Search criteria
2 vulnerabilities found for WF2780 by Netis
CVE-2025-1617 (GCVE-0-2025-1617)
Vulnerability from cvelistv5 – Published: 2025-02-24 04:00 – Updated: 2025-02-24 12:59
VLAI?
Title
Netis WF2780 Wireless 2.4G Menu cross site scripting
Summary
A vulnerability, which was classified as problematic, was found in Netis WF2780 2.1.41925. This affects an unknown part of the component Wireless 2.4G Menu. The manipulation of the argument SSID leads to cross site scripting. It is possible to initiate the attack remotely. The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
Havook (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-1617",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-24T12:59:22.812095Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-24T12:59:28.476Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Wireless 2.4G Menu"
],
"product": "WF2780",
"vendor": "Netis",
"versions": [
{
"status": "affected",
"version": "2.1.41925"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Havook (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as problematic, was found in Netis WF2780 2.1.41925. This affects an unknown part of the component Wireless 2.4G Menu. The manipulation of the argument SSID leads to cross site scripting. It is possible to initiate the attack remotely. The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine problematische Schwachstelle in Netis WF2780 2.1.41925 gefunden. Es geht dabei um eine nicht klar definierte Funktion der Komponente Wireless 2.4G Menu. Durch die Manipulation des Arguments SSID mit unbekannten Daten kann eine cross site scripting-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 3.3,
"vectorString": "AV:N/AC:L/Au:M/C:N/I:P/A:N",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "Cross Site Scripting",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "Code Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-24T04:00:13.873Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-296607 | Netis WF2780 Wireless 2.4G Menu cross site scripting",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.296607"
},
{
"name": "VDB-296607 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.296607"
},
{
"name": "Submit #501472 | Netis WF2780 V2.1.41925 Cross Site Scripting",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.501472"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-02-23T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-02-23T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-02-23T10:47:59.000Z",
"value": "VulDB entry last update"
}
],
"title": "Netis WF2780 Wireless 2.4G Menu cross site scripting"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-1617",
"datePublished": "2025-02-24T04:00:13.873Z",
"dateReserved": "2025-02-23T09:42:39.912Z",
"dateUpdated": "2025-02-24T12:59:28.476Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-1617 (GCVE-0-2025-1617)
Vulnerability from nvd – Published: 2025-02-24 04:00 – Updated: 2025-02-24 12:59
VLAI?
Title
Netis WF2780 Wireless 2.4G Menu cross site scripting
Summary
A vulnerability, which was classified as problematic, was found in Netis WF2780 2.1.41925. This affects an unknown part of the component Wireless 2.4G Menu. The manipulation of the argument SSID leads to cross site scripting. It is possible to initiate the attack remotely. The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Credits
Havook (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-1617",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-24T12:59:22.812095Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-24T12:59:28.476Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"Wireless 2.4G Menu"
],
"product": "WF2780",
"vendor": "Netis",
"versions": [
{
"status": "affected",
"version": "2.1.41925"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Havook (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as problematic, was found in Netis WF2780 2.1.41925. This affects an unknown part of the component Wireless 2.4G Menu. The manipulation of the argument SSID leads to cross site scripting. It is possible to initiate the attack remotely. The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine problematische Schwachstelle in Netis WF2780 2.1.41925 gefunden. Es geht dabei um eine nicht klar definierte Funktion der Komponente Wireless 2.4G Menu. Durch die Manipulation des Arguments SSID mit unbekannten Daten kann eine cross site scripting-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 2.4,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:L/A:N",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 3.3,
"vectorString": "AV:N/AC:L/Au:M/C:N/I:P/A:N",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "Cross Site Scripting",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "Code Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-24T04:00:13.873Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-296607 | Netis WF2780 Wireless 2.4G Menu cross site scripting",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.296607"
},
{
"name": "VDB-296607 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.296607"
},
{
"name": "Submit #501472 | Netis WF2780 V2.1.41925 Cross Site Scripting",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.501472"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-02-23T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-02-23T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-02-23T10:47:59.000Z",
"value": "VulDB entry last update"
}
],
"title": "Netis WF2780 Wireless 2.4G Menu cross site scripting"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-1617",
"datePublished": "2025-02-24T04:00:13.873Z",
"dateReserved": "2025-02-23T09:42:39.912Z",
"dateUpdated": "2025-02-24T12:59:28.476Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}