Search criteria
39 vulnerabilities found for ac5 by tenda
CVE-2025-6887 (GCVE-0-2025-6887)
Vulnerability from cvelistv5 – Published: 2025-06-30 04:32 – Updated: 2025-06-30 16:20| URL | Tags | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6887",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-30T16:10:08.094822Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-30T16:20:32.529Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC5",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.47"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_tu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this issue is some unknown functionality of the file /goform/SetSysTimeCfg. The manipulation of the argument time/timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC5 15.03.06.47 gefunden. Sie wurde als kritisch eingestuft. Es geht hierbei um eine nicht n\u00e4her spezifizierte Funktion der Datei /goform/SetSysTimeCfg. Durch Manipulieren des Arguments time/timeZone mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-30T04:32:29.352Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-314366 | Tenda AC5 SetSysTimeCfg stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.314366"
},
{
"name": "VDB-314366 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.314366"
},
{
"name": "Submit #603788 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.603788"
},
{
"name": "Submit #603789 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.603789"
},
{
"tags": [
"related"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromSetSysTime_time-21d53a41781f8002bdb3fe8344d6fd8c?source=copy_link"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromSetSysTime_timeZone-21d53a41781f8021ae2fd2ac639f1b3f?source=copy_link"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-28T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-28T17:03:52.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC5 SetSysTimeCfg stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-6887",
"datePublished": "2025-06-30T04:32:29.352Z",
"dateReserved": "2025-06-28T14:58:40.648Z",
"dateUpdated": "2025-06-30T16:20:32.529Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-6886 (GCVE-0-2025-6886)
Vulnerability from cvelistv5 – Published: 2025-06-30 04:02 – Updated: 2025-06-30 16:27| URL | Tags | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6886",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-30T16:27:27.047025Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-30T16:27:50.848Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC5",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.47"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_ (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda AC5 15.03.06.47 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Es geht um eine nicht n\u00e4her bekannte Funktion der Datei /goform/openSchedWifi. Durch das Manipulieren des Arguments schedStartTime/schedEndTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-30T04:02:23.680Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-314365 | Tenda AC5 openSchedWifi stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.314365"
},
{
"name": "VDB-314365 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.314365"
},
{
"name": "Submit #603774 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.603774"
},
{
"name": "Submit #603775 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.603775"
},
{
"tags": [
"related"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-setSchedWifi_schedEndTime-21d53a41781f80fb8a90f08898e8d404?source=copy_link"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-setSchedWifi_schedStartTime-21d53a41781f803f97eeddd9828c5c84?source=copy_link"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-28T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-28T17:03:41.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC5 openSchedWifi stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-6886",
"datePublished": "2025-06-30T04:02:23.680Z",
"dateReserved": "2025-06-28T14:58:38.446Z",
"dateUpdated": "2025-06-30T16:27:50.848Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-5863 (GCVE-0-2025-5863)
Vulnerability from cvelistv5 – Published: 2025-06-09 05:31 – Updated: 2025-06-10 14:44| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5863",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-10T14:43:54.154172Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T14:44:55.857Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC5",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.47"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_miemie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC5 15.03.06.47. It has been classified as critical. Affected is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda AC5 15.03.06.47 ausgemacht. Es geht dabei um die Funktion formSetRebootTimer der Datei /goform/SetRebootTimer. Durch die Manipulation des Arguments rebootTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-09T05:31:07.242Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-311622 | Tenda AC5 SetRebootTimer formSetRebootTimer stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.311622"
},
{
"name": "VDB-311622 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.311622"
},
{
"name": "Submit #591981 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.591981"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-formSetRebootTimer-20a53a41781f80a6b9a8f6e5915cf256?source=copy_link"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-08T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-08T15:32:27.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC5 SetRebootTimer formSetRebootTimer stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-5863",
"datePublished": "2025-06-09T05:31:07.242Z",
"dateReserved": "2025-06-08T13:27:21.149Z",
"dateUpdated": "2025-06-10T14:44:55.857Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-5795 (GCVE-0-2025-5795)
Vulnerability from cvelistv5 – Published: 2025-06-06 18:31 – Updated: 2025-06-09 15:10| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5795",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-09T15:10:41.055915Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-09T15:10:44.767Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromadvsetlanip-20a53a41781f805389dcd51fa04bc530"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC5",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0"
},
{
"status": "affected",
"version": "15.03.06.47"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_backup (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Tenda AC5 1.0/15.03.06.47. This affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda AC5 1.0/15.03.06.47 gefunden. Betroffen hiervon ist die Funktion fromadvsetlanip der Datei /goform/AdvSetLanip. Mittels dem Manipulieren des Arguments lanMask mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-06T18:31:11.459Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-311349 | Tenda AC5 AdvSetLanip fromadvsetlanip buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.311349"
},
{
"name": "VDB-311349 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.311349"
},
{
"name": "Submit #591224 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.591224"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromadvsetlanip-20a53a41781f805389dcd51fa04bc530?source=copy_link"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-06T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-06T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-06T10:34:38.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC5 AdvSetLanip fromadvsetlanip buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-5795",
"datePublished": "2025-06-06T18:31:11.459Z",
"dateReserved": "2025-06-06T08:29:30.876Z",
"dateUpdated": "2025-06-09T15:10:44.767Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-5794 (GCVE-0-2025-5794)
Vulnerability from cvelistv5 – Published: 2025-06-06 18:31 – Updated: 2025-06-09 15:11| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5794",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-09T15:11:12.378126Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-09T15:11:15.451Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-formSetPPTPUserList-20a53a41781f806faf61cef61ed929c0"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC5",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.47"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda AC5 15.03.06.47. Affected by this issue is the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda AC5 15.03.06.47 entdeckt. Betroffen davon ist die Funktion formSetPPTPUserList der Datei /goform/setPptpUserList. Durch Manipulation des Arguments list mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-06T18:31:07.897Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-311348 | Tenda AC5 setPptpUserList formSetPPTPUserList buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.311348"
},
{
"name": "VDB-311348 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.311348"
},
{
"name": "Submit #591223 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.591223"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-formSetPPTPUserList-20a53a41781f806faf61cef61ed929c0?source=copy_link"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-06T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-06T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-06T10:34:36.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC5 setPptpUserList formSetPPTPUserList buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-5794",
"datePublished": "2025-06-06T18:31:07.897Z",
"dateReserved": "2025-06-06T08:29:28.742Z",
"dateUpdated": "2025-06-09T15:11:15.451Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-6887 (GCVE-0-2025-6887)
Vulnerability from nvd – Published: 2025-06-30 04:32 – Updated: 2025-06-30 16:20| URL | Tags | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6887",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-30T16:10:08.094822Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-30T16:20:32.529Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC5",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.47"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_tu (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this issue is some unknown functionality of the file /goform/SetSysTimeCfg. The manipulation of the argument time/timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine Schwachstelle wurde in Tenda AC5 15.03.06.47 gefunden. Sie wurde als kritisch eingestuft. Es geht hierbei um eine nicht n\u00e4her spezifizierte Funktion der Datei /goform/SetSysTimeCfg. Durch Manipulieren des Arguments time/timeZone mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-30T04:32:29.352Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-314366 | Tenda AC5 SetSysTimeCfg stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.314366"
},
{
"name": "VDB-314366 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.314366"
},
{
"name": "Submit #603788 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.603788"
},
