cve-2022-40631
Vulnerability from cvelistv5
Published
2022-10-11 00:00
Modified
2024-08-03 12:21
Severity ?
Summary
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.0), SCALANCE X201-3P IRT (All versions < V5.5.0), SCALANCE X201-3P IRT PRO (All versions < V5.5.0), SCALANCE X202-2IRT (All versions < V5.5.0), SCALANCE X202-2P IRT (All versions < V5.5.0), SCALANCE X202-2P IRT PRO (All versions < V5.5.0), SCALANCE X204-2 (All versions < V5.2.5), SCALANCE X204-2FM (All versions < V5.2.5), SCALANCE X204-2LD (All versions < V5.2.5), SCALANCE X204-2LD TS (All versions < V5.2.5), SCALANCE X204-2TS (All versions < V5.2.5), SCALANCE X204IRT (All versions < V5.5.0), SCALANCE X204IRT PRO (All versions < V5.5.0), SCALANCE X206-1 (All versions < V5.2.5), SCALANCE X206-1LD (All versions < V5.2.5), SCALANCE X208 (All versions < V5.2.5), SCALANCE X208PRO (All versions < V5.2.5), SCALANCE X212-2 (All versions < V5.2.5), SCALANCE X212-2LD (All versions < V5.2.5), SCALANCE X216 (All versions < V5.2.5), SCALANCE X224 (All versions < V5.2.5), SCALANCE XF201-3P IRT (All versions < V5.5.0), SCALANCE XF202-2P IRT (All versions < V5.5.0), SCALANCE XF204 (All versions < V5.2.5), SCALANCE XF204-2 (All versions < V5.2.5), SCALANCE XF204-2BA IRT (All versions < V5.5.0), SCALANCE XF204IRT (All versions < V5.5.0), SCALANCE XF206-1 (All versions < V5.2.5), SCALANCE XF208 (All versions < V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (All versions < V5.5.0). There is a cross-site scripting vulnerability on the affected devices, that if used by a threat actor, it could result in session hijacking.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T12:21:46.592Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-501891.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X200-4P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "product": "SCALANCE X201-3P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "product": "SCALANCE X201-3P IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "product": "SCALANCE X202-2IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "product": "SCALANCE X202-2P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "product": "SCALANCE X202-2P IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "product": "SCALANCE X204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "product": "SCALANCE X204-2FM",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "product": "SCALANCE X204-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "product": "SCALANCE X204-2LD TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "product": "SCALANCE X204-2TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "product": "SCALANCE X204IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "product": "SCALANCE X204IRT PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "product": "SCALANCE X206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "product": "SCALANCE X206-1LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "product": "SCALANCE X208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "product": "SCALANCE X208PRO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "product": "SCALANCE X212-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "product": "SCALANCE X212-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "product": "SCALANCE X216",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "product": "SCALANCE X224",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "product": "SCALANCE XF201-3P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "product": "SCALANCE XF202-2P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "product": "SCALANCE XF204",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "product": "SCALANCE XF204-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "product": "SCALANCE XF204-2BA IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "product": "SCALANCE XF204IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "product": "SCALANCE XF206-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "product": "SCALANCE XF208",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE X202-2P IRT",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.0), SCALANCE X202-2IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.0), SCALANCE X204-2 (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X204IRT (All versions \u003c V5.5.0), SCALANCE X204IRT PRO (All versions \u003c V5.5.0), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c V5.5.0), SCALANCE XF202-2P IRT (All versions \u003c V5.5.0), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204-2 (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.0), SCALANCE XF204IRT (All versions \u003c V5.5.0), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (All versions \u003c V5.5.0). There is a cross-site scripting vulnerability on the affected devices, that if used by a threat actor, it could result in session hijacking."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-11T00:00:00",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-501891.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-40631",
