All the vulnerabilites related to intel - arc_a_graphics
Vulnerability from fkie_nvd
Published
2023-11-14 19:15
Modified
2024-11-21 07:56
Severity ?
6.7 (Medium) - CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
Summary
Unquoted search path or element in some Intel(R) Arc(TM) Control software before version 1.73.5335.2 may allow an authenticated user to potentially enable escalation of privilege via local access.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
intel | iris_xe_graphics | * | |
microsoft | windows | - | |
intel | arc_a_graphics | * | |
microsoft | windows | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:intel:iris_xe_graphics:*:*:*:*:*:*:*:*", "matchCriteriaId": "823ADDFE-919F-4097-8F7B-C9A35AFBEE51", "versionEndExcluding": "31.0.101.4255", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*", "matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:intel:arc_a_graphics:*:*:*:*:*:*:*:*", "matchCriteriaId": "7607C5DB-509D-4A20-83AA-391DEF78EDC8", "versionEndExcluding": "31.0.101.4255", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*", "matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Unquoted search path or element in some Intel(R) Arc(TM) Control software before version 1.73.5335.2 may allow an authenticated user to potentially enable escalation of privilege via local access." }, { "lang": "es", "value": "Elemento o ruta de b\u00fasqueda sin comillas en algunos controladores Intel(R) Arc(TM) \u0026amp; Iris(R) Xe Graphics - WHQL - Windows anteriores a la versi\u00f3n 31.0.101.4255 pueden permitir que un usuario autenticado habilite potencialmente la escalada de privilegios a trav\u00e9s del acceso local." } ], "id": "CVE-2023-29165", "lastModified": "2024-11-21T07:56:38.713", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.9, "source": "secure@intel.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.3, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-11-14T19:15:24.107", "references": [ { "source": "secure@intel.com", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01020.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01020.html" } ], "sourceIdentifier": "secure@intel.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-428" } ], "source": "secure@intel.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-428" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-11-14 19:15
Modified
2024-11-21 07:50
Severity ?
6.1 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Summary
Out-of-bounds write in some Intel(R) Arc(TM) Control software before version 1.73.5335.2 may allow an authenticated user to potentially enable denial of service via local access.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
intel | iris_xe_graphics | * | |
microsoft | windows | - | |
intel | arc_a_graphics | * | |
microsoft | windows | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:intel:iris_xe_graphics:*:*:*:*:*:*:*:*", "matchCriteriaId": "823ADDFE-919F-4097-8F7B-C9A35AFBEE51", "versionEndExcluding": "31.0.101.4255", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*", "matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:intel:arc_a_graphics:*:*:*:*:*:*:*:*", "matchCriteriaId": "7607C5DB-509D-4A20-83AA-391DEF78EDC8", "versionEndExcluding": "31.0.101.4255", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*", "matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Out-of-bounds write in some Intel(R) Arc(TM) Control software before version 1.73.5335.2 may allow an authenticated user to potentially enable denial of service via local access." }, { "lang": "es", "value": "La escritura fuera de los l\u00edmites en algunos controladores Intel(R) Arc(TM) e Iris(R) Xe Graphics - WHQL - Windows anteriores a la versi\u00f3n 31.0.101.4255 puede permitir que un usuario autenticado habilite potencialmente la denegaci\u00f3n de servicio a trav\u00e9s del acceso local." } ], "id": "CVE-2023-25952", "lastModified": "2024-11-21T07:50:30.477", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 4.2, "source": "secure@intel.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-11-14T19:15:20.123", "references": [ { "source": "secure@intel.com", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01020.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01020.html" } ], "sourceIdentifier": "secure@intel.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "secure@intel.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2024-08-14 14:15
Modified
2024-09-06 18:38
Severity ?
