VAR-202210-0551
Vulnerability from variot - Updated: 2023-12-18 10:49A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.0), SCALANCE X201-3P IRT (All versions < V5.5.0), SCALANCE X201-3P IRT PRO (All versions < V5.5.0), SCALANCE X202-2IRT (All versions < V5.5.0), SCALANCE X202-2P IRT (All versions < V5.5.0), SCALANCE X202-2P IRT PRO (All versions < V5.5.0), SCALANCE X204-2 (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X204IRT (All versions < V5.5.0), SCALANCE X204IRT PRO (All versions < V5.5.0), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < V5.5.0), SCALANCE XF202-2P IRT (All versions < V5.5.0), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204-2 (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < V5.5.0), SCALANCE XF204IRT (All versions < V5.5.0), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (All versions < V5.5.0). There is a cross-site scripting vulnerability on the affected devices, that if used by a threat actor, it could result in session hijacking. scalance x200-4p irt firmware, SCALANCE X201-3P IRT firmware, SCALANCE X201-3P IRT PRO Multiple Siemens products such as firmware contain a cross-site scripting vulnerability.Information may be obtained and information may be tampered with
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202210-0551",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "scalance x201-3p irt pro",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.0"
},
{
"model": "scalance x200-4p irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.0"
},
{
"model": "scalance x216",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.2.5"
},
{
"model": "scalance x202-2irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.0"
},
{
"model": "scalance xf208",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.2.5"
},
{
"model": "scalance xf206-1",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.2.5"
},
{
"model": "scalance x204-2",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.2.5"
},
{
"model": "scalance xf202-2p irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.0"
},
{
"model": "scalance xf204-2ba irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.0"
},
{
"model": "scalance x204-2fm",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.2.5"
},
{
"model": "scalance x202-2p irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.0"
},
{
"model": "scalance x204-2ld ts",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.2.5"
},
{
"model": "siplus net scalance x202-2p irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.0"
},
{
"model": "scalance x206-1ld",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.2.5"
},
{
"model": "scalance x204-2ld",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.2.5"
},
{
"model": "scalance xf204-2",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.2.5"
},
{
"model": "scalance xf204",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.2.5"
},
{
"model": "scalance x206-1",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.2.5"
},
{
"model": "scalance x224",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.2.5"
},
{
"model": "scalance x202-2p irt pro",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.0"
},
{
"model": "scalance x204irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.0"
},
{
"model": "scalance x208pro",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.2.5"
},
{
"model": "scalance xf201-3p irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.0"
},
{
"model": "scalance x212-2ld",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.2.5"
},
{
"model": "scalance xf204irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.0"
},
{
"model": "scalance x204irt pro",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.0"
},
{
"model": "scalance x212-2",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.2.5"
},
{
"model": "scalance x204-2ts",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.2.5"
},
{
"model": "scalance x201-3p irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.0"
},
{
"model": "scalance x208",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.2.5"
},
{
"model": "scalance x201-3p irt",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x201-3p irt pro",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x204-2ts",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x204irt pro",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x206-1ld",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x202-2irt",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x208pro",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x212-2ld",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x200-4p irt",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x202-2p irt",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x202-2p irt pro",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x204-2ld ts",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x204irt",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x216",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x204-2fm",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x206-1",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x204-2ld",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x208",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x204-2",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x212-2",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018712"
},
{
"db": "NVD",
"id": "CVE-2022-40631"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x200-4p_irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x200-4p_irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x201-3p_irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x201-3p_irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x201-3p_irt_pro_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x201-3p_irt_pro:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2p_irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2p_irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2p_irt_pro_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2p_irt_pro:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x204-2_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.2.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x204-2:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x204-2fm_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.2.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x204-2fm:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x204-2ld_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.2.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x204-2ld:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x204-2ld_ts_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.2.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x204-2ld_ts:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x204-2ts_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.2.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x204-2ts:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x204irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x204irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x204irt_pro_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x204irt_pro:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x206-1_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.2.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x206-1:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x206-1ld_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.2.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x206-1ld:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x208_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.2.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x208:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x208pro_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.2.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x208pro:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x212-2_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.2.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x212-2:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x212-2ld_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.2.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x212-2ld:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x216_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.2.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x216:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x224_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.2.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x224:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xf201-3p_irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf201-3p_irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xf202-2p_irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf202-2p_irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.2.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.2.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xf206-1_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.2.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf206-1:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xf208_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.2.5",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf208:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:siplus_net_scalance_x202-2p_irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:siplus_net_scalance_x202-2p_irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-40631"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens reported this vulnerability to CISA.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-504"
