CVE-2017-7966 (GCVE-0-2017-7966)
Vulnerability from cvelistv5 – Published: 2017-06-07 19:00 – Updated: 2024-08-05 16:19
VLAI?
Summary
A DLL Hijacking vulnerability in the programming software in Schneider Electric's SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on the targeted system. The vulnerability exists due to the improper loading of a DLL.
Severity ?
No CVSS data available.
CWE
- DLL Hijacking
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric SE | SoMachine HVAC Programming Software |
Affected:
v2.1.0 for Modicon M171/M172 Controllers
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:19:29.779Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-02/"
},
{
"name": "98446",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/98446"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SoMachine HVAC Programming Software",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "v2.1.0 for Modicon M171/M172 Controllers"
}
]
}
],
"datePublic": "2017-05-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A DLL Hijacking vulnerability in the programming software in Schneider Electric\u0027s SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on the targeted system. The vulnerability exists due to the improper loading of a DLL."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "DLL Hijacking",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-06-08T09:57:01",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-02/"
},
{
"name": "98446",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/98446"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2017-7966",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SoMachine HVAC Programming Software",
"version": {
"version_data": [
{
"version_value": "v2.1.0 for Modicon M171/M172 Controllers"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A DLL Hijacking vulnerability in the programming software in Schneider Electric\u0027s SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on the targeted system. The vulnerability exists due to the improper loading of a DLL."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "DLL Hijacking"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-02/",
"refsource": "CONFIRM",
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-02/"
},
{
"name": "98446",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/98446"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2017-7966",
"datePublished": "2017-06-07T19:00:00",
"dateReserved": "2017-04-19T00:00:00",
"dateUpdated": "2024-08-05T16:19:29.779Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-7965 (GCVE-0-2017-7965)
Vulnerability from cvelistv5 – Published: 2017-06-07 19:00 – Updated: 2024-08-05 16:19
VLAI?
Summary
A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller.
Severity ?
No CVSS data available.
CWE
- Buffer Overflow
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric SE | SoMachine HVAC Programming Software |
Affected:
v2.1.0 for Modicon M171/M172 Controllers
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:19:29.459Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
},
{
"name": "98449",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/98449"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SoMachine HVAC Programming Software",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "v2.1.0 for Modicon M171/M172 Controllers"
}
]
}
],
"datePublic": "2017-05-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric\u0027s SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Buffer Overflow",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-06-08T09:57:01",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
},
{
"name": "98449",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/98449"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2017-7965",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SoMachine HVAC Programming Software",
"version": {
"version_data": [
{
"version_value": "v2.1.0 for Modicon M171/M172 Controllers"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric\u0027s SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/",
"refsource": "CONFIRM",
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
},
{
"name": "98449",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/98449"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2017-7965",
"datePublished": "2017-06-07T19:00:00",
"dateReserved": "2017-04-19T00:00:00",
"dateUpdated": "2024-08-05T16:19:29.459Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-7966 (GCVE-0-2017-7966)
Vulnerability from nvd – Published: 2017-06-07 19:00 – Updated: 2024-08-05 16:19
VLAI?
Summary
A DLL Hijacking vulnerability in the programming software in Schneider Electric's SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on the targeted system. The vulnerability exists due to the improper loading of a DLL.
Severity ?
No CVSS data available.
CWE
- DLL Hijacking
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric SE | SoMachine HVAC Programming Software |
Affected:
v2.1.0 for Modicon M171/M172 Controllers
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:19:29.779Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-02/"
},
{
"name": "98446",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/98446"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SoMachine HVAC Programming Software",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "v2.1.0 for Modicon M171/M172 Controllers"
}
]
}
],
"datePublic": "2017-05-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A DLL Hijacking vulnerability in the programming software in Schneider Electric\u0027s SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on the targeted system. The vulnerability exists due to the improper loading of a DLL."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "DLL Hijacking",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-06-08T09:57:01",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-02/"
},
{
"name": "98446",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/98446"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2017-7966",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SoMachine HVAC Programming Software",
"version": {
"version_data": [
{
"version_value": "v2.1.0 for Modicon M171/M172 Controllers"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A DLL Hijacking vulnerability in the programming software in Schneider Electric\u0027s SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on the targeted system. The vulnerability exists due to the improper loading of a DLL."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "DLL Hijacking"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-02/",
"refsource": "CONFIRM",
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-02/"
},
{
"name": "98446",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/98446"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2017-7966",
"datePublished": "2017-06-07T19:00:00",
"dateReserved": "2017-04-19T00:00:00",
"dateUpdated": "2024-08-05T16:19:29.779Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-7965 (GCVE-0-2017-7965)
Vulnerability from nvd – Published: 2017-06-07 19:00 – Updated: 2024-08-05 16:19
VLAI?
Summary
A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller.
Severity ?
No CVSS data available.
CWE
- Buffer Overflow
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Schneider Electric SE | SoMachine HVAC Programming Software |
Affected:
v2.1.0 for Modicon M171/M172 Controllers
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:19:29.459Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
},
{
"name": "98449",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/98449"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SoMachine HVAC Programming Software",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "v2.1.0 for Modicon M171/M172 Controllers"
}
]
}
],
"datePublic": "2017-05-05T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric\u0027s SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Buffer Overflow",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-06-08T09:57:01",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
},
{
"name": "98449",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/98449"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2017-7965",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SoMachine HVAC Programming Software",
"version": {
"version_data": [
{
"version_value": "v2.1.0 for Modicon M171/M172 Controllers"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric\u0027s SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/",
"refsource": "CONFIRM",
"url": "http://www.schneider-electric.com/en/download/document/SEVD-2017-125-01/"
},
{
"name": "98449",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/98449"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2017-7965",
"datePublished": "2017-06-07T19:00:00",
"dateReserved": "2017-04-19T00:00:00",
"dateUpdated": "2024-08-05T16:19:29.459Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}