    "datePublished": "2022-10-11T00:00:00",
    "dateReserved": "2022-09-13T00:00:00",
    "dateUpdated": "2024-08-03T12:21:46.592Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-40631\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-10-11T11:15:10.997\",\"lastModified\":\"2022-10-14T17:07:54.777\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SCALANCE X200-4P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT (All versions \u003c V5.5.0), SCALANCE X201-3P IRT PRO (All versions \u003c V5.5.0), SCALANCE X202-2IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT (All versions \u003c V5.5.0), SCALANCE X202-2P IRT PRO (All versions \u003c V5.5.0), SCALANCE X204-2 (All versions \u003c V5.2.5), SCALANCE X204-2FM (All versions \u003c V5.2.5), SCALANCE X204-2LD (All versions \u003c V5.2.5), SCALANCE X204-2LD TS (All versions \u003c V5.2.5), SCALANCE X204-2TS (All versions \u003c V5.2.5), SCALANCE X204IRT (All versions \u003c V5.5.0), SCALANCE X204IRT PRO (All versions \u003c V5.5.0), SCALANCE X206-1 (All versions \u003c V5.2.5), SCALANCE X206-1LD (All versions \u003c V5.2.5), SCALANCE X208 (All versions \u003c V5.2.5), SCALANCE X208PRO (All versions \u003c V5.2.5), SCALANCE X212-2 (All versions \u003c V5.2.5), SCALANCE X212-2LD (All versions \u003c V5.2.5), SCALANCE X216 (All versions \u003c V5.2.5), SCALANCE X224 (All versions \u003c V5.2.5), SCALANCE XF201-3P IRT (All versions \u003c V5.5.0), SCALANCE XF202-2P IRT (All versions \u003c V5.5.0), SCALANCE XF204 (All versions \u003c V5.2.5), SCALANCE XF204-2 (All versions \u003c V5.2.5), SCALANCE XF204-2BA IRT (All versions \u003c V5.5.0), SCALANCE XF204IRT (All versions \u003c V5.5.0), SCALANCE XF206-1 (All versions \u003c V5.2.5), SCALANCE XF208 (All versions \u003c V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (All versions \u003c V5.5.0). There is a cross-site scripting vulnerability on the affected devices, that if used by a threat actor, it could result in session hijacking.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SCALANCE X200-4P IRT (Todas las versiones anteriores a V5.5.0), SCALANCE X201-3P IRT (Todas las versiones anteriores a V5.5.0), SCALANCE X201-3P IRT PRO (Todas las versiones anteriores a V5. 5.0), SCALANCE X202-2IRT (Todas las versiones anteriores a V5.5.0), SCALANCE X202-2P IRT (Todas las versiones anteriores a V5.5.0), SCALANCE X202-2P IRT PRO (Todas las versiones anteriores a V5.5. 0), SCALANCE X204-2 (Todas las versiones anteriores a V5.2.5), SCALANCE X204-2FM (Todas las versiones anteriores a V5.2.5), SCALANCE X204-2LD (Todas las versiones anteriores a V5.2.5), SCALANCE X204-2LD TS (Todas las versiones anteriores a V5. 2.5), SCALANCE X204-2TS (Todas las versiones anteriores a V5.2.5), SCALANCE X204IRT (Todas las versiones anteriores a V5.5.0), SCALANCE X204IRT PRO (Todas las versiones anteriores a V5.5.0), SCALANCE X206-1 (Todas las versiones anteriores a V5.2. 5), SCALANCE X206-1LD (Todas las versiones anteriores a V5.2.5), SCALANCE X208 (Todas las versiones anteriores a V5.2.5), SCALANCE X208PRO (Todas las versiones anteriores a V5.2.5), SCALANCE X212-2 (Todas las versiones anteriores a V5.2. 5), SCALANCE X212-2LD (Todas las versiones anteriores a V5.2.5), SCALANCE X216 (Todas las versiones anteriores a V5.2.5), SCALANCE X224 (Todas las versiones anteriores a V5.2.5), SCALANCE XF201-3P IRT (Todas las versiones anteriores a V5.5. 0), SCALANCE XF202-2P IRT (Todas las versiones anteriores a V5.5.0), SCALANCE XF204 (Todas las versiones anteriores a V5.2.5), SCALANCE XF204-2 (Todas las versiones anteriores a V5.2.5), SCALANCE XF204-2BA IRT (Todas las versiones anteriores a V5.5. 0), SCALANCE XF204IRT (Todas las versiones anteriores a V5.5.0), SCALANCE XF206-1 (Todas las versiones anteriores a V5.2.5), SCALANCE XF208 (Todas las versiones anteriores a V5.2.5), SIPLUS NET SCALANCE X202-2P IRT (Todas las versiones anteriores a V5.5.0). Se presenta una vulnerabilidad de tipo cross-site scripting en los dispositivos afectados, que si es usada por un actor de amenaza, podr\u00eda resultar en un secuestro de sesi\u00f3n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x200-4p_irt_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.5.0\",\"matchCriteriaId\":\"9718A3C6-D0FD-4A3B-95B1-8694B2B06060\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x200-4p_irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8B9CBC72-92D9-4B3A-884F-33124C457016\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x201-3p_irt_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.5.0\",\"matchCriteriaId\":\"EA86FF0D-7B16-4991-B4A5-AF33BF40693A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x201-3p_irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3268CF75-6DAB-416A-B19B-2A8F95C268CF\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x201-3p_irt_pro_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.5.0\",\"matchCriteriaId\":\"CA2326FF-5125-44F5-871C-2DC505E2B299\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x201-3p_irt_pro:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"492E8AC1-338B-4AC3-90C7-1FADCD4528C4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x202-2irt_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.5.0\",\"matchCriteriaId\":\"666FACCE-89EB-4E5D-A718-F1D4945F7DF4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x202-2irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A8B1D979-038F-42F4-AB7D-E0664D051B4E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x202-2p_irt_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.5.0\",\"matchCriteriaId\":\"0475BCB9-BD28-454F-8898-C238446AD00B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x202-2p_irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CEB62730-E759-455A-A308-F9DB084B35B5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x202-2p_irt_pro_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.5.0\",\"matchCriteriaId\":\"29C03AD0-7A60-4BFB-A0D3-BABB9717F1A1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x202-2p_irt_pro:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F4726901-34BF-4F70-80A6-71648A4A29FB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x204-2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.5\",\"matchCriteriaId\":\"ACE1A821-8F0A-4B96-AC8A-B219215014B1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x204-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E38CE5A4-3EB1-4E93-BEB7-520E08DA6720\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x204-2fm_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.5\",\"matchCriteriaId\":\"54201E08-15E3-4C93-9A0D-DC376B7C8D88\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x204-2fm:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1FCBC784-8EA0-4C6C-B504-DFC164028E4B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x204-2ld_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.5\",\"matchCriteriaId\":\"75220631-DD7D-4E86-8405-F98340FFE27C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x204-2ld:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2BE27611-53E7-4162-8630-5BC334B02E37\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x204-2ld_ts_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.5\",\"matchCriteriaId\":\"3032A499-DFD5-4FEA-8AC6-E661781387AB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x204-2ld_ts:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1FDEBD6B-6BE4-4FAD-A4E6-BE762595434D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x204-2ts_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.5\",\"matchCriteriaId\":\"A493C49A-8BF9-43E5-98D5-55E5390A36A5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x204-2ts:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E5FFC1E9-4326-4F41-A86A-C52AB6A9A674\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x204irt_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.5.0\",\"matchCriteriaId\":\"0C94D093-9D17-47C9-A7F6-28FF241BF874\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x204irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6716DCDE-BD3F-4BA2-A66A-A0C14C6A3C15\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x204irt_pro_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.5.0\",\"matchCriteriaId\":\"2F0BEFA7-9795-4009-B055-704BF3C97B6B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x204irt_pro:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1769DB7A-F832-4D89-8ED0-8677F750059D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x206-1_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.5\",\"matchCriteriaId\":\"E2C9747F-BEC3-486E-B553-3339F8B54C3A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x206-1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0A5BB0F2-DD4C-4AB4-9B8F-B2501B239080\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x206-1ld_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.5\",\"matchCriteriaId\":\"0C8D68AC-8F30-4919-ADB3-A6018458602B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x206-1ld:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6DFF7FB7-774B-45ED-8400-951230DF0511\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x208_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.5\",\"matchCriteriaId\":\"2BC1450A-92ED-451F-9890-4E18CA974485\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