Search criteria

41 vulnerabilities found for ac23 by tenda

CVE-2025-12596 (GCVE-0-2025-12596)

Vulnerability from cvelistv5 – Published: 2025-11-02 10:32 – Updated: 2025-11-03 14:54
VLAI?
Title
Tenda AC23 saveParentControlInfo buffer overflow
Summary
A security vulnerability has been detected in Tenda AC23 16.03.07.52. Affected is the function saveParentControlInfo of the file /goform/saveParentControlInfo. Such manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed publicly and may be used.
CWE
Assigner
References
https://vuldb.com/?id.330891 vdb-entrytechnical-description
https://vuldb.com/?ctiid.330891 signaturepermissions-required
https://vuldb.com/?submit.677585 third-party-advisory
https://github.com/LX-LX88/cve/issues/9 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC23 Affected: 16.03.07.52
Create a notification for this product.
Credits
LX-LX (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12596",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-03T14:54:36.500458Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-03T14:54:39.493Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/LX-LX88/cve/issues/9"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC23",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.07.52"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LX-LX (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security vulnerability has been detected in Tenda AC23 16.03.07.52. Affected is the function saveParentControlInfo of the file /goform/saveParentControlInfo. Such manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed publicly and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC23 16.03.07.52 ist eine Schwachstelle entdeckt worden. Betroffen ist die Funktion saveParentControlInfo der Datei /goform/saveParentControlInfo. Dank Manipulation des Arguments Time mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Ein Angriff ist aus der Distanz m\u00f6glich. Der Exploit wurde der \u00d6ffentlichkeit bekannt gemacht und k\u00f6nnte verwendet werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-02T10:32:06.299Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-330891 | Tenda AC23 saveParentControlInfo buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.330891"
        },
        {
          "name": "VDB-330891 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.330891"
        },
        {
          "name": "Submit #677585 | Tenda AC23 V16.03.07.52 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.677585"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/LX-LX88/cve/issues/9"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-11-01T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-11-01T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-11-01T18:26:28.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC23 saveParentControlInfo buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-12596",
    "datePublished": "2025-11-02T10:32:06.299Z",
    "dateReserved": "2025-11-01T17:21:21.802Z",
    "dateUpdated": "2025-11-03T14:54:39.493Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-12595 (GCVE-0-2025-12595)

Vulnerability from cvelistv5 – Published: 2025-11-02 10:02 – Updated: 2025-11-03 14:55
VLAI?
Title
Tenda AC23 SetVirtualServerCfg formSetVirtualSer buffer overflow
Summary
A weakness has been identified in Tenda AC23 16.03.07.52. This impacts the function formSetVirtualSer of the file /goform/SetVirtualServerCfg. This manipulation of the argument list causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been made available to the public and could be exploited.
CWE
Assigner
References
https://vuldb.com/?id.330890 vdb-entrytechnical-description
https://vuldb.com/?ctiid.330890 signaturepermissions-required
https://vuldb.com/?submit.677581 third-party-advisory
https://github.com/LX-LX88/cve/issues/8 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC23 Affected: 16.03.07.52
Create a notification for this product.
Credits
LX-LX (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12595",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-03T14:55:44.673004Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-03T14:55:49.338Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/LX-LX88/cve/issues/8"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC23",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.07.52"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LX-LX (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A weakness has been identified in Tenda AC23 16.03.07.52. This impacts the function formSetVirtualSer of the file /goform/SetVirtualServerCfg. This manipulation of the argument list causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been made available to the public and could be exploited."
        },
        {
          "lang": "de",
          "value": "In Tenda AC23 16.03.07.52 wurde eine Schwachstelle gefunden. Hierbei geht es um die Funktion formSetVirtualSer der Datei /goform/SetVirtualServerCfg. Dank der Manipulation des Arguments list mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-02T10:02:07.134Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-330890 | Tenda AC23 SetVirtualServerCfg formSetVirtualSer buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.330890"
        },
        {
          "name": "VDB-330890 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.330890"
        },
        {
          "name": "Submit #677581 | Tenda AC23 V16.03.07.52 Buffer Over",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.677581"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/LX-LX88/cve/issues/8"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-11-01T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-11-01T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-11-01T18:26:26.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC23 SetVirtualServerCfg formSetVirtualSer buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-12595",
    "datePublished": "2025-11-02T10:02:07.134Z",
    "dateReserved": "2025-11-01T17:21:18.934Z",
    "dateUpdated": "2025-11-03T14:55:49.338Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-11356 (GCVE-0-2025-11356)

Vulnerability from cvelistv5 – Published: 2025-10-07 07:02 – Updated: 2025-10-07 18:13
VLAI?
Title
Tenda AC23 SetStaticRouteCfg sscanf buffer overflow
Summary
A vulnerability was found in Tenda AC23 up to 16.03.07.52. Affected by this issue is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. It is possible to launch the attack remotely. The exploit has been made public and could be used.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC23 Affected: 16.03.07.0
Affected: 16.03.07.1
Affected: 16.03.07.2
Affected: 16.03.07.3
Affected: 16.03.07.4
Affected: 16.03.07.5
Affected: 16.03.07.6
Affected: 16.03.07.7
Affected: 16.03.07.8
Affected: 16.03.07.9
Affected: 16.03.07.10
Affected: 16.03.07.11
Affected: 16.03.07.12
Affected: 16.03.07.13
Affected: 16.03.07.14
Affected: 16.03.07.15
Affected: 16.03.07.16
Affected: 16.03.07.17
Affected: 16.03.07.18
Affected: 16.03.07.19
Affected: 16.03.07.20
Affected: 16.03.07.21
Affected: 16.03.07.22
Affected: 16.03.07.23
Affected: 16.03.07.24
Affected: 16.03.07.25
Affected: 16.03.07.26
Affected: 16.03.07.27
Affected: 16.03.07.28
Affected: 16.03.07.29
Affected: 16.03.07.30
Affected: 16.03.07.31
Affected: 16.03.07.32
Affected: 16.03.07.33
Affected: 16.03.07.34
Affected: 16.03.07.35
Affected: 16.03.07.36
Affected: 16.03.07.37
Affected: 16.03.07.38
Affected: 16.03.07.39
Affected: 16.03.07.40
Affected: 16.03.07.41
Affected: 16.03.07.42
Affected: 16.03.07.43
Affected: 16.03.07.44
Affected: 16.03.07.45
Affected: 16.03.07.46
Affected: 16.03.07.47
Affected: 16.03.07.48
Affected: 16.03.07.49
Affected: 16.03.07.50
Affected: 16.03.07.51
Affected: 16.03.07.52
Create a notification for this product.
Credits
cymiao (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11356",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-07T18:13:29.018317Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-07T18:13:39.826Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC23",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.07.0"
            },
            {
              "status": "affected",
              "version": "16.03.07.1"
            },
            {
              "status": "affected",
              "version": "16.03.07.2"
            },
            {
              "status": "affected",
              "version": "16.03.07.3"
            },
            {
              "status": "affected",
              "version": "16.03.07.4"
            },
            {
              "status": "affected",
              "version": "16.03.07.5"
            },
            {
              "status": "affected",
              "version": "16.03.07.6"
            },
            {
              "status": "affected",
              "version": "16.03.07.7"
            },
            {
              "status": "affected",
              "version": "16.03.07.8"
            },
            {
              "status": "affected",
              "version": "16.03.07.9"
            },
            {
              "status": "affected",
              "version": "16.03.07.10"
            },
            {
              "status": "affected",
              "version": "16.03.07.11"
            },
            {
              "status": "affected",
              "version": "16.03.07.12"
            },
            {
              "status": "affected",
              "version": "16.03.07.13"
            },
            {
              "status": "affected",
              "version": "16.03.07.14"
            },
            {
              "status": "affected",
              "version": "16.03.07.15"
            },
            {
              "status": "affected",
              "version": "16.03.07.16"
            },
            {
              "status": "affected",
              "version": "16.03.07.17"
            },
            {
              "status": "affected",
              "version": "16.03.07.18"
            },
            {
              "status": "affected",
              "version": "16.03.07.19"
            },
            {
              "status": "affected",
              "version": "16.03.07.20"
            },
            {
              "status": "affected",
              "version": "16.03.07.21"
            },
            {
              "status": "affected",
              "version": "16.03.07.22"
            },
            {
              "status": "affected",
              "version": "16.03.07.23"
            },
            {
              "status": "affected",
              "version": "16.03.07.24"
            },
            {
              "status": "affected",
              "version": "16.03.07.25"
            },
            {
              "status": "affected",
              "version": "16.03.07.26"
            },
            {
              "status": "affected",
              "version": "16.03.07.27"
            },
            {
              "status": "affected",
              "version": "16.03.07.28"
            },
            {
              "status": "affected",
              "version": "16.03.07.29"
            },
            {
              "status": "affected",
              "version": "16.03.07.30"
            },
            {
              "status": "affected",
              "version": "16.03.07.31"
            },
            {
              "status": "affected",
              "version": "16.03.07.32"
            },
            {
              "status": "affected",
              "version": "16.03.07.33"
            },
            {
              "status": "affected",
              "version": "16.03.07.34"
            },
            {
              "status": "affected",
              "version": "16.03.07.35"
            },
            {
              "status": "affected",
              "version": "16.03.07.36"
            },
            {
              "status": "affected",
              "version": "16.03.07.37"
            },
            {
              "status": "affected",
              "version": "16.03.07.38"
            },
            {
              "status": "affected",
              "version": "16.03.07.39"
            },
            {
              "status": "affected",
              "version": "16.03.07.40"
            },
            {
              "status": "affected",
              "version": "16.03.07.41"
            },
            {
              "status": "affected",
              "version": "16.03.07.42"
            },
            {
              "status": "affected",
              "version": "16.03.07.43"
            },
            {
              "status": "affected",
              "version": "16.03.07.44"
            },
            {
              "status": "affected",
              "version": "16.03.07.45"
            },
            {
              "status": "affected",
              "version": "16.03.07.46"
            },
            {
              "status": "affected",
              "version": "16.03.07.47"
            },
            {
              "status": "affected",
              "version": "16.03.07.48"
            },
            {
              "status": "affected",
              "version": "16.03.07.49"
            },
            {
              "status": "affected",
              "version": "16.03.07.50"
            },
            {
              "status": "affected",
              "version": "16.03.07.51"
            },
            {
              "status": "affected",
              "version": "16.03.07.52"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "cymiao (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC23 up to 16.03.07.52. Affected by this issue is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. It is possible to launch the attack remotely. The exploit has been made public and could be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda AC23 up to 16.03.07.52 entdeckt. Das betrifft die Funktion sscanf der Datei /goform/SetStaticRouteCfg. Mittels dem Manipulieren des Arguments list mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit wurde der \u00d6ffentlichkeit bekannt gemacht und k\u00f6nnte verwendet werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-07T07:02:07.348Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-327241 | Tenda AC23 SetStaticRouteCfg sscanf buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.327241"
        },
        {
          "name": "VDB-327241 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.327241"
        },
        {
          "name": "Submit #664923 | Shenzhen Tenda Technology Co.,Ltd. AC23 \u003c= V16.03.07.52 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.664923"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/cymiao1978/cve/blob/main/12.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-10-06T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-10-06T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-10-06T08:38:24.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC23 SetStaticRouteCfg sscanf buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-11356",
    "datePublished": "2025-10-07T07:02:07.348Z",
    "dateReserved": "2025-10-06T06:33:20.887Z",
    "dateUpdated": "2025-10-07T18:13:39.826Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-10803 (GCVE-0-2025-10803)

Vulnerability from cvelistv5 – Published: 2025-09-22 15:02 – Updated: 2025-09-22 17:18
VLAI?
Title
Tenda AC23 HTTP POST Request SetPptpServerCfg sscanf buffer overflow
Summary
A vulnerability has been found in Tenda AC23 up to 16.03.07.52. Affected by this vulnerability is the function sscanf of the file /goform/SetPptpServerCfg of the component HTTP POST Request Handler. Such manipulation of the argument startIp leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC23 Affected: 16.03.07.0
Affected: 16.03.07.1
Affected: 16.03.07.2
Affected: 16.03.07.3
Affected: 16.03.07.4
Affected: 16.03.07.5
Affected: 16.03.07.6
Affected: 16.03.07.7
Affected: 16.03.07.8
Affected: 16.03.07.9
Affected: 16.03.07.10
Affected: 16.03.07.11
Affected: 16.03.07.12
Affected: 16.03.07.13
Affected: 16.03.07.14
Affected: 16.03.07.15
Affected: 16.03.07.16
Affected: 16.03.07.17
Affected: 16.03.07.18
Affected: 16.03.07.19
Affected: 16.03.07.20
Affected: 16.03.07.21
Affected: 16.03.07.22
Affected: 16.03.07.23
Affected: 16.03.07.24
Affected: 16.03.07.25
Affected: 16.03.07.26
Affected: 16.03.07.27
Affected: 16.03.07.28
Affected: 16.03.07.29
Affected: 16.03.07.30
Affected: 16.03.07.31
Affected: 16.03.07.32
Affected: 16.03.07.33
Affected: 16.03.07.34
Affected: 16.03.07.35
Affected: 16.03.07.36
Affected: 16.03.07.37
Affected: 16.03.07.38
Affected: 16.03.07.39
Affected: 16.03.07.40
Affected: 16.03.07.41
Affected: 16.03.07.42
Affected: 16.03.07.43
Affected: 16.03.07.44
Affected: 16.03.07.45
Affected: 16.03.07.46
Affected: 16.03.07.47
Affected: 16.03.07.48
Affected: 16.03.07.49
Affected: 16.03.07.50
Affected: 16.03.07.51
Affected: 16.03.07.52
Create a notification for this product.
Credits
QMSSDXN (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-10803",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-22T17:16:33.052690Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-22T17:18:36.553Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "HTTP POST Request Handler"
          ],
          "product": "AC23",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.07.0"
            },
            {
              "status": "affected",
              "version": "16.03.07.1"
            },
            {
              "status": "affected",
              "version": "16.03.07.2"
            },
            {
              "status": "affected",
              "version": "16.03.07.3"
            },
            {
              "status": "affected",
              "version": "16.03.07.4"
            },
            {
              "status": "affected",
              "version": "16.03.07.5"
            },
            {
              "status": "affected",
              "version": "16.03.07.6"
            },
            {
              "status": "affected",
              "version": "16.03.07.7"
            },
            {
              "status": "affected",
              "version": "16.03.07.8"
            },
            {
              "status": "affected",
              "version": "16.03.07.9"
            },
            {
              "status": "affected",
              "version": "16.03.07.10"
            },
            {
              "status": "affected",
              "version": "16.03.07.11"
            },
            {
              "status": "affected",
              "version": "16.03.07.12"
            },
            {
              "status": "affected",
              "version": "16.03.07.13"
            },
            {
              "status": "affected",
              "version": "16.03.07.14"
            },
            {
              "status": "affected",
              "version": "16.03.07.15"
            },
            {
              "status": "affected",
              "version": "16.03.07.16"
            },
            {
              "status": "affected",
              "version": "16.03.07.17"
            },
            {
              "status": "affected",
              "version": "16.03.07.18"
            },
            {
              "status": "affected",
              "version": "16.03.07.19"
            },
            {
              "status": "affected",
              "version": "16.03.07.20"
            },
            {
              "status": "affected",
              "version": "16.03.07.21"
            },
            {
              "status": "affected",
              "version": "16.03.07.22"
            },
            {
              "status": "affected",
              "version": "16.03.07.23"
            },
            {
              "status": "affected",
              "version": "16.03.07.24"
            },
            {
              "status": "affected",
              "version": "16.03.07.25"
            },
            {
              "status": "affected",
              "version": "16.03.07.26"
            },
            {
              "status": "affected",
              "version": "16.03.07.27"
            },
            {
              "status": "affected",
              "version": "16.03.07.28"
            },
            {
              "status": "affected",
              "version": "16.03.07.29"
            },
            {
              "status": "affected",
              "version": "16.03.07.30"
            },
            {
              "status": "affected",
              "version": "16.03.07.31"
            },
            {
              "status": "affected",
              "version": "16.03.07.32"
            },
            {
              "status": "affected",
              "version": "16.03.07.33"
            },
            {
              "status": "affected",
              "version": "16.03.07.34"
            },
            {
              "status": "affected",
              "version": "16.03.07.35"
            },
            {
              "status": "affected",
              "version": "16.03.07.36"
            },
            {
              "status": "affected",
              "version": "16.03.07.37"
            },
            {
              "status": "affected",
              "version": "16.03.07.38"
            },
            {
              "status": "affected",
              "version": "16.03.07.39"
            },
            {
              "status": "affected",
              "version": "16.03.07.40"
            },
            {
              "status": "affected",
              "version": "16.03.07.41"
            },
            {
              "status": "affected",
              "version": "16.03.07.42"
            },
            {
              "status": "affected",
              "version": "16.03.07.43"
            },
            {
              "status": "affected",
              "version": "16.03.07.44"
            },
            {
              "status": "affected",
              "version": "16.03.07.45"
            },
            {
              "status": "affected",
              "version": "16.03.07.46"
            },
            {
              "status": "affected",
              "version": "16.03.07.47"
            },
            {
              "status": "affected",
              "version": "16.03.07.48"
            },
            {
              "status": "affected",
              "version": "16.03.07.49"
            },
            {
              "status": "affected",
              "version": "16.03.07.50"
            },
            {
              "status": "affected",
              "version": "16.03.07.51"
            },
            {
              "status": "affected",
              "version": "16.03.07.52"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "QMSSDXN (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda AC23 up to 16.03.07.52. Affected by this vulnerability is the function sscanf of the file /goform/SetPptpServerCfg of the component HTTP POST Request Handler. Such manipulation of the argument startIp leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda AC23 up to 16.03.07.52 entdeckt. Betroffen hiervon ist die Funktion sscanf der Datei /goform/SetPptpServerCfg der Komponente HTTP POST Request Handler. Die Manipulation des Arguments startIp f\u00fchrt zu buffer overflow. Der Angriff kann remote ausgef\u00fchrt werden. Der Exploit wurde der \u00d6ffentlichkeit bekannt gemacht und k\u00f6nnte verwendet werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-22T15:02:07.142Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-325161 | Tenda AC23 HTTP POST Request SetPptpServerCfg sscanf buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.325161"
        },
        {
          "name": "VDB-325161 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.325161"
        },
        {
          "name": "Submit #654237 | Tenda AC23 \u003c= V16.03.07.52 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.654237"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/lin-3-start/lin-cve/blob/main/Tenda%20AC23-3/Tenda%20AC23%20Buffer%20overflow.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-09-21T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-09-21T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-09-21T11:45:15.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC23 HTTP POST Request SetPptpServerCfg sscanf buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-10803",
    "datePublished": "2025-09-22T15:02:07.142Z",
    "dateReserved": "2025-09-21T09:39:45.186Z",
    "dateUpdated": "2025-09-22T17:18:36.553Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-9605 (GCVE-0-2025-9605)

Vulnerability from cvelistv5 – Published: 2025-08-29 02:02 – Updated: 2025-08-29 13:31
VLAI?
Title
Tenda AC21/AC23 GetParentControlInfo stack-based overflow
Summary
A security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. Such manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
lxyilu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9605",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-29T13:31:03.332380Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-29T13:31:06.430Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC23/Stack-Based%20Buffer%20Overflow%20in%20Tenda%20Wi-Fi%205%20Router%20AC23%EF%BC%88AC23V1.0re_V16.03.07.52%EF%BC%89.md"
          },
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC21/AC21V1.0re_V16.03.08.16.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        },
        {
          "product": "AC23",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "lxyilu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. Such manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC21 and AC23 16.03.08.16 ist eine Schwachstelle entdeckt worden. Betroffen ist die Funktion GetParentControlInfo der Datei /goform/GetParentControlInfo. Durch das Manipulieren des Arguments mac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Ein Angriff ist aus der Distanz m\u00f6glich. Der Exploit ist \u00f6ffentlich verf\u00fcgbar und k\u00f6nnte genutzt werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 10,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-29T02:02:08.778Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-321783 | Tenda AC21/AC23 GetParentControlInfo stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.321783"
        },
        {
          "name": "VDB-321783 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.321783"
        },
        {
          "name": "Submit #636545 | Tenda Wi-Fi 5 Router AC21 AC21V1.0re_V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.636545"
        },
        {
          "name": "Submit #636548 | Tenda Wi-Fi 5 Router AC23 AC23V1.0re_V16.03.07.52 Buffer Overflow (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.636548"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC21/AC21V1.0re_V16.03.08.16.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC23/Stack-Based%20Buffer%20Overflow%20in%20Tenda%20Wi-Fi%205%20Router%20AC23%EF%BC%88AC23V1.0re_V16.03.07.52%EF%BC%89.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-08-28T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-08-28T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-08-28T17:27:38.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21/AC23 GetParentControlInfo stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-9605",
    "datePublished": "2025-08-29T02:02:08.778Z",
    "dateReserved": "2025-08-28T15:21:33.747Z",
    "dateUpdated": "2025-08-29T13:31:06.430Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-8060 (GCVE-0-2025-8060)

Vulnerability from cvelistv5 – Published: 2025-07-23 01:32 – Updated: 2025-07-23 15:14
VLAI?
Title
Tenda AC23 httpd setMacFilterCfg sub_46C940 stack-based overflow
Summary
A vulnerability has been found in Tenda AC23 16.03.07.52 and classified as critical. Affected by this vulnerability is the function sub_46C940 of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC23 Affected: 16.03.07.52
Create a notification for this product.
Credits
liuchangwei (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-8060",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T14:26:02.633061Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T15:14:41.589Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Thir0th/Thir0th-CVE/blob/main/Tenda%20AC23_V16.03.07.52_has_a_stack_overflow.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "httpd"
          ],
          "product": "AC23",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.07.52"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "liuchangwei (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda AC23 16.03.07.52 and classified as critical. Affected by this vulnerability is the function sub_46C940 of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC23 16.03.07.52 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Betroffen ist die Funktion sub_46C940 der Datei /goform/setMacFilterCfg der Komponente httpd. Dank der Manipulation des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-23T01:32:06.931Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-317317 | Tenda AC23 httpd setMacFilterCfg sub_46C940 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.317317"
        },
        {
          "name": "VDB-317317 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.317317"
        },
        {
          "name": "Submit #619604 | Tenda AC23 V16.03.07.52 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.619604"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Thir0th/Thir0th-CVE/blob/main/Tenda%20AC23_V16.03.07.52_has_a_stack_overflow.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-07-22T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-07-22T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-07-22T22:46:17.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC23 httpd setMacFilterCfg sub_46C940 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-8060",
    "datePublished": "2025-07-23T01:32:06.931Z",
    "dateReserved": "2025-07-22T20:41:12.236Z",
    "dateUpdated": "2025-07-23T15:14:41.589Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-3167 (GCVE-0-2025-3167)

