All the vulnerabilites related to iconics - analytix
var-202201-0603
Vulnerability from variot
Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products. Mitsubishi Electric products and multiple ICONICS There are unspecified vulnerabilities in the product.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Mitsubishi Electric MC Works64 is a set of data acquisition and monitoring and control system (SCADA) of Japan's Mitsubishi Electric (Mitsubishi Electric).
A security vulnerability exists in Mitsubishi Electric MC Works64 that originates in the ICONICS and Mitsubishi Electric ICONICS product suites. The FrameWorX server in the Mitsubishi Electric MC Works64 product could allow an attacker to exploit the vulnerability to open a WebSocket endpoint (port 80 or 443) when bypassing GENESIS64 MC Works64 security. No detailed vulnerability details are currently provided
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202201-0603", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "mc works64", "scope": "gte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "10.95.201.23" }, { "model": "mc works64", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "10.95.210.01" }, { "model": "mobilehmi", "scope": "lte", "trust": 1.0, "vendor": "iconics", "version": "10.97" }, { "model": "hyper historian", "scope": "lte", "trust": 1.0, "vendor": "iconics", "version": "10.97" }, { "model": "genesis64", "scope": "lte", "trust": 1.0, "vendor": "iconics", "version": "10.97" }, { "model": "hyper historian", "scope": "gte", "trust": 1.0, "vendor": "iconics", "version": "10.95.3" }, { "model": "genesis64", "scope": "gte", "trust": 1.0, "vendor": "iconics", "version": "10.95.3" }, { "model": "mobilehmi", "scope": "gte", "trust": 1.0, "vendor": "iconics", "version": "10.95.3" }, { "model": "analytix", "scope": "gte", "trust": 1.0, "vendor": "iconics", "version": "10.95.3" }, { "model": "analytix", "scope": "lte", "trust": 1.0, "vendor": "iconics", "version": "10.97" }, { "model": "hyper historian", "scope": null, "trust": 0.8, "vendor": "iconics", "version": null }, { "model": "mc works64", "scope": "eq", "trust": 0.8, "vendor": "\u4e09\u83f1\u96fb\u6a5f", "version": "4.00a (10.95.201.23) to 4.04e (10.95.210.01)" }, { "model": "mobilehmi", "scope": null, "trust": 0.8, "vendor": "iconics", "version": null }, { "model": "analytix", "scope": null, "trust": 0.8, "vendor": "iconics", "version": null }, { "model": "genesis 64", "scope": null, "trust": 0.8, "vendor": "iconics", "version": null }, { "model": "electric mc works64", "scope": "gte", "trust": 0.6, "vendor": "mitsubishi", "version": "10.95.201.23,\u003c=10.95.210.01" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-08358" }, { "db": "JVNDB", "id": "JVNDB-2022-003883" }, { "db": "NVD", "id": "CVE-2022-23128" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:iconics:analytix:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "10.97", "versionStartIncluding": "10.95.3", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "10.97", "versionStartIncluding": "10.95.3", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:iconics:hyper_historian:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "10.97", "versionStartIncluding": "10.95.3", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:iconics:mobilehmi:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "10.97", "versionStartIncluding": "10.95.3", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "10.95.210.01", "versionStartIncluding": "10.95.201.23", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2022-23128" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "ICONICS and Mitsubishi Electric reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-202201-1829" } ], "trust": 0.6 }, "cve": "CVE-2022-23128", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 7.5, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2022-23128", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2022-08358", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 9.8, "baseSeverity": "Critical", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2022-23128", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2022-23128", "trust": 1.8, "value": "CRITICAL" }, { "author": "CNVD", "id": "CNVD-2022-08358", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202201-1829", "trust": 0.6, "value": "CRITICAL" }, { "author": "VULMON", "id": "CVE-2022-23128", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-08358" }, { "db": "VULMON", "id": "CVE-2022-23128" }, { "db": "JVNDB", "id": "JVNDB-2022-003883" }, { "db": "CNNVD", "id": "CNNVD-202201-1829" }, { "db": "NVD", "id": "CVE-2022-23128" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products. Mitsubishi Electric products and multiple ICONICS There are unspecified vulnerabilities in the product.