CVE-2025-11862 (GCVE-0-2025-11862)

Vulnerability from cvelistv5 – Published: 2025-11-11 13:43 – Updated: 2025-11-12 20:03
VLAI?
Summary
A security issue was discovered within Verve Asset Manager allowing unauthorized read-only users to read, update, and delete users via the API.
CWE
  • CWE-863 - Incorrect Authorization
Assigner
Impacted products
Vendor Product Version
Rockwell Automation Verve Asset Manager Affected: 1.33, 1.34, 1.35, 1.36, 1.37, 1.38, 1.39, 1.40, 1.41, 1.41.1, 1.41.2, 1.41.3
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11862",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-12T14:54:41.943666Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-12T20:03:32.814Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Verve Asset Manager",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "1.33,  1.34,  1.35,  1.36,  1.37,  1.38,  1.39,  1.40,  1.41, 1.41.1,  1.41.2,  1.41.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue was discovered within Verve Asset Manager allowing unauthorized read-only users to read, update, and delete users via the API.\u003c/span\u003e"
            }
          ],
          "value": "A security issue was discovered within Verve Asset Manager allowing unauthorized read-only users to read, update, and delete users via the API."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "LOW",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:H/VA:H/SC:N/SI:L/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-863",
              "description": "CWE-863 Incorrect Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-11T13:43:10.584Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1759.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e1.41.4, 1.42\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "1.41.4, 1.42"
        }
      ],
      "source": {
        "advisory": "SD1759",
        "discovery": "INTERNAL"
      },
      "title": "Verve Asset Manager Access Control Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-11862",
    "datePublished": "2025-11-11T13:43:10.584Z",
    "dateReserved": "2025-10-16T14:02:52.210Z",
    "dateUpdated": "2025-11-12T20:03:32.814Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-1449 (GCVE-0-2025-1449)

Vulnerability from cvelistv5 – Published: 2025-03-31 16:00 – Updated: 2025-03-31 18:24
VLAI?
Summary
A vulnerability exists in the Rockwell Automation Verve Asset Manager due to insufficient variable sanitizing. A portion of the administrative web interface for Verve's Legacy Agentless Device Inventory (ADI) capability (deprecated since the 1.36 release) allows users to change a variable with inadequate sanitizing. If exploited, it could allow a threat actor with administrative access to run arbitrary commands in the context of the container running the service.
CWE
  • CWE -1287 Improper Validation of Specified Type of Input
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-1449",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-31T17:53:19.410844Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-31T18:24:38.780Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Verve Asset Manager",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c=1.39"
            }
          ]
        }
      ],
      "datePublic": "2025-03-20T13:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA vulnerability exists in the Rockwell Automation Verve Asset Manager due to insufficient variable sanitizing. A portion of the administrative web interface for Verve\u0027s Legacy Agentless Device Inventory (ADI) capability (deprecated since the 1.36 release) allows users to change a variable with inadequate sanitizing. If exploited, it could allow a threat actor with administrative access to run arbitrary commands in the context of the container running the service. \u003c/span\u003e"
            }
          ],
          "value": "A vulnerability exists in the Rockwell Automation Verve Asset Manager due to insufficient variable sanitizing. A portion of the administrative web interface for Verve\u0027s Legacy Agentless Device Inventory (ADI) capability (deprecated since the 1.36 release) allows users to change a variable with inadequate sanitizing. If exploited, it could allow a threat actor with administrative access to run arbitrary commands in the context of the container running the service."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE -1287 Improper Validation of Specified Type of Input",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-31T16:00:56.951Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1723.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eAffected Product\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eAffected Version(s)\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCorrected in Software Revision \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eVerve Asset Manager \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026lt;=1.39\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV1.40\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Affected Product\u00a0\n\n\u00a0\n\n\u00a0\n\nAffected Version(s)\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCorrected in Software Revision \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nVerve Asset Manager \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u003c=1.39\n\n\u00a0\n\n\u00a0\n\nV1.40"
        }
      ],
      "source": {
        "advisory": "SD1723",
        "discovery": "INTERNAL"
      },
      "title": "Admin Shell Access Vulnerability in Rockwell Automation Verve Asset Manager",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-1449",
    "datePublished": "2025-03-31T16:00:56.951Z",
    "dateReserved": "2025-02-18T16:22:18.886Z",
    "dateUpdated": "2025-03-31T18:24:38.780Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-11862 (GCVE-0-2025-11862)

Vulnerability from nvd – Published: 2025-11-11 13:43 – Updated: 2025-11-12 20:03
VLAI?
Summary
A security issue was discovered within Verve Asset Manager allowing unauthorized read-only users to read, update, and delete users via the API.
CWE
  • CWE-863 - Incorrect Authorization
Assigner
Impacted products
Vendor Product Version
Rockwell Automation Verve Asset Manager Affected: 1.33, 1.34, 1.35, 1.36, 1.37, 1.38, 1.39, 1.40, 1.41, 1.41.1, 1.41.2, 1.41.3
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11862",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-12T14:54:41.943666Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-12T20:03:32.814Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Verve Asset Manager",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "1.33,  1.34,  1.35,  1.36,  1.37,  1.38,  1.39,  1.40,  1.41, 1.41.1,  1.41.2,  1.41.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue was discovered within Verve Asset Manager allowing unauthorized read-only users to read, update, and delete users via the API.\u003c/span\u003e"
            }
          ],
          "value": "A security issue was discovered within Verve Asset Manager allowing unauthorized read-only users to read, update, and delete users via the API."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "LOW",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:H/VA:H/SC:N/SI:L/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-863",
              "description": "CWE-863 Incorrect Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-11T13:43:10.584Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1759.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e1.41.4, 1.42\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "1.41.4, 1.42"
        }
      ],
      "source": {
        "advisory": "SD1759",
        "discovery": "INTERNAL"
      },
      "title": "Verve Asset Manager Access Control Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-11862",
    "datePublished": "2025-11-11T13:43:10.584Z",
    "dateReserved": "2025-10-16T14:02:52.210Z",
    "dateUpdated": "2025-11-12T20:03:32.814Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-1449 (GCVE-0-2025-1449)

Vulnerability from nvd – Published: 2025-03-31 16:00 – Updated: 2025-03-31 18:24
VLAI?
Summary
A vulnerability exists in the Rockwell Automation Verve Asset Manager due to insufficient variable sanitizing. A portion of the administrative web interface for Verve's Legacy Agentless Device Inventory (ADI) capability (deprecated since the 1.36 release) allows users to change a variable with inadequate sanitizing. If exploited, it could allow a threat actor with administrative access to run arbitrary commands in the context of the container running the service.
CWE
  • CWE -1287 Improper Validation of Specified Type of Input
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-1449",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-31T17:53:19.410844Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-31T18:24:38.780Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Verve Asset Manager",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c=1.39"
            }
          ]
        }
      ],
      "datePublic": "2025-03-20T13:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA vulnerability exists in the Rockwell Automation Verve Asset Manager due to insufficient variable sanitizing. A portion of the administrative web interface for Verve\u0027s Legacy Agentless Device Inventory (ADI) capability (deprecated since the 1.36 release) allows users to change a variable with inadequate sanitizing. If exploited, it could allow a threat actor with administrative access to run arbitrary commands in the context of the container running the service. \u003c/span\u003e"
            }
          ],
          "value": "A vulnerability exists in the Rockwell Automation Verve Asset Manager due to insufficient variable sanitizing. A portion of the administrative web interface for Verve\u0027s Legacy Agentless Device Inventory (ADI) capability (deprecated since the 1.36 release) allows users to change a variable with inadequate sanitizing. If exploited, it could allow a threat actor with administrative access to run arbitrary commands in the context of the container running the service."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE -1287 Improper Validation of Specified Type of Input",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-03-31T16:00:56.951Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1723.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eAffected Product\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eAffected Version(s)\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eCorrected in Software Revision \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003eVerve Asset Manager \u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026lt;=1.39\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV1.40\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Affected Product\u00a0\n\n\u00a0\n\n\u00a0\n\nAffected Version(s)\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nCorrected in Software Revision \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\nVerve Asset Manager \n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u00a0\n\n\u003c=1.39\n\n\u00a0\n\n\u00a0\n\nV1.40"
        }
      ],
      "source": {
        "advisory": "SD1723",
        "discovery": "INTERNAL"
      },
      "title": "Admin Shell Access Vulnerability in Rockwell Automation Verve Asset Manager",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-1449",
    "datePublished": "2025-03-31T16:00:56.951Z",
    "dateReserved": "2025-02-18T16:22:18.886Z",
    "dateUpdated": "2025-03-31T18:24:38.780Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}