var-202312-0479
Vulnerability from variot
Tenda W30E V16.01.0.12(4843) was discovered to contain a command injection vulnerability via the function setUmountUSBPartition. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. An attacker could exploit this vulnerability to cause arbitrary command execution
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202312-0479", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.01.0.12\\(4843\\)" }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "w30e firmware 16.01.0.12(4843)" }, { "model": "w30e", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v16.01.0.12(4843)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98201" }, { "db": "JVNDB", "id": "JVNDB-2023-018795" }, { "db": "NVD", "id": "CVE-2023-49999" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:w30e_firmware:16.01.0.12\\(4843\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-49999" } ] }, "cve": "CVE-2023-49999", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-98201", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-49999", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-49999", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2023-98201", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98201" }, { "db": "JVNDB", "id": "JVNDB-2023-018795" }, { "db": "NVD", "id": "CVE-2023-49999" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E V16.01.0.12(4843) was discovered to contain a command injection vulnerability via the function setUmountUSBPartition. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. An attacker could exploit this vulnerability to cause arbitrary command execution", "sources": [ { "db": "NVD", "id": "CVE-2023-49999" }, { "db": "JVNDB", "id": "JVNDB-2023-018795" }, { "db": "CNVD", "id": "CNVD-2023-98201" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-49999", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2023-018795", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-98201", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98201" }, { "db": "JVNDB", "id": "JVNDB-2023-018795" }, { "db": "NVD", "id": "CVE-2023-49999" } ] }, "id": "VAR-202312-0479", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-98201" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98201" } ] }, "last_update_date": "2024-01-18T22:48:08.234000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018795" }, { "db": "NVD", "id": "CVE-2023-49999" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/gd008/tenda/blob/main/w30e/tenda_w30e_setumountusbpartition/w30e_setumountusbpartition.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-49999" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98201" }, { "db": "JVNDB", "id": "JVNDB-2023-018795" }, { "db": "NVD", "id": "CVE-2023-49999" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-98201" }, { "db": "JVNDB", "id": "JVNDB-2023-018795" }, { "db": "NVD", "id": "CVE-2023-49999" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-15T00:00:00", "db": "CNVD", "id": "CNVD-2023-98201" }, { "date": "2024-01-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-018795" }, { "date": "2023-12-07T17:15:07.373000", "db": "NVD", "id": "CVE-2023-49999" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-18T00:00:00", "db": "CNVD", "id": "CNVD-2023-98201" }, { "date": "2024-01-12T01:18:00", "db": "JVNDB", "id": "JVNDB-2023-018795" }, { "date": "2023-12-09T04:45:07.523000", "db": "NVD", "id": "CVE-2023-49999" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018795" } ], "trust": 0.8 } }
var-202312-0392
Vulnerability from variot
Tenda W30E V16.01.0.12(4843) was discovered to contain a Command Execution vulnerability via the function /goform/telnet. Shenzhen Tenda Technology Co.,Ltd. of w30e There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the failure of the handler function of /goform/telnet to correctly filter special characters, commands, etc. in the constructed command
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202312-0392", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.01.0.12\\(4843\\)" }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "w30e firmware 16.01.0.12(4843)" }, { "model": "w30e", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v16.01.0.12(4843)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98197" }, { "db": "JVNDB", "id": "JVNDB-2023-018801" }, { "db": "NVD", "id": "CVE-2023-49406" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:w30e_firmware:16.01.0.12\\(4843\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-49406" } ] }, "cve": "CVE-2023-49406", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-98197", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-49406", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-49406", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2023-98197", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98197" }, { "db": "JVNDB", "id": "JVNDB-2023-018801" }, { "db": "NVD", "id": "CVE-2023-49406" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E V16.01.0.12(4843) was discovered to contain a Command Execution vulnerability via the function /goform/telnet. Shenzhen Tenda Technology Co.,Ltd. of w30e There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the failure of the handler function of /goform/telnet to correctly filter special characters, commands, etc. in the constructed command", "sources": [ { "db": "NVD", "id": "CVE-2023-49406" }, { "db": "JVNDB", "id": "JVNDB-2023-018801" }, { "db": "CNVD", "id": "CNVD-2023-98197" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-49406", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2023-018801", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-98197", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98197" }, { "db": "JVNDB", "id": "JVNDB-2023-018801" }, { "db": "NVD", "id": "CVE-2023-49406" } ] }, "id": "VAR-202312-0392", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-98197" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98197" } ] }, "last_update_date": "2024-01-18T22:59:11.139000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-noinfo", "trust": 1.0 }, { "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018801" }, { "db": "NVD", "id": "CVE-2023-49406" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/gd008/tenda/blob/main/w30e/tenda_w30e_telnet/w30e_telnet.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-49406" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98197" }, { "db": "JVNDB", "id": "JVNDB-2023-018801" }, { "db": "NVD", "id": "CVE-2023-49406" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-98197" }, { "db": "JVNDB", "id": "JVNDB-2023-018801" }, { "db": "NVD", "id": "CVE-2023-49406" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-15T00:00:00", "db": "CNVD", "id": "CNVD-2023-98197" }, { "date": "2024-01-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-018801" }, { "date": "2023-12-07T18:15:08.267000", "db": "NVD", "id": "CVE-2023-49406" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-18T00:00:00", "db": "CNVD", "id": "CNVD-2023-98197" }, { "date": "2024-01-12T01:18:00", "db": "JVNDB", "id": "JVNDB-2023-018801" }, { "date": "2023-12-09T04:44:58.333000", "db": "NVD", "id": "CVE-2023-49406" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Firmware vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018801" } ], "trust": 0.8 } }
var-202404-0306
Vulnerability from variot
A vulnerability classified as critical has been found in Tenda W30E 1.0/1.0.1.25. Affected is the function fromWizardHandle of the file /goform/WizardHandle. The manipulation of the argument PPW leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261990 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda W30E is a new Wi-Fi 6 enterprise-class wireless router designed for SOHO, small and micro-enterprise offices, small shops and other scenarios. No detailed vulnerability details are currently provided
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202404-0306", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "1.0.1.25" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23303" } ] }, "cve": "CVE-2024-4171", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-23303", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-4171", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-23303", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23303" }, { "db": "NVD", "id": "CVE-2024-4171" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability classified as critical has been found in Tenda W30E 1.0/1.0.1.25. Affected is the function fromWizardHandle of the file /goform/WizardHandle. The manipulation of the argument PPW leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261990 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda W30E is a new Wi-Fi 6 enterprise-class wireless router designed for SOHO, small and micro-enterprise offices, small shops and other scenarios. No detailed vulnerability details are currently provided", "sources": [ { "db": "NVD", "id": "CVE-2024-4171" }, { "db": "CNVD", "id": "CNVD-2024-23303" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-4171", "trust": 1.6 }, { "db": "VULDB", "id": "261990", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-23303", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23303" }, { "db": "NVD", "id": "CVE-2024-4171" } ] }, "id": "VAR-202404-0306", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-23303" } ], "trust": 1.0044734499999999 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23303" } ] }, "last_update_date": "2024-06-05T23:30:23.786000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-4171" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/fromwizardhandle.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.261990" }, { "trust": 1.0, "url": "https://vuldb.com/?id.261990" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.318995" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-4171" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23303" }, { "db": "NVD", "id": "CVE-2024-4171" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-23303" }, { "db": "NVD", "id": "CVE-2024-4171" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-15T00:00:00", "db": "CNVD", "id": "CNVD-2024-23303" }, { "date": "2024-04-25T14:15:10.180000", "db": "NVD", "id": "CVE-2024-4171" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-20T00:00:00", "db": "CNVD", "id": "CNVD-2024-23303" }, { "date": "2024-06-04T19:20:31.980000", "db": "NVD", "id": "CVE-2024-4171" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E Stack Buffer Overflow Vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-23303" } ], "trust": 0.6 } }
var-202212-0882
Vulnerability from variot
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the mit_ssid_index parameter at /goform/AdvSetWrlsafeset. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0882", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0.1.25\\(633\\)" }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "w30e firmware 1.0.1.25(633)" }, { "model": "w30e", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v1.0.1.25(633)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18917" }, { "db": "JVNDB", "id": "JVNDB-2022-022499" }, { "db": "NVD", "id": "CVE-2022-45510" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\\(633\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-45510" } ] }, "cve": "CVE-2022-45510", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2023-18917", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2022-45510", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-45510", "trust": 1.8, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2023-18917", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202212-2691", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18917" }, { "db": "JVNDB", "id": "JVNDB-2022-022499" }, { "db": "NVD", "id": "CVE-2022-45510" }, { "db": "CNNVD", "id": "CNNVD-202212-2691" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the mit_ssid_index parameter at /goform/AdvSetWrlsafeset. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2022-45510" }, { "db": "JVNDB", "id": "JVNDB-2022-022499" }, { "db": "CNVD", "id": "CNVD-2023-18917" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-45510", "trust": 3.8 }, { "db": "JVNDB", "id": "JVNDB-2022-022499", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-18917", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202212-2691", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18917" }, { "db": "JVNDB", "id": "JVNDB-2022-022499" }, { "db": "NVD", "id": "CVE-2022-45510" }, { "db": "CNNVD", "id": "CNNVD-202212-2691" } ] }, "id": "VAR-202212-0882", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-18917" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18917" } ] }, "last_update_date": "2023-12-18T13:22:03.449000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Tenda W30E Stack Overflow Vulnerability (CNVD-2023-18917)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/415606" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18917" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022499" }, { "db": "NVD", "id": "CVE-2022-45510" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/advsetwrlsafeset/readme.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45510" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-45510/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18917" }, { "db": "JVNDB", "id": "JVNDB-2022-022499" }, { "db": "NVD", "id": "CVE-2022-45510" }, { "db": "CNNVD", "id": "CNNVD-202212-2691" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-18917" }, { "db": "JVNDB", "id": "JVNDB-2022-022499" }, { "db": "NVD", "id": "CVE-2022-45510" }, { "db": "CNNVD", "id": "CNNVD-202212-2691" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-03-22T00:00:00", "db": "CNVD", "id": "CNVD-2023-18917" }, { "date": "2023-11-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-022499" }, { "date": "2022-12-08T16:15:14.083000", "db": "NVD", "id": "CVE-2022-45510" }, { "date": "2022-12-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-2691" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-03-22T00:00:00", "db": "CNVD", "id": "CNVD-2023-18917" }, { "date": "2023-11-17T08:19:00", "db": "JVNDB", "id": "JVNDB-2022-022499" }, { "date": "2022-12-09T13:24:41.273000", "db": "NVD", "id": "CVE-2022-45510" }, { "date": "2022-12-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-2691" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-2691" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022499" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-2691" } ], "trust": 0.6 } }
var-202212-0883
Vulnerability from variot
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the entries parameter at /goform/addressNat. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0883", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0.1.25\\(633\\)" }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "w30e firmware 1.0.1.25(633)" }, { "model": "w30e", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v1.0.1.25(633)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18923" }, { "db": "JVNDB", "id": "JVNDB-2022-022494" }, { "db": "NVD", "id": "CVE-2022-45515" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\\(633\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-45515" } ] }, "cve": "CVE-2022-45515", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2023-18923", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2022-45515", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-45515", "trust": 1.8, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2023-18923", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202212-2686", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18923" }, { "db": "JVNDB", "id": "JVNDB-2022-022494" }, { "db": "NVD", "id": "CVE-2022-45515" }, { "db": "CNNVD", "id": "CNNVD-202212-2686" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the entries parameter at /goform/addressNat. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2022-45515" }, { "db": "JVNDB", "id": "JVNDB-2022-022494" }, { "db": "CNVD", "id": "CNVD-2023-18923" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-45515", "trust": 3.8 }, { "db": "JVNDB", "id": "JVNDB-2022-022494", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-18923", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202212-2686", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18923" }, { "db": "JVNDB", "id": "JVNDB-2022-022494" }, { "db": "NVD", "id": "CVE-2022-45515" }, { "db": "CNNVD", "id": "CNNVD-202212-2686" } ] }, "id": "VAR-202212-0883", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-18923" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18923" } ] }, "last_update_date": "2023-12-18T12:48:22.620000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Tenda W30E Stack Overflow Vulnerability (CNVD-2023-18923)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/415626" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18923" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022494" }, { "db": "NVD", "id": "CVE-2022-45515" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/addressnat/readme.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45515" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-45515/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18923" }, { "db": "JVNDB", "id": "JVNDB-2022-022494" }, { "db": "NVD", "id": "CVE-2022-45515" }, { "db": "CNNVD", "id": "CNNVD-202212-2686" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-18923" }, { "db": "JVNDB", "id": "JVNDB-2022-022494" }, { "db": "NVD", "id": "CVE-2022-45515" }, { "db": "CNNVD", "id": "CNNVD-202212-2686" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-03-22T00:00:00", "db": "CNVD", "id": "CNVD-2023-18923" }, { "date": "2023-11-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-022494" }, { "date": "2022-12-08T16:15:14.303000", "db": "NVD", "id": "CVE-2022-45515" }, { "date": "2022-12-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-2686" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-03-22T00:00:00", "db": "CNVD", "id": "CNVD-2023-18923" }, { "date": "2023-11-17T08:18:00", "db": "JVNDB", "id": "JVNDB-2022-022494" }, { "date": "2022-12-10T02:17:10.127000", "db": "NVD", "id": "CVE-2022-45515" }, { "date": "2022-12-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-2686" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-2686" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022494" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-2686" } ], "trust": 0.6 } }
var-202212-0927
Vulnerability from variot
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeEmailFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0927", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0.1.25\\(633\\)" }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "w30e firmware 1.0.1.25(633)" }, { "model": "w30e", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v1.0.1.25(633)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18919" }, { "db": "JVNDB", "id": "JVNDB-2022-022497" }, { "db": "NVD", "id": "CVE-2022-45512" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\\(633\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-45512" } ] }, "cve": "CVE-2022-45512", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2023-18919", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2022-45512", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-45512", "trust": 1.8, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2023-18919", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202212-2689", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18919" }, { "db": "JVNDB", "id": "JVNDB-2022-022497" }, { "db": "NVD", "id": "CVE-2022-45512" }, { "db": "CNNVD", "id": "CNNVD-202212-2689" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeEmailFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2022-45512" }, { "db": "JVNDB", "id": "JVNDB-2022-022497" }, { "db": "CNVD", "id": "CNVD-2023-18919" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-45512", "trust": 3.8 }, { "db": "JVNDB", "id": "JVNDB-2022-022497", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-18919", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202212-2689", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18919" }, { "db": "JVNDB", "id": "JVNDB-2022-022497" }, { "db": "NVD", "id": "CVE-2022-45512" }, { "db": "CNNVD", "id": "CNNVD-202212-2689" } ] }, "id": "VAR-202212-0927", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-18919" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18919" } ] }, "last_update_date": "2023-12-18T13:55:06.569000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Tenda W30E Stack Overflow Vulnerability (CNVD-2023-18919)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/415611" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18919" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022497" }, { "db": "NVD", "id": "CVE-2022-45512" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/safeemailfilter/readme.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45512" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-45512/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18919" }, { "db": "JVNDB", "id": "JVNDB-2022-022497" }, { "db": "NVD", "id": "CVE-2022-45512" }, { "db": "CNNVD", "id": "CNNVD-202212-2689" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-18919" }, { "db": "JVNDB", "id": "JVNDB-2022-022497" }, { "db": "NVD", "id": "CVE-2022-45512" }, { "db": "CNNVD", "id": "CNNVD-202212-2689" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-03-22T00:00:00", "db": "CNVD", "id": "CNVD-2023-18919" }, { "date": "2023-11-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-022497" }, { "date": "2022-12-08T16:15:14.173000", "db": "NVD", "id": "CVE-2022-45512" }, { "date": "2022-12-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-2689" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-03-22T00:00:00", "db": "CNVD", "id": "CNVD-2023-18919" }, { "date": "2023-11-17T08:19:00", "db": "JVNDB", "id": "JVNDB-2022-022497" }, { "date": "2022-12-10T02:12:44.953000", "db": "NVD", "id": "CVE-2022-45512" }, { "date": "2022-12-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-2689" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-2689" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022497" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-2689" } ], "trust": 0.6 } }
var-202312-0391
Vulnerability from variot
Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function UploadCfg. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability is caused by the function UploadCfg failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202312-0391", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.01.0.12\\(4843\\)" }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "w30e firmware 16.01.0.12(4843)" }, { "model": "w30e", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v16.01.0.12(4843)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98202" }, { "db": "JVNDB", "id": "JVNDB-2023-018800" }, { "db": "NVD", "id": "CVE-2023-49405" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:w30e_firmware:16.01.0.12\\(4843\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-49405" } ] }, "cve": "CVE-2023-49405", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-98202", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-49405", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-49405", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2023-98202", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98202" }, { "db": "JVNDB", "id": "JVNDB-2023-018800" }, { "db": "NVD", "id": "CVE-2023-49405" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function UploadCfg. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability is caused by the function UploadCfg failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack", "sources": [ { "db": "NVD", "id": "CVE-2023-49405" }, { "db": "JVNDB", "id": "JVNDB-2023-018800" }, { "db": "CNVD", "id": "CNVD-2023-98202" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-49405", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2023-018800", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-98202", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98202" }, { "db": "JVNDB", "id": "JVNDB-2023-018800" }, { "db": "NVD", "id": "CVE-2023-49405" } ] }, "id": "VAR-202312-0391", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-98202" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98202" } ] }, "last_update_date": "2024-01-18T22:29:17.338000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018800" }, { "db": "NVD", "id": "CVE-2023-49405" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/gd008/tenda/blob/main/w30e/tenda_w30e_uploadcfg/w30e_uploadcfg.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-49405" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98202" }, { "db": "JVNDB", "id": "JVNDB-2023-018800" }, { "db": "NVD", "id": "CVE-2023-49405" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-98202" }, { "db": "JVNDB", "id": "JVNDB-2023-018800" }, { "db": "NVD", "id": "CVE-2023-49405" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-15T00:00:00", "db": "CNVD", "id": "CNVD-2023-98202" }, { "date": "2024-01-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-018800" }, { "date": "2023-12-07T18:15:08.220000", "db": "NVD", "id": "CVE-2023-49405" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-18T00:00:00", "db": "CNVD", "id": "CNVD-2023-98202" }, { "date": "2024-01-12T01:18:00", "db": "JVNDB", "id": "JVNDB-2023-018800" }, { "date": "2023-12-09T04:44:51.417000", "db": "NVD", "id": "CVE-2023-49405" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018800" } ], "trust": 0.8 } }