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Mitsubishi Electric MC Works64 is a set of data acquisition and monitoring and control system (SCADA) of Japan\u0027s Mitsubishi Electric (Mitsubishi Electric). \n\r\n\r\nA security vulnerability exists in Mitsubishi Electric MC Works64 that originates in the ICONICS and Mitsubishi Electric ICONICS product suites. The FrameWorX server in the Mitsubishi Electric MC Works64 product could allow an attacker to exploit the vulnerability to open a WebSocket endpoint (port 80 or 443) when bypassing GENESIS64 MC Works64 security. No detailed vulnerability details are currently provided", "sources": [ { "db": "NVD", "id": "CVE-2022-23128" }, { "db": "JVNDB", "id": "JVNDB-2022-003883" }, { "db": "CNVD", "id": "CNVD-2022-08358" }, { "db": "VULMON", "id": "CVE-2022-23128" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2022-23128", "trust": 3.9 }, { "db": "ICS CERT", "id": "ICSA-22-020-01", "trust": 3.1 }, { "db": "JVN", "id": "JVNVU95403720", "trust": 2.5 }, { "db": "JVNDB", "id": "JVNDB-2022-003883", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2022-08358", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2022.0311", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2022012108", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202201-1829", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2022-23128", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-08358" }, { "db": "VULMON", "id": "CVE-2022-23128" }, { "db": "JVNDB", "id": "JVNDB-2022-003883" }, { "db": "CNNVD", "id": "CNNVD-202201-1829" }, { "db": "NVD", "id": "CVE-2022-23128" } ] }, "id": "VAR-202201-0603", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2022-08358" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-08358" } ] }, "last_update_date": "2024-02-13T22:46:25.925000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Top\u00a0Page Mitsubishi Electric Mitsubishi\u00a0Electric\u00a0Corporation", "trust": 0.8, "url": "https://iconics.com/" }, { "title": "Patch for Unknown Vulnerability in Mitsubishi Electric MC Works64", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/317671" }, { "title": "Mitsubishi Electric MC Works64 Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=179152" }, { "title": "CVE-2022-XXXX", "trust": 0.1, "url": "https://github.com/alphabugx/cve-2022-23305 " }, { "title": "CVE-2022-XXXX", "trust": 0.1, "url": "https://github.com/alphabugx/cve-2022-rce " } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-08358" }, { "db": "VULMON", "id": "CVE-2022-23128" }, { "db": "JVNDB", "id": "JVNDB-2022-003883" }, { "db": "CNNVD", "id": "CNNVD-202201-1829" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "NVD-CWE-Other", "trust": 1.0 }, { "problemtype": "others (CWE-Other) [NVD evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-003883" }, { "db": "NVD", "id": "CVE-2022-23128" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.8, "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01" }, { "trust": 1.7, "url": "https://jvn.jp/vu/jvnvu95403720/index.html" }, { "trust": 1.7, "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-026_en.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2022-23128" }, { "trust": 1.2, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-020-01" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu95403720/" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-020-01" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2022.0311" }, { "trust": 0.6, "url": "https://vigilance.fr/vulnerability/iconics-genesis64-four-vulnerabilities-37339" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022012108" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://github.com/alphabugx/cve-2022-23305" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2022-08358" }, { "db": "VULMON", "id": "CVE-2022-23128" }, { "db": "JVNDB", "id": "JVNDB-2022-003883" }, { "db": "CNNVD", "id": "CNNVD-202201-1829" }, { "db": "NVD", "id": "CVE-2022-23128" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2022-08358" }, { "db": "VULMON", "id": "CVE-2022-23128" }, { "db": "JVNDB", "id": "JVNDB-2022-003883" }, { "db": "CNNVD", "id": "CNNVD-202201-1829" }, { "db": "NVD", "id": "CVE-2022-23128" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-02-05T00:00:00", "db": "CNVD", "id": "CNVD-2022-08358" }, { "date": "2022-01-21T00:00:00", "db": "VULMON", "id": "CVE-2022-23128" }, { "date": "2023-03-10T00:00:00", "db": "JVNDB", "id": "JVNDB-2022-003883" }, { "date": "2022-01-20T00:00:00", "db": "CNNVD", "id": "CNNVD-202201-1829" }, { "date": "2022-01-21T19:15:09.977000", "db": "NVD", "id": "CVE-2022-23128" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2022-06-13T00:00:00", "db": "CNVD", "id": "CNVD-2022-08358" }, { "date": "2022-01-27T00:00:00", "db": "VULMON", "id": "CVE-2022-23128" }, { "date": "2023-03-10T03:20:00", "db": "JVNDB", "id": "JVNDB-2022-003883" }, { "date": "2022-02-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202201-1829" }, { "date": "2022-01-27T20:20:33.137000", "db": "NVD", "id": "CVE-2022-23128" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-202201-1829" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Mitsubishi Electric products and multiple \u00a0ICONICS\u00a0 Product vulnerabilities", "sources": [ { "db": "JVNDB", "id": "JVNDB-2022-003883" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "other", "sources": [ { "db": "CNNVD", "id": "CNNVD-202201-1829" } ], "trust": 0.6 } }
Vulnerability from fkie_nvd
▼ | URL | Tags | |
---|---|---|---|
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://jvn.jp/vu/JVNVU95403720/index.html | Mitigation, Third Party Advisory, VDB Entry | |
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01 | Mitigation, Third Party Advisory, US Government Resource, VDB Entry | |
Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-026_en.pdf | Mitigation, Vendor Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://jvn.jp/vu/JVNVU95403720/index.html | Mitigation, Third Party Advisory, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01 | Mitigation, Third Party Advisory, US Government Resource, VDB Entry | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-026_en.pdf | Mitigation, Vendor Advisory |
Vendor | Product | Version | |
---|---|---|---|
iconics | analytix | * | |
iconics | genesis64 | * | |
iconics | hyper_historian | * | |
iconics | mobilehmi | * | |
mitsubishielectric | mc_works64 | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:iconics:analytix:*:*:*:*:*:*:*:*", "matchCriteriaId": "9D4A6919-8FA2-4D81-991F-1960EA3F0DE1", "versionEndIncluding": "10.97", "versionStartIncluding": "10.95.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:iconics:genesis64:*:*:*:*:*:*:*:*", "matchCriteriaId": "1B337BB0-925C-4B18-B4FD-CF786F47642F", "versionEndIncluding": "10.97", "versionStartIncluding": "10.95.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:iconics:hyper_historian:*:*:*:*:*:*:*:*", "matchCriteriaId": "170EE68A-2E3C-441B-98E3-7CFD238E80D1", "versionEndIncluding": "10.97", "versionStartIncluding": "10.95.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:iconics:mobilehmi:*:*:*:*:*:*:*:*", "matchCriteriaId": "7C0D55FF-E640-48D1-8B0D-2FB036E897EB", "versionEndIncluding": "10.97", "versionStartIncluding": "10.95.3", "vulnerable": true }, { "criteria": "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*", "matchCriteriaId": "AD31D401-1AD5-4D75-83B8-648AA794E557", "versionEndIncluding": "10.95.210.01", "versionStartIncluding": "10.95.201.23", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products." }, { "lang": "es", "value": "Una vulnerabilidad \"Incomplete List of Disallowed Inputs\" en Mitsubishi Electric MC Works64 versiones 4.00A (10.95.201.23) a 4.04E (10.95.210.01), ICONICS GENESIS64 versiones 10.95.3 a 10.97, ICONICS Hyper Historian versiones 10.95.3 a 10.97, ICONICS AnalytiX versiones 10.95.3 a 10.97 e ICONICS MobileHMI versiones 10. 