}
],
"trust": 0.6
},
"cve": "CVE-2022-40631",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 6.1,
"baseSeverity": "Medium",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "CVE-2022-40631",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "None",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-40631",
"trust": 1.8,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202210-504",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018712"
},
{
"db": "NVD",
"id": "CVE-2022-40631"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-504"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.0), SCALANCE X202-2IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.0), SCALANCE X204-2 (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X204IRT (All versions \u003c V5.5.0), SCALANCE X204IRT PRO (All versions \u003c V5.5.0), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c V5.5.0), SCALANCE XF202-2P IRT (All versions \u003c V5.5.0), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204-2 (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.0), SCALANCE XF204IRT (All versions \u003c V5.5.0), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (All versions \u003c V5.5.0). There is a cross-site scripting vulnerability on the affected devices, that if used by a threat actor, it could result in session hijacking. scalance x200-4p irt firmware, SCALANCE X201-3P IRT firmware, SCALANCE X201-3P IRT PRO Multiple Siemens products such as firmware contain a cross-site scripting vulnerability.Information may be obtained and information may be tampered with",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-40631"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018712"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-40631",
"trust": 3.2
},
{
"db": "SIEMENS",
"id": "SSA-501891",
"trust": 2.4
},
{
"db": "ICS CERT",
"id": "ICSA-22-286-15",
"trust": 1.4
},
{
"db": "JVN",
"id": "JVNVU92214181",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-018712",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202210-504",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018712"
},
{
"db": "NVD",
"id": "CVE-2022-40631"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-504"
}
]
},
"id": "VAR-202210-0551",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.508912065
},
"last_update_date": "2023-12-18T10:49:36.041000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Siemens Scalance X-200 Fixes for cross-site scripting vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=210803"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-504"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-79",
"trust": 1.0
},
{
"problemtype": "Cross-site scripting (CWE-79) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018712"
},
{
"db": "NVD",
"id": "CVE-2022-40631"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-501891.pdf"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu92214181/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-40631"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-286-15"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-286-15"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-40631/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018712"
},
{
"db": "NVD",
"id": "CVE-2022-40631"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-504"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018712"
},
{
"db": "NVD",
"id": "CVE-2022-40631"
},
{
"db": "CNNVD",
"id": "CNNVD-202210-504"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-10-23T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-018712"
},
{
"date": "2022-10-11T11:15:10.997000",
"db": "NVD",
"id": "CVE-2022-40631"
},
{
"date": "2022-10-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202210-504"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-10-23T02:34:00",
"db": "JVNDB",
"id": "JVNDB-2022-018712"
},
{
"date": "2022-10-14T17:07:54.777000",
"db": "NVD",
"id": "CVE-2022-40631"
},
{
"date": "2022-10-17T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202210-504"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-504"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Cross-site scripting vulnerability in multiple Siemens products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-018712"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "XSS",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202210-504"
}
],
"trust": 0.6
}
}
VAR-202304-0694
Vulnerability from variot - Updated: 2023-12-18 10:48A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SIPLUS NET SCALANCE X202-2P IRT (All versions < V5.5.2). The SSH server on affected devices is configured to offer weak ciphers by default.
This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data passed over the connection between legitimate clients and the affected device. SCALANCE X200-4P IRT firmware, SCALANCE X201-3P IRT firmware, SCALANCE X201-3P IRT PRO Multiple Siemens products, including firmware, have vulnerabilities related to encryption strength.Information may be obtained and information may be tampered with
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202304-0694",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "scalance xf201-3p irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.2"
},
{
"model": "scalance xf204irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.2"
},
{
"model": "scalance xf204-2ba irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.2"
},
{
"model": "scalance x204irt pro",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.2"
},
{
"model": "scalance xf202-2p irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.2"
},
{
"model": "scalance x202-2p irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.2"
},
{
"model": "siplus net scalance x202-2p irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.2"
},
{
"model": "scalance x201-3p irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.2"
},
{
"model": "scalance x201-3p irt pro",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.2"
},
{
"model": "scalance x200-4p irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.2"
},
{
"model": "scalance x204irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.2"
},
{
"model": "scalance x202-2irt",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.2"
},
{
"model": "scalance x202-2p irt pro",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "5.5.2"
},
{
"model": "scalance x201-3p irt pro",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance xf204irt",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x201-3p irt",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance xf201-3p irt",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x200-4p irt",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance xf204-2ba irt",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x204irt pro",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "siplus net scalance x202-2p irt",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance xf202-2p irt",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x202-2irt",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x202-2p irt pro",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x202-2p irt",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "scalance x204irt",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006528"
},
{
"db": "NVD",
"id": "CVE-2023-29054"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x200-4p_irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x200-4p_irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x201-3p_irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x201-3p_irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x201-3p_irt_pro_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x201-3p_irt_pro:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2p_irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2p_irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x202-2p_irt_pro_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x202-2p_irt_pro:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x204irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x204irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x204irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x204irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_x204irt_pro_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_x204irt_pro:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xf201-3p_irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf201-3p_irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xf202-2p_irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf202-2p_irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:scalance_xf204irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:scalance_xf204irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:siplus_net_scalance_x202-2p_irt_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "5.5.2",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:siplus_net_scalance_x202-2p_irt:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-29054"
}
]
},
"cve": "CVE-2023-29054",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.2,
"impactScore": 5.2,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
{
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"author": "productcert@siemens.com",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 1.2,
"impactScore": 5.5,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "High",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 7.4,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-29054",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-29054",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "productcert@siemens.com",
"id": "CVE-2023-29054",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-202304-793",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006528"
},
{
"db": "NVD",
"id": "CVE-2023-29054"
},
{
"db": "NVD",
"id": "CVE-2023-29054"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-793"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT PRO (All versions \u003c V5.5.2), SCALANCE XF201-3P IRT (All versions \u003c V5.5.2), SCALANCE XF202-2P IRT (All versions \u003c V5.5.2), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.2), SCALANCE XF204IRT (All versions \u003c V5.5.2), SIPLUS NET SCALANCE X202-2P IRT (All versions \u003c V5.5.2). The SSH server on affected devices is configured to offer weak ciphers by default. \r\n\r\nThis could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data\r\npassed over the connection between legitimate clients and the affected device. SCALANCE X200-4P IRT firmware, SCALANCE X201-3P IRT firmware, SCALANCE X201-3P IRT PRO Multiple Siemens products, including firmware, have vulnerabilities related to encryption strength.Information may be obtained and information may be tampered with",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-29054"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006528"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-29054",
"trust": 3.2
},
{
"db": "SIEMENS",
"id": "SSA-479249",
"trust": 2.4
},
{
"db": "ICS CERT",
"id": "ICSA-23-103-05",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU94715153",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006528",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202304-793",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006528"
},
{
"db": "NVD",
"id": "CVE-2023-29054"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-793"
}
]
},
"id": "VAR-202304-0694",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.523408153
},
"last_update_date": "2023-12-18T10:48:37.092000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Siemens SCALANCE Fixes for encryption problem vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=234432"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-793"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-326",
"trust": 1.0
},
{
"problemtype": "Inappropriate cryptographic strength (CWE-326) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006528"
},
{
"db": "NVD",
"id": "CVE-2023-29054"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479249.pdf"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu94715153/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-29054"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-103-05"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-29054/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006528"
},
{
"db": "NVD",
"id": "CVE-2023-29054"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-793"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006528"
},
{
"db": "NVD",
"id": "CVE-2023-29054"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-793"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-15T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-006528"
},
{
"date": "2023-04-11T10:15:18.517000",
"db": "NVD",
"id": "CVE-2023-29054"
},
{
"date": "2023-04-11T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-793"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-11-15T05:05:00",
"db": "JVNDB",
"id": "JVNDB-2023-006528"
},
{
"date": "2023-04-20T18:43:29.747000",
"db": "NVD",
"id": "CVE-2023-29054"
},
{
"date": "2023-04-21T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-793"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-793"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Cryptographic strength vulnerabilities in multiple Siemens products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006528"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "encryption problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-793"
}
],
"trust": 0.6
}
}
CVE-2023-29054 (GCVE-0-2023-29054)
Vulnerability from cvelistv5 – Published: 2023-04-11 09:03 – Updated: 2025-02-07 16:49- CWE-326 - Inadequate Encryption Strength
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SCALANCE X200-4P IRT |
Affected:
All versions < V5.5.2
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:00:14.631Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479249.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29054",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-07T16:49:12.465183Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-07T16:49:26.184Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SCALANCE X200-4P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X201-3P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X201-3P IRT PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X202-2IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X202-2IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X202-2P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X202-2P IRT PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X204IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X204IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X204IRT PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF201-3P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF202-2P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE X202-2P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT PRO (All versions \u003c V5.5.2), SCALANCE XF201-3P IRT (All versions \u003c V5.5.2), SCALANCE XF202-2P IRT (All versions \u003c V5.5.2), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.2), SCALANCE XF204IRT (All versions \u003c V5.5.2), SIPLUS NET SCALANCE X202-2P IRT (All versions \u003c V5.5.2). The SSH server on affected devices is configured to offer weak ciphers by default.\r\n\r\nThis could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data\r\npassed over the connection between legitimate clients and the affected device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H/E:P/RL:U/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "CWE-326: Inadequate Encryption Strength",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T09:03:08.813Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479249.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-29054",
"datePublished": "2023-04-11T09:03:08.813Z",
"dateReserved": "2023-03-30T12:04:26.539Z",
"dateUpdated": "2025-02-07T16:49:26.184Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-40631 (GCVE-0-2022-40631)
Vulnerability from cvelistv5 – Published: 2022-10-11 00:00 – Updated: 2024-08-03 12:21- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SCALANCE X200-4P IRT |
Affected:
All versions < V5.5.0
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T12:21:46.592Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-501891.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SCALANCE X200-4P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE X201-3P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE X201-3P IRT PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE X202-2IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE X202-2P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE X202-2P IRT PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE X204-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X204-2FM",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X204-2LD",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X204-2LD TS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X204-2TS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X204IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE X204IRT PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE X206-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X206-1LD",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X208PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X212-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X212-2LD",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X224",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE XF201-3P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE XF202-2P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE XF204-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE XF204-2BA IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE XF204IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE XF206-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE XF208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SIPLUS NET SCALANCE X202-2P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.0), SCALANCE X202-2IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.0), SCALANCE X204-2 (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X204IRT (All versions \u003c V5.5.0), SCALANCE X204IRT PRO (All versions \u003c V5.5.0), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c V5.5.0), SCALANCE XF202-2P IRT (All versions \u003c V5.5.0), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204-2 (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.0), SCALANCE XF204IRT (All versions \u003c V5.5.0), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (All versions \u003c V5.5.0). There is a cross-site scripting vulnerability on the affected devices, that if used by a threat actor, it could result in session hijacking."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-11T00:00:00",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-501891.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-40631",
"datePublished": "2022-10-11T00:00:00",
"dateReserved": "2022-09-13T00:00:00",
"dateUpdated": "2024-08-03T12:21:46.592Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-29054 (GCVE-0-2023-29054)
Vulnerability from nvd – Published: 2023-04-11 09:03 – Updated: 2025-02-07 16:49- CWE-326 - Inadequate Encryption Strength
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SCALANCE X200-4P IRT |
Affected:
All versions < V5.5.2
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T14:00:14.631Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479249.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-29054",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-07T16:49:12.465183Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-07T16:49:26.184Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SCALANCE X200-4P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X201-3P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X201-3P IRT PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X202-2IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X202-2IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X202-2P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X202-2P IRT PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X204IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X204IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE X204IRT PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF201-3P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF202-2P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204-2BA IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE XF204IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS NET SCALANCE X202-2P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT (All versions \u003c V5.5.2), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT (All versions \u003c V5.5.2), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT (All versions \u003c V5.5.2), SCALANCE X204IRT PRO (All versions \u003c V5.5.2), SCALANCE XF201-3P IRT (All versions \u003c V5.5.2), SCALANCE XF202-2P IRT (All versions \u003c V5.5.2), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.2), SCALANCE XF204IRT (All versions \u003c V5.5.2), SIPLUS NET SCALANCE X202-2P IRT (All versions \u003c V5.5.2). The SSH server on affected devices is configured to offer weak ciphers by default.\r\n\r\nThis could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data\r\npassed over the connection between legitimate clients and the affected device."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:H/E:P/RL:U/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "CWE-326: Inadequate Encryption Strength",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-11T09:03:08.813Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-479249.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2023-29054",
"datePublished": "2023-04-11T09:03:08.813Z",
"dateReserved": "2023-03-30T12:04:26.539Z",
"dateUpdated": "2025-02-07T16:49:26.184Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-40631 (GCVE-0-2022-40631)
Vulnerability from nvd – Published: 2022-10-11 00:00 – Updated: 2024-08-03 12:21- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SCALANCE X200-4P IRT |
Affected:
All versions < V5.5.0
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T12:21:46.592Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-501891.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SCALANCE X200-4P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE X201-3P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE X201-3P IRT PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE X202-2IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE X202-2P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE X202-2P IRT PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE X204-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X204-2FM",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X204-2LD",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X204-2LD TS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X204-2TS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X204IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE X204IRT PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE X206-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X206-1LD",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X208PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X212-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X212-2LD",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X216",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE X224",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE XF201-3P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE XF202-2P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE XF204",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE XF204-2",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE XF204-2BA IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE XF204IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
},
{
"product": "SCALANCE XF206-1",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SCALANCE XF208",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.2.5"
}
]
},
{
"product": "SIPLUS NET SCALANCE X202-2P IRT",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.5.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.0), SCALANCE X202-2IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.0), SCALANCE X204-2 (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X204IRT (All versions \u003c V5.5.0), SCALANCE X204IRT PRO (All versions \u003c V5.5.0), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c V5.5.0), SCALANCE XF202-2P IRT (All versions \u003c V5.5.0), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204-2 (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.0), SCALANCE XF204IRT (All versions \u003c V5.5.0), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (All versions \u003c V5.5.0). There is a cross-site scripting vulnerability on the affected devices, that if used by a threat actor, it could result in session hijacking."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-11T00:00:00",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-501891.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-40631",
"datePublished": "2022-10-11T00:00:00",
"dateReserved": "2022-09-13T00:00:00",
"dateUpdated": "2024-08-03T12:21:46.592Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",