cve-2024-3879
Vulnerability from cvelistv5
Published
2024-04-16 19:00
Modified
2024-08-19 18:45
Summary
Tenda W30E setcfm formSetCfm stack-based overflow
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:26:56.983Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-260913 | Tenda W30E setcfm formSetCfm stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.260913"
          },
          {
            "name": "VDB-260913 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.260913"
          },
          {
            "name": "Submit #312822 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.312822"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/formSetCfm.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:w30e_firmware:1.0.1.25\\(633\\):*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "w30e_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.1.25\\(633\\)"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-3879",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-19T17:33:22.591779Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-19T18:45:07.704Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "W30E",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.1.25(633)"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda W30E 1.0.1.25(633) gefunden. Dabei betrifft es die Funktion formSetCfm der Datei /goform/setcfm. Durch Manipulation des Arguments funcpara1 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-16T19:00:04.934Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-260913 | Tenda W30E setcfm formSetCfm stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.260913"
        },
        {
          "name": "VDB-260913 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.260913"
        },
        {
          "name": "Submit #312822 | Tenda W30Ev1.0 V1.0.1.25(633) buffer overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.312822"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/formSetCfm.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-16T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-16T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-16T12:55:02.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda W30E setcfm formSetCfm stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-3879",
    "datePublished": "2024-04-16T19:00:04.934Z",
    "dateReserved": "2024-04-16T10:49:39.590Z",
    "dateUpdated": "2024-08-19T18:45:07.704Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-3879\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2024-04-16T19:15:08.133\",\"lastModified\":\"2024-05-17T02:40:10.177\",\"vulnStatus\":\"Awaiting Analysis\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability, which was classified as critical, was found in Tenda W30E 1.0.1.25(633). This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260913 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad fue encontrada en Tenda W30E 1.0.1.25(633) y clasificada como cr\u00edtica. Esto afecta a la funci\u00f3n formSetCfm del archivo /goform/setcfm. La manipulaci\u00f3n del argumento funcpara1 provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. Es posible iniciar el ataque de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. A esta vulnerabilidad se le asign\u00f3 el identificador VDB-260913. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\",\"baseScore\":9.0},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]}],\"references\":[{\"url\":\"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/formSetCfm.md\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?ctiid.260913\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?id.260913\",\"source\":\"cna@vuldb.com\"},{\"url\":\"https://vuldb.com/?submit.312822\",\"source\":\"cna@vuldb.com\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.