Search criteria
24 vulnerabilities found for a18_firmware by tenda
FKIE_CVE-2025-0848
Vulnerability from fkie_nvd - Published: 2025-01-30 02:15 - Updated: 2025-03-06 13:59
Severity ?
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability was found in Tenda A18 up to 15.13.07.09. It has been rated as critical. This issue affects the function SetCmdlineRun of the file /goform/SetCmdlineRun of the component HTTP POST Request Handler. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
References
| URL | Tags | ||
|---|---|---|---|
| cna@vuldb.com | https://github.com/alc9700jmo/CVE/issues/9 | Exploit, Third Party Advisory | |
| cna@vuldb.com | https://vuldb.com/?ctiid.294011 | Permissions Required, VDB Entry | |
| cna@vuldb.com | https://vuldb.com/?id.294011 | Third Party Advisory, VDB Entry | |
| cna@vuldb.com | https://vuldb.com/?submit.485802 | Third Party Advisory, VDB Entry | |
| cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | a18_firmware | 15.13.07.09 | |
| tenda | a18 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:a18_firmware:15.13.07.09:*:*:*:*:*:*:*",
"matchCriteriaId": "0916A698-E859-4DA2-899C-5A55B68E25F1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*",
"matchCriteriaId": "20146A03-30B3-4BFF-83DA-DEDBF6850A6B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda A18 up to 15.13.07.09. It has been rated as critical. This issue affects the function SetCmdlineRun of the file /goform/SetCmdlineRun of the component HTTP POST Request Handler. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "es",
"value": "Se ha detectado una vulnerabilidad en Tenda A18 hasta el 15.13.07.09. Se ha calificado como cr\u00edtica. Este problema afecta a la funci\u00f3n SetCmdlineRun del archivo /goform/SetCmdlineRun del componente HTTP POST Request Handler. La manipulaci\u00f3n del argumento wpapsk_crypto5g provoca un desbordamiento del b\u00fafer basado en la pila. El ataque puede iniciarse de forma remota. El exploit se ha hecho p\u00fablico y puede utilizarse."
}
],
"id": "CVE-2025-0848",
"lastModified": "2025-03-06T13:59:01.170",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 6.8,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "cna@vuldb.com",
"type": "Secondary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "cna@vuldb.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "cna@vuldb.com",
"type": "Secondary"
}
]
},
"published": "2025-01-30T02:15:25.597",
"references": [
{
"source": "cna@vuldb.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/alc9700jmo/CVE/issues/9"
},
{
"source": "cna@vuldb.com",
"tags": [
"Permissions Required",
"VDB Entry"
],
"url": "https://vuldb.com/?ctiid.294011"
},
{
"source": "cna@vuldb.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?id.294011"
},
{
"source": "cna@vuldb.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?submit.485802"
},
{
"source": "cna@vuldb.com",
"tags": [
"Product"
],
"url": "https://www.tenda.com.cn/"
}
],
"sourceIdentifier": "cna@vuldb.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
},
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "cna@vuldb.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-32305
Vulnerability from fkie_nvd - Published: 2024-04-17 16:15 - Updated: 2025-04-09 14:20
Severity ?
Summary
Tenda A18 v15.03.05.05 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | a18_firmware | 15.03.05.05 | |
| tenda | a18 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:a18_firmware:15.03.05.05:*:*:*:*:*:*:*",
"matchCriteriaId": "C2898C97-F985-46B7-A2AE-CE0C4DBB3F19",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*",
"matchCriteriaId": "20146A03-30B3-4BFF-83DA-DEDBF6850A6B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda A18 v15.03.05.05 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function."
},
{
"lang": "es",
"value": "El firmware Tenda A18 v15.03.05.05 tiene una vulnerabilidad de desbordamiento de pila ubicada a trav\u00e9s del par\u00e1metro PPW en la funci\u00f3n fromWizardHandle."
}
],
"id": "CVE-2024-32305",
"lastModified": "2025-04-09T14:20:39.827",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-04-17T16:15:08.893",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Broken Link"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/fromWizardHandle.md"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Broken Link"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/fromWizardHandle.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-50585
Vulnerability from fkie_nvd - Published: 2024-01-09 09:15 - Updated: 2025-06-03 15:15
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | a18_firmware | 15.13.07.09 | |
| tenda | a18 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:a18_firmware:15.13.07.09:*:*:*:*:*:*:*",
"matchCriteriaId": "0916A698-E859-4DA2-899C-5A55B68E25F1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*",
"matchCriteriaId": "20146A03-30B3-4BFF-83DA-DEDBF6850A6B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function."
},
{
"lang": "es",
"value": "Se descubri\u00f3 que Tenda A18 v15.13.07.09 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro devName en la funci\u00f3n formSetDeviceName."
}
],
"id": "CVE-2023-50585",
"lastModified": "2025-06-03T15:15:46.043",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-01-09T09:15:42.430",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2023-39827
Vulnerability from fkie_nvd - Published: 2023-08-14 21:15 - Updated: 2024-11-21 08:15
Severity ?
Summary
Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the rule_info parameter in the formAddMacfilterRule function.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formAddMacfilterRule | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formAddMacfilterRule | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | a18_firmware | 15.13.07.09 | |
| tenda | a18 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:a18_firmware:15.13.07.09:*:*:*:*:*:*:*",
"matchCriteriaId": "0916A698-E859-4DA2-899C-5A55B68E25F1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*",
"matchCriteriaId": "20146A03-30B3-4BFF-83DA-DEDBF6850A6B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the rule_info parameter in the formAddMacfilterRule function."
}
],
"id": "CVE-2023-39827",
"lastModified": "2024-11-21T08:15:58.283",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-08-14T21:15:13.030",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formAddMacfilterRule"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formAddMacfilterRule"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-39829
Vulnerability from fkie_nvd - Published: 2023-08-14 21:15 - Updated: 2024-11-21 08:15
Severity ?
Summary
Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the wpapsk_crypto2_4g parameter in the fromSetWirelessRepeat function.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/fromSetWirelessRepeat | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/fromSetWirelessRepeat | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | a18_firmware | 15.13.07.09 | |
| tenda | a18 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:a18_firmware:15.13.07.09:*:*:*:*:*:*:*",
"matchCriteriaId": "0916A698-E859-4DA2-899C-5A55B68E25F1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*",
"matchCriteriaId": "20146A03-30B3-4BFF-83DA-DEDBF6850A6B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the wpapsk_crypto2_4g parameter in the fromSetWirelessRepeat function."
}
],
"id": "CVE-2023-39829",
"lastModified": "2024-11-21T08:15:58.597",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-08-14T21:15:13.367",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/fromSetWirelessRepeat"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/fromSetWirelessRepeat"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2023-39828
Vulnerability from fkie_nvd - Published: 2023-08-14 21:15 - Updated: 2024-11-21 08:15
Severity ?
Summary
Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formWifiBasicSet | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formWifiBasicSet | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | a18_firmware | 15.13.07.09 | |
| tenda | a18 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:a18_firmware:15.13.07.09:*:*:*:*:*:*:*",
"matchCriteriaId": "0916A698-E859-4DA2-899C-5A55B68E25F1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*",
"matchCriteriaId": "20146A03-30B3-4BFF-83DA-DEDBF6850A6B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function."
}
],
"id": "CVE-2023-39828",
"lastModified": "2024-11-21T08:15:58.443",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-08-14T21:15:13.197",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formWifiBasicSet"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formWifiBasicSet"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2022-44932
Vulnerability from fkie_nvd - Published: 2022-12-08 16:15 - Updated: 2025-04-23 16:15
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
Summary
An access control issue in Tenda A18 v15.13.07.09 allows unauthenticated attackers to access the Telnet service.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/TendaTelnet/readme.md | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/TendaTelnet/readme.md | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | a18_firmware | 15.13.07.09 | |
| tenda | a18 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:a18_firmware:15.13.07.09:*:*:*:*:*:*:*",
"matchCriteriaId": "0916A698-E859-4DA2-899C-5A55B68E25F1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*",
"matchCriteriaId": "20146A03-30B3-4BFF-83DA-DEDBF6850A6B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An access control issue in Tenda A18 v15.13.07.09 allows unauthenticated attackers to access the Telnet service."
},
{
"lang": "es",
"value": "Un problema de control de acceso en Tenda A18 v15.13.07.09 permite a atacantes no autenticados acceder al servicio Telnet."
}
],
"id": "CVE-2022-44932",
"lastModified": "2025-04-23T16:15:27.143",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2022-12-08T16:15:13.510",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/TendaTelnet/readme.md"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/TendaTelnet/readme.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-284"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2022-44931
Vulnerability from fkie_nvd - Published: 2022-12-08 16:15 - Updated: 2025-04-23 16:15
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the security_5g parameter at /goform/WifiBasicSet.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/formWifiBasicSet/readme.md | Exploit, Patch, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/formWifiBasicSet/readme.md | Exploit, Patch, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | a18_firmware | 15.13.07.09 | |
| tenda | a18 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:a18_firmware:15.13.07.09:*:*:*:*:*:*:*",
"matchCriteriaId": "0916A698-E859-4DA2-899C-5A55B68E25F1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*",
"matchCriteriaId": "20146A03-30B3-4BFF-83DA-DEDBF6850A6B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the security_5g parameter at /goform/WifiBasicSet."
},
{
"lang": "es",
"value": "Se descubri\u00f3 que Tenda A18 v15.13.07.09 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro security_5g en /goform/WifiBasicSet."
}
],
"id": "CVE-2022-44931",
"lastModified": "2025-04-23T16:15:26.960",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2022-12-08T16:15:13.470",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Patch",
"Third Party Advisory"
],
"url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/formWifiBasicSet/readme.md"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Patch",
"Third Party Advisory"
],
"url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/formWifiBasicSet/readme.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
CVE-2025-0848 (GCVE-0-2025-0848)
Vulnerability from cvelistv5 – Published: 2025-01-30 01:00 – Updated: 2025-01-30 15:12
VLAI?
Title
Tenda A18 HTTP POST Request SetCmdlineRun stack-based overflow
Summary
A vulnerability was found in Tenda A18 up to 15.13.07.09. It has been rated as critical. This issue affects the function SetCmdlineRun of the file /goform/SetCmdlineRun of the component HTTP POST Request Handler. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity ?
6.5 (Medium)
6.5 (Medium)
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
alc9700 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-0848",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-30T15:12:54.599269Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-30T15:12:59.662Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"HTTP POST Request Handler"
],
"product": "A18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.13.07.09"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "alc9700 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda A18 up to 15.13.07.09. It has been rated as critical. This issue affects the function SetCmdlineRun of the file /goform/SetCmdlineRun of the component HTTP POST Request Handler. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda A18 bis 15.13.07.09 ausgemacht. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion SetCmdlineRun der Datei /goform/SetCmdlineRun der Komponente HTTP POST Request Handler. Durch die Manipulation des Arguments wpapsk_crypto5g mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.8,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-30T01:00:19.576Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-294011 | Tenda A18 HTTP POST Request SetCmdlineRun stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.294011"
},
{
"name": "VDB-294011 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.294011"
},
{
"name": "Submit #485802 | Tenda Tenda A18 V15.13.07.09 V15.13.07.09 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.485802"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/alc9700jmo/CVE/issues/9"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-01-29T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-01-29T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-01-29T18:14:31.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda A18 HTTP POST Request SetCmdlineRun stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-0848",
"datePublished": "2025-01-30T01:00:19.576Z",
"dateReserved": "2025-01-29T17:09:28.802Z",
"dateUpdated": "2025-01-30T15:12:59.662Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32305 (GCVE-0-2024-32305)
Vulnerability from cvelistv5 – Published: 2024-04-17 00:00 – Updated: 2024-11-06 15:34
VLAI?
Summary
Tenda A18 v15.03.05.05 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
Severity ?
8.8 (High)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:a18_firmware:15.03.05.05:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "a18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-32305",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-06T15:34:21.018925Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-06T15:34:24.417Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:06:44.205Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/fromWizardHandle.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda A18 v15.03.05.05 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-17T15:40:16.012526",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/fromWizardHandle.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-32305",
"datePublished": "2024-04-17T00:00:00",
"dateReserved": "2024-04-12T00:00:00",
"dateUpdated": "2024-11-06T15:34:24.417Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-50585 (GCVE-0-2023-50585)
Vulnerability from cvelistv5 – Published: 2024-01-09 00:00 – Updated: 2025-06-03 14:34
VLAI?
Summary
Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:16:47.203Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-50585",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-08T16:00:01.273922Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-03T14:34:10.536Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T08:13:03.708Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-50585",
"datePublished": "2024-01-09T00:00:00.000Z",
"dateReserved": "2023-12-11T00:00:00.000Z",
"dateUpdated": "2025-06-03T14:34:10.536Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-39827 (GCVE-0-2023-39827)
Vulnerability from cvelistv5 – Published: 2023-08-14 00:00 – Updated: 2024-10-09 15:51
VLAI?
Summary
Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the rule_info parameter in the formAddMacfilterRule function.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T18:18:09.831Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formAddMacfilterRule"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "a18",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "V15.13.07.09"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-39827",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T15:50:21.641738Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T15:51:41.730Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the rule_info parameter in the formAddMacfilterRule function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-14T00:00:00",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formAddMacfilterRule"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-39827",
"datePublished": "2023-08-14T00:00:00",
"dateReserved": "2023-08-07T00:00:00",
"dateUpdated": "2024-10-09T15:51:41.730Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-39828 (GCVE-0-2023-39828)
Vulnerability from cvelistv5 – Published: 2023-08-14 00:00 – Updated: 2024-10-09 15:07
VLAI?
Summary
Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T18:18:10.052Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formWifiBasicSet"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "a18",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "v15.13.07.09"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-39828",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T15:07:04.245313Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T15:07:39.636Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-14T00:00:00",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formWifiBasicSet"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-39828",
"datePublished": "2023-08-14T00:00:00",
"dateReserved": "2023-08-07T00:00:00",
"dateUpdated": "2024-10-09T15:07:39.636Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-39829 (GCVE-0-2023-39829)
Vulnerability from cvelistv5 – Published: 2023-08-14 00:00 – Updated: 2024-10-09 15:06
VLAI?
Summary
Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the wpapsk_crypto2_4g parameter in the fromSetWirelessRepeat function.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T18:18:09.781Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/fromSetWirelessRepeat"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "a18",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "v15.13.07.09"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-39829",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T15:05:51.396837Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T15:06:32.724Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the wpapsk_crypto2_4g parameter in the fromSetWirelessRepeat function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-14T00:00:00",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/fromSetWirelessRepeat"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-39829",
"datePublished": "2023-08-14T00:00:00",
"dateReserved": "2023-08-07T00:00:00",
"dateUpdated": "2024-10-09T15:06:32.724Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-44932 (GCVE-0-2022-44932)
Vulnerability from cvelistv5 – Published: 2022-12-08 00:00 – Updated: 2025-04-23 15:10
VLAI?
Summary
An access control issue in Tenda A18 v15.13.07.09 allows unauthenticated attackers to access the Telnet service.
Severity ?
7.5 (High)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.343Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/TendaTelnet/readme.md"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-44932",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T15:09:49.893625Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-23T15:10:40.247Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An access control issue in Tenda A18 v15.13.07.09 allows unauthenticated attackers to access the Telnet service."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-08T00:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/TendaTelnet/readme.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-44932",
"datePublished": "2022-12-08T00:00:00.000Z",
"dateReserved": "2022-11-07T00:00:00.000Z",
"dateUpdated": "2025-04-23T15:10:40.247Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-44931 (GCVE-0-2022-44931)
Vulnerability from cvelistv5 – Published: 2022-12-08 00:00 – Updated: 2025-04-23 15:11
VLAI?
Summary
Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the security_5g parameter at /goform/WifiBasicSet.
Severity ?
7.5 (High)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.396Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/formWifiBasicSet/readme.md"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-44931",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T15:11:08.240199Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-23T15:11:13.068Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the security_5g parameter at /goform/WifiBasicSet."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-08T00:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/formWifiBasicSet/readme.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-44931",
"datePublished": "2022-12-08T00:00:00.000Z",
"dateReserved": "2022-11-07T00:00:00.000Z",
"dateUpdated": "2025-04-23T15:11:13.068Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-0848 (GCVE-0-2025-0848)
Vulnerability from nvd – Published: 2025-01-30 01:00 – Updated: 2025-01-30 15:12
VLAI?
Title
Tenda A18 HTTP POST Request SetCmdlineRun stack-based overflow
Summary
A vulnerability was found in Tenda A18 up to 15.13.07.09. It has been rated as critical. This issue affects the function SetCmdlineRun of the file /goform/SetCmdlineRun of the component HTTP POST Request Handler. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
Severity ?
6.5 (Medium)
6.5 (Medium)
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
alc9700 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-0848",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-30T15:12:54.599269Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-30T15:12:59.662Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"HTTP POST Request Handler"
],
"product": "A18",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.13.07.09"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "alc9700 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda A18 up to 15.13.07.09. It has been rated as critical. This issue affects the function SetCmdlineRun of the file /goform/SetCmdlineRun of the component HTTP POST Request Handler. The manipulation of the argument wpapsk_crypto5g leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda A18 bis 15.13.07.09 ausgemacht. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion SetCmdlineRun der Datei /goform/SetCmdlineRun der Komponente HTTP POST Request Handler. Durch die Manipulation des Arguments wpapsk_crypto5g mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.8,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-30T01:00:19.576Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-294011 | Tenda A18 HTTP POST Request SetCmdlineRun stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.294011"
},
{
"name": "VDB-294011 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.294011"
},
{
"name": "Submit #485802 | Tenda Tenda A18 V15.13.07.09 V15.13.07.09 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.485802"
},
{
"tags": [
"exploit",
"issue-tracking"
],
"url": "https://github.com/alc9700jmo/CVE/issues/9"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-01-29T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-01-29T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-01-29T18:14:31.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda A18 HTTP POST Request SetCmdlineRun stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-0848",
"datePublished": "2025-01-30T01:00:19.576Z",
"dateReserved": "2025-01-29T17:09:28.802Z",
"dateUpdated": "2025-01-30T15:12:59.662Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-32305 (GCVE-0-2024-32305)
Vulnerability from nvd – Published: 2024-04-17 00:00 – Updated: 2024-11-06 15:34
VLAI?
Summary
Tenda A18 v15.03.05.05 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function.
Severity ?
8.8 (High)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:a18_firmware:15.03.05.05:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "a18_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "15.03.05.05"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-32305",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-06T15:34:21.018925Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-06T15:34:24.417Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:06:44.205Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/fromWizardHandle.md"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda A18 v15.03.05.05 firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-17T15:40:16.012526",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/fromWizardHandle.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-32305",
"datePublished": "2024-04-17T00:00:00",
"dateReserved": "2024-04-12T00:00:00",
"dateUpdated": "2024-11-06T15:34:24.417Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-50585 (GCVE-0-2023-50585)
Vulnerability from nvd – Published: 2024-01-09 00:00 – Updated: 2025-06-03 14:34
VLAI?
Summary
Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function.
Severity ?
9.8 (Critical)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T22:16:47.203Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-50585",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-08T16:00:01.273922Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-03T14:34:10.536Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T08:13:03.708Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/LaPhilosophie/IoT-vulnerable/blob/main/Tenda/A18/formSetDeviceName.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-50585",
"datePublished": "2024-01-09T00:00:00.000Z",
"dateReserved": "2023-12-11T00:00:00.000Z",
"dateUpdated": "2025-06-03T14:34:10.536Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-39827 (GCVE-0-2023-39827)
Vulnerability from nvd – Published: 2023-08-14 00:00 – Updated: 2024-10-09 15:51
VLAI?
Summary
Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the rule_info parameter in the formAddMacfilterRule function.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T18:18:09.831Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formAddMacfilterRule"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "a18",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "V15.13.07.09"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-39827",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T15:50:21.641738Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T15:51:41.730Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the rule_info parameter in the formAddMacfilterRule function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-14T00:00:00",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formAddMacfilterRule"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-39827",
"datePublished": "2023-08-14T00:00:00",
"dateReserved": "2023-08-07T00:00:00",
"dateUpdated": "2024-10-09T15:51:41.730Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-39828 (GCVE-0-2023-39828)
Vulnerability from nvd – Published: 2023-08-14 00:00 – Updated: 2024-10-09 15:07
VLAI?
Summary
Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T18:18:10.052Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formWifiBasicSet"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "a18",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "v15.13.07.09"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-39828",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T15:07:04.245313Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T15:07:39.636Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the security parameter in the formWifiBasicSet function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-14T00:00:00",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/formWifiBasicSet"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-39828",
"datePublished": "2023-08-14T00:00:00",
"dateReserved": "2023-08-07T00:00:00",
"dateUpdated": "2024-10-09T15:07:39.636Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-39829 (GCVE-0-2023-39829)
Vulnerability from nvd – Published: 2023-08-14 00:00 – Updated: 2024-10-09 15:06
VLAI?
Summary
Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the wpapsk_crypto2_4g parameter in the fromSetWirelessRepeat function.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T18:18:09.781Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/fromSetWirelessRepeat"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:tenda:a18:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "a18",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "v15.13.07.09"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-39829",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-09T15:05:51.396837Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-09T15:06:32.724Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda A18 V15.13.07.09 was discovered to contain a stack overflow via the wpapsk_crypto2_4g parameter in the fromSetWirelessRepeat function."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-14T00:00:00",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/lst-oss/Vulnerability/tree/main/Tenda/A18/fromSetWirelessRepeat"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-39829",
"datePublished": "2023-08-14T00:00:00",
"dateReserved": "2023-08-07T00:00:00",
"dateUpdated": "2024-10-09T15:06:32.724Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-44932 (GCVE-0-2022-44932)
Vulnerability from nvd – Published: 2022-12-08 00:00 – Updated: 2025-04-23 15:10
VLAI?
Summary
An access control issue in Tenda A18 v15.13.07.09 allows unauthenticated attackers to access the Telnet service.
Severity ?
7.5 (High)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.343Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/TendaTelnet/readme.md"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-44932",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T15:09:49.893625Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-23T15:10:40.247Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An access control issue in Tenda A18 v15.13.07.09 allows unauthenticated attackers to access the Telnet service."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-08T00:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/TendaTelnet/readme.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-44932",
"datePublished": "2022-12-08T00:00:00.000Z",
"dateReserved": "2022-11-07T00:00:00.000Z",
"dateUpdated": "2025-04-23T15:10:40.247Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-44931 (GCVE-0-2022-44931)
Vulnerability from nvd – Published: 2022-12-08 00:00 – Updated: 2025-04-23 15:11
VLAI?
Summary
Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the security_5g parameter at /goform/WifiBasicSet.
Severity ?
7.5 (High)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T14:01:31.396Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/formWifiBasicSet/readme.md"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-44931",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T15:11:08.240199Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-23T15:11:13.068Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda A18 v15.13.07.09 was discovered to contain a stack overflow via the security_5g parameter at /goform/WifiBasicSet."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-08T00:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/z1r00/IOT_Vul/blob/main/Tenda/A18/formWifiBasicSet/readme.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-44931",
"datePublished": "2022-12-08T00:00:00.000Z",
"dateReserved": "2022-11-07T00:00:00.000Z",
"dateUpdated": "2025-04-23T15:11:13.068Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}