{
"name": "Submit #603789 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.603789"
},
{
"tags": [
"related"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromSetSysTime_time-21d53a41781f8002bdb3fe8344d6fd8c?source=copy_link"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromSetSysTime_timeZone-21d53a41781f8021ae2fd2ac639f1b3f?source=copy_link"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-28T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-28T17:03:52.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC5 SetSysTimeCfg stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-6887",
"datePublished": "2025-06-30T04:32:29.352Z",
"dateReserved": "2025-06-28T14:58:40.648Z",
"dateUpdated": "2025-06-30T16:20:32.529Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-6886 (GCVE-0-2025-6886)
Vulnerability from nvd – Published: 2025-06-30 04:02 – Updated: 2025-06-30 16:27| URL | Tags | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6886",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-30T16:27:27.047025Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-30T16:27:50.848Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC5",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.47"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "wxhwxhwxh_ (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda AC5 15.03.06.47 wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Es geht um eine nicht n\u00e4her bekannte Funktion der Datei /goform/openSchedWifi. Durch das Manipulieren des Arguments schedStartTime/schedEndTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-30T04:02:23.680Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-314365 | Tenda AC5 openSchedWifi stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.314365"
},
{
"name": "VDB-314365 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.314365"
},
{
"name": "Submit #603774 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.603774"
},
{
"name": "Submit #603775 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.603775"
},
{
"tags": [
"related"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-setSchedWifi_schedEndTime-21d53a41781f80fb8a90f08898e8d404?source=copy_link"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-setSchedWifi_schedStartTime-21d53a41781f803f97eeddd9828c5c84?source=copy_link"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-28T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-28T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-28T17:03:41.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC5 openSchedWifi stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-6886",
"datePublished": "2025-06-30T04:02:23.680Z",
"dateReserved": "2025-06-28T14:58:38.446Z",
"dateUpdated": "2025-06-30T16:27:50.848Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-5863 (GCVE-0-2025-5863)
Vulnerability from nvd – Published: 2025-06-09 05:31 – Updated: 2025-06-10 14:44| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5863",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-10T14:43:54.154172Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T14:44:55.857Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC5",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.47"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_miemie (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Tenda AC5 15.03.06.47. It has been classified as critical. Affected is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda AC5 15.03.06.47 ausgemacht. Es geht dabei um die Funktion formSetRebootTimer der Datei /goform/SetRebootTimer. Durch die Manipulation des Arguments rebootTime mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-09T05:31:07.242Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-311622 | Tenda AC5 SetRebootTimer formSetRebootTimer stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.311622"
},
{
"name": "VDB-311622 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.311622"
},
{
"name": "Submit #591981 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.591981"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-formSetRebootTimer-20a53a41781f80a6b9a8f6e5915cf256?source=copy_link"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-08T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-08T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-08T15:32:27.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC5 SetRebootTimer formSetRebootTimer stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-5863",
"datePublished": "2025-06-09T05:31:07.242Z",
"dateReserved": "2025-06-08T13:27:21.149Z",
"dateUpdated": "2025-06-10T14:44:55.857Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-5795 (GCVE-0-2025-5795)
Vulnerability from nvd – Published: 2025-06-06 18:31 – Updated: 2025-06-09 15:10| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5795",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-09T15:10:41.055915Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-09T15:10:44.767Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromadvsetlanip-20a53a41781f805389dcd51fa04bc530"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC5",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.0"
},
{
"status": "affected",
"version": "15.03.06.47"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr_backup (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Tenda AC5 1.0/15.03.06.47. This affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine kritische Schwachstelle in Tenda AC5 1.0/15.03.06.47 gefunden. Betroffen hiervon ist die Funktion fromadvsetlanip der Datei /goform/AdvSetLanip. Mittels dem Manipulieren des Arguments lanMask mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-06T18:31:11.459Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-311349 | Tenda AC5 AdvSetLanip fromadvsetlanip buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.311349"
},
{
"name": "VDB-311349 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.311349"
},
{
"name": "Submit #591224 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.591224"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-fromadvsetlanip-20a53a41781f805389dcd51fa04bc530?source=copy_link"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-06T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-06T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-06T10:34:38.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC5 AdvSetLanip fromadvsetlanip buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-5795",
"datePublished": "2025-06-06T18:31:11.459Z",
"dateReserved": "2025-06-06T08:29:30.876Z",
"dateUpdated": "2025-06-09T15:10:44.767Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-5794 (GCVE-0-2025-5794)
Vulnerability from nvd – Published: 2025-06-06 18:31 – Updated: 2025-06-09 15:11| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5794",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-09T15:11:12.378126Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-09T15:11:15.451Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-formSetPPTPUserList-20a53a41781f806faf61cef61ed929c0"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC5",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.47"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "yhryhryhr (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, has been found in Tenda AC5 15.03.06.47. Affected by this issue is the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Eine kritische Schwachstelle wurde in Tenda AC5 15.03.06.47 entdeckt. Betroffen davon ist die Funktion formSetPPTPUserList der Datei /goform/setPptpUserList. Durch Manipulation des Arguments list mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-06T18:31:07.897Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-311348 | Tenda AC5 setPptpUserList formSetPPTPUserList buffer overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.311348"
},
{
"name": "VDB-311348 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.311348"
},
{
"name": "Submit #591223 | Tenda AC5 V1.0 V15.03.06.47 Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.591223"
},
{
"tags": [
"exploit"
],
"url": "https://lavender-bicycle-a5a.notion.site/Tenda-AC5-formSetPPTPUserList-20a53a41781f806faf61cef61ed929c0?source=copy_link"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-06T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-06T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-06T10:34:36.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC5 setPptpUserList formSetPPTPUserList buffer overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-5794",
"datePublished": "2025-06-06T18:31:07.897Z",
"dateReserved": "2025-06-06T08:29:28.742Z",
"dateUpdated": "2025-06-09T15:11:15.451Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
VAR-202201-1106
Vulnerability from variot - Updated: 2024-02-14 22:58Multiple Tenda devices are affected by authentication bypass, such as AC15V1.0 Firmware V15.03.05.20_multi?AC5V1.0 Firmware V15.03.06.48_multi and so on. an attacker can obtain sensitive information, and even combine it with authenticated command injection to implement RCE. AC15V1.0 and AC5V1.0 An improper comparison vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC15 is a wireless router from the Chinese company Tenda
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202201-1106",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac15",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.05.20_multi"
},
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.48_multi"
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac15",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac15v1.0 15.03.05.20 multi",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
},
{
"model": "ac15v1.0 15.03.06.48 multi",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-22299"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-004279"
},
{
"db": "NVD",
"id": "CVE-2021-44971"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.20_multi:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac15:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.48_multi:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2021-44971"
}
]
},
"cve": "CVE-2021-44971",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Partial",
"baseScore": 7.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2021-44971",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2022-22299",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2021-44971",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2021-44971",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2022-22299",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202201-2607",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-22299"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-004279"
},
{
"db": "CNNVD",
"id": "CNNVD-202201-2607"
},
{
"db": "NVD",
"id": "CVE-2021-44971"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Multiple Tenda devices are affected by authentication bypass, such as AC15V1.0 Firmware V15.03.05.20_multi?AC5V1.0 Firmware V15.03.06.48_multi and so on. an attacker can obtain sensitive information, and even combine it with authenticated command injection to implement RCE. AC15V1.0 and AC5V1.0 An improper comparison vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Tenda AC15 is a wireless router from the Chinese company Tenda",
"sources": [
{
"db": "NVD",
"id": "CVE-2021-44971"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-004279"
},
{
"db": "CNVD",
"id": "CNVD-2022-22299"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2021-44971",
"trust": 3.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-004279",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2022-22299",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202201-2607",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-22299"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-004279"
},
{
"db": "CNNVD",
"id": "CNNVD-202201-2607"
},
{
"db": "NVD",
"id": "CVE-2021-44971"
}
]
},
"id": "VAR-202201-1106",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-22299"
}
],
"trust": 1.4106146000000002
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-22299"
}
]
},
"last_update_date": "2024-02-14T22:58:52.351000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Top\u00a0Page",
"trust": 0.8,
"url": "https://tenda.com/"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-004279"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-697",
"trust": 1.0
},
{
"problemtype": "Inappropriate comparison (CWE-697) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-004279"
},
{
"db": "NVD",
"id": "CVE-2021-44971"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/21gun5/my_cve/blob/main/tenda/bypass_auth.md"
},
{
"trust": 2.0,
"url": "https://nvd.nist.gov/vuln/detail/cve-2021-44971"
},
{
"trust": 1.6,
"url": "http://ac15v10.com"
},
{
"trust": 1.6,
"url": "http://tenda.com"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2022-22299"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-004279"
},
{
"db": "CNNVD",
"id": "CNNVD-202201-2607"
},
{
"db": "NVD",
"id": "CVE-2021-44971"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2022-22299"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-004279"
},
{
"db": "CNNVD",
"id": "CNNVD-202201-2607"
},
{
"db": "NVD",
"id": "CVE-2021-44971"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-03-24T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-22299"
},
{
"date": "2023-04-04T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-004279"
},
{
"date": "2022-01-28T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202201-2607"
},
{
"date": "2022-01-28T19:15:07.963000",
"db": "NVD",
"id": "CVE-2021-44971"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-03-24T00:00:00",
"db": "CNVD",
"id": "CNVD-2022-22299"
},
{
"date": "2023-04-04T05:01:00",
"db": "JVNDB",
"id": "JVNDB-2022-004279"
},
{
"date": "2022-07-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202201-2607"
},
{
"date": "2024-02-14T01:17:43.863000",
"db": "NVD",
"id": "CVE-2021-44971"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202201-2607"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "AC15V1.0\u00a0 and \u00a0AC5V1.0\u00a0 Improper Comparison Vulnerability in Firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-004279"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "authorization issue",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202201-2607"
}
],
"trust": 0.6
}
}
VAR-202308-3781
Vulnerability from variot - Updated: 2024-01-20 23:21Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-3781",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "fh1205",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.0.7\\(775\\)"
},
{
"model": "fh1203",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.1.6"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.42_multi"
},
{
"model": "ac6",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac7",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.44"
},
{
"model": "f1203",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.1.6"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "fh1203",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac10",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "fh1205",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "f1203",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac7",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021661"
},
{
"db": "NVD",
"id": "CVE-2023-38933"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38933"
}
]
},
"cve": "CVE-2023-38933",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38933",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38933",
"trust": 1.8,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021661"
},
{
"db": "NVD",
"id": "CVE-2023-38933"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38933"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021661"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38933",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021661",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021661"
},
{
"db": "NVD",
"id": "CVE-2023-38933"
}
]
},
"id": "VAR-202308-3781",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.66374115
},
"last_update_date": "2024-01-20T23:21:05.858000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021661"
},
{
"db": "NVD",
"id": "CVE-2023-38933"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetclientstate/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38933"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021661"
},
{
"db": "NVD",
"id": "CVE-2023-38933"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021661"
},
{
"db": "NVD",
"id": "CVE-2023-38933"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021661"
},
{
"date": "2023-08-07T19:15:11.133000",
"db": "NVD",
"id": "CVE-2023-38933"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T07:51:00",
"db": "JVNDB",
"id": "JVNDB-2023-021661"
},
{
"date": "2023-08-10T17:17:41.653000",
"db": "NVD",
"id": "CVE-2023-38933"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021661"
}
],
"trust": 0.8
}
}
VAR-202308-4027
Vulnerability from variot - Updated: 2024-01-20 23:18Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function. ac1206 firmware, AC5 firmware, AC9 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-4027",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.10.13"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.42_multi"
},
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac10",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021660"
},
{
"db": "NVD",
"id": "CVE-2023-38935"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38935"
}
]
},
"cve": "CVE-2023-38935",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38935",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38935",
"trust": 1.8,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021660"
},
{
"db": "NVD",
"id": "CVE-2023-38935"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC1206 V15.03.06.23, AC8 V4 V16.03.34.06, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and AC9 V3.0 V15.03.06.42_multi were discovered to contain a tack overflow via the list parameter in the formSetQosBand function. ac1206 firmware, AC5 firmware, AC9 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38935"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021660"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38935",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021660",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021660"
},
{
"db": "NVD",
"id": "CVE-2023-38935"
}
]
},
"id": "VAR-202308-4027",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.5516548666666666
},
"last_update_date": "2024-01-20T23:18:08.182000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021660"
},
{
"db": "NVD",
"id": "CVE-2023-38935"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetqosband/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38935"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021660"
},
{
"db": "NVD",
"id": "CVE-2023-38935"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021660"
},
{
"db": "NVD",
"id": "CVE-2023-38935"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021660"
},
{
"date": "2023-08-07T19:15:11.277000",
"db": "NVD",
"id": "CVE-2023-38935"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T07:51:00",
"db": "JVNDB",
"id": "JVNDB-2023-021660"
},
{
"date": "2023-08-10T17:18:24.527000",
"db": "NVD",
"id": "CVE-2023-38935"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021660"
}
],
"trust": 0.8
}
}
VAR-202308-3714
Vulnerability from variot - Updated: 2024-01-20 23:18Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-3714",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "fh1205",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.0.7\\(775\\)"
},
{
"model": "fh1203",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.1.6"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.42_multi"
},
{
"model": "ac6",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac7",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.44"
},
{
"model": "f1203",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.1.6"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "fh1203",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac10",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "fh1205",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "f1203",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac7",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"cve": "CVE-2023-38936",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38936",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38936",
"trust": 1.8,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. AC10 firmware, ac1206 firmware, AC6 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38936"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38936",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021659",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"id": "VAR-202308-3714",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.66374115
},
"last_update_date": "2024-01-20T23:18:08.206000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetspeedwan/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38936"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"date": "2023-08-07T19:15:11.343000",
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T07:51:00",
"db": "JVNDB",
"id": "JVNDB-2023-021659"
},
{
"date": "2023-08-10T18:20:51.897000",
"db": "NVD",
"id": "CVE-2023-38936"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021659"
}
],
"trust": 0.8
}
}
VAR-202308-4213
Vulnerability from variot - Updated: 2024-01-20 23:04Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. AC10 firmware, ac1206 firmware, AC8 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-4213",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.10.13"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.42_multi"
},
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac6",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac7",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.44"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac10",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac7",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"cve": "CVE-2023-38937",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38937",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38937",
"trust": 1.8,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. AC10 firmware, ac1206 firmware, AC8 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38937"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38937",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021658",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"id": "VAR-202308-4213",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.5516548666666666
},
"last_update_date": "2024-01-20T23:04:04.486000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/formsetvirtualser/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38937"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"date": "2023-08-07T19:15:11.413000",
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T07:51:00",
"db": "JVNDB",
"id": "JVNDB-2023-021658"
},
{
"date": "2023-08-10T18:22:01.703000",
"db": "NVD",
"id": "CVE-2023-38937"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021658"
}
],
"trust": 0.8
}
}
VAR-202308-4145
Vulnerability from variot - Updated: 2024-01-20 23:01Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function. AC10 firmware, ac1206 firmware, AC8 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-4145",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "fh1203",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.1.6"
},
{
"model": "ac6",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.23"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.10.13"
},
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac8",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "16.03.34.06"
},
{
"model": "ac7",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.44"
},
{
"model": "f1203",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.1.6"
},
{
"model": "ac1206",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "fh1203",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac6",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac10",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "f1203",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac7",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac8",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021662"
},
{
"db": "NVD",
"id": "CVE-2023-38931"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac10:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac1206_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac8_firmware:16.03.34.06:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac8:4.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac6_firmware:15.03.06.23:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac6:2.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac10_firmware:16.03.10.13:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:fh1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:fh1203:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38931"
}
]
},
"cve": "CVE-2023-38931",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38931",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38931",
"trust": 1.8,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021662"
},
{
"db": "NVD",
"id": "CVE-2023-38931"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function. AC10 firmware, ac1206 firmware, AC8 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38931"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021662"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38931",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021662",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021662"
},
{
"db": "NVD",
"id": "CVE-2023-38931"
}
]
},
"id": "VAR-202308-4145",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.7355521133333333
},
"last_update_date": "2024-01-20T23:01:00.503000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021662"
},
{
"db": "NVD",
"id": "CVE-2023-38931"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/cloudv2_setaccount/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38931"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021662"
},
{
"db": "NVD",
"id": "CVE-2023-38931"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021662"
},
{
"db": "NVD",
"id": "CVE-2023-38931"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021662"
},
{
"date": "2023-08-07T19:15:10.977000",
"db": "NVD",
"id": "CVE-2023-38931"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-19T07:51:00",
"db": "JVNDB",
"id": "JVNDB-2023-021662"
},
{
"date": "2023-08-10T17:17:05.110000",
"db": "NVD",
"id": "CVE-2023-38931"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021662"
}
],
"trust": 0.8
}
}
VAR-202308-3852
Vulnerability from variot - Updated: 2024-01-19 23:21Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. AC7 firmware, f1203 firmware, fh1205 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-3852",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "fh1205",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.0.7\\(775\\)"
},
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.42_multi"
},
{
"model": "ac7",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.44"
},
{
"model": "f1203",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "2.0.1.6"
},
{
"model": "f1203",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac7",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "fh1205",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac9",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021095"
},
{
"db": "NVD",
"id": "CVE-2023-38930"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac7_firmware:15.03.06.44:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac7:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:f1203_firmware:2.0.1.6:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:f1203:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:fh1205_firmware:2.0.0.7\\(775\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:fh1205:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac9_firmware:15.03.06.42_multi:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac9:3.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38930"
}
]
},
"cve": "CVE-2023-38930",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38930",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-38930",
"trust": 1.8,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021095"
},
{
"db": "NVD",
"id": "CVE-2023-38930"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter function. AC7 firmware, f1203 firmware, fh1205 firmware etc. Shenzhen Tenda Technology Co.,Ltd. The product contains a vulnerability related to out-of-bounds writes.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38930"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021095"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38930",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021095",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021095"
},
{
"db": "NVD",
"id": "CVE-2023-38930"
}
]
},
"id": "VAR-202308-3852",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.73276942
},
"last_update_date": "2024-01-19T23:21:34.368000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021095"
},
{
"db": "NVD",
"id": "CVE-2023-38930"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/addwifimacfilter/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38930"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021095"
},
{
"db": "NVD",
"id": "CVE-2023-38930"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021095"
},
{
"db": "NVD",
"id": "CVE-2023-38930"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021095"
},
{
"date": "2023-08-07T19:15:10.907000",
"db": "NVD",
"id": "CVE-2023-38930"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-18T06:42:00",
"db": "JVNDB",
"id": "JVNDB-2023-021095"
},
{
"date": "2023-08-09T18:05:36.363000",
"db": "NVD",
"id": "CVE-2023-38930"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 Out-of-bounds write vulnerabilities in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021095"
}
],
"trust": 0.8
}
}
VAR-202304-0458
Vulnerability from variot - Updated: 2023-12-18 14:03Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromSetSysTime function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202304-0458",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac5 firmware 15.03.06.28"
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006907"
},
{
"db": "NVD",
"id": "CVE-2023-25210"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25210"
}
]
},
"cve": "CVE-2023-25210",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-25210",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-25210",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-202304-500",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006907"
},
{
"db": "NVD",
"id": "CVE-2023-25210"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-500"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromSetSysTime function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25210"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006907"
},
{
"db": "VULMON",
"id": "CVE-2023-25210"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-25210",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006907",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202304-500",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-25210",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-25210"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006907"
},
{
"db": "NVD",
"id": "CVE-2023-25210"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-500"
}
]
},
"id": "VAR-202304-0458",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.75
},
"last_update_date": "2023-12-18T14:03:23.236000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006907"
},
{
"db": "NVD",
"id": "CVE-2023-25210"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/1/1.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-25210"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-25210/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-25210"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006907"
},
{
"db": "NVD",
"id": "CVE-2023-25210"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-500"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2023-25210"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006907"
},
{
"db": "NVD",
"id": "CVE-2023-25210"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-500"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25210"
},
{
"date": "2023-11-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-006907"
},
{
"date": "2023-04-07T02:15:07.793000",
"db": "NVD",
"id": "CVE-2023-25210"
},
{
"date": "2023-04-07T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-500"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25210"
},
{
"date": "2023-11-17T00:47:00",
"db": "JVNDB",
"id": "JVNDB-2023-006907"
},
{
"date": "2023-04-13T17:43:34.923000",
"db": "NVD",
"id": "CVE-2023-25210"
},
{
"date": "2023-04-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-500"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-500"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006907"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-500"
}
],
"trust": 0.6
}
}
VAR-202304-0584
Vulnerability from variot - Updated: 2023-12-18 14:03Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202304-0584",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac5 firmware 15.03.06.28"
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5 us ac5v1.0rtl v15.03.06.28",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-57678"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006861"
},
{
"db": "NVD",
"id": "CVE-2023-25214"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25214"
}
]
},
"cve": "CVE-2023-25214",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-57678",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-25214",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-25214",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2023-57678",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202304-502",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-57678"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006861"
},
{
"db": "NVD",
"id": "CVE-2023-25214"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-502"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25214"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006861"
},
{
"db": "CNVD",
"id": "CNVD-2023-57678"
},
{
"db": "VULMON",
"id": "CVE-2023-25214"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-25214",
"trust": 3.9
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006861",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-57678",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202304-502",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-25214",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-57678"
},
{
"db": "VULMON",
"id": "CVE-2023-25214"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006861"
},
{
"db": "NVD",
"id": "CVE-2023-25214"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-502"
}
]
},
"id": "VAR-202304-0584",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-57678"
}
],
"trust": 1.35
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-57678"
}
]
},
"last_update_date": "2023-12-18T14:03:23.104000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006861"
},
{
"db": "NVD",
"id": "CVE-2023-25214"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/4/4.md"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-25214"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-25214/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-57678"
},
{
"db": "VULMON",
"id": "CVE-2023-25214"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006861"
},
{
"db": "NVD",
"id": "CVE-2023-25214"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-502"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-57678"
},
{
"db": "VULMON",
"id": "CVE-2023-25214"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006861"
},
{
"db": "NVD",
"id": "CVE-2023-25214"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-502"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-57678"
},
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25214"
},
{
"date": "2023-11-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-006861"
},
{
"date": "2023-04-07T02:15:07.940000",
"db": "NVD",
"id": "CVE-2023-25214"
},
{
"date": "2023-04-07T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-502"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-20T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-57678"
},
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25214"
},
{
"date": "2023-11-16T07:08:00",
"db": "JVNDB",
"id": "JVNDB-2023-006861"
},
{
"date": "2023-04-13T17:44:21.567000",
"db": "NVD",
"id": "CVE-2023-25214"
},
{
"date": "2023-04-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-502"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-502"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006861"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-502"
}
],
"trust": 0.6
}
}
VAR-202307-1306
Vulnerability from variot - Updated: 2023-12-18 13:59Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202307-1306",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "3.0"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0"
},
{
"model": "ac7",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0"
},
{
"model": "f1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0br"
},
{
"model": "fh1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.2.0.19_en"
},
{
"model": "f1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.2.0.20\\(408\\)"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0"
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37716"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:f1202_firmware:1.2.0.20\\(408\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.19_en:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:f1202_firmware:1.0br:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac10_firmware:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac1206_firmware:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac7_firmware:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac9_firmware:3.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37716"
}
]
},
"cve": "CVE-2023-37716",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-37716",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-202307-1255",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37716"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1255"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromNatStaticSetting",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37716"
},
{
"db": "VULMON",
"id": "CVE-2023-37716"
}
],
"trust": 0.99
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-37716",
"trust": 1.7
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1255",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-37716",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-37716"
},
{
"db": "NVD",
"id": "CVE-2023-37716"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1255"
}
]
},
"id": "VAR-202307-1306",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.5516548666666666
},
"last_update_date": "2023-12-18T13:59:00.602000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37716"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromnatstaticsetting/report.md"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-37716/"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-37716"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-37716"
},
{
"db": "NVD",
"id": "CVE-2023-37716"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1255"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2023-37716"
},
{
"db": "NVD",
"id": "CVE-2023-37716"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1255"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-14T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37716"
},
{
"date": "2023-07-14T00:15:09.430000",
"db": "NVD",
"id": "CVE-2023-37716"
},
{
"date": "2023-07-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-1255"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-14T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37716"
},
{
"date": "2023-07-21T14:33:30.690000",
"db": "NVD",
"id": "CVE-2023-37716"
},
{
"date": "2023-07-24T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-1255"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1255"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda F1202 Buffer error vulnerability",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1255"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1255"
}
],
"trust": 0.6
}
}
VAR-202304-0527
Vulnerability from variot - Updated: 2023-12-18 13:50Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202304-0527",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac5 firmware 15.03.06.28"
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5 us ac5v1.0rtl v15.03.06.28",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-57679"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006860"
},
{
"db": "NVD",
"id": "CVE-2023-25215"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25215"
}
]
},
"cve": "CVE-2023-25215",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-57679",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-25215",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-25215",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2023-57679",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202304-497",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-57679"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006860"
},
{
"db": "NVD",
"id": "CVE-2023-25215"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-497"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25215"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006860"
},
{
"db": "CNVD",
"id": "CNVD-2023-57679"
},
{
"db": "VULMON",
"id": "CVE-2023-25215"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-25215",
"trust": 3.9
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006860",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-57679",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202304-497",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-25215",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-57679"
},
{
"db": "VULMON",
"id": "CVE-2023-25215"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006860"
},
{
"db": "NVD",
"id": "CVE-2023-25215"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-497"
}
]
},
"id": "VAR-202304-0527",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-57679"
}
],
"trust": 1.35
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-57679"
}
]
},
"last_update_date": "2023-12-18T13:50:33.892000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006860"
},
{
"db": "NVD",
"id": "CVE-2023-25215"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/3/3.md"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-25215"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-25215/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-57679"
},
{
"db": "VULMON",
"id": "CVE-2023-25215"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006860"
},
{
"db": "NVD",
"id": "CVE-2023-25215"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-497"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-57679"
},
{
"db": "VULMON",
"id": "CVE-2023-25215"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006860"
},
{
"db": "NVD",
"id": "CVE-2023-25215"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-497"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-57679"
},
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25215"
},
{
"date": "2023-11-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-006860"
},
{
"date": "2023-04-07T02:15:07.980000",
"db": "NVD",
"id": "CVE-2023-25215"
},
{
"date": "2023-04-07T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-497"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-20T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-57679"
},
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25215"
},
{
"date": "2023-11-16T07:08:00",
"db": "JVNDB",
"id": "JVNDB-2023-006860"
},
{
"date": "2023-04-13T17:44:35.293000",
"db": "NVD",
"id": "CVE-2023-25215"
},
{
"date": "2023-04-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-497"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-497"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006860"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-497"
}
],
"trust": 0.6
}
}
VAR-202304-0528
Vulnerability from variot - Updated: 2023-12-18 13:36Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the add_white_node function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202304-0528",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac5 firmware 15.03.06.28"
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006855"
},
{
"db": "NVD",
"id": "CVE-2023-25220"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25220"
}
]
},
"cve": "CVE-2023-25220",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-25220",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-25220",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-202304-492",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006855"
},
{
"db": "NVD",
"id": "CVE-2023-25220"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-492"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the add_white_node function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25220"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006855"
},
{
"db": "VULMON",
"id": "CVE-2023-25220"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-25220",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006855",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202304-492",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-25220",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-25220"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006855"
},
{
"db": "NVD",
"id": "CVE-2023-25220"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-492"
}
]
},
"id": "VAR-202304-0528",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.75
},
"last_update_date": "2023-12-18T13:36:22.523000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006855"
},
{
"db": "NVD",
"id": "CVE-2023-25220"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"trust": 2.5,
"url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/7/7.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-25220"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-25220/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-25220"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006855"
},
{
"db": "NVD",
"id": "CVE-2023-25220"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-492"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2023-25220"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006855"
},
{
"db": "NVD",
"id": "CVE-2023-25220"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-492"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25220"
},
{
"date": "2023-11-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-006855"
},
{
"date": "2023-04-07T02:15:08.177000",
"db": "NVD",
"id": "CVE-2023-25220"
},
{
"date": "2023-04-07T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-492"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25220"
},
{
"date": "2023-11-16T07:04:00",
"db": "JVNDB",
"id": "JVNDB-2023-006855"
},
{
"date": "2023-04-13T17:45:17.310000",
"db": "NVD",
"id": "CVE-2023-25220"
},
{
"date": "2023-04-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-492"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-492"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006855"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-492"
}
],
"trust": 0.6
}
}
VAR-202304-0586
Vulnerability from variot - Updated: 2023-12-18 13:16Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202304-0586",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac5 firmware 15.03.06.28"
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006857"
},
{
"db": "NVD",
"id": "CVE-2023-25218"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25218"
}
]
},
"cve": "CVE-2023-25218",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-25218",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-25218",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-202304-493",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006857"
},
{
"db": "NVD",
"id": "CVE-2023-25218"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-493"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25218"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006857"
},
{
"db": "VULMON",
"id": "CVE-2023-25218"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-25218",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006857",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202304-493",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-25218",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-25218"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006857"
},
{
"db": "NVD",
"id": "CVE-2023-25218"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-493"
}
]
},
"id": "VAR-202304-0586",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.75
},
"last_update_date": "2023-12-18T13:16:47.151000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006857"
},
{
"db": "NVD",
"id": "CVE-2023-25218"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://www.dlink.com/en/security-bulletin/"
},
{
"trust": 2.5,
"url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/8/8.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-25218"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-25218/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-25218"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006857"
},
{
"db": "NVD",
"id": "CVE-2023-25218"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-493"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2023-25218"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006857"
},
{
"db": "NVD",
"id": "CVE-2023-25218"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-493"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25218"
},
{
"date": "2023-11-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-006857"
},
{
"date": "2023-04-07T02:15:08.100000",
"db": "NVD",
"id": "CVE-2023-25218"
},
{
"date": "2023-04-07T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-493"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25218"
},
{
"date": "2023-11-16T07:06:00",
"db": "JVNDB",
"id": "JVNDB-2023-006857"
},
{
"date": "2023-04-13T17:45:02.777000",
"db": "NVD",
"id": "CVE-2023-25218"
},
{
"date": "2023-04-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-493"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-493"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006857"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-493"
}
],
"trust": 0.6
}
}
VAR-202305-1572
Vulnerability from variot - Updated: 2023-12-18 13:16Tenda AC5 router V15.03.06.28 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac. Shenzhen Tenda Technology Co.,Ltd. of AC5 There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. An attacker could exploit this vulnerability to cause arbitrary code execution
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202305-1572",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac5 firmware 15.03.06.28"
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v15.03.06.28"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-40600"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-010288"
},
{
"db": "NVD",
"id": "CVE-2023-31587"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-31587"
}
]
},
"cve": "CVE-2023-31587",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-40600",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-31587",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-31587",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2023-40600",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202305-1519",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-40600"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-010288"
},
{
"db": "NVD",
"id": "CVE-2023-31587"
},
{
"db": "CNNVD",
"id": "CNNVD-202305-1519"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC5 router V15.03.06.28 was discovered to contain a remote code execution (RCE) vulnerability via the Mac parameter at ip/goform/WriteFacMac. Shenzhen Tenda Technology Co.,Ltd. of AC5 There are unspecified vulnerabilities in the firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. An attacker could exploit this vulnerability to cause arbitrary code execution",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-31587"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-010288"
},
{
"db": "CNVD",
"id": "CNVD-2023-40600"
},
{
"db": "VULMON",
"id": "CVE-2023-31587"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-31587",
"trust": 3.9
},
{
"db": "JVNDB",
"id": "JVNDB-2023-010288",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-40600",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202305-1519",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-31587",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-40600"
},
{
"db": "VULMON",
"id": "CVE-2023-31587"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-010288"
},
{
"db": "NVD",
"id": "CVE-2023-31587"
},
{
"db": "CNNVD",
"id": "CNNVD-202305-1519"
}
]
},
"id": "VAR-202305-1572",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-40600"
}
],
"trust": 1.35
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-40600"
}
]
},
"last_update_date": "2023-12-18T13:16:40.498000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-010288"
},
{
"db": "NVD",
"id": "CVE-2023-31587"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.1,
"url": "https://www.tenda.com.cn/download/detail-2740.html"
},
{
"trust": 2.5,
"url": "https://www.tenda.com.cn/product/ac5.html"
},
{
"trust": 2.5,
"url": "https://github.com/yanbushuang/cve/blob/main/tendaac5.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-31587"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-31587/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-40600"
},
{
"db": "VULMON",
"id": "CVE-2023-31587"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-010288"
},
{
"db": "NVD",
"id": "CVE-2023-31587"
},
{
"db": "CNNVD",
"id": "CNNVD-202305-1519"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-40600"
},
{
"db": "VULMON",
"id": "CVE-2023-31587"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-010288"
},
{
"db": "NVD",
"id": "CVE-2023-31587"
},
{
"db": "CNNVD",
"id": "CNNVD-202305-1519"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-05-24T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-40600"
},
{
"date": "2023-05-16T00:00:00",
"db": "VULMON",
"id": "CVE-2023-31587"
},
{
"date": "2023-12-08T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-010288"
},
{
"date": "2023-05-16T15:15:09.277000",
"db": "NVD",
"id": "CVE-2023-31587"
},
{
"date": "2023-05-16T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202305-1519"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-05-24T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-40600"
},
{
"date": "2023-05-16T00:00:00",
"db": "VULMON",
"id": "CVE-2023-31587"
},
{
"date": "2023-12-08T05:33:00",
"db": "JVNDB",
"id": "JVNDB-2023-010288"
},
{
"date": "2023-05-22T17:20:22.587000",
"db": "NVD",
"id": "CVE-2023-31587"
},
{
"date": "2023-05-23T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202305-1519"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202305-1519"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Firmware vulnerabilities",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-010288"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202305-1519"
}
],
"trust": 0.6
}
}
VAR-202304-0459
Vulnerability from variot - Updated: 2023-12-18 13:11Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromDhcpListClient function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202304-0459",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac5 firmware 15.03.06.28"
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006856"
},
{
"db": "NVD",
"id": "CVE-2023-25219"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25219"
}
]
},
"cve": "CVE-2023-25219",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-25219",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-25219",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-202304-496",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006856"
},
{
"db": "NVD",
"id": "CVE-2023-25219"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-496"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromDhcpListClient function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25219"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006856"
},
{
"db": "VULMON",
"id": "CVE-2023-25219"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-25219",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006856",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202304-496",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-25219",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-25219"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006856"
},
{
"db": "NVD",
"id": "CVE-2023-25219"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-496"
}
]
},
"id": "VAR-202304-0459",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.75
},
"last_update_date": "2023-12-18T13:11:28.182000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006856"
},
{
"db": "NVD",
"id": "CVE-2023-25219"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/11/11.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-25219"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-25219/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-25219"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006856"
},
{
"db": "NVD",
"id": "CVE-2023-25219"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-496"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2023-25219"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006856"
},
{
"db": "NVD",
"id": "CVE-2023-25219"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-496"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25219"
},
{
"date": "2023-11-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-006856"
},
{
"date": "2023-04-07T02:15:08.140000",
"db": "NVD",
"id": "CVE-2023-25219"
},
{
"date": "2023-04-07T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-496"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25219"
},
{
"date": "2023-11-16T07:05:00",
"db": "JVNDB",
"id": "JVNDB-2023-006856"
},
{
"date": "2023-04-13T17:45:10.830000",
"db": "NVD",
"id": "CVE-2023-25219"
},
{
"date": "2023-04-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-496"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-496"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006856"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-496"
}
],
"trust": 0.6
}
}
VAR-202304-0504
Vulnerability from variot - Updated: 2023-12-18 13:00Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202304-0504",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac5 firmware 15.03.06.28"
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006859"
},
{
"db": "NVD",
"id": "CVE-2023-25216"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25216"
}
]
},
"cve": "CVE-2023-25216",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-25216",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-25216",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-202304-494",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006859"
},
{
"db": "NVD",
"id": "CVE-2023-25216"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-494"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25216"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006859"
},
{
"db": "VULMON",
"id": "CVE-2023-25216"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-25216",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006859",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202304-494",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-25216",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-25216"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006859"
},
{
"db": "NVD",
"id": "CVE-2023-25216"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-494"
}
]
},
"id": "VAR-202304-0504",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.75
},
"last_update_date": "2023-12-18T13:00:11.971000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006859"
},
{
"db": "NVD",
"id": "CVE-2023-25216"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/9/9.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-25216"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-25216/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-25216"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006859"
},
{
"db": "NVD",
"id": "CVE-2023-25216"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-494"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2023-25216"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006859"
},
{
"db": "NVD",
"id": "CVE-2023-25216"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-494"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25216"
},
{
"date": "2023-11-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-006859"
},
{
"date": "2023-04-07T02:15:08.017000",
"db": "NVD",
"id": "CVE-2023-25216"
},
{
"date": "2023-04-07T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-494"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25216"
},
{
"date": "2023-11-16T07:07:00",
"db": "JVNDB",
"id": "JVNDB-2023-006859"
},
{
"date": "2023-04-13T17:44:42.100000",
"db": "NVD",
"id": "CVE-2023-25216"
},
{
"date": "2023-04-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-494"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-494"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006859"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-494"
}
],
"trust": 0.6
}
}
VAR-202304-0585
Vulnerability from variot - Updated: 2023-12-18 12:54Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromSetWirelessRepeat function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202304-0585",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac5 firmware 15.03.06.28"
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006863"
},
{
"db": "NVD",
"id": "CVE-2023-25212"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25212"
}
]
},
"cve": "CVE-2023-25212",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-25212",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-25212",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-202304-498",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006863"
},
{
"db": "NVD",
"id": "CVE-2023-25212"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-498"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the fromSetWirelessRepeat function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25212"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006863"
},
{
"db": "VULMON",
"id": "CVE-2023-25212"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-25212",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006863",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202304-498",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-25212",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-25212"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006863"
},
{
"db": "NVD",
"id": "CVE-2023-25212"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-498"
}
]
},
"id": "VAR-202304-0585",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.75
},
"last_update_date": "2023-12-18T12:54:26.360000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006863"
},
{
"db": "NVD",
"id": "CVE-2023-25212"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/6/6.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-25212"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-25212/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-25212"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006863"
},
{
"db": "NVD",
"id": "CVE-2023-25212"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-498"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2023-25212"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006863"
},
{
"db": "NVD",
"id": "CVE-2023-25212"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-498"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25212"
},
{
"date": "2023-11-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-006863"
},
{
"date": "2023-04-07T02:15:07.867000",
"db": "NVD",
"id": "CVE-2023-25212"
},
{
"date": "2023-04-07T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-498"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25212"
},
{
"date": "2023-11-16T07:10:00",
"db": "JVNDB",
"id": "JVNDB-2023-006863"
},
{
"date": "2023-04-13T17:43:57.860000",
"db": "NVD",
"id": "CVE-2023-25212"
},
{
"date": "2023-04-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-498"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-498"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006863"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-498"
}
],
"trust": 0.6
}
}
VAR-202304-0768
Vulnerability from variot - Updated: 2023-12-18 12:41Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the formWifiBasicSet function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202304-0768",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac5 firmware 15.03.06.28"
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006858"
},
{
"db": "NVD",
"id": "CVE-2023-25217"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25217"
}
]
},
"cve": "CVE-2023-25217",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-25217",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-25217",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-202304-495",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006858"
},
{
"db": "NVD",
"id": "CVE-2023-25217"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-495"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the formWifiBasicSet function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25217"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006858"
},
{
"db": "VULMON",
"id": "CVE-2023-25217"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-25217",
"trust": 3.3
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006858",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202304-495",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-25217",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-25217"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006858"
},
{
"db": "NVD",
"id": "CVE-2023-25217"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-495"
}
]
},
"id": "VAR-202304-0768",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.75
},
"last_update_date": "2023-12-18T12:41:13.898000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006858"
},
{
"db": "NVD",
"id": "CVE-2023-25217"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/10/10.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-25217"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-25217/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-25217"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006858"
},
{
"db": "NVD",
"id": "CVE-2023-25217"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-495"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2023-25217"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006858"
},
{
"db": "NVD",
"id": "CVE-2023-25217"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-495"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25217"
},
{
"date": "2023-11-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-006858"
},
{
"date": "2023-04-07T02:15:08.053000",
"db": "NVD",
"id": "CVE-2023-25217"
},
{
"date": "2023-04-07T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-495"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25217"
},
{
"date": "2023-11-16T07:06:00",
"db": "JVNDB",
"id": "JVNDB-2023-006858"
},
{
"date": "2023-04-13T17:44:51.210000",
"db": "NVD",
"id": "CVE-2023-25217"
},
{
"date": "2023-04-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-495"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-495"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006858"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-495"
}
],
"trust": 0.6
}
}
VAR-202307-1183
Vulnerability from variot - Updated: 2023-12-18 12:41Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202307-1183",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0"
},
{
"model": "ac9",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "3.0"
},
{
"model": "ac10",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0"
},
{
"model": "ac7",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0"
},
{
"model": "f1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0br"
},
{
"model": "fh1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.2.0.19_en"
},
{
"model": "f1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.2.0.20\\(408\\)"
},
{
"model": "ac1206",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0"
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37717"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:f1202_firmware:1.2.0.20\\(408\\):*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.19_en:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:f1202_firmware:1.0br:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:f1202:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac10_firmware:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac10:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac1206_firmware:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac1206:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac7_firmware:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac7:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac9_firmware:3.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac9:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37717"
}
]
},
"cve": "CVE-2023-37717",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-37717",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-202307-1259",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37717"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1259"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda F1202 V1.0BR_V1.2.0.20(408) and FH1202_V1.2.0.19_EN, AC10 V1.0, AC1206 V1.0, AC7 V1.0, AC5 V1.0, and AC9 V3.0 were discovered to contain a stack overflow in the page parameter in the function fromDhcpListClient",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37717"
},
{
"db": "VULMON",
"id": "CVE-2023-37717"
}
],
"trust": 0.99
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-37717",
"trust": 1.7
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1259",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-37717",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-37717"
},
{
"db": "NVD",
"id": "CVE-2023-37717"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1259"
}
]
},
"id": "VAR-202307-1183",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.5516548666666666
},
"last_update_date": "2023-12-18T12:41:02.610000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Tenda F1202 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=247158"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1259"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37717"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromdhcplistclient/repot.md"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-37717/"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-37717"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-37717"
},
{
"db": "NVD",
"id": "CVE-2023-37717"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1259"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2023-37717"
},
{
"db": "NVD",
"id": "CVE-2023-37717"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1259"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-14T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37717"
},
{
"date": "2023-07-14T00:15:09.477000",
"db": "NVD",
"id": "CVE-2023-37717"
},
{
"date": "2023-07-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-1259"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-14T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37717"
},
{
"date": "2023-07-21T14:31:56.167000",
"db": "NVD",
"id": "CVE-2023-37717"
},
{
"date": "2023-07-24T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-1259"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1259"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda F1202 Buffer error vulnerability",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1259"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1259"
}
],
"trust": 0.6
}
}
VAR-202304-0599
Vulnerability from variot - Updated: 2023-12-18 12:33Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the R7WebsSecurityHandler function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202304-0599",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ac5",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "15.03.06.28"
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "ac5 firmware 15.03.06.28"
},
{
"model": "ac5",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "ac5 us ac5v1.0rtl v15.03.06.28",
"scope": null,
"trust": 0.6,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-57680"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006906"
},
{
"db": "NVD",
"id": "CVE-2023-25211"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:tenda:ac5_firmware:15.03.06.28:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:tenda:ac5:1.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25211"
}
]
},
"cve": "CVE-2023-25211",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-57680",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-25211",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2023-25211",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNVD",
"id": "CNVD-2023-57680",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202304-499",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-57680"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006906"
},
{
"db": "NVD",
"id": "CVE-2023-25211"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-499"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 was discovered to contain a stack overflow via the R7WebsSecurityHandler function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. Shenzhen Tenda Technology Co.,Ltd. of AC5 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-25211"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006906"
},
{
"db": "CNVD",
"id": "CNVD-2023-57680"
},
{
"db": "VULMON",
"id": "CVE-2023-25211"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-25211",
"trust": 3.9
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006906",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-57680",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202304-499",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-25211",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-57680"
},
{
"db": "VULMON",
"id": "CVE-2023-25211"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006906"
},
{
"db": "NVD",
"id": "CVE-2023-25211"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-499"
}
]
},
"id": "VAR-202304-0599",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-57680"
}
],
"trust": 1.35
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-57680"
}
]
},
"last_update_date": "2023-12-18T12:33:51.028000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006906"
},
{
"db": "NVD",
"id": "CVE-2023-25211"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.5,
"url": "https://github.com/drizzlingsun/tenda/blob/main/ac5/2/2.md"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-25211"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-25211/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-57680"
},
{
"db": "VULMON",
"id": "CVE-2023-25211"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006906"
},
{
"db": "NVD",
"id": "CVE-2023-25211"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-499"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-57680"
},
{
"db": "VULMON",
"id": "CVE-2023-25211"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-006906"
},
{
"db": "NVD",
"id": "CVE-2023-25211"
},
{
"db": "CNNVD",
"id": "CNNVD-202304-499"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-19T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-57680"
},
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25211"
},
{
"date": "2023-11-17T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-006906"
},
{
"date": "2023-04-07T02:15:07.827000",
"db": "NVD",
"id": "CVE-2023-25211"
},
{
"date": "2023-04-07T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-499"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-20T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-57680"
},
{
"date": "2023-04-07T00:00:00",
"db": "VULMON",
"id": "CVE-2023-25211"
},
{
"date": "2023-11-17T00:47:00",
"db": "JVNDB",
"id": "JVNDB-2023-006906"
},
{
"date": "2023-04-13T17:43:49.710000",
"db": "NVD",
"id": "CVE-2023-25211"
},
{
"date": "2023-04-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202304-499"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-499"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0AC5\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-006906"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202304-499"
}
],
"trust": 0.6
}
}