } ] }, "id": "VAR-201907-1466", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4" }, { "db": "CNVD", "id": "CNVD-2019-22235" } ], "trust": 1.8 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4" }, { "db": "CNVD", "id": "CNVD-2019-22235" } ] }, "last_update_date": "2023-12-18T13:38:14.301000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-721298", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf" }, { "title": "SSA-834884", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf" }, { "title": "Patch for SiemensTIAAdministrator authentication vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/168525" }, { "title": "Siemens TIA Administrator Fixes for access control error vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=95226" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-22235" }, { "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "db": "CNNVD", "id": "CNNVD-201907-692" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-306", "trust": 1.0 }, { "problemtype": "CWE-264", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "db": "NVD", "id": "CVE-2019-10915" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-721298.pdf" }, { "trust": 2.4, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-253-02" }, { "trust": 2.2, "url": "http://www.securityfocus.com/bid/109124" }, { "trust": 1.7, "url": "https://www.us-cert.gov/ics/advisories/icsa-19-192-03" }, { "trust": 1.6, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-834884.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-10915" }, { "trust": 0.9, "url": "https://medium.com/tenable-techblog/nuclear-meltdown-with-critical-ics-vulnerabilities-8af3a1a13e6a" }, { "trust": 0.9, "url": "http://www.siemens.com/" }, { "trust": 0.9, "url": "https://github.com/tenable/poc/tree/master/siemens/tiaportal" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-10915" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2019.3444/" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2019.2587/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2019-22235" }, { "db": "BID", "id": "109124" }, { "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "db": "NVD", "id": "CVE-2019-10915" }, { "db": "CNNVD", "id": "CNNVD-201907-692" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4" }, { "db": "CNVD", "id": "CNVD-2019-22235" }, { "db": "BID", "id": "109124" }, { "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "db": "NVD", "id": "CVE-2019-10915" }, { "db": "CNNVD", "id": "CNNVD-201907-692" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-07-12T00:00:00", "db": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4" }, { "date": "2019-07-12T00:00:00", "db": "CNVD", "id": "CNVD-2019-22235" }, { "date": "2019-07-09T00:00:00", "db": "BID", "id": "109124" }, { "date": "2019-07-31T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "date": "2019-07-11T22:15:11.047000", "db": "NVD", "id": "CVE-2019-10915" }, { "date": "2019-07-11T00:00:00", "db": "CNNVD", "id": "CNNVD-201907-692" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2019-07-12T00:00:00", "db": "CNVD", "id": "CNVD-2019-22235" }, { "date": "2019-07-09T00:00:00", "db": "BID", "id": "109124" }, { "date": "2019-10-04T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-007049" }, { "date": "2020-10-02T14:29:36.723000", "db": "NVD", "id": "CVE-2019-10915" }, { "date": "2020-10-28T00:00:00", "db": "CNNVD", "id": "CNNVD-201907-692" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "BID", "id": "109124" }, { "db": "CNNVD", "id": "CNNVD-201907-692" } ], "trust": 0.9 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens TIA Administrator Authentication vulnerability", "sources": [ { "db": "IVD", "id": "c0202593-9236-4865-9b2d-ebb56c677ca4" }, { "db": "CNVD", "id": "CNVD-2019-22235" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "access control error", "sources": [ { "db": "CNNVD", "id": "CNNVD-201907-692" } ], "trust": 0.6 } }