Search criteria
4 vulnerabilities found for Virtual Appliance (vApp) Manager by Dell
CVE-2024-25955 (GCVE-0-2024-25955)
Vulnerability from cvelistv5 – Published: 2024-03-28 19:05 – Updated: 2024-08-01 23:52
VLAI?
Summary
Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Virtual Appliance (vApp) Manager |
Affected:
N/A , < 9.2.4.9
(semver)
Affected: N/A , < 9.2.4.6 (semver) Affected: N/A , < 5978 (semver) |
Credits
Dell Technologies would like to thank 33a6099 for reporting these issues.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:dell:unisphere_for_powermax_virtual_appliance:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unisphere_for_powermax_virtual_appliance",
"vendor": "dell",
"versions": [
{
"lessThan": "9.2.4.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:dell:solutions_enabler_virtual_appliance:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "solutions_enabler_virtual_appliance",
"vendor": "dell",
"versions": [
{
"lessThan": "9.2.4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:dell:unisphere_for_powermax:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unisphere_for_powermax",
"vendor": "dell",
"versions": [
{
"lessThan": "5978",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-25955",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-08T17:44:26.390852Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-20T18:39:13.355Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T23:52:06.240Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Virtual Appliance (vApp) Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.2.4.9",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "9.2.4.6",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "5978",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell Technologies would like to thank 33a6099 for reporting these issues. "
}
],
"datePublic": "2024-03-28T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity."
}
],
"value": "Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-28T19:05:10.021Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-25955",
"datePublished": "2024-03-28T19:05:10.021Z",
"dateReserved": "2024-02-13T05:32:19.480Z",
"dateUpdated": "2024-08-01T23:52:06.240Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-25946 (GCVE-0-2024-25946)
Vulnerability from cvelistv5 – Published: 2024-03-28 19:00 – Updated: 2025-03-25 14:43
VLAI?
Summary
Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Virtual Appliance (vApp) Manager |
Affected:
N/A , < 9.2.4.9
(semver)
Affected: N/A , < 9.2.4.6 (semver) Affected: N/A , < 5978 (semver) |
Credits
Dell Technologies would like to thank 33a6099 for reporting these issues
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:dell:virtual_appliance_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "virtual_appliance_manager",
"vendor": "dell",
"versions": [
{
"lessThan": "9.2.4.9",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "9.2.4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "5978",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-25946",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-28T19:38:49.231622Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T14:43:03.457Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T23:52:06.416Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Virtual Appliance (vApp) Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.2.4.9",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "9.2.4.6",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "5978",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell Technologies would like to thank 33a6099 for reporting these issues"
}
],
"datePublic": "2024-03-28T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity."
}
],
"value": "Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-28T19:00:18.175Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-25946",
"datePublished": "2024-03-28T19:00:18.175Z",
"dateReserved": "2024-02-13T05:29:58.481Z",
"dateUpdated": "2025-03-25T14:43:03.457Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-25955 (GCVE-0-2024-25955)
Vulnerability from nvd – Published: 2024-03-28 19:05 – Updated: 2024-08-01 23:52
VLAI?
Summary
Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Virtual Appliance (vApp) Manager |
Affected:
N/A , < 9.2.4.9
(semver)
Affected: N/A , < 9.2.4.6 (semver) Affected: N/A , < 5978 (semver) |
Credits
Dell Technologies would like to thank 33a6099 for reporting these issues.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:dell:unisphere_for_powermax_virtual_appliance:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unisphere_for_powermax_virtual_appliance",
"vendor": "dell",
"versions": [
{
"lessThan": "9.2.4.9",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:dell:solutions_enabler_virtual_appliance:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "solutions_enabler_virtual_appliance",
"vendor": "dell",
"versions": [
{
"lessThan": "9.2.4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:dell:unisphere_for_powermax:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "unisphere_for_powermax",
"vendor": "dell",
"versions": [
{
"lessThan": "5978",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-25955",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-08T17:44:26.390852Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-20T18:39:13.355Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T23:52:06.240Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Virtual Appliance (vApp) Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.2.4.9",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "9.2.4.6",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "5978",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell Technologies would like to thank 33a6099 for reporting these issues. "
}
],
"datePublic": "2024-03-28T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity."
}
],
"value": "Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-28T19:05:10.021Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-25955",
"datePublished": "2024-03-28T19:05:10.021Z",
"dateReserved": "2024-02-13T05:32:19.480Z",
"dateUpdated": "2024-08-01T23:52:06.240Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-25946 (GCVE-0-2024-25946)
Vulnerability from nvd – Published: 2024-03-28 19:00 – Updated: 2025-03-25 14:43
VLAI?
Summary
Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity.
Severity ?
7.2 (High)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Virtual Appliance (vApp) Manager |
Affected:
N/A , < 9.2.4.9
(semver)
Affected: N/A , < 9.2.4.6 (semver) Affected: N/A , < 5978 (semver) |
Credits
Dell Technologies would like to thank 33a6099 for reporting these issues
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:dell:virtual_appliance_manager:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "virtual_appliance_manager",
"vendor": "dell",
"versions": [
{
"lessThan": "9.2.4.9",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "9.2.4.6",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"lessThan": "5978",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-25946",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-03-28T19:38:49.231622Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-25T14:43:03.457Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T23:52:06.416Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Virtual Appliance (vApp) Manager",
"vendor": "Dell",
"versions": [
{
"lessThan": "9.2.4.9",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "9.2.4.6",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "5978",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell Technologies would like to thank 33a6099 for reporting these issues"
}
],
"datePublic": "2024-03-28T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity."
}
],
"value": "Dell vApp Manager, versions prior to 9.2.4.9 contain a Command Injection Vulnerability. An authorized attacker could potentially exploit this vulnerability leading to an execution of an inserted command. Dell recommends customers to upgrade at the earliest opportunity."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-03-28T19:00:18.175Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000223609/dsa-2024-108-dell-powermaxos-5978-dell-powermax-os-10-0-1-5-dell-powermax-os-10-1-0-2-dell-unisphere-360-unisphere-powermax-unisphere-powermax-vapp-dell-solutions-enabler-vapp-and-dell-powermax-eem-security-update-for-multiple-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-25946",
"datePublished": "2024-03-28T19:00:18.175Z",
"dateReserved": "2024-02-13T05:29:58.481Z",
"dateUpdated": "2025-03-25T14:43:03.457Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}