5.0 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:N/A:H
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Summary
Improper access control in some Intel(R) Arc(TM) & Iris(R) Xe Graphics software before version 31.0.101.4824 may allow an authenticated user to potentially enable denial of service via local access.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
intel | arc_a_graphics | * | |
intel | iris_xe_graphics | * |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:intel:arc_a_graphics:*:*:*:*:*:*:*:*", "matchCriteriaId": "CC7338AA-98F6-4184-827F-F99585BD954C", "versionEndExcluding": "31.0.101.4824", "vulnerable": true }, { "criteria": "cpe:2.3:a:intel:iris_xe_graphics:*:*:*:*:*:*:*:*", "matchCriteriaId": "0DEA3D9E-9F46-46F6-990E-411E0D601371", "versionEndExcluding": "31.0.101.4824", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Improper access control in some Intel(R) Arc(TM) \u0026 Iris(R) Xe Graphics software before version 31.0.101.4824 may allow an authenticated user to potentially enable denial of service via local access." }, { "lang": "es", "value": " Un control de acceso inadecuado en algunos software Intel(R) Arc(TM) e Iris(R) Xe Graphics anteriores a la versi\u00f3n 31.0.101.4824 puede permitir que un usuario autenticado potencialmente habilite la denegaci\u00f3n de servicio a trav\u00e9s del acceso local." } ], "id": "CVE-2024-28050", "lastModified": "2024-09-06T18:38:11.353", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 5.0, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 1.3, "impactScore": 3.6, "source": "secure@intel.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ], "cvssMetricV40": [ { "cvssData": { "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "LOCAL", "automatable": "NOT_DEFINED", "availabilityRequirements": "NOT_DEFINED", "baseScore": 5.1, "baseSeverity": "MEDIUM", "confidentialityRequirements": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirements": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubsequentSystemAvailability": "NOT_DEFINED", "modifiedSubsequentSystemConfidentiality": "NOT_DEFINED", "modifiedSubsequentSystemIntegrity": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnerableSystemAvailability": "NOT_DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT_DEFINED", "modifiedVulnerableSystemIntegrity": "NOT_DEFINED", "privilegesRequired": "LOW", "providerUrgency": "NOT_DEFINED", "recovery": "NOT_DEFINED", "safety": "NOT_DEFINED", "subsequentSystemAvailability": "NONE", "subsequentSystemConfidentiality": "NONE", "subsequentSystemIntegrity": "NONE", "userInteraction": "PASSIVE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnerabilityResponseEffort": "NOT_DEFINED", "vulnerableSystemAvailability": "HIGH", "vulnerableSystemConfidentiality": "NONE", "vulnerableSystemIntegrity": "NONE" }, "source": "secure@intel.com", "type": "Secondary" } ] }, "published": "2024-08-14T14:15:25.050", "references": [ { "source": "secure@intel.com", "tags": [ "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01130.html" } ], "sourceIdentifier": "secure@intel.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-284" } ], "source": "secure@intel.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-11-14 19:15
Modified
2024-11-21 07:54
Severity ?
5.7 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
Out-of-bounds write in some Intel(R) Arc(TM) & Iris(R) Xe Graphics - WHQL - Windows drivers before version 31.0.101.4255 may allow authenticated user to potentially enable escalation of privilege via local access.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
intel | iris_xe_graphics | * | |
microsoft | windows | - | |
intel | arc_a_graphics | * | |
microsoft | windows | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:intel:iris_xe_graphics:*:*:*:*:*:*:*:*", "matchCriteriaId": "823ADDFE-919F-4097-8F7B-C9A35AFBEE51", "versionEndExcluding": "31.0.101.4255", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*", "matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:intel:arc_a_graphics:*:*:*:*:*:*:*:*", "matchCriteriaId": "7607C5DB-509D-4A20-83AA-391DEF78EDC8", "versionEndExcluding": "31.0.101.4255", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*", "matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Out-of-bounds write in some Intel(R) Arc(TM) \u0026 Iris(R) Xe Graphics - WHQL - Windows drivers before version 31.0.101.4255 may allow authenticated user to potentially enable escalation of privilege via local access." }, { "lang": "es", "value": "La escritura fuera de los l\u00edmites en algunos controladores Intel(R) Arc(TM) \u0026amp; Iris(R) Xe Graphics - WHQL - Windows anteriores a la versi\u00f3n 31.0.101.4255 puede permitir que el usuario autenticado habilite potencialmente la escalada de privilegios a trav\u00e9s del acceso local." } ], "id": "CVE-2023-28401", "lastModified": "2024-11-21T07:54:59.807", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 5.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 1.5, "impactScore": 3.7, "source": "secure@intel.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-11-14T19:15:22.680", "references": [ { "source": "secure@intel.com", "tags": [ "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00864.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00864.html" } ], "sourceIdentifier": "secure@intel.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "secure@intel.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-787" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-11-14 19:15
Modified
2024-11-21 07:55
Severity ?
3.8 (Low) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Summary
Out-of-bounds read in the Intel(R) Arc(TM) & Iris(R) Xe Graphics - WHQL - Windows drivers before version 31.0.101.4255 may allow an authenticated user to potentially enable information disclosure via local access.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
intel | iris_xe_graphics | * | |
microsoft | windows | - | |
intel | arc_a_graphics | * | |
microsoft | windows | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:intel:iris_xe_graphics:*:*:*:*:*:*:*:*", "matchCriteriaId": "823ADDFE-919F-4097-8F7B-C9A35AFBEE51", "versionEndExcluding": "31.0.101.4255", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*", "matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:intel:arc_a_graphics:*:*:*:*:*:*:*:*", "matchCriteriaId": "7607C5DB-509D-4A20-83AA-391DEF78EDC8", "versionEndExcluding": "31.0.101.4255", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*", "matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Out-of-bounds read in the Intel(R) Arc(TM) \u0026 Iris(R) Xe Graphics - WHQL - Windows drivers before version 31.0.101.4255 may allow an authenticated user to potentially enable information disclosure via local access." }, { "lang": "es", "value": "Los l\u00edmites le\u00eddos en los controladores Intel(R) Arc(TM) \u0026amp; Iris(R) Xe Graphics - WHQL - Windows anteriores a la versi\u00f3n 31.0.101.4255 pueden permitir que un usuario autenticado potencialmente habilite la divulgaci\u00f3n de informaci\u00f3n a trav\u00e9s del acceso local." } ], "id": "CVE-2023-28404", "lastModified": "2024-11-21T07:55:00.030", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 3.8, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.0, "impactScore": 1.4, "source": "secure@intel.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-11-14T19:15:22.853", "references": [ { "source": "secure@intel.com", "tags": [ "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00864.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00864.html" } ], "sourceIdentifier": "secure@intel.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "secure@intel.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-125" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-11-14 19:15
Modified
2024-11-21 07:52
Severity ?
6.7 (Medium) - CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
Incorrect default permissions in some Intel(R) Arc(TM) Control software before version 1.73.5335.2 may allow an authenticated user to potentially enable escalation of privilege via local access.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
intel | iris_xe_graphics | * | |
microsoft | windows | - | |
intel | arc_a_graphics | * | |
microsoft | windows | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:intel:iris_xe_graphics:*:*:*:*:*:*:*:*", "matchCriteriaId": "823ADDFE-919F-4097-8F7B-C9A35AFBEE51", "versionEndExcluding": "31.0.101.4255", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*", "matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:intel:arc_a_graphics:*:*:*:*:*:*:*:*", "matchCriteriaId": "7607C5DB-509D-4A20-83AA-391DEF78EDC8", "versionEndExcluding": "31.0.101.4255", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*", "matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "Incorrect default permissions in some Intel(R) Arc(TM) Control software before version 1.73.5335.2 may allow an authenticated user to potentially enable escalation of privilege via local access." }, { "lang": "es", "value": "Los permisos predeterminados incorrectos en algunos controladores Intel(R) Arc(TM) e Iris(R) Xe Graphics - WHQL - Windows anteriores a la versi\u00f3n 31.0.101.4255 pueden permitir que un usuario autenticado habilite potencialmente la escalada de privilegios a trav\u00e9s del acceso local." } ], "id": "CVE-2023-27305", "lastModified": "2024-11-21T07:52:36.803", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.8, "impactScore": 5.9, "source": "secure@intel.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-11-14T19:15:20.473", "references": [ { "source": "secure@intel.com", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01020.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01020.html" } ], "sourceIdentifier": "secure@intel.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-276" } ], "source": "secure@intel.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-276" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Vulnerability from fkie_nvd
Published
2023-11-14 19:15
Modified
2024-11-21 07:49
Severity ?
5.6 (Medium) - CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:N/I:N/A:H
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
5.5 (Medium) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Summary
NULL pointer dereference in some Intel(R) Arc(TM) & Iris(R) Xe Graphics - WHQL - Windows Drviers before version 31.0.101.4255 may allow authenticated user to potentially enable denial of service via local access.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
intel | iris_xe_graphics | * | |
microsoft | windows | - | |
intel | arc_a_graphics | * | |
microsoft | windows | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:intel:iris_xe_graphics:*:*:*:*:*:*:*:*", "matchCriteriaId": "823ADDFE-919F-4097-8F7B-C9A35AFBEE51", "versionEndExcluding": "31.0.101.4255", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*", "matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:intel:arc_a_graphics:*:*:*:*:*:*:*:*", "matchCriteriaId": "7607C5DB-509D-4A20-83AA-391DEF78EDC8", "versionEndExcluding": "31.0.101.4255", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*", "matchCriteriaId": "A2572D17-1DE6-457B-99CC-64AFD54487EA", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "NULL pointer dereference in some Intel(R) Arc(TM) \u0026 Iris(R) Xe Graphics - WHQL - Windows Drviers before version 31.0.101.4255 may allow authenticated user to potentially enable denial of service via local access." }, { "lang": "es", "value": "La desreferencia del puntero NULL en algunos Intel(R) Arc(TM) \u0026amp; Iris(R) Xe Graphics - WHQL - Windows Drviers anteriores a la versi\u00f3n 31.0.101.4255 puede permitir que el usuario autenticado habilite potencialmente la denegaci\u00f3n de servicio a trav\u00e9s del acceso local." } ], "id": "CVE-2023-25071", "lastModified": "2024-11-21T07:49:02.867", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 5.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 1.1, "impactScore": 4.0, "source": "secure@intel.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-11-14T19:15:18.953", "references": [ { "source": "secure@intel.com", "tags": [ "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00864.html" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00864.html" } ], "sourceIdentifier": "secure@intel.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-395" } ], "source": "secure@intel.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-476" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
cve-2024-28050
Vulnerability from cvelistv5
Published
2024-08-14 13:45
Modified
2024-08-16 15:48
Severity ?
EPSS score ?
Summary
Improper access control in some Intel(R) Arc(TM) & Iris(R) Xe Graphics software before version 31.0.101.4824 may allow an authenticated user to potentially enable denial of service via local access.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | Intel(R) Arc(TM) & Iris(R) Xe Graphics software |
Version: before version 31.0.101.4824 |
|
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-28050", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-16T15:47:58.957476Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-16T15:48:07.136Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Intel(R) Arc(TM) \u0026 Iris(R) Xe Graphics software", "vendor": "n/a", "versions": [ { "status": "affected", "version": "before version 31.0.101.4824" } ] } ], "descriptions": [ { "lang": "en", "value": "Improper access control in some Intel(R) Arc(TM) \u0026 Iris(R) Xe Graphics software before version 31.0.101.4824 may allow an authenticated user to potentially enable denial of service via local access." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 5, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:N/A:H", "version": "3.1" }, "cvssV4_0": { "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "LOCAL", "baseScore": 5.1, "baseSeverity": "MEDIUM", "privilegesRequired": "LOW", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "PASSIVE", "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "NONE", "vulnIntegrityImpact": "NONE" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "denial of service", "lang": "en" }, { "cweId": "CWE-284", "description": "Improper access control", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-08-14T13:45:16.572Z", "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "shortName": "intel" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01130.html", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01130.html" } ] } }, "cveMetadata": { "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "assignerShortName": "intel", "cveId": "CVE-2024-28050", "datePublished": "2024-08-14T13:45:16.572Z", "dateReserved": "2024-03-27T03:00:07.317Z", "dateUpdated": "2024-08-16T15:48:07.136Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-25952
Vulnerability from cvelistv5
Published
2023-11-14 19:04
Modified
2024-08-02 11:39
Severity ?
EPSS score ?
Summary
Out-of-bounds write in some Intel(R) Arc(TM) Control software before version 1.73.5335.2 may allow an authenticated user to potentially enable denial of service via local access.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | Intel(R) Arc(TM) Control software |
Version: before version 1.73.5335.2 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:39:06.145Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01020.html", "tags": [ "x_transferred" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01020.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Intel(R) Arc(TM) Control software", "vendor": "n/a", "versions": [ { "status": "affected", "version": "before version 1.73.5335.2" } ] } ], "descriptions": [ { "lang": "en", "value": "Out-of-bounds write in some Intel(R) Arc(TM) Control software before version 1.73.5335.2 may allow an authenticated user to potentially enable denial of service via local access." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.1, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "denial of service", "lang": "en" }, { "cweId": "CWE-787", "description": "Out-of-bounds write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-16T20:47:33.466Z", "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "shortName": "intel" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01020.html", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01020.html" } ] } }, "cveMetadata": { "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "assignerShortName": "intel", "cveId": "CVE-2023-25952", "datePublished": "2023-11-14T19:04:22.210Z", "dateReserved": "2023-03-08T04:00:03.712Z", "dateUpdated": "2024-08-02T11:39:06.145Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-28404
Vulnerability from cvelistv5
Published
2023-11-14 19:04
Modified
2024-08-02 12:38
Severity ?
EPSS score ?
Summary
Out-of-bounds read in the Intel(R) Arc(TM) & Iris(R) Xe Graphics - WHQL - Windows drivers before version 31.0.101.4255 may allow an authenticated user to potentially enable information disclosure via local access.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | Intel(R) Arc(TM) & Iris(R) Xe Graphics - WHQL - Windows drivers |
Version: before version 31.0.101.4255 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T12:38:25.188Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00864.html", "tags": [ "x_transferred" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00864.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Intel(R) Arc(TM) \u0026 Iris(R) Xe Graphics - WHQL - Windows drivers", "vendor": "n/a", "versions": [ { "status": "affected", "version": "before version 31.0.101.4255" } ] } ], "descriptions": [ { "lang": "en", "value": "Out-of-bounds read in the Intel(R) Arc(TM) \u0026 Iris(R) Xe Graphics - WHQL - Windows drivers before version 31.0.101.4255 may allow an authenticated user to potentially enable information disclosure via local access." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 3.8, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "information disclosure", "lang": "en" }, { "cweId": "CWE-125", "description": "Out-of-bounds read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-14T19:04:24.382Z", "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "shortName": "intel" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00864.html", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00864.html" } ] } }, "cveMetadata": { "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "assignerShortName": "intel", "cveId": "CVE-2023-28404", "datePublished": "2023-11-14T19:04:24.382Z", "dateReserved": "2023-03-22T03:00:05.368Z", "dateUpdated": "2024-08-02T12:38:25.188Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-29165
Vulnerability from cvelistv5
Published
2023-11-14 19:04
Modified
2024-08-02 14:00
Severity ?
EPSS score ?
Summary
Unquoted search path or element in some Intel(R) Arc(TM) Control software before version 1.73.5335.2 may allow an authenticated user to potentially enable escalation of privilege via local access.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | Intel(R) Arc(TM) Control software |
Version: before version 1.73.5335.2 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:00:15.830Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01020.html", "tags": [ "x_transferred" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01020.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Intel(R) Arc(TM) Control software", "vendor": "n/a", "versions": [ { "status": "affected", "version": "before version 1.73.5335.2" } ] } ], "descriptions": [ { "lang": "en", "value": "Unquoted search path or element in some Intel(R) Arc(TM) Control software before version 1.73.5335.2 may allow an authenticated user to potentially enable escalation of privilege via local access." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "escalation of privilege", "lang": "en" }, { "cweId": "CWE-428", "description": "Unquoted search path or element", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-16T20:47:31.843Z", "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "shortName": "intel" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01020.html", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01020.html" } ] } }, "cveMetadata": { "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "assignerShortName": "intel", "cveId": "CVE-2023-29165", "datePublished": "2023-11-14T19:04:20.572Z", "dateReserved": "2023-04-07T03:00:04.456Z", "dateUpdated": "2024-08-02T14:00:15.830Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-25071
Vulnerability from cvelistv5
Published
2023-11-14 19:04
Modified
2024-08-30 17:57
Severity ?
EPSS score ?
Summary
NULL pointer dereference in some Intel(R) Arc(TM) & Iris(R) Xe Graphics - WHQL - Windows Drviers before version 31.0.101.4255 may allow authenticated user to potentially enable denial of service via local access.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | Intel(R) Arc(TM) & Iris(R) Xe Graphics - WHQL - Windows Drviers |
Version: before version 31.0.101.4255 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T11:11:43.484Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00864.html", "tags": [ "x_transferred" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00864.html" } ], "title": "CVE Program Container" }, { "metrics": [ { "other": { "content": { "id": "CVE-2023-25071", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-08-30T17:56:59.836251Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-30T17:57:11.480Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Intel(R) Arc(TM) \u0026 Iris(R) Xe Graphics - WHQL - Windows Drviers", "vendor": "n/a", "versions": [ { "status": "affected", "version": "before version 31.0.101.4255" } ] } ], "descriptions": [ { "lang": "en", "value": "NULL pointer dereference in some Intel(R) Arc(TM) \u0026 Iris(R) Xe Graphics - WHQL - Windows Drviers before version 31.0.101.4255 may allow authenticated user to potentially enable denial of service via local access." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 5.6, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:N/I:N/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "denial of service", "lang": "en" }, { "cweId": "CWE-395", "description": "NULL pointer dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-14T19:04:23.342Z", "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "shortName": "intel" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00864.html", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00864.html" } ] } }, "cveMetadata": { "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "assignerShortName": "intel", "cveId": "CVE-2023-25071", "datePublished": "2023-11-14T19:04:23.342Z", "dateReserved": "2023-03-22T03:00:05.340Z", "dateUpdated": "2024-08-30T17:57:11.480Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-27305
Vulnerability from cvelistv5
Published
2023-11-14 19:04
Modified
2024-08-02 12:09
Severity ?
EPSS score ?
Summary
Incorrect default permissions in some Intel(R) Arc(TM) Control software before version 1.73.5335.2 may allow an authenticated user to potentially enable escalation of privilege via local access.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | Intel(R) Arc(TM) Control software |
Version: before version 1.73.5335.2 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T12:09:43.445Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01020.html", "tags": [ "x_transferred" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01020.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Intel(R) Arc(TM) Control software", "vendor": "n/a", "versions": [ { "status": "affected", "version": "before version 1.73.5335.2" } ] } ], "descriptions": [ { "lang": "en", "value": "Incorrect default permissions in some Intel(R) Arc(TM) Control software before version 1.73.5335.2 may allow an authenticated user to potentially enable escalation of privilege via local access." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 6.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "escalation of privilege", "lang": "en" }, { "cweId": "CWE-276", "description": "Incorrect default permissions", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-16T20:47:32.645Z", "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "shortName": "intel" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01020.html", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01020.html" } ] } }, "cveMetadata": { "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "assignerShortName": "intel", "cveId": "CVE-2023-27305", "datePublished": "2023-11-14T19:04:21.686Z", "dateReserved": "2023-03-08T04:00:03.633Z", "dateUpdated": "2024-08-02T12:09:43.445Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2023-28401
Vulnerability from cvelistv5
Published
2023-11-14 19:04
Modified
2024-08-02 12:38
Severity ?
EPSS score ?
Summary
Out-of-bounds write in some Intel(R) Arc(TM) & Iris(R) Xe Graphics - WHQL - Windows drivers before version 31.0.101.4255 may allow authenticated user to potentially enable escalation of privilege via local access.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | Intel(R) Arc(TM) & Iris(R) Xe Graphics - WHQL - Windows drivers |
Version: before version 31.0.101.4255 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T12:38:25.111Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00864.html", "tags": [ "x_transferred" ], "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00864.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Intel(R) Arc(TM) \u0026 Iris(R) Xe Graphics - WHQL - Windows drivers", "vendor": "n/a", "versions": [ { "status": "affected", "version": "before version 31.0.101.4255" } ] } ], "descriptions": [ { "lang": "en", "value": "Out-of-bounds write in some Intel(R) Arc(TM) \u0026 Iris(R) Xe Graphics - WHQL - Windows drivers before version 31.0.101.4255 may allow authenticated user to potentially enable escalation of privilege via local access." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "LOW", "baseScore": 5.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "description": "escalation of privilege", "lang": "en" }, { "cweId": "CWE-787", "description": "Out-of-bounds write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-14T19:04:23.883Z", "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "shortName": "intel" }, "references": [ { "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00864.html", "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00864.html" } ] } }, "cveMetadata": { "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce", "assignerShortName": "intel", "cveId": "CVE-2023-28401", "datePublished": "2023-11-14T19:04:23.883Z", "dateReserved": "2023-03-22T03:00:05.326Z", "dateUpdated": "2024-08-02T12:38:25.111Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }