All the vulnerabilites related to GE HealthCare - Vivid iq
cve-2024-1629
Vulnerability from cvelistv5
Published
2024-05-14 16:32
Modified
2024-08-01 18:48
Severity ?
EPSS score ?
Summary
Path traversal vulnerability in “deleteFiles” function of Common Service Desktop, a GE HealthCare ultrasound device component
References
Impacted products
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-1629", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-05-16T16:09:37.900864Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T18:01:09.761Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T18:48:21.479Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://securityupdate.gehealthcare.com/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Venue", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "R1" }, { "status": "affected", "version": "R2" }, { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.3", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Venue Go", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "R2" }, { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.3", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Venue Fit", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.3", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ e", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "R9.1.4", "status": "affected", "version": "R7", "versionType": "custom" }, { "lessThanOrEqual": "R10.1.3", "status": "affected", "version": "R8", "versionType": "custom" }, { "lessThanOrEqual": "R11.0.3", "status": "affected", "version": "R9", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ He", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "R9.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid E", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "E95", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "E90", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "E80", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid S", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "70N", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "60N", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid T", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "T8", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "T9", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid iq", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Voluson Expert 16", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "0" }, { "status": "affected", "version": "BT24" } ] }, { "defaultStatus": "unaffected", "product": "Voluson Expert 18", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "0" }, { "status": "affected", "version": "BT24" } ] }, { "defaultStatus": "unaffected", "product": "Voluson Expert 22", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "0" }, { "status": "affected", "version": "BT24" } ] }, { "defaultStatus": "unaffected", "product": "Voluson SWIFT", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "0" }, { "status": "affected", "version": "BT24" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ E10", "vendor": "GE HealthCare", "versions": [ { "lessThan": "R3.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ E10s", "vendor": "GE HealthCare", "versions": [ { "lessThan": "R3.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ Fortis", "vendor": "GE HealthCare", "versions": [ { "lessThan": "R3.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Path traversal vulnerability in \u201cdeleteFiles\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component" } ], "value": "Path traversal vulnerability in \u201cdeleteFiles\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component" } ], "impacts": [ { "capecId": "CAPEC-126", "descriptions": [ { "lang": "en", "value": "CAPEC-126 Path Traversal" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 6.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-14T16:32:43.530Z", "orgId": "171caf72-b841-4e04-a68e-93493aff2b94", "shortName": "GEHC" }, "references": [ { "url": "https://securityupdate.gehealthcare.com/" } ], "source": { "discovery": "EXTERNAL" }, "title": "Path traversal vulnerability in \u201cdeleteFiles\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "171caf72-b841-4e04-a68e-93493aff2b94", "assignerShortName": "GEHC", "cveId": "CVE-2024-1629", "datePublished": "2024-05-14T16:32:43.530Z", "dateReserved": "2024-02-19T15:23:21.436Z", "dateUpdated": "2024-08-01T18:48:21.479Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-1628
Vulnerability from cvelistv5
Published
2024-05-14 16:04
Modified
2024-08-01 18:48
Severity ?
EPSS score ?
Summary
OS command injection vulnerabilities in GE HealthCare ultrasound devices
References
Impacted products
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:ge_healthcare:venue:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "venue", "vendor": "ge_healthcare", "versions": [ { "status": "affected", "version": "multiple versions" } ] }, { "cpes": [ "cpe:2.3:a:ge_healthcare:vivid:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "vivid", "vendor": "ge_healthcare", "versions": [ { "status": "affected", "version": "multiple versions" } ] }, { "cpes": [ "cpe:2.3:a:ge_healthcare:voluson:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "voluson", "vendor": "ge_healthcare", "versions": [ { "status": "affected", "version": "multiple versions" } ] }, { "cpes": [ "cpe:2.3:a:ge_healthcare:logiq:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "logiq", "vendor": "ge_healthcare", "versions": [ { "status": "affected", "version": "multiple versions" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-1628", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-05-16T16:10:00.517201Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T18:01:30.939Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T18:48:21.580Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://securityupdate.gehealthcare.com/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Venue", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "R1" }, { "status": "affected", "version": "R2" }, { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.3", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Venue Go", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "R2" }, { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.3", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Venue Fit", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.3", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ e", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "R9.1.4", "status": "affected", "version": "R7", "versionType": "custom" }, { "lessThanOrEqual": "R10.1.3", "status": "affected", "version": "R8", "versionType": "custom" }, { "lessThanOrEqual": "R11.0.3", "status": "affected", "version": "R9", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ He", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "R9.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid E", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "E95", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "E90", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "E80", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid S", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "70N", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "60N", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid T", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "T8", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "T9", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid iq", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Voluson Expert 16", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "0" }, { "lessThan": "Ext1", "status": "affected", "version": "BT24", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Voluson Expert 18", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "0" }, { "lessThan": "Ext1", "status": "affected", "version": "BT24", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Voluson Expert 22", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "0" }, { "lessThan": "Ext1", "status": "affected", "version": "BT24", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Voluson SWIFT", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "0" }, { "status": "affected", "version": "BT24" } ] }, { "defaultStatus": "unaffected", "product": "Invenia ABUS 2.0", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "2.2.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ E10", "vendor": "GE HealthCare", "versions": [ { "lessThan": "R3.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ E10s", "vendor": "GE HealthCare", "versions": [ { "lessThan": "R3.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ Fortis", "vendor": "GE HealthCare", "versions": [ { "lessThan": "R3.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "OS command injection vulnerabilities in GE HealthCare ultrasound devices" } ], "value": "OS command injection vulnerabilities in GE HealthCare ultrasound devices" } ], "impacts": [ { "capecId": "CAPEC-6", "descriptions": [ { "lang": "en", "value": "CAPEC-6 Argument Injection" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-14T16:04:57.780Z", "orgId": "171caf72-b841-4e04-a68e-93493aff2b94", "shortName": "GEHC" }, "references": [ { "url": "https://securityupdate.gehealthcare.com/" } ], "source": { "discovery": "EXTERNAL" }, "title": "OS command injection vulnerabilities in GE HealthCare ultrasound devices", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "171caf72-b841-4e04-a68e-93493aff2b94", "assignerShortName": "GEHC", "cveId": "CVE-2024-1628", "datePublished": "2024-05-14T16:04:57.780Z", "dateReserved": "2024-02-19T15:23:20.113Z", "dateUpdated": "2024-08-01T18:48:21.580Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-1630
Vulnerability from cvelistv5
Published
2024-05-14 16:55
Modified
2024-08-22 17:51
Severity ?
EPSS score ?
Summary
Path traversal vulnerability in “getAllFolderContents” function of Common Service Desktop, a GE HealthCare ultrasound device component
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T18:48:21.818Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://securityupdate.gehealthcare.com/" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:gehealthcare:venue_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "venue_firmware", "vendor": "gehealthcare", "versions": [ { "status": "affected", "version": "r1" }, { "status": "affected", "version": "r2" }, { "lessThanOrEqual": "r3.3", "status": "affected", "version": "r3", "versionType": "custom" }, { "lessThanOrEqual": "r4.3", "status": "affected", "version": "r4", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:venue_go_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "venue_go_firmware", "vendor": "gehealthcare", "versions": [ { "status": "affected", "version": "r2" }, { "lessThanOrEqual": "r3.3", "status": "affected", "version": "r3", "versionType": "custom" }, { "lessThanOrEqual": "r4.3", "status": "affected", "version": "r4", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:venue_fit_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "venue_fit_firmware", "vendor": "gehealthcare", "versions": [ { "lessThanOrEqual": "r3.3", "status": "affected", "version": "r3", "versionType": "custom" }, { "lessThanOrEqual": "r4.3", "status": "affected", "version": "r4", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:logiq_e_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "logiq_e_firmware", "vendor": "gehealthcare", "versions": [ { "lessThanOrEqual": "r9.1.4", "status": "affected", "version": "r7", "versionType": "custom" }, { "lessThanOrEqual": "r10.1.3", "status": "affected", "version": "r8", "versionType": "custom" }, { "lessThanOrEqual": "r11.0.3", "status": "affected", "version": "r9", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:logiq_he_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "logiq_he_firmware", "vendor": "gehealthcare", "versions": [ { "lessThanOrEqual": "r9.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:vivid_e_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "vivid_e_firmware", "vendor": "gehealthcare", "versions": [ { "lessThan": "206", "status": "affected", "version": "e95", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "e90", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "e80", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:vivid_t_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "vivid_t_firmware", "vendor": "gehealthcare", "versions": [ { "lessThan": "206", "status": "affected", "version": "t8", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "t9", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:vivid_iq_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "vivid_iq_firmware", "vendor": "gehealthcare", "versions": [ { "lessThan": "206", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:gehealthcare:voluson_expert_16:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "voluson_expert_16", "vendor": "gehealthcare", "versions": [ { "status": "affected", "version": "0" }, { "status": "affected", "version": "bt24" } ] }, { "cpes": [ "cpe:2.3:a:gehealthcare:voluson_expert_18:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "voluson_expert_18", "vendor": "gehealthcare", "versions": [ { "status": "affected", "version": "0" }, { "status": "affected", "version": "bt24" } ] }, { "cpes": [ "cpe:2.3:a:gehealthcare:voluson_expert_22:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "voluson_expert_22", "vendor": "gehealthcare", "versions": [ { "status": "affected", "version": "0" }, { "status": "affected", "version": "bt24" } ] }, { "cpes": [ "cpe:2.3:a:gehealthcare:voluson_swift:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "voluson_swift", "vendor": "gehealthcare", "versions": [ { "status": "affected", "version": "0" }, { "status": "affected", "version": "bt24" } ] }, { "cpes": [ "cpe:2.3:a:gehealthcare:logiq_e10:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "logiq_e10", "vendor": "gehealthcare", "versions": [ { "lessThan": "r3.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:gehealthcare:logiq_e10s:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "logiq_e10s", "vendor": "gehealthcare", "versions": [ { "lessThan": "r3.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:a:gehealthcare:logiq_fortis:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "logiq_fortis", "vendor": "gehealthcare", "versions": [ { "lessThan": "r3.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-1630", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-05-14T19:43:01.721848Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-22T17:51:14.776Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Venue", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "R1" }, { "status": "affected", "version": "R2" }, { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.3", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Venue Go", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "R2" }, { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.3", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Venue Fit", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.3", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ e", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "R9.1.4", "status": "affected", "version": "R7", "versionType": "custom" }, { "lessThanOrEqual": "R10.1.3", "status": "affected", "version": "R8", "versionType": "custom" }, { "lessThanOrEqual": "R11.0.3", "status": "affected", "version": "R9", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ He", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "R9.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid E", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "E95", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "E90", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "E80", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid T", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "T8", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "T9", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid iq", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Voluson Expert 16", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "0" }, { "status": "affected", "version": "BT24" } ] }, { "defaultStatus": "unaffected", "product": "Voluson Expert 18", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "0" }, { "status": "affected", "version": "BT24" } ] }, { "defaultStatus": "unaffected", "product": "Voluson Expert 22", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "0" }, { "status": "affected", "version": "BT24" } ] }, { "defaultStatus": "unaffected", "product": "Voluson SWIFT", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "0" }, { "status": "affected", "version": "BT24" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ E10", "vendor": "GE HealthCare", "versions": [ { "lessThan": "R3.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ E10s", "vendor": "GE HealthCare", "versions": [ { "lessThan": "R3.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ Fortis", "vendor": "GE HealthCare", "versions": [ { "lessThan": "R3.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Path traversal vulnerability in \u201cgetAllFolderContents\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component" } ], "value": "Path traversal vulnerability in \u201cgetAllFolderContents\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component" } ], "impacts": [ { "capecId": "CAPEC-126", "descriptions": [ { "lang": "en", "value": "CAPEC-126 Path Traversal" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 7.7, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-22", "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-14T16:55:56.853Z", "orgId": "171caf72-b841-4e04-a68e-93493aff2b94", "shortName": "GEHC" }, "references": [ { "url": "https://securityupdate.gehealthcare.com/" } ], "source": { "discovery": "EXTERNAL" }, "title": "Path traversal vulnerability in \u201cgetAllFolderContents\u201d function of Common Service Desktop, a GE HealthCare ultrasound device component", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "171caf72-b841-4e04-a68e-93493aff2b94", "assignerShortName": "GEHC", "cveId": "CVE-2024-1630", "datePublished": "2024-05-14T16:55:56.853Z", "dateReserved": "2024-02-19T15:28:03.794Z", "dateUpdated": "2024-08-22T17:51:14.776Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-1486
Vulnerability from cvelistv5
Published
2024-05-14 15:10
Modified
2024-08-16 18:15
Severity ?
EPSS score ?
Summary
Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T18:40:21.121Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://securityupdate.gehealthcare.com/" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:gehealthcare:venue_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "venue_firmware", "vendor": "gehealthcare", "versions": [ { "status": "affected", "version": "R1" }, { "status": "affected", "version": "R2" }, { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.2", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:venue_go_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "venue_go_firmware", "vendor": "gehealthcare", "versions": [ { "status": "affected", "version": "R2" }, { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.2", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:venue_fit_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "venue_fit_firmware", "vendor": "gehealthcare", "versions": [ { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.2", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:logiq_e_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "logiq_e_firmware", "vendor": "gehealthcare", "versions": [ { "lessThanOrEqual": "R9.1.4", "status": "affected", "version": "R7", "versionType": "custom" }, { "lessThanOrEqual": "R10.1.3", "status": "affected", "version": "R8", "versionType": "custom" }, { "lessThanOrEqual": "R11.0.2", "status": "affected", "version": "R9", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:logiq_he_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "logiq_he_firmware", "vendor": "gehealthcare", "versions": [ { "lessThanOrEqual": "R9.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:vivid_e_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "vivid_e_firmware", "vendor": "gehealthcare", "versions": [ { "lessThan": "206", "status": "affected", "version": "E95", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "E90", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "E80", "versionType": "custom" }, { "lessThanOrEqual": "113.2", "status": "affected", "version": "E9 113.2", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:vivid_s_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "vivid_s_firmware", "vendor": "gehealthcare", "versions": [ { "lessThan": "206", "status": "affected", "version": "70N", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "60N", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:vivid_t_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "vivid_t_firmware", "vendor": "gehealthcare", "versions": [ { "lessThan": "206", "status": "affected", "version": "T8", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "T9", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:vivid_iq_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "vivid_iq_firmware", "vendor": "gehealthcare", "versions": [ { "lessThan": "206", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:invenia_abus_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "invenia_abus_firmware", "vendor": "gehealthcare", "versions": [ { "status": "affected", "version": "1.2.3" } ] }, { "cpes": [ "cpe:2.3:o:gehealthcare:invenia_abus_2.0_firmware:*:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "invenia_abus_2.0_firmware", "vendor": "gehealthcare", "versions": [ { "lessThan": "2.2.9", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-1486", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-06-12T14:08:59.014421Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-16T18:15:02.675Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Venue", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "R1" }, { "status": "affected", "version": "R2" }, { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.2", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Venue Go", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "R2" }, { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.2", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Venue Fit", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.2", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ e", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "R9.1.4", "status": "affected", "version": "R7", "versionType": "custom" }, { "lessThanOrEqual": "R10.1.3", "status": "affected", "version": "R8", "versionType": "custom" }, { "lessThanOrEqual": "R11.0.2", "status": "affected", "version": "R9", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ He", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "R9.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid E", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "E95", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "E90", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "E80", "versionType": "custom" }, { "lessThanOrEqual": "113.2", "status": "affected", "version": "E9 113.2", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid S", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "70N", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "60N", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid T", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "T8", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "T9", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid iq", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Invenia ABUS", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "1.2.3" } ] }, { "defaultStatus": "unaffected", "product": "Invenia ABUS 2.0", "vendor": "GE HealthCare", "versions": [ { "lessThan": "2.2.9", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices" } ], "value": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices" } ], "impacts": [ { "capecId": "CAPEC-1", "descriptions": [ { "lang": "en", "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-732", "description": "CWE-732 Incorrect Permission Assignment for Critical Resource", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-14T15:10:22.262Z", "orgId": "171caf72-b841-4e04-a68e-93493aff2b94", "shortName": "GEHC" }, "references": [ { "url": "https://securityupdate.gehealthcare.com/" } ], "source": { "discovery": "EXTERNAL" }, "title": "Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "171caf72-b841-4e04-a68e-93493aff2b94", "assignerShortName": "GEHC", "cveId": "CVE-2024-1486", "datePublished": "2024-05-14T15:10:22.262Z", "dateReserved": "2024-02-13T22:34:57.386Z", "dateUpdated": "2024-08-16T18:15:02.675Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }