cve-2024-1628
Vulnerability from cvelistv5
Published
2024-05-14 16:04
Modified
2024-08-01 18:48
Severity ?
EPSS score ?
Summary
OS command injection vulnerabilities in GE HealthCare ultrasound devices
References
Impacted products
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:a:ge_healthcare:venue:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "venue", "vendor": "ge_healthcare", "versions": [ { "status": "affected", "version": "multiple versions" } ] }, { "cpes": [ "cpe:2.3:a:ge_healthcare:vivid:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "vivid", "vendor": "ge_healthcare", "versions": [ { "status": "affected", "version": "multiple versions" } ] }, { "cpes": [ "cpe:2.3:a:ge_healthcare:voluson:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "voluson", "vendor": "ge_healthcare", "versions": [ { "status": "affected", "version": "multiple versions" } ] }, { "cpes": [ "cpe:2.3:a:ge_healthcare:logiq:*:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "logiq", "vendor": "ge_healthcare", "versions": [ { "status": "affected", "version": "multiple versions" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-1628", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-05-16T16:10:00.517201Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T18:01:30.939Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T18:48:21.580Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://securityupdate.gehealthcare.com/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Venue", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "R1" }, { "status": "affected", "version": "R2" }, { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.3", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Venue Go", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "R2" }, { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.3", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Venue Fit", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "R3.3", "status": "affected", "version": "R3", "versionType": "custom" }, { "lessThanOrEqual": "R4.3", "status": "affected", "version": "R4", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ e", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "R9.1.4", "status": "affected", "version": "R7", "versionType": "custom" }, { "lessThanOrEqual": "R10.1.3", "status": "affected", "version": "R8", "versionType": "custom" }, { "lessThanOrEqual": "R11.0.3", "status": "affected", "version": "R9", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ He", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "R9.3.1", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid E", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "E95", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "E90", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "E80", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid S", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "70N", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "60N", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid T", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "T8", "versionType": "custom" }, { "lessThan": "206", "status": "affected", "version": "T9", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Vivid iq", "vendor": "GE HealthCare", "versions": [ { "lessThan": "206", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Voluson Expert 16", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "0" }, { "lessThan": "Ext1", "status": "affected", "version": "BT24", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Voluson Expert 18", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "0" }, { "lessThan": "Ext1", "status": "affected", "version": "BT24", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Voluson Expert 22", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "0" }, { "lessThan": "Ext1", "status": "affected", "version": "BT24", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "Voluson SWIFT", "vendor": "GE HealthCare", "versions": [ { "status": "affected", "version": "0" }, { "status": "affected", "version": "BT24" } ] }, { "defaultStatus": "unaffected", "product": "Invenia ABUS 2.0", "vendor": "GE HealthCare", "versions": [ { "lessThanOrEqual": "2.2.7", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ E10", "vendor": "GE HealthCare", "versions": [ { "lessThan": "R3.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ E10s", "vendor": "GE HealthCare", "versions": [ { "lessThan": "R3.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "defaultStatus": "unaffected", "product": "LOGIQ Fortis", "vendor": "GE HealthCare", "versions": [ { "lessThan": "R3.2.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Andrea Palanca and Gabriele Quagliarella of Nozomi Networks" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "OS command injection vulnerabilities in GE HealthCare ultrasound devices" } ], "value": "OS command injection vulnerabilities in GE HealthCare ultrasound devices" } ], "impacts": [ { "capecId": "CAPEC-6", "descriptions": [ { "lang": "en", "value": "CAPEC-6 Argument Injection" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 8.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-14T16:04:57.780Z", "orgId": "171caf72-b841-4e04-a68e-93493aff2b94", "shortName": "GEHC" }, "references": [ { "url": "https://securityupdate.gehealthcare.com/" } ], "source": { "discovery": "EXTERNAL" }, "title": "OS command injection vulnerabilities in GE HealthCare ultrasound devices", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "171caf72-b841-4e04-a68e-93493aff2b94", "assignerShortName": "GEHC", "cveId": "CVE-2024-1628", "datePublished": "2024-05-14T16:04:57.780Z", "dateReserved": "2024-02-19T15:23:20.113Z", "dateUpdated": "2024-08-01T18:48:21.580Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-1628\",\"sourceIdentifier\":\"171caf72-b841-4e04-a68e-93493aff2b94\",\"published\":\"2024-05-14T16:16:00.470\",\"lastModified\":\"2024-05-14T19:18:31.490\",\"vulnStatus\":\"Awaiting Analysis\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"OS command injection vulnerabilities in GE HealthCare ultrasound devices\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidades de inyecci\u00f3n de comandos del sistema operativo en dispositivos de ultrasonido GE HealthCare\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"171caf72-b841-4e04-a68e-93493aff2b94\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.4,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.5,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"171caf72-b841-4e04-a68e-93493aff2b94\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"references\":[{\"url\":\"https://securityupdate.gehealthcare.com/\",\"source\":\"171caf72-b841-4e04-a68e-93493aff2b94\"}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.