Search criteria
14 vulnerabilities found for SmartClient modules Opcenter QL Home (SC) by Siemens
CVE-2024-41986 (GCVE-0-2024-41986)
Vulnerability from cvelistv5 – Published: 2025-08-12 11:16 – Updated: 2025-08-12 19:16
VLAI?
Summary
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application support insecure TLS 1.0 and 1.1 protocol. An attacker could achieve a man-in-the-middle attack and compromise confidentiality and integrity of data.
Severity ?
6.4 (Medium)
CWE
- CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SmartClient modules Opcenter QL Home (SC) |
Affected:
V13.2 , < V2506
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41986",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T19:16:25.144706Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T19:16:56.687Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SmartClient modules Opcenter QL Home (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Audit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Cockpit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions \u003e= V13.2 \u003c V2506), SOA Audit (All versions \u003e= V13.2 \u003c V2506), SOA Cockpit (All versions \u003e= V13.2 \u003c V2506). The affected application support insecure TLS 1.0 and 1.1 protocol. An attacker could achieve a man-in-the-middle attack and compromise confidentiality and integrity of data."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-327",
"description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:16:42.595Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-382999.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-41986",
"datePublished": "2025-08-12T11:16:42.595Z",
"dateReserved": "2024-07-25T12:46:30.322Z",
"dateUpdated": "2025-08-12T19:16:56.687Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-41985 (GCVE-0-2024-41985)
Vulnerability from cvelistv5 – Published: 2025-08-12 11:16 – Updated: 2025-08-12 19:25
VLAI?
Summary
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application does not expire the session without logout. This could allow an attacker to get unauthorized access if the session is left idle.
Severity ?
CWE
- CWE-613 - Insufficient Session Expiration
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SmartClient modules Opcenter QL Home (SC) |
Affected:
V13.2 , < V2506
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41985",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T19:24:10.939392Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T19:25:28.707Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SmartClient modules Opcenter QL Home (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Audit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Cockpit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions \u003e= V13.2 \u003c V2506), SOA Audit (All versions \u003e= V13.2 \u003c V2506), SOA Cockpit (All versions \u003e= V13.2 \u003c V2506). The affected application does not expire the session without logout. This could allow an attacker to get unauthorized access if the session is left idle."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 2.6,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 2.1,
"baseSeverity": "LOW",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-613",
"description": "CWE-613: Insufficient Session Expiration",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:16:41.301Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-382999.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-41985",
"datePublished": "2025-08-12T11:16:41.301Z",
"dateReserved": "2024-07-25T12:46:30.322Z",
"dateUpdated": "2025-08-12T19:25:28.707Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-41984 (GCVE-0-2024-41984)
Vulnerability from cvelistv5 – Published: 2025-08-12 11:16 – Updated: 2025-08-12 19:33
VLAI?
Summary
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application improperly handles error while accessing an inaccessible resource leading to exposing the system applications.
Severity ?
CWE
- CWE-209 - Generation of Error Message Containing Sensitive Information
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SmartClient modules Opcenter QL Home (SC) |
Affected:
V13.2 , < V2506
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41984",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T19:32:49.960577Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T19:33:52.329Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SmartClient modules Opcenter QL Home (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Audit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Cockpit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions \u003e= V13.2 \u003c V2506), SOA Audit (All versions \u003e= V13.2 \u003c V2506), SOA Cockpit (All versions \u003e= V13.2 \u003c V2506). The affected application improperly handles error while accessing an inaccessible resource leading to exposing the system applications."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 2.6,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 2.1,
"baseSeverity": "LOW",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:P/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-209",
"description": "CWE-209: Generation of Error Message Containing Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:16:39.989Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-382999.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-41984",
"datePublished": "2025-08-12T11:16:39.989Z",
"dateReserved": "2024-07-25T12:46:30.322Z",
"dateUpdated": "2025-08-12T19:33:52.329Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-41983 (GCVE-0-2024-41983)
Vulnerability from cvelistv5 – Published: 2025-08-12 11:16 – Updated: 2025-08-12 19:47
VLAI?
Summary
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application displays SQL statement in the error messages encountered during the generation of reports using Cockpit tool.
Severity ?
CWE
- CWE-209 - Generation of Error Message Containing Sensitive Information
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SmartClient modules Opcenter QL Home (SC) |
Affected:
V13.2 , < V2506
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41983",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T19:45:04.629537Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T19:47:22.459Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SmartClient modules Opcenter QL Home (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Audit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Cockpit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions \u003e= V13.2 \u003c V2506), SOA Audit (All versions \u003e= V13.2 \u003c V2506), SOA Cockpit (All versions \u003e= V13.2 \u003c V2506). The affected application displays SQL statement in the error messages encountered during the generation of reports using Cockpit tool."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.5,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-209",
"description": "CWE-209: Generation of Error Message Containing Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:16:38.616Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-382999.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-41983",
"datePublished": "2025-08-12T11:16:38.616Z",
"dateReserved": "2024-07-25T12:46:30.322Z",
"dateUpdated": "2025-08-12T19:47:22.459Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-41982 (GCVE-0-2024-41982)
Vulnerability from cvelistv5 – Published: 2025-08-12 11:16 – Updated: 2025-08-12 15:53
VLAI?
Summary
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application does not have adequate encryption of sensitive information. This could allow an authenticated attacker to gain access of sensitive information.
Severity ?
CWE
- CWE-311 - Missing Encryption of Sensitive Data
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SmartClient modules Opcenter QL Home (SC) |
Affected:
V13.2 , < V2506
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41982",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T15:53:08.764312Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T15:53:21.980Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SmartClient modules Opcenter QL Home (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Audit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Cockpit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions \u003e= V13.2 \u003c V2506), SOA Audit (All versions \u003e= V13.2 \u003c V2506), SOA Cockpit (All versions \u003e= V13.2 \u003c V2506). The affected application does not have adequate encryption of sensitive information. This could allow an authenticated attacker to gain access of sensitive information."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-311",
"description": "CWE-311: Missing Encryption of Sensitive Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:16:37.292Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-382999.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-41982",
"datePublished": "2025-08-12T11:16:37.292Z",
"dateReserved": "2024-07-25T12:46:30.322Z",
"dateUpdated": "2025-08-12T15:53:21.980Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-41980 (GCVE-0-2024-41980)
Vulnerability from cvelistv5 – Published: 2025-08-12 11:16 – Updated: 2025-08-12 15:54
VLAI?
Summary
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application do not encrypt the communication in LDAP interface by default. This could allow an authenticated attacker to gain unauthorized access to sensitive information.
Severity ?
CWE
- CWE-311 - Missing Encryption of Sensitive Data
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SmartClient modules Opcenter QL Home (SC) |
Affected:
V13.2 , < V2506
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41980",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T15:53:40.030449Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T15:54:00.509Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SmartClient modules Opcenter QL Home (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Audit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Cockpit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions \u003e= V13.2 \u003c V2506), SOA Audit (All versions \u003e= V13.2 \u003c V2506), SOA Cockpit (All versions \u003e= V13.2 \u003c V2506). The affected application do not encrypt the communication in LDAP interface by default. This could allow an authenticated attacker to gain unauthorized access to sensitive information."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.1,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 2,
"baseSeverity": "LOW",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:H/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-311",
"description": "CWE-311: Missing Encryption of Sensitive Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:16:35.999Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-382999.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-41980",
"datePublished": "2025-08-12T11:16:35.999Z",
"dateReserved": "2024-07-25T12:46:30.322Z",
"dateUpdated": "2025-08-12T15:54:00.509Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-41979 (GCVE-0-2024-41979)
Vulnerability from cvelistv5 – Published: 2025-08-12 11:16 – Updated: 2025-08-12 15:54
VLAI?
Summary
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application does not enforce mandatory authorization on some functionality level at server side. This could allow an authenticated attacker to gain complete access of the application.
Severity ?
CWE
- CWE-863 - Incorrect Authorization
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SmartClient modules Opcenter QL Home (SC) |
Affected:
V13.2 , < V2506
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41979",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T15:54:24.954678Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T15:54:33.400Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SmartClient modules Opcenter QL Home (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Audit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Cockpit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions \u003e= V13.2 \u003c V2506), SOA Audit (All versions \u003e= V13.2 \u003c V2506), SOA Cockpit (All versions \u003e= V13.2 \u003c V2506). The affected application does not enforce mandatory authorization on some functionality level at server side. This could allow an authenticated attacker to gain complete access of the application."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863: Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:16:34.660Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-382999.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-41979",
"datePublished": "2025-08-12T11:16:34.660Z",
"dateReserved": "2024-07-25T12:46:30.321Z",
"dateUpdated": "2025-08-12T15:54:33.400Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-41986 (GCVE-0-2024-41986)
Vulnerability from nvd – Published: 2025-08-12 11:16 – Updated: 2025-08-12 19:16
VLAI?
Summary
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application support insecure TLS 1.0 and 1.1 protocol. An attacker could achieve a man-in-the-middle attack and compromise confidentiality and integrity of data.
Severity ?
6.4 (Medium)
CWE
- CWE-327 - Use of a Broken or Risky Cryptographic Algorithm
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SmartClient modules Opcenter QL Home (SC) |
Affected:
V13.2 , < V2506
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41986",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T19:16:25.144706Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T19:16:56.687Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SmartClient modules Opcenter QL Home (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Audit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Cockpit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions \u003e= V13.2 \u003c V2506), SOA Audit (All versions \u003e= V13.2 \u003c V2506), SOA Cockpit (All versions \u003e= V13.2 \u003c V2506). The affected application support insecure TLS 1.0 and 1.1 protocol. An attacker could achieve a man-in-the-middle attack and compromise confidentiality and integrity of data."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-327",
"description": "CWE-327: Use of a Broken or Risky Cryptographic Algorithm",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:16:42.595Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-382999.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-41986",
"datePublished": "2025-08-12T11:16:42.595Z",
"dateReserved": "2024-07-25T12:46:30.322Z",
"dateUpdated": "2025-08-12T19:16:56.687Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-41985 (GCVE-0-2024-41985)
Vulnerability from nvd – Published: 2025-08-12 11:16 – Updated: 2025-08-12 19:25
VLAI?
Summary
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application does not expire the session without logout. This could allow an attacker to get unauthorized access if the session is left idle.
Severity ?
CWE
- CWE-613 - Insufficient Session Expiration
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SmartClient modules Opcenter QL Home (SC) |
Affected:
V13.2 , < V2506
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41985",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T19:24:10.939392Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T19:25:28.707Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SmartClient modules Opcenter QL Home (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Audit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Cockpit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions \u003e= V13.2 \u003c V2506), SOA Audit (All versions \u003e= V13.2 \u003c V2506), SOA Cockpit (All versions \u003e= V13.2 \u003c V2506). The affected application does not expire the session without logout. This could allow an attacker to get unauthorized access if the session is left idle."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 2.6,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 2.1,
"baseSeverity": "LOW",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-613",
"description": "CWE-613: Insufficient Session Expiration",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:16:41.301Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-382999.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-41985",
"datePublished": "2025-08-12T11:16:41.301Z",
"dateReserved": "2024-07-25T12:46:30.322Z",
"dateUpdated": "2025-08-12T19:25:28.707Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-41984 (GCVE-0-2024-41984)
Vulnerability from nvd – Published: 2025-08-12 11:16 – Updated: 2025-08-12 19:33
VLAI?
Summary
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application improperly handles error while accessing an inaccessible resource leading to exposing the system applications.
Severity ?
CWE
- CWE-209 - Generation of Error Message Containing Sensitive Information
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SmartClient modules Opcenter QL Home (SC) |
Affected:
V13.2 , < V2506
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41984",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T19:32:49.960577Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T19:33:52.329Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SmartClient modules Opcenter QL Home (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Audit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Cockpit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions \u003e= V13.2 \u003c V2506), SOA Audit (All versions \u003e= V13.2 \u003c V2506), SOA Cockpit (All versions \u003e= V13.2 \u003c V2506). The affected application improperly handles error while accessing an inaccessible resource leading to exposing the system applications."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 2.6,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 2.1,
"baseSeverity": "LOW",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:N/UI:P/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-209",
"description": "CWE-209: Generation of Error Message Containing Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:16:39.989Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-382999.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-41984",
"datePublished": "2025-08-12T11:16:39.989Z",
"dateReserved": "2024-07-25T12:46:30.322Z",
"dateUpdated": "2025-08-12T19:33:52.329Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-41983 (GCVE-0-2024-41983)
Vulnerability from nvd – Published: 2025-08-12 11:16 – Updated: 2025-08-12 19:47
VLAI?
Summary
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application displays SQL statement in the error messages encountered during the generation of reports using Cockpit tool.
Severity ?
CWE
- CWE-209 - Generation of Error Message Containing Sensitive Information
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SmartClient modules Opcenter QL Home (SC) |
Affected:
V13.2 , < V2506
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41983",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T19:45:04.629537Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T19:47:22.459Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SmartClient modules Opcenter QL Home (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Audit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Cockpit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions \u003e= V13.2 \u003c V2506), SOA Audit (All versions \u003e= V13.2 \u003c V2506), SOA Cockpit (All versions \u003e= V13.2 \u003c V2506). The affected application displays SQL statement in the error messages encountered during the generation of reports using Cockpit tool."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.5,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-209",
"description": "CWE-209: Generation of Error Message Containing Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:16:38.616Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-382999.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-41983",
"datePublished": "2025-08-12T11:16:38.616Z",
"dateReserved": "2024-07-25T12:46:30.322Z",
"dateUpdated": "2025-08-12T19:47:22.459Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-41982 (GCVE-0-2024-41982)
Vulnerability from nvd – Published: 2025-08-12 11:16 – Updated: 2025-08-12 15:53
VLAI?
Summary
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application does not have adequate encryption of sensitive information. This could allow an authenticated attacker to gain access of sensitive information.
Severity ?
CWE
- CWE-311 - Missing Encryption of Sensitive Data
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SmartClient modules Opcenter QL Home (SC) |
Affected:
V13.2 , < V2506
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41982",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T15:53:08.764312Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T15:53:21.980Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SmartClient modules Opcenter QL Home (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Audit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Cockpit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions \u003e= V13.2 \u003c V2506), SOA Audit (All versions \u003e= V13.2 \u003c V2506), SOA Cockpit (All versions \u003e= V13.2 \u003c V2506). The affected application does not have adequate encryption of sensitive information. This could allow an authenticated attacker to gain access of sensitive information."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-311",
"description": "CWE-311: Missing Encryption of Sensitive Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:16:37.292Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-382999.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-41982",
"datePublished": "2025-08-12T11:16:37.292Z",
"dateReserved": "2024-07-25T12:46:30.322Z",
"dateUpdated": "2025-08-12T15:53:21.980Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-41980 (GCVE-0-2024-41980)
Vulnerability from nvd – Published: 2025-08-12 11:16 – Updated: 2025-08-12 15:54
VLAI?
Summary
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application do not encrypt the communication in LDAP interface by default. This could allow an authenticated attacker to gain unauthorized access to sensitive information.
Severity ?
CWE
- CWE-311 - Missing Encryption of Sensitive Data
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SmartClient modules Opcenter QL Home (SC) |
Affected:
V13.2 , < V2506
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41980",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T15:53:40.030449Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T15:54:00.509Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SmartClient modules Opcenter QL Home (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Audit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Cockpit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions \u003e= V13.2 \u003c V2506), SOA Audit (All versions \u003e= V13.2 \u003c V2506), SOA Cockpit (All versions \u003e= V13.2 \u003c V2506). The affected application do not encrypt the communication in LDAP interface by default. This could allow an authenticated attacker to gain unauthorized access to sensitive information."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.1,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 2,
"baseSeverity": "LOW",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:H/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-311",
"description": "CWE-311: Missing Encryption of Sensitive Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:16:35.999Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-382999.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-41980",
"datePublished": "2025-08-12T11:16:35.999Z",
"dateReserved": "2024-07-25T12:46:30.322Z",
"dateUpdated": "2025-08-12T15:54:00.509Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-41979 (GCVE-0-2024-41979)
Vulnerability from nvd – Published: 2025-08-12 11:16 – Updated: 2025-08-12 15:54
VLAI?
Summary
A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application does not enforce mandatory authorization on some functionality level at server side. This could allow an authenticated attacker to gain complete access of the application.
Severity ?
CWE
- CWE-863 - Incorrect Authorization
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | SmartClient modules Opcenter QL Home (SC) |
Affected:
V13.2 , < V2506
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-41979",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-12T15:54:24.954678Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T15:54:33.400Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SmartClient modules Opcenter QL Home (SC)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Audit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SOA Cockpit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2506",
"status": "affected",
"version": "V13.2",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions \u003e= V13.2 \u003c V2506), SOA Audit (All versions \u003e= V13.2 \u003c V2506), SOA Cockpit (All versions \u003e= V13.2 \u003c V2506). The affected application does not enforce mandatory authorization on some functionality level at server side. This could allow an authenticated attacker to gain complete access of the application."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863: Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:16:34.660Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-382999.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-41979",
"datePublished": "2025-08-12T11:16:34.660Z",
"dateReserved": "2024-07-25T12:46:30.321Z",
"dateUpdated": "2025-08-12T15:54:33.400Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}