Search criteria
2 vulnerabilities found for Wireless 5932e by Dell
CVE-2025-43993 (GCVE-0-2025-43993)
Vulnerability from cvelistv5 – Published: 2025-09-25 19:38 – Updated: 2025-09-26 17:39
VLAI?
Summary
Dell Wireless 5932e and Qualcomm Snapdragon X62 Firmware and GNSS/GPS Driver, versions prior to 3.2.0.22 contain an Unquoted Search Path or Element vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code Execution.
Severity ?
7.8 (High)
CWE
- CWE-428 - Unquoted Search Path or Element
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Wireless 5932e |
Affected:
N/A , < 3.2.0.22
(semver)
|
Credits
Dell Technologies would like to thank Noah Settmacher from HanseSecure for reporting this issue.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-43993",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-26T17:39:41.841081Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-26T17:39:48.405Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Wireless 5932e",
"vendor": "Dell",
"versions": [
{
"lessThan": "3.2.0.22",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell Technologies would like to thank Noah Settmacher from HanseSecure for reporting this issue."
}
],
"datePublic": "2025-09-25T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Wireless 5932e and Qualcomm Snapdragon X62 Firmware and GNSS/GPS Driver, versions prior to 3.2.0.22 contain an Unquoted Search Path or Element vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code Execution."
}
],
"value": "Dell Wireless 5932e and Qualcomm Snapdragon X62 Firmware and GNSS/GPS Driver, versions prior to 3.2.0.22 contain an Unquoted Search Path or Element vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code Execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "CWE-428: Unquoted Search Path or Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-25T19:38:00.845Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000372605/dsa-2025-363"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2025-43993",
"datePublished": "2025-09-25T19:38:00.845Z",
"dateReserved": "2025-04-21T05:03:43.635Z",
"dateUpdated": "2025-09-26T17:39:48.405Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-43993 (GCVE-0-2025-43993)
Vulnerability from nvd – Published: 2025-09-25 19:38 – Updated: 2025-09-26 17:39
VLAI?
Summary
Dell Wireless 5932e and Qualcomm Snapdragon X62 Firmware and GNSS/GPS Driver, versions prior to 3.2.0.22 contain an Unquoted Search Path or Element vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code Execution.
Severity ?
7.8 (High)
CWE
- CWE-428 - Unquoted Search Path or Element
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Wireless 5932e |
Affected:
N/A , < 3.2.0.22
(semver)
|
Credits
Dell Technologies would like to thank Noah Settmacher from HanseSecure for reporting this issue.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-43993",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-26T17:39:41.841081Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-26T17:39:48.405Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Wireless 5932e",
"vendor": "Dell",
"versions": [
{
"lessThan": "3.2.0.22",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Dell Technologies would like to thank Noah Settmacher from HanseSecure for reporting this issue."
}
],
"datePublic": "2025-09-25T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Wireless 5932e and Qualcomm Snapdragon X62 Firmware and GNSS/GPS Driver, versions prior to 3.2.0.22 contain an Unquoted Search Path or Element vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code Execution."
}
],
"value": "Dell Wireless 5932e and Qualcomm Snapdragon X62 Firmware and GNSS/GPS Driver, versions prior to 3.2.0.22 contain an Unquoted Search Path or Element vulnerability. A low privileged attacker with local access could potentially exploit this vulnerability, leading to Code Execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "CWE-428: Unquoted Search Path or Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-25T19:38:00.845Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000372605/dsa-2025-363"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2025-43993",
"datePublished": "2025-09-25T19:38:00.845Z",
"dateReserved": "2025-04-21T05:03:43.635Z",
"dateUpdated": "2025-09-26T17:39:48.405Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}