x208:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B3B574E2-F7BA-496B-887C-D25F386AA5E1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x208pro_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.5\",\"matchCriteriaId\":\"768320F0-10F5-4B36-AEB6-9DEEA43A30E8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x208pro:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DF2C60CF-4089-4993-A2CB-B7FBDAF81D62\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x212-2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.5\",\"matchCriteriaId\":\"31B8367C-5EAC-49F4-83B8-C7E3BD373092\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x212-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4E716A4E-50A9-4C52-8DA9-098F7506F4B5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x212-2ld_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.5\",\"matchCriteriaId\":\"55F50ABF-3E9A-4435-BAA4-7D11A2047D46\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x212-2ld:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C08CDEE3-43EB-475E-8571-6E12824714FD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x216_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.5\",\"matchCriteriaId\":\"BC643617-D0B7-4379-8ADB-2C2BACA4B165\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x216:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F0C4BAB5-E161-4B59-8A8C-369C7852A66E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x224_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.5\",\"matchCriteriaId\":\"F0189DF6-DA80-49FE-B09F-0C07D892518E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x224:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D2203895-BC4E-4B2F-9110-C2CD88A121F2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xf201-3p_irt_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.5.0\",\"matchCriteriaId\":\"B5557DB0-D3D8-4E53-BBA8-700B2BC336C0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xf201-3p_irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"41614C70-97B4-44C8-A441-530A413A26F9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xf202-2p_irt_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.5.0\",\"matchCriteriaId\":\"C1A7EDE9-B5F9-4471-8C5D-B1D590CB85FB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xf202-2p_irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6751FB7D-C72C-4321-B535-5880FE696FC3\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xf204_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.5\",\"matchCriteriaId\":\"8CD13707-1164-415E-9083-7946D151F1FC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xf204:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0F1AE867-67B4-4871-BF56-88017533A737\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xf204-2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.5\",\"matchCriteriaId\":\"3A09FF2D-F369-47B5-AEE4-A862BEDD9851\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xf204-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"69285324-4C0B-4BDC-B60D-F653679DD52D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.5.0\",\"matchCriteriaId\":\"786738CF-CA6C-4812-BD4D-595E249BFA76\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xf204-2ba_irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"99E6AFAA-B903-47BB-B0F3-7650B039C0FB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xf204irt_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.5.0\",\"matchCriteriaId\":\"4824C65E-E41B-4883-AAB5-011904AE463C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xf204irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"57E5489B-277A-4D02-B4AB-4DB65969EED2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xf206-1_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.5\",\"matchCriteriaId\":\"CFCDC84E-0695-409A-844B-D24024CC33F2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xf206-1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2B40D2EB-5C69-47FA-801B-DC48407D418C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_xf208_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.5\",\"matchCriteriaId\":\"A1DB6C03-71BF-4359-834B-384E78910E64\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_xf208:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"898613B2-4A9D-44B9-A3FC-4347A2AD7CAB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:siplus_net_scalance_x202-2p_irt_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.5.0\",\"matchCriteriaId\":\"AB92E2D3-8F6D-40F2-9536-8D7DD7FBC9A5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:siplus_net_scalance_x202-2p_irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1C3504F0-D0F4-4106-824E-A87E46DADC3B\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-501891.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.