Search criteria
6 vulnerabilities found for appspider by rapid7
FKIE_CVE-2020-7358
Vulnerability from fkie_nvd - Published: 2020-09-18 15:15 - Updated: 2024-11-21 05:37
Severity ?
5.8 (Medium) - CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L
6.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H
6.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H
Summary
In AppSpider installer versions prior to 7.2.126, the AppSpider installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during an installation and any arbitrary code executable using the same file name.
References
| URL | Tags | ||
|---|---|---|---|
| cve@rapid7.com | https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126 | Release Notes, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126 | Release Notes, Vendor Advisory |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rapid7:appspider:*:*:*:*:-:-:*:*",
"matchCriteriaId": "F57BA91D-428B-4D02-9580-C80B0F1FB77C",
"versionEndExcluding": "7.2.126",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "In AppSpider installer versions prior to 7.2.126, the AppSpider installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during an installation and any arbitrary code executable using the same file name."
},
{
"lang": "es",
"value": "En el instalador AppSpider versiones anteriores a 7.2.126, el instalador AppSpider llama a un ejecutable que puede ser colocado en el directorio apropiado por un atacante con acceso a la m\u00e1quina local.\u0026#xa0;Esto impedir\u00eda que el instalador distinga entre un ejecutable v\u00e1lido llamado durante una instalaci\u00f3n y cualquier ejecutable de c\u00f3digo arbitrario usando el mismo nombre de archivo"
}
],
"id": "CVE-2020-7358",
"lastModified": "2024-11-21T05:37:06.747",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.4,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:L/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 3.4,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 0.3,
"impactScore": 5.5,
"source": "cve@rapid7.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.6,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-09-18T15:15:13.827",
"references": [
{
"source": "cve@rapid7.com",
"tags": [
"Release Notes",
"Vendor Advisory"
],
"url": "https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Release Notes",
"Vendor Advisory"
],
"url": "https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126"
}
],
"sourceIdentifier": "cve@rapid7.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-427"
}
],
"source": "cve@rapid7.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-427"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2019-5647
Vulnerability from fkie_nvd - Published: 2020-01-22 18:15 - Updated: 2024-11-21 04:45
Severity ?
4.4 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N
7.1 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
7.1 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
Summary
The Chrome Plugin for Rapid7 AppSpider can incorrectly keep browser sessions active after recording a macro, even after a restart of the Chrome browser. This behavior could make future session hijacking attempts easier, since the user could believe a session was closed when it was not. This issue affects Rapid7 AppSpider version 3.8.213 and prior versions, and is fixed in version 3.8.215.
References
| URL | Tags | ||
|---|---|---|---|
| cve@rapid7.com | https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215 | Release Notes, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215 | Release Notes, Vendor Advisory |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rapid7:appspider:*:*:*:*:enterprise:chrome:*:*",
"matchCriteriaId": "D611FD06-3056-45BC-8A41-CD3F29864E87",
"versionEndIncluding": "3.8.213",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The Chrome Plugin for Rapid7 AppSpider can incorrectly keep browser sessions active after recording a macro, even after a restart of the Chrome browser. This behavior could make future session hijacking attempts easier, since the user could believe a session was closed when it was not. This issue affects Rapid7 AppSpider version 3.8.213 and prior versions, and is fixed in version 3.8.215."
},
{
"lang": "es",
"value": "El Plugin de Chrome para Rapid7 AppSpider puede mantener activas las sesiones del navegador incorrectamente despu\u00e9s de grabar una macro, inclusive despu\u00e9s de reiniciar el navegador Chrome. Este comportamiento podr\u00eda facilitar los futuros intentos de secuestro de sesi\u00f3n, ya que el usuario podr\u00eda creer que una sesi\u00f3n fue cerrada cuando no era as\u00ed. Este problema afecta a Rapid7 AppSpider versi\u00f3n 3.8.213 y versiones anteriores, y es corregido en la versi\u00f3n 3.8.215."
}
],
"id": "CVE-2019-5647",
"lastModified": "2024-11-21T04:45:17.990",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 3.6,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 4.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 2.5,
"source": "cve@rapid7.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-01-22T18:15:12.077",
"references": [
{
"source": "cve@rapid7.com",
"tags": [
"Release Notes",
"Vendor Advisory"
],
"url": "https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Release Notes",
"Vendor Advisory"
],
"url": "https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215"
}
],
"sourceIdentifier": "cve@rapid7.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-613"
}
],
"source": "cve@rapid7.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-613"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2020-7358 (GCVE-0-2020-7358)
Vulnerability from cvelistv5 – Published: 2020-09-18 14:55 – Updated: 2024-08-04 09:25
VLAI?
Title
Code Injection in Rapid7 AppSpider Pro Installer
Summary
In AppSpider installer versions prior to 7.2.126, the AppSpider installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during an installation and any arbitrary code executable using the same file name.
Severity ?
5.8 (Medium)
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
Credits
This issue was discovered and reported by Mishra Dhiraj.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:25:48.976Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AppSpider ",
"vendor": "Rapid7",
"versions": [
{
"lessThan": "7.2.126",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "This issue was discovered and reported by Mishra Dhiraj. "
}
],
"descriptions": [
{
"lang": "en",
"value": "In AppSpider installer versions prior to 7.2.126, the AppSpider installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during an installation and any arbitrary code executable using the same file name."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-09-18T14:55:12",
"orgId": "9974b330-7714-4307-a722-5648477acda7",
"shortName": "rapid7"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Code Injection in Rapid7 AppSpider Pro Installer",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@rapid7.com",
"ID": "CVE-2020-7358",
"STATE": "PUBLIC",
"TITLE": "Code Injection in Rapid7 AppSpider Pro Installer"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "AppSpider ",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "7.2.126"
}
]
}
}
]
},
"vendor_name": "Rapid7"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "This issue was discovered and reported by Mishra Dhiraj. "
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In AppSpider installer versions prior to 7.2.126, the AppSpider installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during an installation and any arbitrary code executable using the same file name."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-427 Uncontrolled Search Path Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126",
"refsource": "MISC",
"url": "https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126"
}
]
},
"source": {
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
"assignerShortName": "rapid7",
"cveId": "CVE-2020-7358",
"datePublished": "2020-09-18T14:55:12",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:25:48.976Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-5647 (GCVE-0-2019-5647)
Vulnerability from cvelistv5 – Published: 2020-01-22 18:00 – Updated: 2024-09-17 00:51
VLAI?
Title
Rapid7 AppSpider Chrome Plugin Insufficient Session Expiration
Summary
The Chrome Plugin for Rapid7 AppSpider can incorrectly keep browser sessions active after recording a macro, even after a restart of the Chrome browser. This behavior could make future session hijacking attempts easier, since the user could believe a session was closed when it was not. This issue affects Rapid7 AppSpider version 3.8.213 and prior versions, and is fixed in version 3.8.215.
Severity ?
4.4 (Medium)
CWE
- CWE-613 - Insufficient Session Expiration
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:01:52.069Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AppSpider",
"vendor": "Rapid7",
"versions": [
{
"lessThanOrEqual": "3.8.213",
"status": "affected",
"version": "3.8.213",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-08-20T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The Chrome Plugin for Rapid7 AppSpider can incorrectly keep browser sessions active after recording a macro, even after a restart of the Chrome browser. This behavior could make future session hijacking attempts easier, since the user could believe a session was closed when it was not. This issue affects Rapid7 AppSpider version 3.8.213 and prior versions, and is fixed in version 3.8.215."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-613",
"description": "CWE-613 Insufficient Session Expiration",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-22T18:00:22",
"orgId": "9974b330-7714-4307-a722-5648477acda7",
"shortName": "rapid7"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215"
}
],
"source": {
"discovery": "USER"
},
"title": "Rapid7 AppSpider Chrome Plugin Insufficient Session Expiration",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@rapid7.com",
"DATE_PUBLIC": "2019-08-20T14:00:00.000Z",
"ID": "CVE-2019-5647",
"STATE": "PUBLIC",
"TITLE": "Rapid7 AppSpider Chrome Plugin Insufficient Session Expiration"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "AppSpider",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "3.8.213",
"version_value": "3.8.213"
}
]
}
}
]
},
"vendor_name": "Rapid7"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Chrome Plugin for Rapid7 AppSpider can incorrectly keep browser sessions active after recording a macro, even after a restart of the Chrome browser. This behavior could make future session hijacking attempts easier, since the user could believe a session was closed when it was not. This issue affects Rapid7 AppSpider version 3.8.213 and prior versions, and is fixed in version 3.8.215."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-613 Insufficient Session Expiration"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215",
"refsource": "CONFIRM",
"url": "https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215"
}
]
},
"source": {
"discovery": "USER"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
"assignerShortName": "rapid7",
"cveId": "CVE-2019-5647",
"datePublished": "2020-01-22T18:00:22.724972Z",
"dateReserved": "2019-01-07T00:00:00",
"dateUpdated": "2024-09-17T00:51:55.819Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7358 (GCVE-0-2020-7358)
Vulnerability from nvd – Published: 2020-09-18 14:55 – Updated: 2024-08-04 09:25
VLAI?
Title
Code Injection in Rapid7 AppSpider Pro Installer
Summary
In AppSpider installer versions prior to 7.2.126, the AppSpider installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during an installation and any arbitrary code executable using the same file name.
Severity ?
5.8 (Medium)
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
Credits
This issue was discovered and reported by Mishra Dhiraj.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:25:48.976Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AppSpider ",
"vendor": "Rapid7",
"versions": [
{
"lessThan": "7.2.126",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "This issue was discovered and reported by Mishra Dhiraj. "
}
],
"descriptions": [
{
"lang": "en",
"value": "In AppSpider installer versions prior to 7.2.126, the AppSpider installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during an installation and any arbitrary code executable using the same file name."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-09-18T14:55:12",
"orgId": "9974b330-7714-4307-a722-5648477acda7",
"shortName": "rapid7"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Code Injection in Rapid7 AppSpider Pro Installer",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@rapid7.com",
"ID": "CVE-2020-7358",
"STATE": "PUBLIC",
"TITLE": "Code Injection in Rapid7 AppSpider Pro Installer"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "AppSpider ",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "7.2.126"
}
]
}
}
]
},
"vendor_name": "Rapid7"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "This issue was discovered and reported by Mishra Dhiraj. "
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In AppSpider installer versions prior to 7.2.126, the AppSpider installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during an installation and any arbitrary code executable using the same file name."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-427 Uncontrolled Search Path Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126",
"refsource": "MISC",
"url": "https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126"
}
]
},
"source": {
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
"assignerShortName": "rapid7",
"cveId": "CVE-2020-7358",
"datePublished": "2020-09-18T14:55:12",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:25:48.976Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-5647 (GCVE-0-2019-5647)
Vulnerability from nvd – Published: 2020-01-22 18:00 – Updated: 2024-09-17 00:51
VLAI?
Title
Rapid7 AppSpider Chrome Plugin Insufficient Session Expiration
Summary
The Chrome Plugin for Rapid7 AppSpider can incorrectly keep browser sessions active after recording a macro, even after a restart of the Chrome browser. This behavior could make future session hijacking attempts easier, since the user could believe a session was closed when it was not. This issue affects Rapid7 AppSpider version 3.8.213 and prior versions, and is fixed in version 3.8.215.
Severity ?
4.4 (Medium)
CWE
- CWE-613 - Insufficient Session Expiration
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:01:52.069Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AppSpider",
"vendor": "Rapid7",
"versions": [
{
"lessThanOrEqual": "3.8.213",
"status": "affected",
"version": "3.8.213",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-08-20T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The Chrome Plugin for Rapid7 AppSpider can incorrectly keep browser sessions active after recording a macro, even after a restart of the Chrome browser. This behavior could make future session hijacking attempts easier, since the user could believe a session was closed when it was not. This issue affects Rapid7 AppSpider version 3.8.213 and prior versions, and is fixed in version 3.8.215."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-613",
"description": "CWE-613 Insufficient Session Expiration",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-22T18:00:22",
"orgId": "9974b330-7714-4307-a722-5648477acda7",
"shortName": "rapid7"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215"
}
],
"source": {
"discovery": "USER"
},
"title": "Rapid7 AppSpider Chrome Plugin Insufficient Session Expiration",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@rapid7.com",
"DATE_PUBLIC": "2019-08-20T14:00:00.000Z",
"ID": "CVE-2019-5647",
"STATE": "PUBLIC",
"TITLE": "Rapid7 AppSpider Chrome Plugin Insufficient Session Expiration"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "AppSpider",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "3.8.213",
"version_value": "3.8.213"
}
]
}
}
]
},
"vendor_name": "Rapid7"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Chrome Plugin for Rapid7 AppSpider can incorrectly keep browser sessions active after recording a macro, even after a restart of the Chrome browser. This behavior could make future session hijacking attempts easier, since the user could believe a session was closed when it was not. This issue affects Rapid7 AppSpider version 3.8.213 and prior versions, and is fixed in version 3.8.215."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-613 Insufficient Session Expiration"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215",
"refsource": "CONFIRM",
"url": "https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215"
}
]
},
"source": {
"discovery": "USER"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
"assignerShortName": "rapid7",
"cveId": "CVE-2019-5647",
"datePublished": "2020-01-22T18:00:22.724972Z",
"dateReserved": "2019-01-07T00:00:00",
"dateUpdated": "2024-09-17T00:51:55.819Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}