7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
7.3 (High) - CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
EPSS score ?
Summary
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process.
References
Impacted products
Vendor | Product | Version | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
▼ | Siemens | Teamcenter Visualization V14.3 |
Version: 0 < V14.3.0.13 |
||||||||||||||||||||||||||
|
{ containers: { adp: [ { metrics: [ { other: { content: { id: "CVE-2025-23399", options: [ { Exploitation: "none", }, { Automatable: "no", }, { "Technical Impact": "total", }, ], role: "CISA Coordinator", timestamp: "2025-03-11T15:02:55.935480Z", version: "2.0.3", }, type: "ssvc", }, }, ], providerMetadata: { dateUpdated: "2025-03-11T15:05:09.830Z", orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0", shortName: "CISA-ADP", }, title: "CISA ADP Vulnrichment", }, ], cna: { affected: [ { defaultStatus: "unknown", product: "Teamcenter Visualization V14.3", vendor: "Siemens", versions: [ { lessThan: "V14.3.0.13", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "Teamcenter Visualization V2312", vendor: "Siemens", versions: [ { lessThan: "V2312.0009", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "Teamcenter Visualization V2406", vendor: "Siemens", versions: [ { lessThan: "V2406.0007", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "Teamcenter Visualization V2412", vendor: "Siemens", versions: [ { lessThan: "V2412.0002", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "Tecnomatix Plant Simulation V2302", vendor: "Siemens", versions: [ { lessThan: "V2302.0021", status: "affected", version: "0", versionType: "custom", }, ], }, { defaultStatus: "unknown", product: "Tecnomatix Plant Simulation V2404", vendor: "Siemens", versions: [ { lessThan: "V2404.0010", status: "affected", version: "0", versionType: "custom", }, ], }, ], descriptions: [ { lang: "en", value: "A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process.", }, ], metrics: [ { cvssV3_1: { baseScore: 7.8, baseSeverity: "HIGH", vectorString: "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", version: "3.1", }, }, { cvssV4_0: { baseScore: 7.3, baseSeverity: "HIGH", vectorString: "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", version: "4.0", }, }, ], problemTypes: [ { descriptions: [ { cweId: "CWE-125", description: "CWE-125: Out-of-bounds Read", lang: "en", type: "CWE", }, ], }, ], providerMetadata: { dateUpdated: "2025-03-11T09:48:13.954Z", orgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", shortName: "siemens", }, references: [ { url: "https://cert-portal.siemens.com/productcert/html/ssa-050438.html", }, ], }, }, cveMetadata: { assignerOrgId: "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", assignerShortName: "siemens", cveId: "CVE-2025-23399", datePublished: "2025-03-11T09:48:13.954Z", dateReserved: "2025-01-15T14:20:46.047Z", dateUpdated: "2025-03-11T15:05:09.830Z", state: "PUBLISHED", }, dataType: "CVE_RECORD", dataVersion: "5.1", "vulnerability-lookup:meta": { nvd: "{\"cve\":{\"id\":\"CVE-2025-23399\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2025-03-11T10:15:17.170\",\"lastModified\":\"2025-03-11T10:15:17.170\",\"vulnStatus\":\"Received\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\\r\\nThis could allow an attacker to execute code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Teamcenter Visualization V14.3 (todas las versiones < V14.3.0.13), Teamcenter Visualization V2312 (todas las versiones < V2312.0009), Teamcenter Visualization V2406 (todas las versiones < V2406.0007), Teamcenter Visualization V2412 (todas las versiones < V2412.0002), Tecnomatix Plant Simulation V2302 (todas las versiones < V2302.0021), Tecnomatix Plant Simulation V2404 (todas las versiones < V2404.0010). Las aplicaciones afectadas contienen una lectura fuera de los límites más allá del final de una estructura asignada mientras se analizan archivos WRL especialmente manipulados. Esto podría permitir que un atacante ejecute código en el contexto del proceso actual. \"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"HIGH\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"PASSIVE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-125\"}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-050438.html\",\"source\":\"productcert@siemens.com\"}]}}", vulnrichment: { containers: "{\"cna\": {\"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2025-03-11T09:48:13.954Z\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.\\r\\nThis could allow an attacker to execute code in the context of the current process.\"}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"Teamcenter Visualization V14.3\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V14.3.0.13\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Teamcenter Visualization V2312\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2312.0009\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Teamcenter Visualization V2406\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2406.0007\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Teamcenter Visualization V2412\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2412.0002\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Tecnomatix Plant Simulation V2302\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2302.0021\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"Siemens\", \"product\": \"Tecnomatix Plant Simulation V2404\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V2404.0010\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\"}}, {\"cvssV4_0\": {\"version\": \"4.0\", \"vectorString\": \"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\", \"baseScore\": 7.3, \"baseSeverity\": \"HIGH\"}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"cweId\": \"CWE-125\", \"description\": \"CWE-125: Out-of-bounds Read\", \"type\": \"CWE\"}]}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-050438.html\"}]}, \"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-23399\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-03-11T15:02:55.935480Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-03-11T15:05:06.827Z\"}}]}", cveMetadata: "{\"cveId\": \"CVE-2025-23399\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"state\": \"PUBLISHED\", \"assignerShortName\": \"siemens\", \"dateReserved\": \"2025-01-15T14:20:46.047Z\", \"datePublished\": \"2025-03-11T09:48:13.954Z\", \"dateUpdated\": \"2025-03-11T15:05:09.830Z\"}", dataType: "CVE_RECORD", dataVersion: "5.1", }, }, }
Log in or create an account to share your comment.
Security Advisory comment format.
This schema specifies the format of a comment related to a security advisory.
Title of the comment
Description of the comment
Loading…
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.