Vulnerability from cvelistv5 – Published: 2025-04-03 16:31 – Updated: 2025-04-03 19:42
VLAI?
Title
Tenda AC23 API Interface VerAPIMant denial of service
Summary
A vulnerability, which was classified as problematic, has been found in Tenda AC23 16.03.07.52. This issue affects some unknown processing of the file /goform/VerAPIMant of the component API Interface. The manipulation of the argument getuid leads to denial of service. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC23 Affected: 16.03.07.52
Create a notification for this product.
Credits
Li Zhiyang (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3167",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-03T19:42:29.139890Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-03T19:42:56.025Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/LZY0522/CVE/blob/main/CVE_1.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "API Interface"
          ],
          "product": "AC23",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.07.52"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Li Zhiyang (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as problematic, has been found in Tenda AC23 16.03.07.52. This issue affects some unknown processing of the file /goform/VerAPIMant of the component API Interface. The manipulation of the argument getuid leads to denial of service. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC23 16.03.07.52 entdeckt. Sie wurde als problematisch eingestuft. Betroffen davon ist ein unbekannter Prozess der Datei /goform/VerAPIMant der Komponente API Interface. Durch Manipulieren des Arguments getuid mit unbekannten Daten kann eine denial of service-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.8,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-404",
              "description": "Denial of Service",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-03T16:31:09.102Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-303113 | Tenda AC23 API Interface VerAPIMant denial of service",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.303113"
        },
        {
          "name": "VDB-303113 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.303113"
        },
        {
          "name": "Submit #543150 | Shenzhen Tenda Technology Co., Ltd. Tenda AC23 Router V16.03.07.52 Denial of Service",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.543150"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/LZY0522/CVE/blob/main/CVE_1.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-04-03T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-04-03T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-04-03T09:34:59.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC23 API Interface VerAPIMant denial of service"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-3167",
    "datePublished": "2025-04-03T16:31:09.102Z",
    "dateReserved": "2025-04-03T07:29:54.127Z",
    "dateUpdated": "2025-04-03T19:42:56.025Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-12596 (GCVE-0-2025-12596)

Vulnerability from nvd – Published: 2025-11-02 10:32 – Updated: 2025-11-03 14:54
VLAI?
Title
Tenda AC23 saveParentControlInfo buffer overflow
Summary
A security vulnerability has been detected in Tenda AC23 16.03.07.52. Affected is the function saveParentControlInfo of the file /goform/saveParentControlInfo. Such manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed publicly and may be used.
CWE
Assigner
References
https://vuldb.com/?id.330891 vdb-entrytechnical-description
https://vuldb.com/?ctiid.330891 signaturepermissions-required
https://vuldb.com/?submit.677585 third-party-advisory
https://github.com/LX-LX88/cve/issues/9 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC23 Affected: 16.03.07.52
Create a notification for this product.
Credits
LX-LX (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12596",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-03T14:54:36.500458Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-03T14:54:39.493Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/LX-LX88/cve/issues/9"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC23",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.07.52"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LX-LX (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security vulnerability has been detected in Tenda AC23 16.03.07.52. Affected is the function saveParentControlInfo of the file /goform/saveParentControlInfo. Such manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed publicly and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC23 16.03.07.52 ist eine Schwachstelle entdeckt worden. Betroffen ist die Funktion saveParentControlInfo der Datei /goform/saveParentControlInfo. Dank Manipulation des Arguments Time mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Ein Angriff ist aus der Distanz m\u00f6glich. Der Exploit wurde der \u00d6ffentlichkeit bekannt gemacht und k\u00f6nnte verwendet werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-02T10:32:06.299Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-330891 | Tenda AC23 saveParentControlInfo buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.330891"
        },
        {
          "name": "VDB-330891 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.330891"
        },
        {
          "name": "Submit #677585 | Tenda AC23 V16.03.07.52 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.677585"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/LX-LX88/cve/issues/9"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-11-01T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-11-01T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-11-01T18:26:28.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC23 saveParentControlInfo buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-12596",
    "datePublished": "2025-11-02T10:32:06.299Z",
    "dateReserved": "2025-11-01T17:21:21.802Z",
    "dateUpdated": "2025-11-03T14:54:39.493Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-12595 (GCVE-0-2025-12595)

Vulnerability from nvd – Published: 2025-11-02 10:02 – Updated: 2025-11-03 14:55
VLAI?
Title
Tenda AC23 SetVirtualServerCfg formSetVirtualSer buffer overflow
Summary
A weakness has been identified in Tenda AC23 16.03.07.52. This impacts the function formSetVirtualSer of the file /goform/SetVirtualServerCfg. This manipulation of the argument list causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been made available to the public and could be exploited.
CWE
Assigner
References
https://vuldb.com/?id.330890 vdb-entrytechnical-description
https://vuldb.com/?ctiid.330890 signaturepermissions-required
https://vuldb.com/?submit.677581 third-party-advisory
https://github.com/LX-LX88/cve/issues/8 exploitissue-tracking
https://www.tenda.com.cn/ product
Impacted products
Vendor Product Version
Tenda AC23 Affected: 16.03.07.52
Create a notification for this product.
Credits
LX-LX (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-12595",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-03T14:55:44.673004Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-03T14:55:49.338Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/LX-LX88/cve/issues/8"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC23",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.07.52"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "LX-LX (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A weakness has been identified in Tenda AC23 16.03.07.52. This impacts the function formSetVirtualSer of the file /goform/SetVirtualServerCfg. This manipulation of the argument list causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been made available to the public and could be exploited."
        },
        {
          "lang": "de",
          "value": "In Tenda AC23 16.03.07.52 wurde eine Schwachstelle gefunden. Hierbei geht es um die Funktion formSetVirtualSer der Datei /goform/SetVirtualServerCfg. Dank der Manipulation des Arguments list mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-02T10:02:07.134Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-330890 | Tenda AC23 SetVirtualServerCfg formSetVirtualSer buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.330890"
        },
        {
          "name": "VDB-330890 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.330890"
        },
        {
          "name": "Submit #677581 | Tenda AC23 V16.03.07.52 Buffer Over",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.677581"
        },
        {
          "tags": [
            "exploit",
            "issue-tracking"
          ],
          "url": "https://github.com/LX-LX88/cve/issues/8"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-11-01T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-11-01T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-11-01T18:26:26.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC23 SetVirtualServerCfg formSetVirtualSer buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-12595",
    "datePublished": "2025-11-02T10:02:07.134Z",
    "dateReserved": "2025-11-01T17:21:18.934Z",
    "dateUpdated": "2025-11-03T14:55:49.338Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-11356 (GCVE-0-2025-11356)

Vulnerability from nvd – Published: 2025-10-07 07:02 – Updated: 2025-10-07 18:13
VLAI?
Title
Tenda AC23 SetStaticRouteCfg sscanf buffer overflow
Summary
A vulnerability was found in Tenda AC23 up to 16.03.07.52. Affected by this issue is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. It is possible to launch the attack remotely. The exploit has been made public and could be used.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC23 Affected: 16.03.07.0
Affected: 16.03.07.1
Affected: 16.03.07.2
Affected: 16.03.07.3
Affected: 16.03.07.4
Affected: 16.03.07.5
Affected: 16.03.07.6
Affected: 16.03.07.7
Affected: 16.03.07.8
Affected: 16.03.07.9
Affected: 16.03.07.10
Affected: 16.03.07.11
Affected: 16.03.07.12
Affected: 16.03.07.13
Affected: 16.03.07.14
Affected: 16.03.07.15
Affected: 16.03.07.16
Affected: 16.03.07.17
Affected: 16.03.07.18
Affected: 16.03.07.19
Affected: 16.03.07.20
Affected: 16.03.07.21
Affected: 16.03.07.22
Affected: 16.03.07.23
Affected: 16.03.07.24
Affected: 16.03.07.25
Affected: 16.03.07.26
Affected: 16.03.07.27
Affected: 16.03.07.28
Affected: 16.03.07.29
Affected: 16.03.07.30
Affected: 16.03.07.31
Affected: 16.03.07.32
Affected: 16.03.07.33
Affected: 16.03.07.34
Affected: 16.03.07.35
Affected: 16.03.07.36
Affected: 16.03.07.37
Affected: 16.03.07.38
Affected: 16.03.07.39
Affected: 16.03.07.40
Affected: 16.03.07.41
Affected: 16.03.07.42
Affected: 16.03.07.43
Affected: 16.03.07.44
Affected: 16.03.07.45
Affected: 16.03.07.46
Affected: 16.03.07.47
Affected: 16.03.07.48
Affected: 16.03.07.49
Affected: 16.03.07.50
Affected: 16.03.07.51
Affected: 16.03.07.52
Create a notification for this product.
Credits
cymiao (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11356",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-07T18:13:29.018317Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-07T18:13:39.826Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC23",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.07.0"
            },
            {
              "status": "affected",
              "version": "16.03.07.1"
            },
            {
              "status": "affected",
              "version": "16.03.07.2"
            },
            {
              "status": "affected",
              "version": "16.03.07.3"
            },
            {
              "status": "affected",
              "version": "16.03.07.4"
            },
            {
              "status": "affected",
              "version": "16.03.07.5"
            },
            {
              "status": "affected",
              "version": "16.03.07.6"
            },
            {
              "status": "affected",
              "version": "16.03.07.7"
            },
            {
              "status": "affected",
              "version": "16.03.07.8"
            },
            {
              "status": "affected",
              "version": "16.03.07.9"
            },
            {
              "status": "affected",
              "version": "16.03.07.10"
            },
            {
              "status": "affected",
              "version": "16.03.07.11"
            },
            {
              "status": "affected",
              "version": "16.03.07.12"
            },
            {
              "status": "affected",
              "version": "16.03.07.13"
            },
            {
              "status": "affected",
              "version": "16.03.07.14"
            },
            {
              "status": "affected",
              "version": "16.03.07.15"
            },
            {
              "status": "affected",
              "version": "16.03.07.16"
            },
            {
              "status": "affected",
              "version": "16.03.07.17"
            },
            {
              "status": "affected",
              "version": "16.03.07.18"
            },
            {
              "status": "affected",
              "version": "16.03.07.19"
            },
            {
              "status": "affected",
              "version": "16.03.07.20"
            },
            {
              "status": "affected",
              "version": "16.03.07.21"
            },
            {
              "status": "affected",
              "version": "16.03.07.22"
            },
            {
              "status": "affected",
              "version": "16.03.07.23"
            },
            {
              "status": "affected",
              "version": "16.03.07.24"
            },
            {
              "status": "affected",
              "version": "16.03.07.25"
            },
            {
              "status": "affected",
              "version": "16.03.07.26"
            },
            {
              "status": "affected",
              "version": "16.03.07.27"
            },
            {
              "status": "affected",
              "version": "16.03.07.28"
            },
            {
              "status": "affected",
              "version": "16.03.07.29"
            },
            {
              "status": "affected",
              "version": "16.03.07.30"
            },
            {
              "status": "affected",
              "version": "16.03.07.31"
            },
            {
              "status": "affected",
              "version": "16.03.07.32"
            },
            {
              "status": "affected",
              "version": "16.03.07.33"
            },
            {
              "status": "affected",
              "version": "16.03.07.34"
            },
            {
              "status": "affected",
              "version": "16.03.07.35"
            },
            {
              "status": "affected",
              "version": "16.03.07.36"
            },
            {
              "status": "affected",
              "version": "16.03.07.37"
            },
            {
              "status": "affected",
              "version": "16.03.07.38"
            },
            {
              "status": "affected",
              "version": "16.03.07.39"
            },
            {
              "status": "affected",
              "version": "16.03.07.40"
            },
            {
              "status": "affected",
              "version": "16.03.07.41"
            },
            {
              "status": "affected",
              "version": "16.03.07.42"
            },
            {
              "status": "affected",
              "version": "16.03.07.43"
            },
            {
              "status": "affected",
              "version": "16.03.07.44"
            },
            {
              "status": "affected",
              "version": "16.03.07.45"
            },
            {
              "status": "affected",
              "version": "16.03.07.46"
            },
            {
              "status": "affected",
              "version": "16.03.07.47"
            },
            {
              "status": "affected",
              "version": "16.03.07.48"
            },
            {
              "status": "affected",
              "version": "16.03.07.49"
            },
            {
              "status": "affected",
              "version": "16.03.07.50"
            },
            {
              "status": "affected",
              "version": "16.03.07.51"
            },
            {
              "status": "affected",
              "version": "16.03.07.52"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "cymiao (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Tenda AC23 up to 16.03.07.52. Affected by this issue is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. It is possible to launch the attack remotely. The exploit has been made public and could be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda AC23 up to 16.03.07.52 entdeckt. Das betrifft die Funktion sscanf der Datei /goform/SetStaticRouteCfg. Mittels dem Manipulieren des Arguments list mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit wurde der \u00d6ffentlichkeit bekannt gemacht und k\u00f6nnte verwendet werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-07T07:02:07.348Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-327241 | Tenda AC23 SetStaticRouteCfg sscanf buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.327241"
        },
        {
          "name": "VDB-327241 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.327241"
        },
        {
          "name": "Submit #664923 | Shenzhen Tenda Technology Co.,Ltd. AC23 \u003c= V16.03.07.52 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.664923"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/cymiao1978/cve/blob/main/12.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-10-06T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-10-06T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-10-06T08:38:24.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC23 SetStaticRouteCfg sscanf buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-11356",
    "datePublished": "2025-10-07T07:02:07.348Z",
    "dateReserved": "2025-10-06T06:33:20.887Z",
    "dateUpdated": "2025-10-07T18:13:39.826Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-10803 (GCVE-0-2025-10803)

Vulnerability from nvd – Published: 2025-09-22 15:02 – Updated: 2025-09-22 17:18
VLAI?
Title
Tenda AC23 HTTP POST Request SetPptpServerCfg sscanf buffer overflow
Summary
A vulnerability has been found in Tenda AC23 up to 16.03.07.52. Affected by this vulnerability is the function sscanf of the file /goform/SetPptpServerCfg of the component HTTP POST Request Handler. Such manipulation of the argument startIp leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC23 Affected: 16.03.07.0
Affected: 16.03.07.1
Affected: 16.03.07.2
Affected: 16.03.07.3
Affected: 16.03.07.4
Affected: 16.03.07.5
Affected: 16.03.07.6
Affected: 16.03.07.7
Affected: 16.03.07.8
Affected: 16.03.07.9
Affected: 16.03.07.10
Affected: 16.03.07.11
Affected: 16.03.07.12
Affected: 16.03.07.13
Affected: 16.03.07.14
Affected: 16.03.07.15
Affected: 16.03.07.16
Affected: 16.03.07.17
Affected: 16.03.07.18
Affected: 16.03.07.19
Affected: 16.03.07.20
Affected: 16.03.07.21
Affected: 16.03.07.22
Affected: 16.03.07.23
Affected: 16.03.07.24
Affected: 16.03.07.25
Affected: 16.03.07.26
Affected: 16.03.07.27
Affected: 16.03.07.28
Affected: 16.03.07.29
Affected: 16.03.07.30
Affected: 16.03.07.31
Affected: 16.03.07.32
Affected: 16.03.07.33
Affected: 16.03.07.34
Affected: 16.03.07.35
Affected: 16.03.07.36
Affected: 16.03.07.37
Affected: 16.03.07.38
Affected: 16.03.07.39
Affected: 16.03.07.40
Affected: 16.03.07.41
Affected: 16.03.07.42
Affected: 16.03.07.43
Affected: 16.03.07.44
Affected: 16.03.07.45
Affected: 16.03.07.46
Affected: 16.03.07.47
Affected: 16.03.07.48
Affected: 16.03.07.49
Affected: 16.03.07.50
Affected: 16.03.07.51
Affected: 16.03.07.52
Create a notification for this product.
Credits
QMSSDXN (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-10803",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-22T17:16:33.052690Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-22T17:18:36.553Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "HTTP POST Request Handler"
          ],
          "product": "AC23",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.07.0"
            },
            {
              "status": "affected",
              "version": "16.03.07.1"
            },
            {
              "status": "affected",
              "version": "16.03.07.2"
            },
            {
              "status": "affected",
              "version": "16.03.07.3"
            },
            {
              "status": "affected",
              "version": "16.03.07.4"
            },
            {
              "status": "affected",
              "version": "16.03.07.5"
            },
            {
              "status": "affected",
              "version": "16.03.07.6"
            },
            {
              "status": "affected",
              "version": "16.03.07.7"
            },
            {
              "status": "affected",
              "version": "16.03.07.8"
            },
            {
              "status": "affected",
              "version": "16.03.07.9"
            },
            {
              "status": "affected",
              "version": "16.03.07.10"
            },
            {
              "status": "affected",
              "version": "16.03.07.11"
            },
            {
              "status": "affected",
              "version": "16.03.07.12"
            },
            {
              "status": "affected",
              "version": "16.03.07.13"
            },
            {
              "status": "affected",
              "version": "16.03.07.14"
            },
            {
              "status": "affected",
              "version": "16.03.07.15"
            },
            {
              "status": "affected",
              "version": "16.03.07.16"
            },
            {
              "status": "affected",
              "version": "16.03.07.17"
            },
            {
              "status": "affected",
              "version": "16.03.07.18"
            },
            {
              "status": "affected",
              "version": "16.03.07.19"
            },
            {
              "status": "affected",
              "version": "16.03.07.20"
            },
            {
              "status": "affected",
              "version": "16.03.07.21"
            },
            {
              "status": "affected",
              "version": "16.03.07.22"
            },
            {
              "status": "affected",
              "version": "16.03.07.23"
            },
            {
              "status": "affected",
              "version": "16.03.07.24"
            },
            {
              "status": "affected",
              "version": "16.03.07.25"
            },
            {
              "status": "affected",
              "version": "16.03.07.26"
            },
            {
              "status": "affected",
              "version": "16.03.07.27"
            },
            {
              "status": "affected",
              "version": "16.03.07.28"
            },
            {
              "status": "affected",
              "version": "16.03.07.29"
            },
            {
              "status": "affected",
              "version": "16.03.07.30"
            },
            {
              "status": "affected",
              "version": "16.03.07.31"
            },
            {
              "status": "affected",
              "version": "16.03.07.32"
            },
            {
              "status": "affected",
              "version": "16.03.07.33"
            },
            {
              "status": "affected",
              "version": "16.03.07.34"
            },
            {
              "status": "affected",
              "version": "16.03.07.35"
            },
            {
              "status": "affected",
              "version": "16.03.07.36"
            },
            {
              "status": "affected",
              "version": "16.03.07.37"
            },
            {
              "status": "affected",
              "version": "16.03.07.38"
            },
            {
              "status": "affected",
              "version": "16.03.07.39"
            },
            {
              "status": "affected",
              "version": "16.03.07.40"
            },
            {
              "status": "affected",
              "version": "16.03.07.41"
            },
            {
              "status": "affected",
              "version": "16.03.07.42"
            },
            {
              "status": "affected",
              "version": "16.03.07.43"
            },
            {
              "status": "affected",
              "version": "16.03.07.44"
            },
            {
              "status": "affected",
              "version": "16.03.07.45"
            },
            {
              "status": "affected",
              "version": "16.03.07.46"
            },
            {
              "status": "affected",
              "version": "16.03.07.47"
            },
            {
              "status": "affected",
              "version": "16.03.07.48"
            },
            {
              "status": "affected",
              "version": "16.03.07.49"
            },
            {
              "status": "affected",
              "version": "16.03.07.50"
            },
            {
              "status": "affected",
              "version": "16.03.07.51"
            },
            {
              "status": "affected",
              "version": "16.03.07.52"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "QMSSDXN (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda AC23 up to 16.03.07.52. Affected by this vulnerability is the function sscanf of the file /goform/SetPptpServerCfg of the component HTTP POST Request Handler. Such manipulation of the argument startIp leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in Tenda AC23 up to 16.03.07.52 entdeckt. Betroffen hiervon ist die Funktion sscanf der Datei /goform/SetPptpServerCfg der Komponente HTTP POST Request Handler. Die Manipulation des Arguments startIp f\u00fchrt zu buffer overflow. Der Angriff kann remote ausgef\u00fchrt werden. Der Exploit wurde der \u00d6ffentlichkeit bekannt gemacht und k\u00f6nnte verwendet werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-22T15:02:07.142Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-325161 | Tenda AC23 HTTP POST Request SetPptpServerCfg sscanf buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.325161"
        },
        {
          "name": "VDB-325161 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.325161"
        },
        {
          "name": "Submit #654237 | Tenda AC23 \u003c= V16.03.07.52 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.654237"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/lin-3-start/lin-cve/blob/main/Tenda%20AC23-3/Tenda%20AC23%20Buffer%20overflow.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-09-21T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-09-21T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-09-21T11:45:15.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC23 HTTP POST Request SetPptpServerCfg sscanf buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-10803",
    "datePublished": "2025-09-22T15:02:07.142Z",
    "dateReserved": "2025-09-21T09:39:45.186Z",
    "dateUpdated": "2025-09-22T17:18:36.553Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-9605 (GCVE-0-2025-9605)

Vulnerability from nvd – Published: 2025-08-29 02:02 – Updated: 2025-08-29 13:31
VLAI?
Title
Tenda AC21/AC23 GetParentControlInfo stack-based overflow
Summary
A security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. Such manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda AC21 Affected: 16.03.08.16
Create a notification for this product.
Credits
lxyilu (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9605",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-29T13:31:03.332380Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-29T13:31:06.430Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC23/Stack-Based%20Buffer%20Overflow%20in%20Tenda%20Wi-Fi%205%20Router%20AC23%EF%BC%88AC23V1.0re_V16.03.07.52%EF%BC%89.md"
          },
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC21/AC21V1.0re_V16.03.08.16.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AC21",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        },
        {
          "product": "AC23",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.08.16"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "lxyilu (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security vulnerability has been detected in Tenda AC21 and AC23 16.03.08.16. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. Such manipulation of the argument mac leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed publicly and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC21 and AC23 16.03.08.16 ist eine Schwachstelle entdeckt worden. Betroffen ist die Funktion GetParentControlInfo der Datei /goform/GetParentControlInfo. Durch das Manipulieren des Arguments mac mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Ein Angriff ist aus der Distanz m\u00f6glich. Der Exploit ist \u00f6ffentlich verf\u00fcgbar und k\u00f6nnte genutzt werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 10,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-29T02:02:08.778Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-321783 | Tenda AC21/AC23 GetParentControlInfo stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.321783"
        },
        {
          "name": "VDB-321783 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.321783"
        },
        {
          "name": "Submit #636545 | Tenda Wi-Fi 5 Router AC21 AC21V1.0re_V16.03.08.16 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.636545"
        },
        {
          "name": "Submit #636548 | Tenda Wi-Fi 5 Router AC23 AC23V1.0re_V16.03.07.52 Buffer Overflow (Duplicate)",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.636548"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC21/AC21V1.0re_V16.03.08.16.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/XXRicardo/iot-cve/blob/main/Tenda/AC23/Stack-Based%20Buffer%20Overflow%20in%20Tenda%20Wi-Fi%205%20Router%20AC23%EF%BC%88AC23V1.0re_V16.03.07.52%EF%BC%89.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-08-28T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-08-28T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-08-28T17:27:38.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC21/AC23 GetParentControlInfo stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-9605",
    "datePublished": "2025-08-29T02:02:08.778Z",
    "dateReserved": "2025-08-28T15:21:33.747Z",
    "dateUpdated": "2025-08-29T13:31:06.430Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-8060 (GCVE-0-2025-8060)

Vulnerability from nvd – Published: 2025-07-23 01:32 – Updated: 2025-07-23 15:14
VLAI?
Title
Tenda AC23 httpd setMacFilterCfg sub_46C940 stack-based overflow
Summary
A vulnerability has been found in Tenda AC23 16.03.07.52 and classified as critical. Affected by this vulnerability is the function sub_46C940 of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC23 Affected: 16.03.07.52
Create a notification for this product.
Credits
liuchangwei (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-8060",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-23T14:26:02.633061Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-23T15:14:41.589Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Thir0th/Thir0th-CVE/blob/main/Tenda%20AC23_V16.03.07.52_has_a_stack_overflow.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "httpd"
          ],
          "product": "AC23",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.07.52"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "liuchangwei (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in Tenda AC23 16.03.07.52 and classified as critical. Affected by this vulnerability is the function sub_46C940 of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AC23 16.03.07.52 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Betroffen ist die Funktion sub_46C940 der Datei /goform/setMacFilterCfg der Komponente httpd. Dank der Manipulation des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-23T01:32:06.931Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-317317 | Tenda AC23 httpd setMacFilterCfg sub_46C940 stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.317317"
        },
        {
          "name": "VDB-317317 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.317317"
        },
        {
          "name": "Submit #619604 | Tenda AC23 V16.03.07.52 Stack-based Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.619604"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Thir0th/Thir0th-CVE/blob/main/Tenda%20AC23_V16.03.07.52_has_a_stack_overflow.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-07-22T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-07-22T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-07-22T22:46:17.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC23 httpd setMacFilterCfg sub_46C940 stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-8060",
    "datePublished": "2025-07-23T01:32:06.931Z",
    "dateReserved": "2025-07-22T20:41:12.236Z",
    "dateUpdated": "2025-07-23T15:14:41.589Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-3167 (GCVE-0-2025-3167)

Vulnerability from nvd – Published: 2025-04-03 16:31 – Updated: 2025-04-03 19:42
VLAI?
Title
Tenda AC23 API Interface VerAPIMant denial of service
Summary
A vulnerability, which was classified as problematic, has been found in Tenda AC23 16.03.07.52. This issue affects some unknown processing of the file /goform/VerAPIMant of the component API Interface. The manipulation of the argument getuid leads to denial of service. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
References
Impacted products
Vendor Product Version
Tenda AC23 Affected: 16.03.07.52
Create a notification for this product.
Credits
Li Zhiyang (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3167",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-03T19:42:29.139890Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-03T19:42:56.025Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/LZY0522/CVE/blob/main/CVE_1.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "API Interface"
          ],
          "product": "AC23",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "16.03.07.52"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "Li Zhiyang (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as problematic, has been found in Tenda AC23 16.03.07.52. This issue affects some unknown processing of the file /goform/VerAPIMant of the component API Interface. The manipulation of the argument getuid leads to denial of service. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AC23 16.03.07.52 entdeckt. Sie wurde als problematisch eingestuft. Betroffen davon ist ein unbekannter Prozess der Datei /goform/VerAPIMant der Komponente API Interface. Durch Manipulieren des Arguments getuid mit unbekannten Daten kann eine denial of service-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 6.8,
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-404",
              "description": "Denial of Service",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-03T16:31:09.102Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-303113 | Tenda AC23 API Interface VerAPIMant denial of service",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.303113"
        },
        {
          "name": "VDB-303113 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.303113"
        },
        {
          "name": "Submit #543150 | Shenzhen Tenda Technology Co., Ltd. Tenda AC23 Router V16.03.07.52 Denial of Service",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.543150"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/LZY0522/CVE/blob/main/CVE_1.md"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-04-03T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-04-03T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-04-03T09:34:59.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AC23 API Interface VerAPIMant denial of service"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-3167",
    "datePublished": "2025-04-03T16:31:09.102Z",
    "dateReserved": "2025-04-03T07:29:54.127Z",
    "dateUpdated": "2025-04-03T19:42:56.025Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

VAR-202305-0900

Vulnerability from variot - Updated: 2024-05-17 23:11

A vulnerability was found in Tenda AC23 16.03.07.45_cn. It has been declared as critical. This vulnerability affects unknown code of the file /bin/ate of the component Service Port 7329. The manipulation of the argument v2 leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-228778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of ac23 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability stems from the fact that the parameter v2 of the file /bin/ate fails to properly filter special characters and commands in the construction command. Attackers can use this vulnerability to cause arbitrary command execution

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202305-0900",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.07.45_cn"
      },
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac23  firmware  16.03.07.45 cn"
      },
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac23",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac23 16.03.07.45 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "jixiang tengda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-45447"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-010293"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-2649"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tenda:ac23_firmware:16.03.07.45_cn:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tenda:ac23:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-2649"
      }
    ]
  },
  "cve": "CVE-2023-2649",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "MULTIPLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 8.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 6.4,
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2023-45447",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.2,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-2649",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2023-2649",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2023-2649",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-45447",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202305-1018",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-45447"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-010293"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-1018"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-2649"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-2649"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was found in Tenda AC23 16.03.07.45_cn. It has been declared as critical. This vulnerability affects unknown code of the file /bin/ate of the component Service Port 7329. The manipulation of the argument v2 leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-228778 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of ac23 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability stems from the fact that the parameter v2 of the file /bin/ate fails to properly filter special characters and commands in the construction command. Attackers can use this vulnerability to cause arbitrary command execution",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-2649"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-010293"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-45447"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-2649"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-2649",
        "trust": 3.9
      },
      {
        "db": "VULDB",
        "id": "228778",
        "trust": 2.5
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-010293",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-45447",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-1018",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-2649",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-45447"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-2649"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-010293"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-1018"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-2649"
      }
    ]
  },
  "id": "VAR-202305-0900",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-45447"
      }
    ],
    "trust": 1.325
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-45447"
      }
    ]
  },
  "last_update_date": "2024-05-17T23:11:04.811000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-77",
        "trust": 1.0
      },
      {
        "problemtype": "Command injection (CWE-77) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-010293"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-2649"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://vuldb.com/?ctiid.228778"
      },
      {
        "trust": 2.5,
        "url": "https://github.com/xinzhihen06/ac23tenda/blob/main/tendaac23.md"
      },
      {
        "trust": 2.5,
        "url": "https://vuldb.com/?id.228778"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-2649"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2023-2649/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/77.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-45447"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-2649"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-010293"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-1018"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-2649"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-45447"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-2649"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-010293"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-1018"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-2649"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-06-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-45447"
      },
      {
        "date": "2023-05-11T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-2649"
      },
      {
        "date": "2023-12-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-010293"
      },
      {
        "date": "2023-05-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202305-1018"
      },
      {
        "date": "2023-05-11T08:15:08.843000",
        "db": "NVD",
        "id": "CVE-2023-2649"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-06-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-45447"
      },
      {
        "date": "2023-05-11T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-2649"
      },
      {
        "date": "2023-12-08T05:33:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-010293"
      },
      {
        "date": "2023-05-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202305-1018"
      },
      {
        "date": "2024-05-17T02:23:07.263000",
        "db": "NVD",
        "id": "CVE-2023-2649"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-1018"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC23 Command Injection Vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-45447"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-1018"
      }
    ],
    "trust": 1.2
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "command injection",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202305-1018"
      }
    ],
    "trust": 0.6
  }
}

VAR-202302-0821

Vulnerability from variot - Updated: 2024-05-17 23:02

A vulnerability was found in Tenda AC23 16.03.07.45 and classified as critical. Affected by this issue is the function formSetSysToolDDNS/formGetSysToolDDNS of the file /bin/httpd. The manipulation leads to out-of-bounds write. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-220640. Shenzhen Tenda Technology Co.,Ltd. of ac23 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202302-0821",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.07.45"
      },
      {
        "model": "ac23",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac23  firmware  16.03.07.45"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-003976"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-0782"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tenda:ac23_firmware:16.03.07.45:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tenda:ac23:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-0782"
      }
    ]
  },
  "cve": "CVE-2023-0782",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "MULTIPLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 8.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 6.4,
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.2,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-0782",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2023-0782",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2023-0782",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202302-773",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-003976"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-773"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-0782"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-0782"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was found in Tenda AC23 16.03.07.45 and classified as critical. Affected by this issue is the function formSetSysToolDDNS/formGetSysToolDDNS of the file /bin/httpd. The manipulation leads to out-of-bounds write. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-220640. Shenzhen Tenda Technology Co.,Ltd. of ac23 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-0782"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-003976"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-0782"
      }
    ],
    "trust": 1.71
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-0782",
        "trust": 3.3
      },
      {
        "db": "VULDB",
        "id": "220640",
        "trust": 2.5
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-003976",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-773",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-0782",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-0782"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-003976"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-773"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-0782"
      }
    ]
  },
  "id": "VAR-202302-0821",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.45
  },
  "last_update_date": "2024-05-17T23:02:39.745000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "",
        "trust": 0.1,
        "url": "https://github.com/live-hack-cve/cve-2023-0782 "
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-0782"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [ others ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-003976"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-0782"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/jingping911/tendaac23overflow/blob/main/readme.md"
      },
      {
        "trust": 2.5,
        "url": "https://vuldb.com/?id.220640"
      },
      {
        "trust": 1.7,
        "url": "https://vuldb.com/?ctiid.220640"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-0782"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2023-0782/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/live-hack-cve/cve-2023-0782"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-0782"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-003976"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-773"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-0782"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2023-0782"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-003976"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-773"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-0782"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-02-11T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-0782"
      },
      {
        "date": "2023-10-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-003976"
      },
      {
        "date": "2023-02-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202302-773"
      },
      {
        "date": "2023-02-11T18:15:11.393000",
        "db": "NVD",
        "id": "CVE-2023-0782"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-02-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-0782"
      },
      {
        "date": "2023-10-25T02:24:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-003976"
      },
      {
        "date": "2023-02-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202302-773"
      },
      {
        "date": "2024-05-17T02:17:33.350000",
        "db": "NVD",
        "id": "CVE-2023-0782"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-773"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac23\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-003976"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202302-773"
      }
    ],
    "trust": 0.6
  }
}

VAR-202308-3430

Vulnerability from variot - Updated: 2024-01-25 23:20

In Tenda AC23 v16.03.07.45_cn, the sub_4781A4 function does not validate the parameters entered by the user, resulting in a post-authentication stack overflow vulnerability. Shenzhen Tenda Technology Co.,Ltd. of ac23 There is an input validation vulnerability in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3430",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.07.45_cn"
      },
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac23  firmware  16.03.07.45 cn"
      },
      {
        "model": "ac23",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022854"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40797"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tenda:ac23_firmware:16.03.07.45_cn:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tenda:ac23:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-40797"
      }
    ]
  },
  "cve": "CVE-2023-40797",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-40797",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2023-40797",
            "trust": 1.8,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022854"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40797"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "In Tenda AC23 v16.03.07.45_cn, the sub_4781A4 function does not validate the parameters entered by the user, resulting in a post-authentication stack overflow vulnerability. Shenzhen Tenda Technology Co.,Ltd. of ac23 There is an input validation vulnerability in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-40797"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022854"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-40797"
      }
    ],
    "trust": 1.71
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-40797",
        "trust": 2.7
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022854",
        "trust": 0.8
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-40797",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-40797"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022854"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40797"
      }
    ]
  },
  "id": "VAR-202308-3430",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.45
  },
  "last_update_date": "2024-01-25T23:20:54.146000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-20",
        "trust": 1.0
      },
      {
        "problemtype": "Inappropriate input confirmation (CWE-20) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022854"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40797"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.9,
        "url": "https://github.com/lst-oss/vulnerability/tree/main/tenda/ac23/sub_4781a4"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-40797"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-40797"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022854"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40797"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2023-40797"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022854"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40797"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-08-25T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-40797"
      },
      {
        "date": "2024-01-24T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-022854"
      },
      {
        "date": "2023-08-25T16:15:08.427000",
        "db": "NVD",
        "id": "CVE-2023-40797"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-08-25T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-40797"
      },
      {
        "date": "2024-01-24T06:57:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-022854"
      },
      {
        "date": "2023-08-29T16:11:05.843000",
        "db": "NVD",
        "id": "CVE-2023-40797"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac23\u00a0 Firmware Input Validation Vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022854"
      }
    ],
    "trust": 0.8
  }
}

VAR-202308-3400

Vulnerability from variot - Updated: 2024-01-25 23:20

The sub_451784 function does not validate the parameters entered by the user, resulting in a stack overflow vulnerability in Tenda AC23 v16.03.07.45_cn. Shenzhen Tenda Technology Co.,Ltd. of ac23 There is an input validation vulnerability in.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC23 is a dual-band Gigabit wireless router from China's Tenda Company. This vulnerability is caused by the failure of the sub_451784 function to correctly verify the length of the input data. An attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service attack

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3400",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 1.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac23",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac23 v16.03.07.45 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-69722"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022855"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40801"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tenda:ac23:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tenda:ac23_firmware:16.03.07.45_cn:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-40801"
      }
    ]
  },
  "cve": "CVE-2023-40801",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2023-69722",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-40801",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2023-40801",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-69722",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-69722"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022855"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40801"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The sub_451784 function does not validate the parameters entered by the user, resulting in a stack overflow vulnerability in Tenda AC23 v16.03.07.45_cn. Shenzhen Tenda Technology Co.,Ltd. of ac23 There is an input validation vulnerability in.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC23 is a dual-band Gigabit wireless router from China\u0027s Tenda Company. This vulnerability is caused by the failure of the sub_451784 function to correctly verify the length of the input data. An attacker can use this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-40801"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022855"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-69722"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-40801"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-40801",
        "trust": 3.3
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022855",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-69722",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-40801",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-69722"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-40801"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022855"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40801"
      }
    ]
  },
  "id": "VAR-202308-3400",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-69722"
      }
    ],
    "trust": 1.325
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-69722"
      }
    ]
  },
  "last_update_date": "2024-01-25T23:20:02.960000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-20",
        "trust": 1.0
      },
      {
        "problemtype": "Inappropriate input confirmation (CWE-20) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022855"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40801"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.9,
        "url": "https://github.com/lst-oss/vulnerability/tree/main/tenda/ac23/sub_451784"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-40801"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-69722"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-40801"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022855"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40801"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-69722"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-40801"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022855"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40801"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-09-14T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-69722"
      },
      {
        "date": "2023-08-25T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-40801"
      },
      {
        "date": "2024-01-24T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-022855"
      },
      {
        "date": "2023-08-25T15:15:09.470000",
        "db": "NVD",
        "id": "CVE-2023-40801"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-09-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-69722"
      },
      {
        "date": "2023-08-25T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-40801"
      },
      {
        "date": "2024-01-24T06:58:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-022855"
      },
      {
        "date": "2023-08-29T16:12:56.923000",
        "db": "NVD",
        "id": "CVE-2023-40801"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac23\u00a0 Input verification vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022855"
      }
    ],
    "trust": 0.8
  }
}

VAR-202308-3286

Vulnerability from variot - Updated: 2024-01-25 23:19

The compare_parentcontrol_time function does not authenticate user input parameters, resulting in a post-authentication stack overflow vulnerability in Tenda AC23 v16.03.07.45_cn. Shenzhen Tenda Technology Co.,Ltd. of ac23 There is an input validation vulnerability in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3286",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.07.45_cn"
      },
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac23  firmware  16.03.07.45 cn"
      },
      {
        "model": "ac23",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022853"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40800"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tenda:ac23_firmware:16.03.07.45_cn:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tenda:ac23:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-40800"
      }
    ]
  },
  "cve": "CVE-2023-40800",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-40800",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2023-40800",
            "trust": 1.8,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022853"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40800"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The compare_parentcontrol_time function does not authenticate user input parameters, resulting in a post-authentication stack overflow vulnerability in Tenda AC23 v16.03.07.45_cn. Shenzhen Tenda Technology Co.,Ltd. of ac23 There is an input validation vulnerability in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-40800"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022853"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-40800"
      }
    ],
    "trust": 1.71
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-40800",
        "trust": 2.7
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022853",
        "trust": 0.8
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-40800",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-40800"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022853"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40800"
      }
    ]
  },
  "id": "VAR-202308-3286",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.45
  },
  "last_update_date": "2024-01-25T23:19:32.285000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-20",
        "trust": 1.0
      },
      {
        "problemtype": "Inappropriate input confirmation (CWE-20) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022853"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40800"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.9,
        "url": "https://github.com/lst-oss/vulnerability/tree/main/tenda/ac23/compare_parentcontrol_time"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-40800"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-40800"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022853"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40800"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2023-40800"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022853"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40800"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-08-25T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-40800"
      },
      {
        "date": "2024-01-24T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-022853"
      },
      {
        "date": "2023-08-25T15:15:09.390000",
        "db": "NVD",
        "id": "CVE-2023-40800"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-08-25T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-40800"
      },
      {
        "date": "2024-01-24T06:55:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-022853"
      },
      {
        "date": "2023-08-29T16:13:13.377000",
        "db": "NVD",
        "id": "CVE-2023-40800"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac23\u00a0 Firmware Input Validation Vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022853"
      }
    ],
    "trust": 0.8
  }
}

VAR-202308-3583

Vulnerability from variot - Updated: 2024-01-25 23:17

In Tenda AC23 v16.03.07.45_cn, the formSetIPv6status and formGetWanParameter functions do not authenticate user input parameters, resulting in a post-authentication stack overflow vulnerability. Shenzhen Tenda Technology Co.,Ltd. of ac23 There is an input validation vulnerability in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3583",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.07.45_cn"
      },
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac23  firmware  16.03.07.45 cn"
      },
      {
        "model": "ac23",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022880"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40798"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tenda:ac23_firmware:16.03.07.45_cn:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tenda:ac23:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-40798"
      }
    ]
  },
  "cve": "CVE-2023-40798",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-40798",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2023-40798",
            "trust": 1.8,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022880"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40798"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "In Tenda AC23 v16.03.07.45_cn, the formSetIPv6status and formGetWanParameter functions do not authenticate user input parameters, resulting in a post-authentication stack overflow vulnerability. Shenzhen Tenda Technology Co.,Ltd. of ac23 There is an input validation vulnerability in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-40798"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022880"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-40798"
      }
    ],
    "trust": 1.71
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-40798",
        "trust": 2.7
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022880",
        "trust": 0.8
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-40798",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-40798"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022880"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40798"
      }
    ]
  },
  "id": "VAR-202308-3583",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.45
  },
  "last_update_date": "2024-01-25T23:17:10.094000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-20",
        "trust": 1.0
      },
      {
        "problemtype": "Inappropriate input confirmation (CWE-20) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022880"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40798"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.9,
        "url": "https://github.com/lst-oss/vulnerability/tree/main/tenda/ac23/formsetipv6status-formgetwanparameter"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-40798"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-40798"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022880"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40798"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2023-40798"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022880"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40798"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-08-25T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-40798"
      },
      {
        "date": "2024-01-24T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-022880"
      },
      {
        "date": "2023-08-25T16:15:08.510000",
        "db": "NVD",
        "id": "CVE-2023-40798"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-08-25T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-40798"
      },
      {
        "date": "2024-01-24T07:19:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-022880"
      },
      {
        "date": "2023-08-29T16:10:53.747000",
        "db": "NVD",
        "id": "CVE-2023-40798"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac23\u00a0 Firmware Input Validation Vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022880"
      }
    ],
    "trust": 0.8
  }
}

VAR-202308-3331

Vulnerability from variot - Updated: 2024-01-25 23:15

Tenda AC23 Vv16.03.07.45_cn is vulnerable to Buffer Overflow via sub_450A4C function. Shenzhen Tenda Technology Co.,Ltd. of ac23 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3331",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.07.45_cn"
      },
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac23  firmware  16.03.07.45 cn"
      },
      {
        "model": "ac23",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022685"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40799"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tenda:ac23_firmware:16.03.07.45_cn:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tenda:ac23:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-40799"
      }
    ]
  },
  "cve": "CVE-2023-40799",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2023-40799",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2023-40799",
            "trust": 1.8,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022685"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40799"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC23 Vv16.03.07.45_cn is vulnerable to Buffer Overflow via sub_450A4C function. Shenzhen Tenda Technology Co.,Ltd. of ac23 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-40799"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022685"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-40799"
      }
    ],
    "trust": 1.71
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-40799",
        "trust": 2.7
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022685",
        "trust": 0.8
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-40799",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-40799"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022685"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40799"
      }
    ]
  },
  "id": "VAR-202308-3331",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.45
  },
  "last_update_date": "2024-01-25T23:15:38.314000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022685"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40799"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.9,
        "url": "https://github.com/lst-oss/vulnerability/blob/main/tenda/ac23/sub_450a4c"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-40799"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-40799"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022685"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40799"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2023-40799"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022685"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40799"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-08-25T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-40799"
      },
      {
        "date": "2024-01-24T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-022685"
      },
      {
        "date": "2023-08-25T15:15:09.307000",
        "db": "NVD",
        "id": "CVE-2023-40799"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-08-25T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-40799"
      },
      {
        "date": "2024-01-24T01:32:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-022685"
      },
      {
        "date": "2023-08-29T16:05:17.997000",
        "db": "NVD",
        "id": "CVE-2023-40799"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac23\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022685"
      }
    ],
    "trust": 0.8
  }
}

VAR-202308-3228

Vulnerability from variot - Updated: 2024-01-25 23:12

The get_parentControl_list_Info function does not verify the parameters entered by the user, causing a post-authentication heap overflow vulnerability in Tenda AC23 v16.03.07.45_cn. Shenzhen Tenda Technology Co.,Ltd. of ac23 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202308-3228",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.07.45_cn"
      },
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac23  firmware  16.03.07.45 cn"
      },
      {
        "model": "ac23",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022856"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40802"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tenda:ac23_firmware:16.03.07.45_cn:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tenda:ac23:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-40802"
      }
    ]
  },
  "cve": "CVE-2023-40802",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.8,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 6.5,
            "baseSeverity": "Medium",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2023-40802",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2023-40802",
            "trust": 1.8,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022856"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40802"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The get_parentControl_list_Info function does not verify the parameters entered by the user, causing a post-authentication heap overflow vulnerability in Tenda AC23 v16.03.07.45_cn. Shenzhen Tenda Technology Co.,Ltd. of ac23 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-40802"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022856"
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-40802"
      }
    ],
    "trust": 1.71
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2023-40802",
        "trust": 2.7
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022856",
        "trust": 0.8
      },
      {
        "db": "VULMON",
        "id": "CVE-2023-40802",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-40802"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022856"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40802"
      }
    ]
  },
  "id": "VAR-202308-3228",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VARIoT devices database",
        "id": null
      }
    ],
    "trust": 0.45
  },
  "last_update_date": "2024-01-25T23:12:40.815000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022856"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40802"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.9,
        "url": "https://github.com/lst-oss/vulnerability/tree/main/tenda/ac23/get_parentcontrol_list_info"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2023-40802"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2023-40802"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022856"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40802"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULMON",
        "id": "CVE-2023-40802"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022856"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-40802"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-08-25T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-40802"
      },
      {
        "date": "2024-01-24T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-022856"
      },
      {
        "date": "2023-08-25T15:15:09.550000",
        "db": "NVD",
        "id": "CVE-2023-40802"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-08-25T00:00:00",
        "db": "VULMON",
        "id": "CVE-2023-40802"
      },
      {
        "date": "2024-01-24T06:59:00",
        "db": "JVNDB",
        "id": "JVNDB-2023-022856"
      },
      {
        "date": "2023-08-29T16:11:31.810000",
        "db": "NVD",
        "id": "CVE-2023-40802"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0ac23\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2023-022856"
      }
    ],
    "trust": 0.8
  }
}

VAR-202211-0166

Vulnerability from variot - Updated: 2023-12-18 14:03

Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the wpapsk_crypto parameter in the fromSetWirelessRepeat function. Tenda AC23 is a dual-band Gigabit wireless router from China Tenda. An attacker could exploit this vulnerability to run arbitrary code in the context of an affected application

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202211-0166",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.07.45_cn"
      },
      {
        "model": "ac23 v16.03.07.45 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15698"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43104"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tenda:ac23_firmware:16.03.07.45_cn:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tenda:ac23:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-43104"
      }
    ]
  },
  "cve": "CVE-2022-43104",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2023-15698",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-43104",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-15698",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202211-1993",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15698"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43104"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1993"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the wpapsk_crypto parameter in the fromSetWirelessRepeat function. Tenda AC23 is a dual-band Gigabit wireless router from China Tenda. An attacker could exploit this vulnerability to run arbitrary code in the context of an affected application",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-43104"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-15698"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-43104",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-15698",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1993",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15698"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43104"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1993"
      }
    ]
  },
  "id": "VAR-202211-0166",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15698"
      }
    ],
    "trust": 1.325
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15698"
      }
    ]
  },
  "last_update_date": "2023-12-18T14:03:41.301000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-43104"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://github.com/ppcrab/iot_firmware/blob/main/tenda/ac23/ac23.md#fromsetwirelessrepeatsub_45cd64sub_45cad8sub_45bb10"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-43104"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-43104/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15698"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43104"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1993"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15698"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43104"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1993"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-08T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-15698"
      },
      {
        "date": "2022-11-03T14:15:30.343000",
        "db": "NVD",
        "id": "CVE-2022-43104"
      },
      {
        "date": "2022-11-03T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-1993"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-15698"
      },
      {
        "date": "2022-11-03T17:20:35.730000",
        "db": "NVD",
        "id": "CVE-2022-43104"
      },
      {
        "date": "2022-11-04T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-1993"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1993"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC23 Stack Overflow Vulnerability (CNVD-2023-15698)",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15698"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1993"
      }
    ],
    "trust": 0.6
  }
}

VAR-202207-0340

Vulnerability from variot - Updated: 2023-12-18 13:51

Tenda AC23 v16.03.07.44 was discovered to contain a stack overflow via the AdvSetMacMtuWan function. Tenda of ac23 ac2100 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC23 is a dual-band Gigabit wireless router from Tenda, China. An attacker could exploit this vulnerability to execute arbitrary code

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202207-0340",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac23 ac2100",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "16.03.07.44"
      },
      {
        "model": "ac23 ac2100",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac23 ac2100  firmware  16.03.07.44"
      },
      {
        "model": "ac23 ac2100",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac23 ac2100",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v16.03.07.44"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51585"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-012764"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-32383"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tendacn:ac23_ac2100_firmware:16.03.07.44:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tendacn:ac23_ac2100:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-32383"
      }
    ]
  },
  "cve": "CVE-2022-32383",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2022-32383",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-51585",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-32383",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-32383",
            "trust": 1.8,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-51585",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202207-447",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-32383",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51585"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-32383"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-012764"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-32383"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-447"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC23 v16.03.07.44 was discovered to contain a stack overflow via the AdvSetMacMtuWan function. Tenda of ac23 ac2100 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC23 is a dual-band Gigabit wireless router from Tenda, China. An attacker could exploit this vulnerability to execute arbitrary code",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-32383"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-012764"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-51585"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-32383"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-32383",
        "trust": 3.9
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-012764",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-51585",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-447",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-32383",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51585"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-32383"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-012764"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-32383"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-447"
      }
    ]
  },
  "id": "VAR-202207-0340",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51585"
      }
    ],
    "trust": 1.05
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51585"
      }
    ]
  },
  "last_update_date": "2023-12-18T13:51:02.608000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-012764"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-32383"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "https://github.com/lugakki/vuln/blob/main/tenda%20ac23.pdf"
      },
      {
        "trust": 2.5,
        "url": "https://drive.google.com/file/d/1m18rn2n7gzmbri770s07ibbzmvx-5ipe/view?usp=sharing"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-32383"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-32383/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51585"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-32383"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-012764"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-32383"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-447"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51585"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-32383"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-012764"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-32383"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-447"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-07-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-51585"
      },
      {
        "date": "2022-07-06T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-32383"
      },
      {
        "date": "2023-09-01T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-012764"
      },
      {
        "date": "2022-07-06T12:15:08.267000",
        "db": "NVD",
        "id": "CVE-2022-32383"
      },
      {
        "date": "2022-07-06T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202207-447"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-07-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-51585"
      },
      {
        "date": "2022-07-13T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-32383"
      },
      {
        "date": "2023-09-01T08:15:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-012764"
      },
      {
        "date": "2022-07-13T18:42:09.153000",
        "db": "NVD",
        "id": "CVE-2022-32383"
      },
      {
        "date": "2022-08-02T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202207-447"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-447"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0ac23\u00a0ac2100\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-012764"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-447"
      }
    ],
    "trust": 0.6
  }
}

VAR-202211-0256

Vulnerability from variot - Updated: 2023-12-18 13:50

Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function. Tenda AC23 is a dual-band Gigabit wireless router from China Tenda. Attackers can take advantage of this vulnerability to execute unauthorized instructions, obtain system privileges, and then perform various illegal operations

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202211-0256",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.07.45_cn"
      },
      {
        "model": "ac23 v16.03.07.45 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15697"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43108"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tenda:ac23_firmware:16.03.07.45_cn:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tenda:ac23:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-43108"
      }
    ]
  },
  "cve": "CVE-2022-43108",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2023-15697",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-43108",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-15697",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202211-1991",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15697"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43108"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1991"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the firewallEn parameter in the formSetFirewallCfg function. Tenda AC23 is a dual-band Gigabit wireless router from China Tenda. Attackers can take advantage of this vulnerability to execute unauthorized instructions, obtain system privileges, and then perform various illegal operations",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-43108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-15697"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-43108",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-15697",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1991",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15697"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43108"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1991"
      }
    ]
  },
  "id": "VAR-202211-0256",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15697"
      }
    ],
    "trust": 1.325
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15697"
      }
    ]
  },
  "last_update_date": "2023-12-18T13:50:51.303000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-43108"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://github.com/ppcrab/iot_firmware/blob/main/tenda/ac23/ac23.md#formsetfirewallcfg"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-43108"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-43108/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15697"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43108"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1991"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15697"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43108"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1991"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-08T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-15697"
      },
      {
        "date": "2022-11-03T14:15:32.607000",
        "db": "NVD",
        "id": "CVE-2022-43108"
      },
      {
        "date": "2022-11-03T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-1991"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-15697"
      },
      {
        "date": "2022-11-03T17:28:05.413000",
        "db": "NVD",
        "id": "CVE-2022-43108"
      },
      {
        "date": "2022-11-04T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-1991"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1991"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC23 Stack Overflow Vulnerability (CNVD-2023-15697)",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15697"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1991"
      }
    ],
    "trust": 0.6
  }
}

VAR-202211-0164

Vulnerability from variot - Updated: 2023-12-18 13:46

Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the schedStartTime parameter in the setSchedWifi function. Tenda AC23 is a dual-band Gigabit wireless router from China Tenda. An attacker could exploit this vulnerability to run arbitrary code in the context of an affected application

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202211-0164",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.07.45_cn"
      },
      {
        "model": "ac23 v16.03.07.45 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15701"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43106"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tenda:ac23_firmware:16.03.07.45_cn:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tenda:ac23:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-43106"
      }
    ]
  },
  "cve": "CVE-2022-43106",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2023-15701",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-43106",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-15701",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202211-2003",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15701"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43106"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-2003"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the schedStartTime parameter in the setSchedWifi function. Tenda AC23 is a dual-band Gigabit wireless router from China Tenda. An attacker could exploit this vulnerability to run arbitrary code in the context of an affected application",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-43106"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-15701"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-43106",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-15701",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-2003",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15701"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43106"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-2003"
      }
    ]
  },
  "id": "VAR-202211-0164",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15701"
      }
    ],
    "trust": 1.325
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15701"
      }
    ]
  },
  "last_update_date": "2023-12-18T13:46:23.729000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-43106"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://github.com/ppcrab/iot_firmware/blob/main/tenda/ac23/ac23.md#setschedwifi-strcpychar-ptr--2-v8"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-43106"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-43106/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15701"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43106"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-2003"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15701"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43106"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-2003"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-08T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-15701"
      },
      {
        "date": "2022-11-03T14:15:31.397000",
        "db": "NVD",
        "id": "CVE-2022-43106"
      },
      {
        "date": "2022-11-03T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-2003"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-15701"
      },
      {
        "date": "2022-11-03T17:28:21.597000",
        "db": "NVD",
        "id": "CVE-2022-43106"
      },
      {
        "date": "2022-11-04T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-2003"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-2003"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC23 Stack Overflow Vulnerability (CNVD-2023-15701)",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15701"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-2003"
      }
    ],
    "trust": 0.6
  }
}

VAR-202207-0032

Vulnerability from variot - Updated: 2023-12-18 13:36

Tenda AC23 v16.03.07.44 was discovered to contain a stack overflow via the security_5g parameter in the function formWifiBasicSet. Tenda of ac23 ac2100 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC23 is a dual-band Gigabit wireless router from Tenda, China. No detailed vulnerability details are currently available

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202207-0032",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac23 ac2100",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "16.03.07.44"
      },
      {
        "model": "ac23 ac2100",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": "ac23 ac2100  firmware  16.03.07.44"
      },
      {
        "model": "ac23 ac2100",
        "scope": null,
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac23 ac2100",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "tenda",
        "version": null
      },
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v16.03.07.44"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51591"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-012763"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-32384"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tendacn:ac23_ac2100_firmware:16.03.07.44:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tendacn:ac23_ac2100:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-32384"
      }
    ]
  },
  "cve": "CVE-2022-32384",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.5,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Adjacent Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 5.8,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2022-32384",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.9,
            "userInteractionRequired": null,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2022-51591",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 8.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2022-32384",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-32384",
            "trust": 1.8,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-51591",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202207-297",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-32384",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51591"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-32384"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-012763"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-32384"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-297"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC23 v16.03.07.44 was discovered to contain a stack overflow via the security_5g parameter in the function formWifiBasicSet. Tenda of ac23 ac2100 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda AC23 is a dual-band Gigabit wireless router from Tenda, China. No detailed vulnerability details are currently available",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-32384"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-012763"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-51591"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-32384",
        "trust": 3.9
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-012763",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-51591",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-297",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-32384",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51591"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-32384"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-012763"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-32384"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-297"
      }
    ]
  },
  "id": "VAR-202207-0032",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51591"
      }
    ],
    "trust": 1.05
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51591"
      }
    ]
  },
  "last_update_date": "2023-12-18T13:36:51.924000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Tenda AC23 formWifiBasicSet function stack overflow vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/339771"
      },
      {
        "title": "Tenda AC23 Buffer error vulnerability fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=199844"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51591"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-297"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-012763"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-32384"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "http://tenda.com"
      },
      {
        "trust": 2.5,
        "url": "http://ac23.com"
      },
      {
        "trust": 2.5,
        "url": "https://drive.google.com/file/d/16hshichs8j3yafpkqd3xajvuwu_qvbe3/view?usp=sharing"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-32384"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-32384/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51591"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-32384"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-012763"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-32384"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-297"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51591"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-32384"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-012763"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-32384"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-297"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-07-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-51591"
      },
      {
        "date": "2022-07-01T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-32384"
      },
      {
        "date": "2023-09-01T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-012763"
      },
      {
        "date": "2022-07-01T21:15:08.320000",
        "db": "NVD",
        "id": "CVE-2022-32384"
      },
      {
        "date": "2022-07-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202207-297"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-07-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-51591"
      },
      {
        "date": "2022-07-13T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-32384"
      },
      {
        "date": "2023-09-01T08:15:00",
        "db": "JVNDB",
        "id": "JVNDB-2022-012763"
      },
      {
        "date": "2022-07-13T19:06:38.527000",
        "db": "NVD",
        "id": "CVE-2022-32384"
      },
      {
        "date": "2022-07-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202207-297"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-297"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda\u00a0 of \u00a0ac23\u00a0ac2100\u00a0 Out-of-bounds write vulnerability in firmware",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2022-012763"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-297"
      }
    ],
    "trust": 0.6
  }
}

VAR-202207-0222

Vulnerability from variot - Updated: 2023-12-18 13:11

Tenda AC23 v16.03.07.44 was discovered to contain a buffer overflow via fromAdvSetMacMtuWan. Tenda AC23 is a dual-band Gigabit wireless router from Tenda, China.

A buffer overflow vulnerability exists in Tenda AC23 v16.03.07.44, which stems from the lack of proper validation of the length in the fromAdvSetMacMtuWan function. An attacker could exploit this vulnerability to execute arbitrary code

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202207-0222",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac23 ac2100",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tendacn",
        "version": "16.03.07.44"
      },
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "v16.03.07.44"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51586"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-32386"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tendacn:ac23_ac2100_firmware:16.03.07.44:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tendacn:ac23_ac2100:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-32386"
      }
    ]
  },
  "cve": "CVE-2022-32386",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2022-51586",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULMON",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2022-32386",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "HIGH",
            "trust": 0.1,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-32386",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2022-51586",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202207-444",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULMON",
            "id": "CVE-2022-32386",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51586"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-32386"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-32386"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-444"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC23 v16.03.07.44 was discovered to contain a buffer overflow via fromAdvSetMacMtuWan. Tenda AC23 is a dual-band Gigabit wireless router from Tenda, China. \n\r\n\r\nA buffer overflow vulnerability exists in Tenda AC23 v16.03.07.44, which stems from the lack of proper validation of the length in the fromAdvSetMacMtuWan function. An attacker could exploit this vulnerability to execute arbitrary code",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-32386"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-51586"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-32386",
        "trust": 2.3
      },
      {
        "db": "CNVD",
        "id": "CNVD-2022-51586",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-444",
        "trust": 0.6
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-32386",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51586"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-32386"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-32386"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-444"
      }
    ]
  },
  "id": "VAR-202207-0222",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51586"
      }
    ],
    "trust": 1.05
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51586"
      }
    ]
  },
  "last_update_date": "2023-12-18T13:11:57.832000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-32386"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "http://tenda.com"
      },
      {
        "trust": 1.7,
        "url": "https://github.com/lugakki/vuln/blob/main/tenda%20ac23.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://ac23.com"
      },
      {
        "trust": 1.7,
        "url": "https://drive.google.com/file/d/1xptet10yjt9wclrit6ypdv5olp-u6dbr/view?usp=sharing"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-32386"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-32386/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51586"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-32386"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-32386"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-444"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51586"
      },
      {
        "db": "VULMON",
        "id": "CVE-2022-32386"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-32386"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-444"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-07-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-51586"
      },
      {
        "date": "2022-07-06T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-32386"
      },
      {
        "date": "2022-07-06T12:15:08.360000",
        "db": "NVD",
        "id": "CVE-2022-32386"
      },
      {
        "date": "2022-07-06T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202207-444"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-07-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2022-51586"
      },
      {
        "date": "2022-07-14T00:00:00",
        "db": "VULMON",
        "id": "CVE-2022-32386"
      },
      {
        "date": "2022-07-14T01:00:17.753000",
        "db": "NVD",
        "id": "CVE-2022-32386"
      },
      {
        "date": "2022-07-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202207-444"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-444"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC23 fromAdvSetMacMtuWan function buffer overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2022-51586"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202207-444"
      }
    ],
    "trust": 0.6
  }
}

VAR-202211-0230

Vulnerability from variot - Updated: 2023-12-18 13:00

Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the timeZone parameter in the fromSetSysTime function. Tenda AC23 is a dual-band Gigabit wireless router from China Tenda

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202211-0230",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.07.45_cn"
      },
      {
        "model": "ac23 v16.03.07.45 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15700"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43102"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tenda:ac23_firmware:16.03.07.45_cn:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tenda:ac23:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-43102"
      }
    ]
  },
  "cve": "CVE-2022-43102",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2023-15700",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-43102",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-15700",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202211-1995",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15700"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43102"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1995"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the timeZone parameter in the fromSetSysTime function. Tenda AC23 is a dual-band Gigabit wireless router from China Tenda",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-43102"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-15700"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-43102",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-15700",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1995",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15700"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43102"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1995"
      }
    ]
  },
  "id": "VAR-202211-0230",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15700"
      }
    ],
    "trust": 1.325
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15700"
      }
    ]
  },
  "last_update_date": "2023-12-18T13:00:30.079000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-43102"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://github.com/ppcrab/iot_firmware/blob/main/tenda/ac23/ac23.md#fromsetsystimesub_496104strcpychar-v6-s"
      },
      {
        "trust": 1.2,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-43102"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-43102/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15700"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43102"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1995"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15700"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43102"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1995"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-08T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-15700"
      },
      {
        "date": "2022-11-03T14:15:26.460000",
        "db": "NVD",
        "id": "CVE-2022-43102"
      },
      {
        "date": "2022-11-03T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-1995"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-15700"
      },
      {
        "date": "2022-11-03T17:20:18.753000",
        "db": "NVD",
        "id": "CVE-2022-43102"
      },
      {
        "date": "2022-11-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-1995"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1995"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC23 Stack Overflow Vulnerability (CNVD-2023-15700)",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15700"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1995"
      }
    ],
    "trust": 0.6
  }
}

VAR-202211-0263

Vulnerability from variot - Updated: 2023-12-18 12:54

Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function. Tenda AC23 is a dual-band Gigabit wireless router from China Tenda.

A buffer overflow vulnerability exists in the Tenda AC23 fromSetWifiGusetBasic function, which could be exploited by an attacker to run arbitrary code in the context of the affected application

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202211-0263",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "ac23",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenda",
        "version": "16.03.07.45_cn"
      },
      {
        "model": "ac23 v16.03.07.45 cn",
        "scope": null,
        "trust": 0.6,
        "vendor": "tenda",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15696"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43105"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:tenda:ac23_firmware:16.03.07.45_cn:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:tenda:ac23:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-43105"
      }
    ]
  },
  "cve": "CVE-2022-43105",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2023-15696",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2022-43105",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2023-15696",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202211-1992",
            "trust": 0.6,
            "value": "CRITICAL"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15696"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43105"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1992"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC23 V16.03.07.45_cn was discovered to contain a stack overflow via the shareSpeed parameter in the fromSetWifiGusetBasic function. Tenda AC23 is a dual-band Gigabit wireless router from China Tenda. \n\r\n\r\nA buffer overflow vulnerability exists in the Tenda AC23 fromSetWifiGusetBasic function, which could be exploited by an attacker to run arbitrary code in the context of the affected application",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-43105"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-15696"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2022-43105",
        "trust": 2.2
      },
      {
        "db": "CNVD",
        "id": "CNVD-2023-15696",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1992",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15696"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43105"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1992"
      }
    ]
  },
  "id": "VAR-202211-0263",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15696"
      }
    ],
    "trust": 1.325
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15696"
      }
    ]
  },
  "last_update_date": "2023-12-18T12:54:41.961000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2022-43105"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://github.com/ppcrab/iot_firmware/blob/main/tenda/ac23/ac23.md#fromsetwifigusetbasic"
      },
      {
        "trust": 0.6,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2022-43105"
      },
      {
        "trust": 0.6,
        "url": "https://cxsecurity.com/cveshow/cve-2022-43105/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15696"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43105"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1992"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15696"
      },
      {
        "db": "NVD",
        "id": "CVE-2022-43105"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1992"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-08T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-15696"
      },
      {
        "date": "2022-11-03T14:15:30.740000",
        "db": "NVD",
        "id": "CVE-2022-43105"
      },
      {
        "date": "2022-11-03T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-1992"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-03-09T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2023-15696"
      },
      {
        "date": "2022-11-03T17:28:30.687000",
        "db": "NVD",
        "id": "CVE-2022-43105"
      },
      {
        "date": "2022-11-04T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202211-1992"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1992"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda AC23 fromSetWifiGusetBasic function buffer overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2023-15696"
      }
    ],
    "trust": 0.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202211-1992"
      }
    ],
    "trust": 0.6
  }
}