95.3 a 10.97 permite a un atacante remoto no autenticado omitir la autenticaci\u00f3n de MC Works64, GENESIS64, Hyper Historian, AnalytiX y MobileHMI, y conseguir acceso no autorizado a los productos, mediante el env\u00edo de paquetes WebSocket especialmente dise\u00f1ados al servidor FrameWorX, una de las funciones de los productos" } ], "id": "CVE-2022-23128", "lastModified": "2024-11-21T06:48:03.407", "metrics": { "cvssMetricV2": [ { "acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 7.5, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false } ], "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2022-01-21T19:15:09.977", "references": [ { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Mitigation", "Third Party Advisory", "VDB Entry" ], "url": "https://jvn.jp/vu/JVNVU95403720/index.html" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Mitigation", "Third Party Advisory", "US Government Resource", "VDB Entry" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01" }, { "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-026_en.pdf" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Third Party Advisory", "VDB Entry" ], "url": "https://jvn.jp/vu/JVNVU95403720/index.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Third Party Advisory", "US Government Resource", "VDB Entry" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-026_en.pdf" } ], "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-Other" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
cve-2022-23128
Vulnerability from cvelistv5
▼ | URL | Tags |
---|---|---|
https://jvn.jp/vu/JVNVU95403720/index.html | x_refsource_MISC | |
https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01 | x_refsource_MISC | |
https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-026_en.pdf | x_refsource_MISC |
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | Mitsubishi Electric MC Works64; ICONICS GENESIS64; ICONICS Hyper Historian; ICONICS AnalytiX; ICONICS MobileHMI |
Version: Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01) Version: ICONICS GENESIS64 versions 10.95.3 to 10.97 Version: ICONICS Hyper Historian versions 10.95.3 to 10.97 Version: ICONICS AnalytiX versions 10.95.3 to 10.97 Version: ICONICS MobileHMI versions 10.95.3 to 10.97 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T03:36:19.863Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://jvn.jp/vu/JVNVU95403720/index.html" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-026_en.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Mitsubishi Electric MC Works64; ICONICS GENESIS64; ICONICS Hyper Historian; ICONICS AnalytiX; ICONICS MobileHMI", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01)" }, { "status": "affected", "version": "ICONICS GENESIS64 versions 10.95.3 to 10.97" }, { "status": "affected", "version": "ICONICS Hyper Historian versions 10.95.3 to 10.97" }, { "status": "affected", "version": "ICONICS AnalytiX versions 10.95.3 to 10.97" }, { "status": "affected", "version": "ICONICS MobileHMI versions 10.95.3 to 10.97" } ] } ], "descriptions": [ { "lang": "en", "value": "Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products." } ], "problemTypes": [ { "descriptions": [ { "description": "Incomplete List of Disallowed Inputs", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-01-21T18:17:33", "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "shortName": "Mitsubishi" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://jvn.jp/vu/JVNVU95403720/index.html" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-026_en.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp", "ID": "CVE-2022-23128", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Mitsubishi Electric MC Works64; ICONICS GENESIS64; ICONICS Hyper Historian; ICONICS AnalytiX; ICONICS MobileHMI", "version": { "version_data": [ { "version_value": "Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01)" }, { "version_value": "ICONICS GENESIS64 versions 10.95.3 to 10.97" }, { "version_value": "ICONICS Hyper Historian versions 10.95.3 to 10.97" }, { "version_value": "ICONICS AnalytiX versions 10.95.3 to 10.97" }, { "version_value": "ICONICS MobileHMI versions 10.95.3 to 10.97" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Incomplete List of Disallowed Inputs" } ] } ] }, "references": { "reference_data": [ { "name": "https://jvn.jp/vu/JVNVU95403720/index.html", "refsource": "MISC", "url": "https://jvn.jp/vu/JVNVU95403720/index.html" }, { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01", "refsource": "MISC", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01" }, { "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-026_en.pdf", "refsource": "MISC", "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-026_en.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad", "assignerShortName": "Mitsubishi", "cveId": "CVE-2022-23128", "datePublished": "2022-01-21T18:17:33", "dateReserved": "2022-01-11T00:00:00", "dateUpdated": "2024-08-03T03:36:19.863Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }