Vulnerabilites related to Siemens - Teamcenter Visualization V2412
cve-2025-23402
Vulnerability from cvelistv5
Published
2025-03-11 09:48
Modified
2025-03-11 14:29
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process.
Show details on NVD website


{
   containers: {
      adp: [
         {
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2025-23402",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2025-03-11T14:28:48.184791Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2025-03-11T14:29:22.710Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V14.3",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V14.3.0.13",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2312",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2312.0009",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2406",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2406.0007",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2412",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2412.0002",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Tecnomatix Plant Simulation V2302",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2302.0021",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Tecnomatix Plant Simulation V2404",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2404.0010",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files.\r\nAn attacker could leverage this vulnerability to execute code in the context of the current process.",
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  baseScore: 7.8,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
            },
            {
               cvssV4_0: {
                  baseScore: 7.3,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                  version: "4.0",
               },
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-416",
                     description: "CWE-416: Use After Free",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2025-03-11T09:48:18.241Z",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               url: "https://cert-portal.siemens.com/productcert/html/ssa-050438.html",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2025-23402",
      datePublished: "2025-03-11T09:48:18.241Z",
      dateReserved: "2025-01-15T14:20:46.047Z",
      dateUpdated: "2025-03-11T14:29:22.710Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2025-23400
Vulnerability from cvelistv5
Published
2025-03-11 09:48
Modified
2025-03-11 14:59
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
   containers: {
      adp: [
         {
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2025-23400",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2025-03-11T14:57:36.559116Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2025-03-11T14:59:33.908Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V14.3",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V14.3.0.13",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2312",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2312.0009",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2406",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2406.0007",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2412",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2412.0002",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Tecnomatix Plant Simulation V2302",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2302.0021",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Tecnomatix Plant Simulation V2404",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2404.0010",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.",
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  baseScore: 7.8,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
            },
            {
               cvssV4_0: {
                  baseScore: 7.3,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                  version: "4.0",
               },
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-119",
                     description: "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2025-03-11T09:48:15.383Z",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               url: "https://cert-portal.siemens.com/productcert/html/ssa-050438.html",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2025-23400",
      datePublished: "2025-03-11T09:48:15.383Z",
      dateReserved: "2025-01-15T14:20:46.047Z",
      dateUpdated: "2025-03-11T14:59:33.908Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2025-23398
Vulnerability from cvelistv5
Published
2025-03-11 09:48
Modified
2025-03-11 13:45
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
   containers: {
      adp: [
         {
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2025-23398",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2025-03-11T13:45:05.413293Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2025-03-11T13:45:43.215Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V14.3",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V14.3.0.13",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2312",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2312.0009",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2406",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2406.0007",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2412",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2412.0002",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Tecnomatix Plant Simulation V2302",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2302.0021",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Tecnomatix Plant Simulation V2404",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2404.0010",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.",
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  baseScore: 7.8,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
            },
            {
               cvssV4_0: {
                  baseScore: 7.3,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                  version: "4.0",
               },
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-119",
                     description: "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2025-03-11T09:48:12.525Z",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               url: "https://cert-portal.siemens.com/productcert/html/ssa-050438.html",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2025-23398",
      datePublished: "2025-03-11T09:48:12.525Z",
      dateReserved: "2025-01-15T14:20:46.047Z",
      dateUpdated: "2025-03-11T13:45:43.215Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2025-23396
Vulnerability from cvelistv5
Published
2025-03-11 09:48
Modified
2025-03-11 13:49
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
   containers: {
      adp: [
         {
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2025-23396",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2025-03-11T13:49:04.408654Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2025-03-11T13:49:18.776Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V14.3",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V14.3.0.13",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2312",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2312.0009",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2406",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2406.0007",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2412",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2412.0002",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Tecnomatix Plant Simulation V2302",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2302.0021",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Tecnomatix Plant Simulation V2404",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2404.0010",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file.\r\nThis could allow an attacker to execute code in the context of the current process.",
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  baseScore: 7.8,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
            },
            {
               cvssV4_0: {
                  baseScore: 7.3,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                  version: "4.0",
               },
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-787",
                     description: "CWE-787: Out-of-bounds Write",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2025-03-11T09:48:09.716Z",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               url: "https://cert-portal.siemens.com/productcert/html/ssa-050438.html",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2025-23396",
      datePublished: "2025-03-11T09:48:09.716Z",
      dateReserved: "2025-01-15T14:20:46.046Z",
      dateUpdated: "2025-03-11T13:49:18.776Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2025-23397
Vulnerability from cvelistv5
Published
2025-03-11 09:48
Modified
2025-03-11 13:48
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
   containers: {
      adp: [
         {
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2025-23397",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2025-03-11T13:47:07.609257Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2025-03-11T13:48:23.588Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V14.3",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V14.3.0.13",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2312",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2312.0009",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2406",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2406.0007",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2412",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2412.0002",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Tecnomatix Plant Simulation V2302",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2302.0021",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Tecnomatix Plant Simulation V2404",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2404.0010",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.",
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  baseScore: 7.8,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
            },
            {
               cvssV4_0: {
                  baseScore: 7.3,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                  version: "4.0",
               },
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-119",
                     description: "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2025-03-11T09:48:11.135Z",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               url: "https://cert-portal.siemens.com/productcert/html/ssa-050438.html",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2025-23397",
      datePublished: "2025-03-11T09:48:11.135Z",
      dateReserved: "2025-01-15T14:20:46.046Z",
      dateUpdated: "2025-03-11T13:48:23.588Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2025-23399
Vulnerability from cvelistv5
Published
2025-03-11 09:48
Modified
2025-03-11 15:05
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
   containers: {
      adp: [
         {
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2025-23399",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2025-03-11T15:02:55.935480Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2025-03-11T15:05:09.830Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V14.3",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V14.3.0.13",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2312",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2312.0009",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2406",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2406.0007",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2412",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2412.0002",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Tecnomatix Plant Simulation V2302",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2302.0021",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Tecnomatix Plant Simulation V2404",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2404.0010",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process.",
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  baseScore: 7.8,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
            },
            {
               cvssV4_0: {
                  baseScore: 7.3,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                  version: "4.0",
               },
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-125",
                     description: "CWE-125: Out-of-bounds Read",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2025-03-11T09:48:13.954Z",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               url: "https://cert-portal.siemens.com/productcert/html/ssa-050438.html",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2025-23399",
      datePublished: "2025-03-11T09:48:13.954Z",
      dateReserved: "2025-01-15T14:20:46.047Z",
      dateUpdated: "2025-03-11T15:05:09.830Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2025-23401
Vulnerability from cvelistv5
Published
2025-03-11 09:48
Modified
2025-03-11 14:31
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
   containers: {
      adp: [
         {
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2025-23401",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2025-03-11T14:30:32.123564Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2025-03-11T14:31:03.615Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V14.3",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V14.3.0.13",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2312",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2312.0009",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2406",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2406.0007",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2412",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2412.0002",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Tecnomatix Plant Simulation V2302",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2302.0021",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Tecnomatix Plant Simulation V2404",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2404.0010",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process.",
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  baseScore: 7.8,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
            },
            {
               cvssV4_0: {
                  baseScore: 7.3,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                  version: "4.0",
               },
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-125",
                     description: "CWE-125: Out-of-bounds Read",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2025-03-11T09:48:16.806Z",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               url: "https://cert-portal.siemens.com/productcert/html/ssa-050438.html",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2025-23401",
      datePublished: "2025-03-11T09:48:16.806Z",
      dateReserved: "2025-01-15T14:20:46.047Z",
      dateUpdated: "2025-03-11T14:31:03.615Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}

cve-2025-27438
Vulnerability from cvelistv5
Published
2025-03-11 09:48
Modified
2025-03-11 13:26
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
Show details on NVD website


{
   containers: {
      adp: [
         {
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2025-27438",
                        options: [
                           {
                              Exploitation: "none",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "total",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2025-03-11T13:26:38.797340Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2025-03-11T13:26:49.545Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V14.3",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V14.3.0.13",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2312",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2312.0009",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2406",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2406.0007",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Teamcenter Visualization V2412",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2412.0002",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Tecnomatix Plant Simulation V2302",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2302.0021",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
            {
               defaultStatus: "unknown",
               product: "Tecnomatix Plant Simulation V2404",
               vendor: "Siemens",
               versions: [
                  {
                     lessThan: "V2404.0010",
                     status: "affected",
                     version: "0",
                     versionType: "custom",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process.",
            },
         ],
         metrics: [
            {
               cvssV3_1: {
                  baseScore: 7.8,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                  version: "3.1",
               },
            },
            {
               cvssV4_0: {
                  baseScore: 7.3,
                  baseSeverity: "HIGH",
                  vectorString: "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                  version: "4.0",
               },
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     cweId: "CWE-125",
                     description: "CWE-125: Out-of-bounds Read",
                     lang: "en",
                     type: "CWE",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2025-03-11T09:48:31.489Z",
            orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            shortName: "siemens",
         },
         references: [
            {
               url: "https://cert-portal.siemens.com/productcert/html/ssa-050438.html",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
      assignerShortName: "siemens",
      cveId: "CVE-2025-27438",
      datePublished: "2025-03-11T09:48:31.489Z",
      dateReserved: "2025-02-25T16:39:12.235Z",
      dateUpdated: "2025-03-11T13:26:49.545Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
}