var-202212-0935
Vulnerability from variot
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/P2pListFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0935", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0.1.25\\(633\\)" }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "w30e firmware 1.0.1.25(633)" }, { "model": "w30e", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v1.0.1.25(633)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18920" }, { "db": "JVNDB", "id": "JVNDB-2022-022496" }, { "db": "NVD", "id": "CVE-2022-45513" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\\(633\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-45513" } ] }, "cve": "CVE-2022-45513", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2023-18920", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2022-45513", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-45513", "trust": 1.8, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2023-18920", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202212-2688", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18920" }, { "db": "JVNDB", "id": "JVNDB-2022-022496" }, { "db": "NVD", "id": "CVE-2022-45513" }, { "db": "CNNVD", "id": "CNNVD-202212-2688" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/P2pListFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2022-45513" }, { "db": "JVNDB", "id": "JVNDB-2022-022496" }, { "db": "CNVD", "id": "CNVD-2023-18920" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-45513", "trust": 3.8 }, { "db": "JVNDB", "id": "JVNDB-2022-022496", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-18920", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202212-2688", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18920" }, { "db": "JVNDB", "id": "JVNDB-2022-022496" }, { "db": "NVD", "id": "CVE-2022-45513" }, { "db": "CNNVD", "id": "CNNVD-202212-2688" } ] }, "id": "VAR-202212-0935", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-18920" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18920" } ] }, "last_update_date": "2023-12-18T13:06:21.855000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Tenda W30E Stack Overflow Vulnerability (CNVD-2023-18920)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/415616" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18920" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022496" }, { "db": "NVD", "id": "CVE-2022-45513" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/p2plistfilter/readme.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45513" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-45513/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18920" }, { "db": "JVNDB", "id": "JVNDB-2022-022496" }, { "db": "NVD", "id": "CVE-2022-45513" }, { "db": "CNNVD", "id": "CNNVD-202212-2688" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-18920" }, { "db": "JVNDB", "id": "JVNDB-2022-022496" }, { "db": "NVD", "id": "CVE-2022-45513" }, { "db": "CNNVD", "id": "CNNVD-202212-2688" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-03-22T00:00:00", "db": "CNVD", "id": "CNVD-2023-18920" }, { "date": "2023-11-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-022496" }, { "date": "2022-12-08T16:15:14.217000", "db": "NVD", "id": "CVE-2022-45513" }, { "date": "2022-12-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-2688" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-03-22T00:00:00", "db": "CNVD", "id": "CNVD-2023-18920" }, { "date": "2023-11-17T08:19:00", "db": "JVNDB", "id": "JVNDB-2022-022496" }, { "date": "2022-12-10T02:12:36.097000", "db": "NVD", "id": "CVE-2022-45513" }, { "date": "2022-12-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-2688" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-2688" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022496" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-2688" } ], "trust": 0.6 } }
var-202312-0420
Vulnerability from variot
Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formResetMeshNode. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the function formResetMeshNode failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202312-0420", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.01.0.12\\(4843\\)" }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "w30e firmware 16.01.0.12(4843)" }, { "model": "w30e", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v16.01.0.12(4843)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98195" }, { "db": "JVNDB", "id": "JVNDB-2023-018796" }, { "db": "NVD", "id": "CVE-2023-50000" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:w30e_firmware:16.01.0.12\\(4843\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-50000" } ] }, "cve": "CVE-2023-50000", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-98195", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-50000", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-50000", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2023-98195", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98195" }, { "db": "JVNDB", "id": "JVNDB-2023-018796" }, { "db": "NVD", "id": "CVE-2023-50000" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formResetMeshNode. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the function formResetMeshNode failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack", "sources": [ { "db": "NVD", "id": "CVE-2023-50000" }, { "db": "JVNDB", "id": "JVNDB-2023-018796" }, { "db": "CNVD", "id": "CNVD-2023-98195" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-50000", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2023-018796", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-98195", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98195" }, { "db": "JVNDB", "id": "JVNDB-2023-018796" }, { "db": "NVD", "id": "CVE-2023-50000" } ] }, "id": "VAR-202312-0420", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-98195" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98195" } ] }, "last_update_date": "2024-01-18T23:00:42.536000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018796" }, { "db": "NVD", "id": "CVE-2023-50000" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/gd008/tenda/blob/main/w30e/tenda_w30e_resetmesh/w30e_resetmesh.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-50000" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98195" }, { "db": "JVNDB", "id": "JVNDB-2023-018796" }, { "db": "NVD", "id": "CVE-2023-50000" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-98195" }, { "db": "JVNDB", "id": "JVNDB-2023-018796" }, { "db": "NVD", "id": "CVE-2023-50000" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-15T00:00:00", "db": "CNVD", "id": "CNVD-2023-98195" }, { "date": "2024-01-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-018796" }, { "date": "2023-12-07T17:15:07.420000", "db": "NVD", "id": "CVE-2023-50000" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-18T00:00:00", "db": "CNVD", "id": "CNVD-2023-98195" }, { "date": "2024-01-12T01:18:00", "db": "JVNDB", "id": "JVNDB-2023-018796" }, { "date": "2023-12-09T04:45:09.690000", "db": "NVD", "id": "CVE-2023-50000" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018796" } ], "trust": 0.8 } }
var-202312-0403
Vulnerability from variot
Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formUpgradeMeshOnline. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the function formUpgradeMeshOnline failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202312-0403", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.01.0.12\\(4843\\)" }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "w30e firmware 16.01.0.12(4843)" }, { "model": "w30e", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v16.01.0.12(4843)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98196" }, { "db": "JVNDB", "id": "JVNDB-2023-018797" }, { "db": "NVD", "id": "CVE-2023-50001" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:w30e_firmware:16.01.0.12\\(4843\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-50001" } ] }, "cve": "CVE-2023-50001", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-98196", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-50001", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-50001", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2023-98196", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98196" }, { "db": "JVNDB", "id": "JVNDB-2023-018797" }, { "db": "NVD", "id": "CVE-2023-50001" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formUpgradeMeshOnline. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the function formUpgradeMeshOnline failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack", "sources": [ { "db": "NVD", "id": "CVE-2023-50001" }, { "db": "JVNDB", "id": "JVNDB-2023-018797" }, { "db": "CNVD", "id": "CNVD-2023-98196" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-50001", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2023-018797", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-98196", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98196" }, { "db": "JVNDB", "id": "JVNDB-2023-018797" }, { "db": "NVD", "id": "CVE-2023-50001" } ] }, "id": "VAR-202312-0403", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-98196" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98196" } ] }, "last_update_date": "2024-01-18T23:01:35.077000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018797" }, { "db": "NVD", "id": "CVE-2023-50001" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/gd008/tenda/blob/main/w30e/tenda_w30e_upgrademeshonline/w30e_upgrademeshonline.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-50001" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98196" }, { "db": "JVNDB", "id": "JVNDB-2023-018797" }, { "db": "NVD", "id": "CVE-2023-50001" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-98196" }, { "db": "JVNDB", "id": "JVNDB-2023-018797" }, { "db": "NVD", "id": "CVE-2023-50001" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-15T00:00:00", "db": "CNVD", "id": "CNVD-2023-98196" }, { "date": "2024-01-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-018797" }, { "date": "2023-12-07T17:15:07.467000", "db": "NVD", "id": "CVE-2023-50001" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-18T00:00:00", "db": "CNVD", "id": "CNVD-2023-98196" }, { "date": "2024-01-12T01:18:00", "db": "JVNDB", "id": "JVNDB-2023-018797" }, { "date": "2023-12-09T04:45:12.637000", "db": "NVD", "id": "CVE-2023-50001" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018797" } ], "trust": 0.8 } }
var-202312-0404
Vulnerability from variot
Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formRebootMeshNode. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the function formRebootMeshNode failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202312-0404", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.01.0.12\\(4843\\)" }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "w30e firmware 16.01.0.12(4843)" }, { "model": "w30e", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v16.01.0.12(4843)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98194" }, { "db": "JVNDB", "id": "JVNDB-2023-018798" }, { "db": "NVD", "id": "CVE-2023-50002" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:w30e_firmware:16.01.0.12\\(4843\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-50002" } ] }, "cve": "CVE-2023-50002", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-98194", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-50002", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-50002", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2023-98194", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98194" }, { "db": "JVNDB", "id": "JVNDB-2023-018798" }, { "db": "NVD", "id": "CVE-2023-50002" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formRebootMeshNode. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the function formRebootMeshNode failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack", "sources": [ { "db": "NVD", "id": "CVE-2023-50002" }, { "db": "JVNDB", "id": "JVNDB-2023-018798" }, { "db": "CNVD", "id": "CNVD-2023-98194" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-50002", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2023-018798", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-98194", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98194" }, { "db": "JVNDB", "id": "JVNDB-2023-018798" }, { "db": "NVD", "id": "CVE-2023-50002" } ] }, "id": "VAR-202312-0404", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-98194" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98194" } ] }, "last_update_date": "2024-01-18T22:45:27.132000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018798" }, { "db": "NVD", "id": "CVE-2023-50002" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/gd008/tenda/blob/main/w30e/tenda_w30e_rebootmesh/w30e_rebootmesh.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-50002" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98194" }, { "db": "JVNDB", "id": "JVNDB-2023-018798" }, { "db": "NVD", "id": "CVE-2023-50002" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-98194" }, { "db": "JVNDB", "id": "JVNDB-2023-018798" }, { "db": "NVD", "id": "CVE-2023-50002" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-15T00:00:00", "db": "CNVD", "id": "CNVD-2023-98194" }, { "date": "2024-01-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-018798" }, { "date": "2023-12-07T17:15:07.510000", "db": "NVD", "id": "CVE-2023-50002" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-18T00:00:00", "db": "CNVD", "id": "CNVD-2023-98194" }, { "date": "2024-01-12T01:18:00", "db": "JVNDB", "id": "JVNDB-2023-018798" }, { "date": "2023-12-09T04:45:15.093000", "db": "NVD", "id": "CVE-2023-50002" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018798" } ], "trust": 0.8 } }
var-202312-0453
Vulnerability from variot
Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function localMsg. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability is caused by the failure of the function localMsg to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202312-0453", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.01.0.12\\(4843\\)" }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "w30e firmware 16.01.0.12(4843)" }, { "model": "w30e", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v16.01.0.12(4843)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98198" }, { "db": "JVNDB", "id": "JVNDB-2023-018792" }, { "db": "NVD", "id": "CVE-2023-49402" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:w30e_firmware:16.01.0.12\\(4843\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-49402" } ] }, "cve": "CVE-2023-49402", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-98198", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-49402", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-49402", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2023-98198", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98198" }, { "db": "JVNDB", "id": "JVNDB-2023-018792" }, { "db": "NVD", "id": "CVE-2023-49402" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function localMsg. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability is caused by the failure of the function localMsg to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack", "sources": [ { "db": "NVD", "id": "CVE-2023-49402" }, { "db": "JVNDB", "id": "JVNDB-2023-018792" }, { "db": "CNVD", "id": "CNVD-2023-98198" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-49402", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2023-018792", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-98198", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98198" }, { "db": "JVNDB", "id": "JVNDB-2023-018792" }, { "db": "NVD", "id": "CVE-2023-49402" } ] }, "id": "VAR-202312-0453", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-98198" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98198" } ] }, "last_update_date": "2024-01-18T22:49:20.636000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018792" }, { "db": "NVD", "id": "CVE-2023-49402" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/gd008/tenda/blob/main/w30e/tenda_w30e_localmsg/w30e_localmsg.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-49402" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98198" }, { "db": "JVNDB", "id": "JVNDB-2023-018792" }, { "db": "NVD", "id": "CVE-2023-49402" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-98198" }, { "db": "JVNDB", "id": "JVNDB-2023-018792" }, { "db": "NVD", "id": "CVE-2023-49402" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-15T00:00:00", "db": "CNVD", "id": "CNVD-2023-98198" }, { "date": "2024-01-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-018792" }, { "date": "2023-12-07T17:15:07.227000", "db": "NVD", "id": "CVE-2023-49402" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-18T00:00:00", "db": "CNVD", "id": "CNVD-2023-98198" }, { "date": "2024-01-12T01:18:00", "db": "JVNDB", "id": "JVNDB-2023-018792" }, { "date": "2023-12-09T04:45:00.440000", "db": "NVD", "id": "CVE-2023-49402" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018792" } ], "trust": 0.8 } }
var-202312-0469
Vulnerability from variot
Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formAdvancedSetListSet. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability is caused by the function formAdvancedSetListSet failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202312-0469", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.01.0.12\\(4843\\)" }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "w30e firmware 16.01.0.12(4843)" }, { "model": "w30e", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v16.01.0.12(4843)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98052" }, { "db": "JVNDB", "id": "JVNDB-2023-018799" }, { "db": "NVD", "id": "CVE-2023-49404" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:w30e_firmware:16.01.0.12\\(4843\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-49404" } ] }, "cve": "CVE-2023-49404", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-98052", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-49404", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-49404", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2023-98052", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98052" }, { "db": "JVNDB", "id": "JVNDB-2023-018799" }, { "db": "NVD", "id": "CVE-2023-49404" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formAdvancedSetListSet. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability is caused by the function formAdvancedSetListSet failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack", "sources": [ { "db": "NVD", "id": "CVE-2023-49404" }, { "db": "JVNDB", "id": "JVNDB-2023-018799" }, { "db": "CNVD", "id": "CNVD-2023-98052" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-49404", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2023-018799", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-98052", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98052" }, { "db": "JVNDB", "id": "JVNDB-2023-018799" }, { "db": "NVD", "id": "CVE-2023-49404" } ] }, "id": "VAR-202312-0469", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-98052" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98052" } ] }, "last_update_date": "2024-01-18T22:52:33.011000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018799" }, { "db": "NVD", "id": "CVE-2023-49404" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/gd008/tenda/blob/main/w30e/tenda_w30e_setadvancedsetlist/w30e_setadvancedsetlist.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-49404" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98052" }, { "db": "JVNDB", "id": "JVNDB-2023-018799" }, { "db": "NVD", "id": "CVE-2023-49404" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-98052" }, { "db": "JVNDB", "id": "JVNDB-2023-018799" }, { "db": "NVD", "id": "CVE-2023-49404" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-15T00:00:00", "db": "CNVD", "id": "CNVD-2023-98052" }, { "date": "2024-01-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-018799" }, { "date": "2023-12-07T18:15:08.173000", "db": "NVD", "id": "CVE-2023-49404" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-15T00:00:00", "db": "CNVD", "id": "CNVD-2023-98052" }, { "date": "2024-01-12T01:18:00", "db": "JVNDB", "id": "JVNDB-2023-018799" }, { "date": "2023-12-09T04:44:49.273000", "db": "NVD", "id": "CVE-2023-49404" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018799" } ], "trust": 0.8 } }
var-202212-0849
Vulnerability from variot
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/webExcptypemanFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0849", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0.1.25\\(633\\)" }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "w30e firmware 1.0.1.25(633)" }, { "model": "w30e", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v1.0.1.25(633)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18921" }, { "db": "JVNDB", "id": "JVNDB-2022-022495" }, { "db": "NVD", "id": "CVE-2022-45514" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\\(633\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-45514" } ] }, "cve": "CVE-2022-45514", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2023-18921", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2022-45514", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-45514", "trust": 1.8, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2023-18921", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202212-2687", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18921" }, { "db": "JVNDB", "id": "JVNDB-2022-022495" }, { "db": "NVD", "id": "CVE-2022-45514" }, { "db": "CNNVD", "id": "CNNVD-202212-2687" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/webExcptypemanFilter. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2022-45514" }, { "db": "JVNDB", "id": "JVNDB-2022-022495" }, { "db": "CNVD", "id": "CNVD-2023-18921" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-45514", "trust": 3.8 }, { "db": "JVNDB", "id": "JVNDB-2022-022495", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-18921", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202212-2687", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18921" }, { "db": "JVNDB", "id": "JVNDB-2022-022495" }, { "db": "NVD", "id": "CVE-2022-45514" }, { "db": "CNNVD", "id": "CNNVD-202212-2687" } ] }, "id": "VAR-202212-0849", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-18921" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18921" } ] }, "last_update_date": "2023-12-18T11:55:18.079000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Tenda W30E Stack Overflow Vulnerability (CNVD-2023-18921)", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/415621" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18921" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022495" }, { "db": "NVD", "id": "CVE-2022-45514" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/webexcptypemanfilter/readme.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45514" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-45514/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18921" }, { "db": "JVNDB", "id": "JVNDB-2022-022495" }, { "db": "NVD", "id": "CVE-2022-45514" }, { "db": "CNNVD", "id": "CNNVD-202212-2687" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-18921" }, { "db": "JVNDB", "id": "JVNDB-2022-022495" }, { "db": "NVD", "id": "CVE-2022-45514" }, { "db": "CNNVD", "id": "CNNVD-202212-2687" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-03-22T00:00:00", "db": "CNVD", "id": "CNVD-2023-18921" }, { "date": "2023-11-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-022495" }, { "date": "2022-12-08T16:15:14.260000", "db": "NVD", "id": "CVE-2022-45514" }, { "date": "2022-12-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-2687" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-03-22T00:00:00", "db": "CNVD", "id": "CNVD-2023-18921" }, { "date": "2023-11-17T08:18:00", "db": "JVNDB", "id": "JVNDB-2022-022495" }, { "date": "2022-12-10T02:12:23.867000", "db": "NVD", "id": "CVE-2022-45514" }, { "date": "2022-12-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-2687" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-2687" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022495" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-2687" } ], "trust": 0.6 } }
var-202404-0080
Vulnerability from variot
A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda W30E is a wireless router developed by Tenda, mainly used to provide stable network connections for homes and small offices.
There is a stack buffer overflow vulnerability in the formSetCfm function of the /goform/setcfm file in Tenda W30E 1.0.1.25(633) version. An attacker can exploit this vulnerability to cause a stack overflow by remotely manipulating the funcpara1 parameter
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202404-0080", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "1.0.1.25(633)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-18610" } ] }, "cve": "CVE-2024-3879", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-18610", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-3879", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-18610", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-18610" }, { "db": "NVD", "id": "CVE-2024-3879" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda W30E is a wireless router developed by Tenda, mainly used to provide stable network connections for homes and small offices. \n\nThere is a stack buffer overflow vulnerability in the formSetCfm function of the /goform/setcfm file in Tenda W30E 1.0.1.25(633) version. An attacker can exploit this vulnerability to cause a stack overflow by remotely manipulating the funcpara1 parameter", "sources": [ { "db": "NVD", "id": "CVE-2024-3879" }, { "db": "CNVD", "id": "CNVD-2024-18610" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-3879", "trust": 1.6 }, { "db": "VULDB", "id": "260913", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-18610", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-18610" }, { "db": "NVD", "id": "CVE-2024-3879" } ] }, "id": "VAR-202404-0080", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-18610" } ], "trust": 1.0044734499999999 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-18610" } ] }, "last_update_date": "2024-05-17T22:57:32.659000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-3879" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/formsetcfm.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.260913" }, { "trust": 1.0, "url": "https://vuldb.com/?id.260913" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.312822" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-3879" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-18610" }, { "db": "NVD", "id": "CVE-2024-3879" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-18610" }, { "db": "NVD", "id": "CVE-2024-3879" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-04-19T00:00:00", "db": "CNVD", "id": "CNVD-2024-18610" }, { "date": "2024-04-16T19:15:08.133000", "db": "NVD", "id": "CVE-2024-3879" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-04-19T00:00:00", "db": "CNVD", "id": "CNVD-2024-18610" }, { "date": "2024-05-17T02:40:10.177000", "db": "NVD", "id": "CVE-2024-3879" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E formSetCfm function stack buffer overflow vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-18610" } ], "trust": 0.6 } }
var-202312-0480
Vulnerability from variot
Tenda W30E V16.01.0.12(4843) contains a stack overflow vulnerability via the function formDeleteMeshNode. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability is caused by the function formDeleteMeshNode failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202312-0480", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.01.0.12\\(4843\\)" }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "w30e firmware 16.01.0.12(4843)" }, { "model": "w30e", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v16.01.0.12(4843)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98053" }, { "db": "JVNDB", "id": "JVNDB-2023-018804" }, { "db": "NVD", "id": "CVE-2023-49411" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:w30e_firmware:16.01.0.12\\(4843\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-49411" } ] }, "cve": "CVE-2023-49411", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-98053", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-49411", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-49411", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2023-98053", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98053" }, { "db": "JVNDB", "id": "JVNDB-2023-018804" }, { "db": "NVD", "id": "CVE-2023-49411" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E V16.01.0.12(4843) contains a stack overflow vulnerability via the function formDeleteMeshNode. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability is caused by the function formDeleteMeshNode failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack", "sources": [ { "db": "NVD", "id": "CVE-2023-49411" }, { "db": "JVNDB", "id": "JVNDB-2023-018804" }, { "db": "CNVD", "id": "CNVD-2023-98053" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-49411", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2023-018804", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-98053", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98053" }, { "db": "JVNDB", "id": "JVNDB-2023-018804" }, { "db": "NVD", "id": "CVE-2023-49411" } ] }, "id": "VAR-202312-0480", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-98053" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98053" } ] }, "last_update_date": "2024-01-18T22:54:54.448000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018804" }, { "db": "NVD", "id": "CVE-2023-49411" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/gd008/tenda/blob/main/w30e/tenda_w30e_deletemesh/w30e_deletemesh.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-49411" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98053" }, { "db": "JVNDB", "id": "JVNDB-2023-018804" }, { "db": "NVD", "id": "CVE-2023-49411" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-98053" }, { "db": "JVNDB", "id": "JVNDB-2023-018804" }, { "db": "NVD", "id": "CVE-2023-49411" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-15T00:00:00", "db": "CNVD", "id": "CNVD-2023-98053" }, { "date": "2024-01-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-018804" }, { "date": "2023-12-07T18:15:08.400000", "db": "NVD", "id": "CVE-2023-49411" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-15T00:00:00", "db": "CNVD", "id": "CNVD-2023-98053" }, { "date": "2024-01-12T01:18:00", "db": "JVNDB", "id": "JVNDB-2023-018804" }, { "date": "2023-12-09T04:44:46.703000", "db": "NVD", "id": "CVE-2023-49411" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018804" } ], "trust": 0.8 } }
var-202212-0969
Vulnerability from variot
Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the account parameter at /goform/addUserName. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202212-0969", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "1.0.1.25\\(633\\)" }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "w30e firmware 1.0.1.25(633)" }, { "model": "w30e", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v1.0.1.25(633)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18918" }, { "db": "JVNDB", "id": "JVNDB-2022-022500" }, { "db": "NVD", "id": "CVE-2022-45509" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\\(633\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-45509" } ] }, "cve": "CVE-2022-45509", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2023-18918", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2022-45509", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-45509", "trust": 1.8, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2023-18918", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202212-2692", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18918" }, { "db": "JVNDB", "id": "JVNDB-2022-022500" }, { "db": "NVD", "id": "CVE-2022-45509" }, { "db": "CNNVD", "id": "CNNVD-202212-2692" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the account parameter at /goform/addUserName. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state", "sources": [ { "db": "NVD", "id": "CVE-2022-45509" }, { "db": "JVNDB", "id": "JVNDB-2022-022500" }, { "db": "CNVD", "id": "CNVD-2023-18918" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-45509", "trust": 3.8 }, { "db": "JVNDB", "id": "JVNDB-2022-022500", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-18918", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202212-2692", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18918" }, { "db": "JVNDB", "id": "JVNDB-2022-022500" }, { "db": "NVD", "id": "CVE-2022-45509" }, { "db": "CNNVD", "id": "CNNVD-202212-2692" } ] }, "id": "VAR-202212-0969", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-18918" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18918" } ] }, "last_update_date": "2023-12-18T13:55:06.545000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Patch for Tenda W30E Stack Overflow Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/415601" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18918" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022500" }, { "db": "NVD", "id": "CVE-2022-45509" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.4, "url": "https://github.com/z1r00/iot_vul/blob/main/tenda/w30e/addusername/readme.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-45509" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2022-45509/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-18918" }, { "db": "JVNDB", "id": "JVNDB-2022-022500" }, { "db": "NVD", "id": "CVE-2022-45509" }, { "db": "CNNVD", "id": "CNNVD-202212-2692" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-18918" }, { "db": "JVNDB", "id": "JVNDB-2022-022500" }, { "db": "NVD", "id": "CVE-2022-45509" }, { "db": "CNNVD", "id": "CNNVD-202212-2692" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-03-22T00:00:00", "db": "CNVD", "id": "CNVD-2023-18918" }, { "date": "2023-11-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-022500" }, { "date": "2022-12-08T16:15:14.040000", "db": "NVD", "id": "CVE-2022-45509" }, { "date": "2022-12-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-2692" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-03-22T00:00:00", "db": "CNVD", "id": "CNVD-2023-18918" }, { "date": "2023-11-17T08:19:00", "db": "JVNDB", "id": "JVNDB-2022-022500" }, { "date": "2022-12-09T13:24:24.417000", "db": "NVD", "id": "CVE-2022-45509" }, { "date": "2022-12-12T00:00:00", "db": "CNNVD", "id": "CNNVD-202212-2692" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-2692" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-022500" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202212-2692" } ], "trust": 0.6 } }
var-202404-0125
Vulnerability from variot
A vulnerability was found in Tenda W30E 1.0.1.25(633) and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260915. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda W30E is a wireless router developed by Tenda. The device provides wireless network connection and Internet access.
In Tenda W30E 1.0.1.25(633) version, there is a stack buffer overflow vulnerability in the frmL7PlotForm function of the /goform/frmL7ProtForm file. The vulnerability is caused by improper processing of the incoming parameter page. A remote attacker can exploit this vulnerability to execute arbitrary code
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202404-0125", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "1.0.1.25(633)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20266" } ] }, "cve": "CVE-2024-3881", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-20266", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-3881", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-20266", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20266" }, { "db": "NVD", "id": "CVE-2024-3881" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability was found in Tenda W30E 1.0.1.25(633) and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260915. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda W30E is a wireless router developed by Tenda. The device provides wireless network connection and Internet access. \n\nIn Tenda W30E 1.0.1.25(633) version, there is a stack buffer overflow vulnerability in the frmL7PlotForm function of the /goform/frmL7ProtForm file. The vulnerability is caused by improper processing of the incoming parameter page. A remote attacker can exploit this vulnerability to execute arbitrary code", "sources": [ { "db": "NVD", "id": "CVE-2024-3881" }, { "db": "CNVD", "id": "CNVD-2024-20266" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-3881", "trust": 1.6 }, { "db": "VULDB", "id": "260915", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-20266", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20266" }, { "db": "NVD", "id": "CVE-2024-3881" } ] }, "id": "VAR-202404-0125", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-20266" } ], "trust": 1.0044734499999999 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20266" } ] }, "last_update_date": "2024-05-17T22:59:14.546000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-3881" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/frml7protform.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.260915" }, { "trust": 1.0, "url": "https://vuldb.com/?id.260915" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.312824" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-3881" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20266" }, { "db": "NVD", "id": "CVE-2024-3881" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-20266" }, { "db": "NVD", "id": "CVE-2024-3881" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-04-19T00:00:00", "db": "CNVD", "id": "CNVD-2024-20266" }, { "date": "2024-04-16T20:15:10.280000", "db": "NVD", "id": "CVE-2024-3881" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-04-25T00:00:00", "db": "CNVD", "id": "CNVD-2024-20266" }, { "date": "2024-05-17T02:40:10.360000", "db": "NVD", "id": "CVE-2024-3881" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E frmL7PlotForm function stack buffer overflow vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-20266" } ], "trust": 0.6 } }
var-202404-0181
Vulnerability from variot
A vulnerability has been found in Tenda W30E 1.0.1.25(633) and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-260914 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda W30E is a wireless router device that provides Internet access, wireless coverage and other functions.
In the 1.0.1.25(633) version of Tenda W30E, the formWriteFacMac function of the /goform/WriteFacMac file has a command injection vulnerability, which can be exploited by attackers to execute arbitrary commands
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202404-0181", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "1.0.1.25(633)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20265" } ] }, "cve": "CVE-2024-3880", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 6.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.0, "id": "CNVD-2024-20265", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "LOW", "baseScore": 6.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "exploitabilityScore": 2.8, "impactScore": 3.4, "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-3880", "trust": 1.0, "value": "MEDIUM" }, { "author": "CNVD", "id": "CNVD-2024-20265", "trust": 0.6, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20265" }, { "db": "NVD", "id": "CVE-2024-3880" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been found in Tenda W30E 1.0.1.25(633) and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-260914 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda W30E is a wireless router device that provides Internet access, wireless coverage and other functions. \n\nIn the 1.0.1.25(633) version of Tenda W30E, the formWriteFacMac function of the /goform/WriteFacMac file has a command injection vulnerability, which can be exploited by attackers to execute arbitrary commands", "sources": [ { "db": "NVD", "id": "CVE-2024-3880" }, { "db": "CNVD", "id": "CNVD-2024-20265" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-3880", "trust": 1.6 }, { "db": "VULDB", "id": "260914", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-20265", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20265" }, { "db": "NVD", "id": "CVE-2024-3880" } ] }, "id": "VAR-202404-0181", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-20265" } ], "trust": 1.0044734499999999 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20265" } ] }, "last_update_date": "2024-06-05T23:24:25.988000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-78", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-3880" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/formwritefacmac.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.260914" }, { "trust": 1.0, "url": "https://vuldb.com/?id.260914" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.312823" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-3880" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-20265" }, { "db": "NVD", "id": "CVE-2024-3880" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-20265" }, { "db": "NVD", "id": "CVE-2024-3880" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-04-19T00:00:00", "db": "CNVD", "id": "CNVD-2024-20265" }, { "date": "2024-04-16T19:15:08.357000", "db": "NVD", "id": "CVE-2024-3880" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-04-25T00:00:00", "db": "CNVD", "id": "CNVD-2024-20265" }, { "date": "2024-06-04T19:20:26", "db": "NVD", "id": "CVE-2024-3880" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E Command Injection Vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-20265" } ], "trust": 0.6 } }
var-202312-0418
Vulnerability from variot
Tenda W30E V16.01.0.12(4843) was discovered to contain a command injection vulnerability via the function setFixTools. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the failure of the setFixTools function to correctly filter special characters, commands, etc. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202312-0418", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.01.0.12\\(4843\\)" }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "w30e firmware 16.01.0.12(4843)" }, { "model": "w30e", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v16.01.0.12(4843)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98200" }, { "db": "JVNDB", "id": "JVNDB-2023-018793" }, { "db": "NVD", "id": "CVE-2023-49403" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:w30e_firmware:16.01.0.12\\(4843\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-49403" } ] }, "cve": "CVE-2023-49403", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-98200", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-49403", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-49403", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2023-98200", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98200" }, { "db": "JVNDB", "id": "JVNDB-2023-018793" }, { "db": "NVD", "id": "CVE-2023-49403" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E V16.01.0.12(4843) was discovered to contain a command injection vulnerability via the function setFixTools. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the failure of the setFixTools function to correctly filter special characters, commands, etc. in the constructed command. An attacker could exploit this vulnerability to cause arbitrary command execution", "sources": [ { "db": "NVD", "id": "CVE-2023-49403" }, { "db": "JVNDB", "id": "JVNDB-2023-018793" }, { "db": "CNVD", "id": "CNVD-2023-98200" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-49403", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2023-018793", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-98200", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98200" }, { "db": "JVNDB", "id": "JVNDB-2023-018793" }, { "db": "NVD", "id": "CVE-2023-49403" } ] }, "id": "VAR-202312-0418", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-98200" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98200" } ] }, "last_update_date": "2024-01-18T22:56:37.470000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018793" }, { "db": "NVD", "id": "CVE-2023-49403" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/gd008/tenda/blob/main/w30e/tenda_w30e_setfixtools/w30e_setfixtools.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-49403" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98200" }, { "db": "JVNDB", "id": "JVNDB-2023-018793" }, { "db": "NVD", "id": "CVE-2023-49403" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-98200" }, { "db": "JVNDB", "id": "JVNDB-2023-018793" }, { "db": "NVD", "id": "CVE-2023-49403" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-15T00:00:00", "db": "CNVD", "id": "CNVD-2023-98200" }, { "date": "2024-01-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-018793" }, { "date": "2023-12-07T17:15:07.280000", "db": "NVD", "id": "CVE-2023-49403" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-18T00:00:00", "db": "CNVD", "id": "CNVD-2023-98200" }, { "date": "2024-01-12T01:18:00", "db": "JVNDB", "id": "JVNDB-2023-018793" }, { "date": "2023-12-09T04:45:02.677000", "db": "NVD", "id": "CVE-2023-49403" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018793" } ], "trust": 0.8 } }
var-202404-0124
Vulnerability from variot
A vulnerability was found in Tenda W30E 1.0.1.25(633). It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260916. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. The vulnerability is caused by the parameter page of the fromRouteStatic function of /goform/fromRouteStatic failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202404-0124", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "1.0.1.25(633)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-18608" } ] }, "cve": "CVE-2024-3882", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-18608", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-3882", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-18608", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-18608" }, { "db": "NVD", "id": "CVE-2024-3882" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability was found in Tenda W30E 1.0.1.25(633). It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260916. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. The vulnerability is caused by the parameter page of the fromRouteStatic function of /goform/fromRouteStatic failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack", "sources": [ { "db": "NVD", "id": "CVE-2024-3882" }, { "db": "CNVD", "id": "CNVD-2024-18608" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-3882", "trust": 1.6 }, { "db": "VULDB", "id": "260916", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-18608", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-18608" }, { "db": "NVD", "id": "CVE-2024-3882" } ] }, "id": "VAR-202404-0124", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-18608" } ], "trust": 1.0044734499999999 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-18608" } ] }, "last_update_date": "2024-05-17T23:11:01.530000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-3882" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/w30e/fromroutestatic.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.260916" }, { "trust": 1.0, "url": "https://vuldb.com/?id.260916" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.312825" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-3882" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-18608" }, { "db": "NVD", "id": "CVE-2024-3882" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-18608" }, { "db": "NVD", "id": "CVE-2024-3882" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-04-19T00:00:00", "db": "CNVD", "id": "CNVD-2024-18608" }, { "date": "2024-04-16T20:15:10.523000", "db": "NVD", "id": "CVE-2024-3882" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-04-19T00:00:00", "db": "CNVD", "id": "CNVD-2024-18608" }, { "date": "2024-05-17T02:40:10.457000", "db": "NVD", "id": "CVE-2024-3882" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E fromRouteStatic function buffer overflow vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-18608" } ], "trust": 0.6 } }
var-202312-0419
Vulnerability from variot
Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function via the function set_wan_status. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.
There is a buffer overflow vulnerability in Tenda W30E V16.01.0.12 (4843). This vulnerability is caused by the function set_wan_status failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202312-0419", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "w30e", "scope": "eq", "trust": 1.0, "vendor": "tenda", "version": "16.01.0.12\\(4843\\)" }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": "w30e firmware 16.01.0.12(4843)" }, { "model": "w30e", "scope": null, "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.8, "vendor": "tenda", "version": null }, { "model": "w30e", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "v16.01.0.12(4843)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98199" }, { "db": "JVNDB", "id": "JVNDB-2023-018794" }, { "db": "NVD", "id": "CVE-2023-49410" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:tenda:w30e_firmware:16.01.0.12\\(4843\\):*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-49410" } ] }, "cve": "CVE-2023-49410", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 10.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 10.0, "id": "CNVD-2023-98199", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-49410", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-49410", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2023-98199", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98199" }, { "db": "JVNDB", "id": "JVNDB-2023-018794" }, { "db": "NVD", "id": "CVE-2023-49410" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function via the function set_wan_status. Shenzhen Tenda Technology Co.,Ltd. of w30e An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\r\n\r\nThere is a buffer overflow vulnerability in Tenda W30E V16.01.0.12 (4843). This vulnerability is caused by the function set_wan_status failing to correctly verify the length of the input data. A remote attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service. attack", "sources": [ { "db": "NVD", "id": "CVE-2023-49410" }, { "db": "JVNDB", "id": "JVNDB-2023-018794" }, { "db": "CNVD", "id": "CNVD-2023-98199" } ], "trust": 2.16 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-49410", "trust": 3.2 }, { "db": "JVNDB", "id": "JVNDB-2023-018794", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2023-98199", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98199" }, { "db": "JVNDB", "id": "JVNDB-2023-018794" }, { "db": "NVD", "id": "CVE-2023-49410" } ] }, "id": "VAR-202312-0419", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-98199" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98199" } ] }, "last_update_date": "2024-01-18T22:39:25.592000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018794" }, { "db": "NVD", "id": "CVE-2023-49410" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://github.com/gd008/tenda/blob/main/w30e/tenda_w30e_setipv6status/w30e_setipv6status.md" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-49410" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-98199" }, { "db": "JVNDB", "id": "JVNDB-2023-018794" }, { "db": "NVD", "id": "CVE-2023-49410" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2023-98199" }, { "db": "JVNDB", "id": "JVNDB-2023-018794" }, { "db": "NVD", "id": "CVE-2023-49410" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-15T00:00:00", "db": "CNVD", "id": "CNVD-2023-98199" }, { "date": "2024-01-12T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-018794" }, { "date": "2023-12-07T17:15:07.323000", "db": "NVD", "id": "CVE-2023-49410" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-12-18T00:00:00", "db": "CNVD", "id": "CNVD-2023-98199" }, { "date": "2024-01-12T01:18:00", "db": "JVNDB", "id": "JVNDB-2023-018794" }, { "date": "2023-12-09T04:45:05.273000", "db": "NVD", "id": "CVE-2023-49410" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0w30e\u00a0 Out-of-bounds write vulnerability in firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-018794" } ], "trust": 0.8 } }
cve-2022-45519
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:03.852Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/SafeMacFilter/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the Go parameter at /goform/SafeMacFilter." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/SafeMacFilter/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45519", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:03.852Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45524
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:03.867Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/IPSECsave/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the opttype parameter at /goform/IPSECsave." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/IPSECsave/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45524", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:03.867Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49405
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:53:45.079Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_UploadCfg/w30e_UploadCfg.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function UploadCfg." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-07T17:31:49.005161", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_UploadCfg/w30e_UploadCfg.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-49405", "datePublished": "2023-12-07T00:00:00", "dateReserved": "2023-11-27T00:00:00", "dateUpdated": "2024-08-02T21:53:45.079Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45523
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:03.808Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/L7Im/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/L7Im." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/L7Im/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45523", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:03.808Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45517
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:03.935Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/VirtualSer/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/VirtualSer." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/VirtualSer/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45517", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:03.935Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45508
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:03.587Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/editUserName/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the new_account parameter at /goform/editUserName." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/editUserName/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45508", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:03.587Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45509
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:03.550Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/addUserName/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the account parameter at /goform/addUserName." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/addUserName/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45509", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:03.550Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45515
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:03.938Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/addressNat/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the entries parameter at /goform/addressNat." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/addressNat/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45515", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:03.938Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45510
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:04.064Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/AdvSetWrlsafeset/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the mit_ssid_index parameter at /goform/AdvSetWrlsafeset." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/AdvSetWrlsafeset/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45510", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:04.064Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45521
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:03.853Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/SafeUrlFilter/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeUrlFilter." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/SafeUrlFilter/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45521", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:03.853Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49406
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:53:45.130Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_telnet/w30e_telnet.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V16.01.0.12(4843) was discovered to contain a Command Execution vulnerability via the function /goform/telnet." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-07T17:29:38.381336", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_telnet/w30e_telnet.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-49406", "datePublished": "2023-12-07T00:00:00", "dateReserved": "2023-11-27T00:00:00", "dateUpdated": "2024-08-02T21:53:45.130Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45511
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:03.948Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/QuickIndex/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the PPPOEPassword parameter at /goform/QuickIndex." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/QuickIndex/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45511", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:03.948Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49411
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:53:45.404Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_deleteMesh/w30e_deleteMesh.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V16.01.0.12(4843) contains a stack overflow vulnerability via the function formDeleteMeshNode." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-07T17:33:16.490776", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_deleteMesh/w30e_deleteMesh.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-49411", "datePublished": "2023-12-07T00:00:00", "dateReserved": "2023-11-27T00:00:00", "dateUpdated": "2024-08-02T21:53:45.404Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-4171
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.261990 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.261990 | signature, permissions-required | |
https://vuldb.com/?submit.318995 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/fromWizardHandle.md | exploit |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-4171", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-04-30T14:58:38.325947Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:53:14.452Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:33:52.999Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-261990 | Tenda W30E WizardHandle fromWizardHandle stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.261990" }, { "name": "VDB-261990 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.261990" }, { "name": "Submit #318995 | Tenda W30Ev1.0 V1.0.1.25(633) Buffer Overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.318995" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/fromWizardHandle.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "W30E", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0" }, { "status": "affected", "version": "1.0.1.25" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_tutu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical has been found in Tenda W30E 1.0/1.0.1.25. Affected is the function fromWizardHandle of the file /goform/WizardHandle. The manipulation of the argument PPW leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-261990 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine kritische Schwachstelle in Tenda W30E 1.0/1.0.1.25 entdeckt. Es betrifft die Funktion fromWizardHandle der Datei /goform/WizardHandle. Durch die Manipulation des Arguments PPW mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-25T13:31:05.998Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-261990 | Tenda W30E WizardHandle fromWizardHandle stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.261990" }, { "name": "VDB-261990 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.261990" }, { "name": "Submit #318995 | Tenda W30Ev1.0 V1.0.1.25(633) Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.318995" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/fromWizardHandle.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-25T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-25T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-25T06:46:59.000Z", "value": "VulDB entry last update" } ], "title": "Tenda W30E WizardHandle fromWizardHandle stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-4171", "datePublished": "2024-04-25T13:31:05.998Z", "dateReserved": "2024-04-25T04:41:54.770Z", "dateUpdated": "2024-08-01T20:33:52.999Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-25231
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:18:36.135Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/104" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda Router W30E V1.0.1.25(633) is vulnerable to Buffer Overflow in function fromRouteStatic via parameters entrys and mitInterface." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-02-27T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/Funcy33/Vluninfo_Repo/tree/main/CNVDs/104" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-25231", "datePublished": "2023-02-27T00:00:00", "dateReserved": "2023-02-06T00:00:00", "dateUpdated": "2024-08-02T11:18:36.135Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49999
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T22:09:49.625Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_setUmountUSBPartition/w30e_setUmountUSBPartition.md" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-49999", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2023-12-13T16:58:08.439467Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-11-26T15:30:10.704Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V16.01.0.12(4843) was discovered to contain a command injection vulnerability via the function setUmountUSBPartition." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-07T17:01:10.192245", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_setUmountUSBPartition/w30e_setUmountUSBPartition.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-49999", "datePublished": "2023-12-07T00:00:00", "dateReserved": "2023-12-04T00:00:00", "dateUpdated": "2024-11-26T15:30:10.704Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45507
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:03.637Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/editFileName/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the editNameMit parameter at /goform/editFileName." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/editFileName/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45507", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:03.637Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45520
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:04.018Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/qossetting/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/qossetting." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/qossetting/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45520", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:04.018Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-3880
Vulnerability from cvelistv5
6.3 (Medium) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.260914 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.260914 | signature, permissions-required | |
https://vuldb.com/?submit.312823 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/formWriteFacMac.md | exploit |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "w30e", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.1.25(633)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-3880", "options": [ { "Exploitation": "poc" }, { "Automatable": "yes" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-04-26T14:47:12.557252Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:33:18.534Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:26:57.034Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-260914 | Tenda W30E WriteFacMac formWriteFacMac os command injection", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.260914" }, { "name": "VDB-260914 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.260914" }, { "name": "Submit #312823 | Tenda W30Ev1.0 V1.0.1.25(633) command injection", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.312823" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/formWriteFacMac.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "W30E", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0.1.25(633)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_mie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been found in Tenda W30E 1.0.1.25(633) and classified as critical. This vulnerability affects the function formWriteFacMac of the file /goform/WriteFacMac. The manipulation of the argument mac leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-260914 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda W30E 1.0.1.25(633) wurde eine kritische Schwachstelle gefunden. Hierbei betrifft es die Funktion formWriteFacMac der Datei /goform/WriteFacMac. Mittels dem Manipulieren des Arguments mac mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 6.3, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 6.5, "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-78", "description": "CWE-78 OS Command Injection", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-16T19:00:06.374Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-260914 | Tenda W30E WriteFacMac formWriteFacMac os command injection", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.260914" }, { "name": "VDB-260914 | CTI Indicators (IOB, IOC, TTP, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.260914" }, { "name": "Submit #312823 | Tenda W30Ev1.0 V1.0.1.25(633) command injection", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.312823" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/formWriteFacMac.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-16T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-16T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-16T12:55:04.000Z", "value": "VulDB entry last update" } ], "title": "Tenda W30E WriteFacMac formWriteFacMac os command injection" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-3880", "datePublished": "2024-04-16T19:00:06.374Z", "dateReserved": "2024-04-16T10:49:42.789Z", "dateUpdated": "2024-08-01T20:26:57.034Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45518
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:03.708Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/SetIpBind/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SetIpBind." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/SetIpBind/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45518", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:03.708Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45506
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:03.853Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/delFileName/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E v1.0.1.25(633) was discovered to contain a command injection vulnerability via the fileNameMit parameter at /goform/delFileName." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/delFileName/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45506", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:03.853Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-3879
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.260913 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.260913 | signature, permissions-required | |
https://vuldb.com/?submit.312822 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/formSetCfm.md | exploit |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T20:26:56.983Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-260913 | Tenda W30E setcfm formSetCfm stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.260913" }, { "name": "VDB-260913 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.260913" }, { "name": "Submit #312822 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.312822" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/formSetCfm.md" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\\(633\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "w30e_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.1.25\\(633\\)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-3879", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-08-19T17:33:22.591779Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-19T18:45:07.704Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "product": "W30E", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0.1.25(633)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_mie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine kritische Schwachstelle in Tenda W30E 1.0.1.25(633) gefunden. Dabei betrifft es die Funktion formSetCfm der Datei /goform/setcfm. Durch Manipulation des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-16T19:00:04.934Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-260913 | Tenda W30E setcfm formSetCfm stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.260913" }, { "name": "VDB-260913 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.260913" }, { "name": "Submit #312822 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.312822" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/formSetCfm.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-16T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-16T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-16T12:55:02.000Z", "value": "VulDB entry last update" } ], "title": "Tenda W30E setcfm formSetCfm stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-3879", "datePublished": "2024-04-16T19:00:04.934Z", "dateReserved": "2024-04-16T10:49:39.590Z", "dateUpdated": "2024-08-19T18:45:07.704Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49402
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:53:45.282Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_localMsg/w30e_localMsg.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function localMsg." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-07T16:53:32.131561", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_localMsg/w30e_localMsg.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-49402", "datePublished": "2023-12-07T00:00:00", "dateReserved": "2023-11-27T00:00:00", "dateUpdated": "2024-08-02T21:53:45.282Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49403
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:53:45.558Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_setFixTools/w30e_setFixTools.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V16.01.0.12(4843) was discovered to contain a command injection vulnerability via the function setFixTools." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-07T16:55:09.051962", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_setFixTools/w30e_setFixTools.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-49403", "datePublished": "2023-12-07T00:00:00", "dateReserved": "2023-11-27T00:00:00", "dateUpdated": "2024-08-02T21:53:45.558Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-50000
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T22:09:49.646Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_resetMesh/w30e_resetMesh.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formResetMeshNode." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-07T16:59:41.166991", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_resetMesh/w30e_resetMesh.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-50000", "datePublished": "2023-12-07T00:00:00", "dateReserved": "2023-12-04T00:00:00", "dateUpdated": "2024-08-02T22:09:49.646Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-50001
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T22:09:49.609Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_upgradeMeshOnline/w30e_upgradeMeshOnline.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formUpgradeMeshOnline." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-07T16:57:40.679679", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_upgradeMeshOnline/w30e_upgradeMeshOnline.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-50001", "datePublished": "2023-12-07T00:00:00", "dateReserved": "2023-12-04T00:00:00", "dateUpdated": "2024-08-02T22:09:49.609Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45525
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:03.838Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/CertListInfo/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the downaction parameter at /goform/CertListInfo." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/CertListInfo/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45525", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:03.838Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-3881
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.260915 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.260915 | signature, permissions-required | |
https://vuldb.com/?submit.312824 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/frmL7ProtForm.md | exploit |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "w30e", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.1.25\\/633\\/" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-3881", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-04-18T15:46:58.429046Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-03T15:34:42.267Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:26:56.424Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-260915 | Tenda W30E frmL7ProtForm frmL7PlotForm stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.260915" }, { "name": "VDB-260915 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.260915" }, { "name": "Submit #312824 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.312824" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/frmL7ProtForm.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "W30E", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0.1.25(633)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_mie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda W30E 1.0.1.25(633) and classified as critical. This issue affects the function frmL7PlotForm of the file /goform/frmL7ProtForm. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-260915. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda W30E 1.0.1.25(633) gefunden. Davon betroffen ist die Funktion frmL7PlotForm der Datei /goform/frmL7ProtForm. Mittels Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-16T19:31:04.202Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-260915 | Tenda W30E frmL7ProtForm frmL7PlotForm stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.260915" }, { "name": "VDB-260915 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.260915" }, { "name": "Submit #312824 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.312824" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/frmL7ProtForm.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-16T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-16T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-16T12:55:05.000Z", "value": "VulDB entry last update" } ], "title": "Tenda W30E frmL7ProtForm frmL7PlotForm stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-3881", "datePublished": "2024-04-16T19:31:04.202Z", "dateReserved": "2024-04-16T10:49:45.427Z", "dateUpdated": "2024-08-01T20:26:56.424Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-50002
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T22:09:49.570Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_rebootMesh/w30e_rebootMesh.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formRebootMeshNode." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-07T16:51:15.402232", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_rebootMesh/w30e_rebootMesh.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-50002", "datePublished": "2023-12-07T00:00:00", "dateReserved": "2023-12-04T00:00:00", "dateUpdated": "2024-08-02T22:09:49.570Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45505
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:03.494Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/exeCommand/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the cmdinput parameter at /goform/exeCommand." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/exeCommand/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45505", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:03.494Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49410
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:53:45.141Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_setIPv6Status/w30e_setIPv6Status.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function via the function set_wan_status." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-07T17:04:44.515196", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_setIPv6Status/w30e_setIPv6Status.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-49410", "datePublished": "2023-12-07T00:00:00", "dateReserved": "2023-11-27T00:00:00", "dateUpdated": "2024-08-02T21:53:45.141Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45513
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:03.936Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/P2pListFilter/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/P2pListFilter." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/P2pListFilter/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45513", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:03.936Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45514
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:03.896Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/webExcptypemanFilter/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/webExcptypemanFilter." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/webExcptypemanFilter/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45514", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:03.896Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-3882
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.260916 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.260916 | signature, permissions-required | |
https://vuldb.com/?submit.312825 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/fromRouteStatic.md | exploit |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\\(633\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "w30e_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.1.25\\(633\\)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-3882", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-07-09T16:18:28.401307Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-10T16:32:20.665Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:26:57.138Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-260916 | Tenda W30E fromRouteStatic stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.260916" }, { "name": "VDB-260916 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.260916" }, { "name": "Submit #312825 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.312825" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/fromRouteStatic.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "W30E", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0.1.25(633)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "wxhwxhwxh_mie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda W30E 1.0.1.25(633). It has been classified as critical. Affected is the function fromRouteStatic of the file /goform/fromRouteStatic. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260916. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine kritische Schwachstelle in Tenda W30E 1.0.1.25(633) ausgemacht. Hiervon betroffen ist die Funktion fromRouteStatic der Datei /goform/fromRouteStatic. Durch das Manipulieren des Arguments page mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-16T20:00:12.433Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-260916 | Tenda W30E fromRouteStatic stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.260916" }, { "name": "VDB-260916 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.260916" }, { "name": "Submit #312825 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.312825" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/fromRouteStatic.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-16T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-16T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-16T12:55:07.000Z", "value": "VulDB entry last update" } ], "title": "Tenda W30E fromRouteStatic stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-3882", "datePublished": "2024-04-16T20:00:12.433Z", "dateReserved": "2024-04-16T10:49:48.302Z", "dateUpdated": "2024-08-01T20:26:57.138Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-49404
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T21:53:44.993Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_setAdvancedSetList/w30e_setAdvancedSetList.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V16.01.0.12(4843) was discovered to contain a stack overflow via the function formAdvancedSetListSet." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2023-12-07T17:30:46.319323", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/GD008/TENDA/blob/main/w30e/tenda_w30e_setAdvancedSetList/w30e_setAdvancedSetList.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2023-49404", "datePublished": "2023-12-07T00:00:00", "dateReserved": "2023-11-27T00:00:00", "dateUpdated": "2024-08-02T21:53:44.993Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45522
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:03.931Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/SafeClientFilter/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeClientFilter." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/SafeClientFilter/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45522", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:03.931Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45512
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:03.512Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/SafeEmailFilter/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/SafeEmailFilter." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/SafeEmailFilter/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45512", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:03.512Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-45516
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T14:17:03.961Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/NatStaticSetting/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda W30E V1.0.1.25(633) was discovered to contain a stack overflow via the page parameter at /goform/NatStaticSetting." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-08T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/W30E/NatStaticSetting/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-45516", "datePublished": "2022-12-08T00:00:00", "dateReserved": "2022-11-21T00:00:00", "dateUpdated": "2024-08-03T14:17:03.961Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }