Search criteria

168 vulnerabilities found for ax1803_firmware by tenda

FKIE_CVE-2025-63457

Vulnerability from fkie_nvd - Published: 2025-11-10 17:15 - Updated: 2025-11-18 17:16
Summary
Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the wanMTU parameter in the sub_4F55C function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
Impacted products
Vendor Product Version
tenda ax1803_firmware 1.0.0.1
tenda ax1803 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ax1803_firmware:1.0.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "B81C53EE-14CD-426B-ADF3-6D9B4D69DC84",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "413B93A8-6188-4D89-8141-C5B73F4AA071",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the wanMTU parameter in the sub_4F55C function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
    },
    {
      "lang": "es",
      "value": "Se descubri\u00f3 que Tenda AX-1803 v1.0.0.1 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro wanMTU en la funci\u00f3n sub_4F55C. Esta vulnerabilidad permite a los atacantes causar una denegaci\u00f3n de servicio (DoS) a trav\u00e9s de una solicitud manipulada."
    }
  ],
  "id": "CVE-2025-63457",
  "lastModified": "2025-11-18T17:16:09.427",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-11-10T17:15:35.100",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/1/1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2025-63456

Vulnerability from fkie_nvd - Published: 2025-11-10 17:15 - Updated: 2025-11-18 17:16
Summary
Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the time parameter in the SetSysTimeCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
Impacted products
Vendor Product Version
tenda ax1803_firmware 1.0.0.1
tenda ax1803 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ax1803_firmware:1.0.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "B81C53EE-14CD-426B-ADF3-6D9B4D69DC84",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "413B93A8-6188-4D89-8141-C5B73F4AA071",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the time parameter in the SetSysTimeCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
    },
    {
      "lang": "es",
      "value": "Tenda AX-1803 v1.0.0.1 fue descubierto que conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro \u0027time\u0027 en la funci\u00f3n SetSysTimeCfg. Esta vulnerabilidad permite a los atacantes causar una denegaci\u00f3n de servicio (DoS) a trav\u00e9s de una solicitud manipulada."
    }
  ],
  "id": "CVE-2025-63456",
  "lastModified": "2025-11-18T17:16:09.087",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-11-10T17:15:34.957",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/3/1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2025-63458

Vulnerability from fkie_nvd - Published: 2025-10-31 19:15 - Updated: 2025-11-05 17:28
Summary
Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the timeZone parameter in the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
Impacted products
Vendor Product Version
tenda ax1803_firmware 1.0.0.1
tenda ax1803 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ax1803_firmware:1.0.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "B81C53EE-14CD-426B-ADF3-6D9B4D69DC84",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "413B93A8-6188-4D89-8141-C5B73F4AA071",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the timeZone parameter in the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
    }
  ],
  "id": "CVE-2025-63458",
  "lastModified": "2025-11-05T17:28:58.980",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-10-31T19:15:51.163",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/2/1.md"
    },
    {
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/2/1.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2025-7597

Vulnerability from fkie_nvd - Published: 2025-07-14 11:15 - Updated: 2025-07-15 18:27
Summary
A vulnerability classified as critical has been found in Tenda AX1803 1.0.0.1. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Impacted products
Vendor Product Version
tenda ax1803_firmware 1.0.0.1
tenda ax1803 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ax1803_firmware:1.0.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "B81C53EE-14CD-426B-ADF3-6D9B4D69DC84",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "413B93A8-6188-4D89-8141-C5B73F4AA071",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability classified as critical has been found in Tenda AX1803 1.0.0.1. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
    },
    {
      "lang": "es",
      "value": "Se ha detectado una vulnerabilidad cr\u00edtica en Tenda AX1803 1.0.0.1. La funci\u00f3n formSetMacFilterCfg del archivo /goform/setMacFilterCfg est\u00e1 afectada. La manipulaci\u00f3n del argumento deviceList provoca un desbordamiento del b\u00fafer en la pila. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado."
    }
  ],
  "id": "CVE-2025-7597",
  "lastModified": "2025-07-15T18:27:31.957",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "cna@vuldb.com",
        "type": "Secondary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "cna@vuldb.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.4,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "PROOF_OF_CONCEPT",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "cna@vuldb.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-07-14T11:15:23.410",
  "references": [
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetMacFilterCfg.md"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetMacFilterCfg.md#poc"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?ctiid.316296"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?id.316296"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?submit.615268"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Product"
      ],
      "url": "https://www.tenda.com.cn/"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        },
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "cna@vuldb.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2025-7598

Vulnerability from fkie_nvd - Published: 2025-07-14 11:15 - Updated: 2025-07-16 14:33
Summary
A vulnerability classified as critical was found in Tenda AX1803 1.0.0.1. Affected by this vulnerability is the function formSetWifiMacFilterCfg of the file /goform/setWifiFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Impacted products
Vendor Product Version
tenda ax1803_firmware 1.0.0.1
tenda ax1803 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ax1803_firmware:1.0.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "B81C53EE-14CD-426B-ADF3-6D9B4D69DC84",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "413B93A8-6188-4D89-8141-C5B73F4AA071",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability classified as critical was found in Tenda AX1803 1.0.0.1. Affected by this vulnerability is the function formSetWifiMacFilterCfg of the file /goform/setWifiFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
    },
    {
      "lang": "es",
      "value": "Se encontr\u00f3 una vulnerabilidad clasificada como cr\u00edtica en Tenda AX1803 1.0.0.1. Esta vulnerabilidad afecta a la funci\u00f3n formSetWifiMacFilterCfg del archivo /goform/setWifiFilterCfg. La manipulaci\u00f3n del argumento deviceList provoca un desbordamiento del b\u00fafer basado en la pila. El ataque puede ejecutarse en remoto. Se ha hecho p\u00fablico el exploit y puede que sea utilizado."
    }
  ],
  "id": "CVE-2025-7598",
  "lastModified": "2025-07-16T14:33:52.283",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "cna@vuldb.com",
        "type": "Secondary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "cna@vuldb.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.4,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "PROOF_OF_CONCEPT",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "cna@vuldb.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-07-14T11:15:23.607",
  "references": [
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetWifiMacFilterCfg.md"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetWifiMacFilterCfg.md#poc"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?ctiid.316297"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?id.316297"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?submit.615269"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Product"
      ],
      "url": "https://www.tenda.com.cn/"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        },
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "cna@vuldb.com",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2024-4236

Vulnerability from fkie_nvd - Published: 2024-04-26 18:15 - Updated: 2025-03-06 16:30
Summary
A vulnerability, which was classified as critical, has been found in Tenda AX1803 1.0.0.1. This issue affects the function formSetSysToolDDNS of the file /goform/SetDDNSCfg. The manipulation of the argument serverName/ddnsUser/ddnsPwd/ddnsDomain leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Impacted products
Vendor Product Version
tenda ax1803_firmware 1.0.0.1
tenda ax1803 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ax1803_firmware:1.0.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "B81C53EE-14CD-426B-ADF3-6D9B4D69DC84",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "413B93A8-6188-4D89-8141-C5B73F4AA071",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability, which was classified as critical, has been found in Tenda AX1803 1.0.0.1. This issue affects the function formSetSysToolDDNS of the file /goform/SetDDNSCfg. The manipulation of the argument serverName/ddnsUser/ddnsPwd/ddnsDomain leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad fue encontrada en Tenda AX1803 1.0.0.1 y clasificada como cr\u00edtica. Este problema afecta a la funci\u00f3n formSetSysToolDDNS del archivo /goform/SetDDNSCfg. La manipulaci\u00f3n del argumento serverName/ddnsUser/ddnsPwd/ddnsDomain provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque puede iniciarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse. El identificador asociado de esta vulnerabilidad es VDB-262127. NOTA: Se contact\u00f3 primeramente con el proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
    }
  ],
  "id": "CVE-2024-4236",
  "lastModified": "2025-03-06T16:30:09.780",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "cna@vuldb.com",
        "type": "Secondary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-04-26T18:15:46.803",
  "references": [
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Broken Link"
      ],
      "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AX/AX1803/formSetSysToolDDNS.md"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?ctiid.262127"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?id.262127"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?submit.319230"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Broken Link"
      ],
      "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AX/AX1803/formSetSysToolDDNS.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Permissions Required",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?ctiid.262127"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Permissions Required",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?id.262127"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?submit.319230"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "cna@vuldb.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2024-30620

Vulnerability from fkie_nvd - Published: 2024-04-02 14:15 - Updated: 2025-03-25 15:15

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ax1803_firmware:1.0.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "B81C53EE-14CD-426B-ADF3-6D9B4D69DC84",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "413B93A8-6188-4D89-8141-C5B73F4AA071",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the serviceName parameter in the function fromAdvSetMacMtuWan."
    },
    {
      "lang": "es",
      "value": "Tenda AX1803 v1.0.0.1 contiene un desbordamiento de pila a trav\u00e9s del par\u00e1metro serviceName en la funci\u00f3n fromAdvSetMacMtuWan."
    }
  ],
  "id": "CVE-2024-30620",
  "lastModified": "2025-03-25T15:15:20.967",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-04-02T14:15:08.150",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serviceName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serviceName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2024-30621

Vulnerability from fkie_nvd - Published: 2024-04-02 14:15 - Updated: 2024-11-21 09:12

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ax1803_firmware:1.0.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "B81C53EE-14CD-426B-ADF3-6D9B4D69DC84",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "413B93A8-6188-4D89-8141-C5B73F4AA071",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the serverName parameter in the function fromAdvSetMacMtuWan."
    },
    {
      "lang": "es",
      "value": "Tenda AX1803 v1.0.0.1 contiene un desbordamiento de pila a trav\u00e9s del par\u00e1metro serverName en la funci\u00f3n fromAdvSetMacMtuWan."
    }
  ],
  "id": "CVE-2024-30621",
  "lastModified": "2024-11-21T09:12:19.600",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "ADJACENT_NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 3.6,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-04-02T14:15:08.213",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serverName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serverName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-121"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2023-51968

Vulnerability from fkie_nvd - Published: 2024-01-10 16:15 - Updated: 2025-06-16 19:15
Summary
Tenda AX1803 v1.0.0.1 contains a stack overflow via the adv.iptv.stballvlans parameter in the function getIptvInfo.
Impacted products
Vendor Product Version
tenda ax1803_firmware 1.0.0.1
tenda ax1803 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ax1803_firmware:1.0.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "B81C53EE-14CD-426B-ADF3-6D9B4D69DC84",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "413B93A8-6188-4D89-8141-C5B73F4AA071",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the adv.iptv.stballvlans parameter in the function getIptvInfo."
    },
    {
      "lang": "es",
      "value": "Tenda AX1803 v1.0.0.1 contiene un desbordamiento de pila a trav\u00e9s del par\u00e1metro adv.iptv.stballvlans en la funci\u00f3n getIptvInfo."
    }
  ],
  "id": "CVE-2023-51968",
  "lastModified": "2025-06-16T19:15:29.113",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-01-10T16:15:49.887",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-getIptvInfo-f5918cc2828c49e78554f456bf7d4b36"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-getIptvInfo-f5918cc2828c49e78554f456bf7d4b36"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2023-51969

Vulnerability from fkie_nvd - Published: 2024-01-10 16:15 - Updated: 2025-06-20 16:15
Summary
Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.city.vlan parameter in the function getIptvInfo.
Impacted products
Vendor Product Version
tenda ax1803_firmware 1.0.0.1
tenda ax1803 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ax1803_firmware:1.0.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "B81C53EE-14CD-426B-ADF3-6D9B4D69DC84",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "413B93A8-6188-4D89-8141-C5B73F4AA071",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.city.vlan parameter in the function getIptvInfo."
    },
    {
      "lang": "es",
      "value": "Tenda AX1803 v1.0.0.1 contiene un desbordamiento de pila a trav\u00e9s del par\u00e1metro iptv.city.vlan en la funci\u00f3n getIptvInfo."
    }
  ],
  "id": "CVE-2023-51969",
  "lastModified": "2025-06-20T16:15:27.427",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-01-10T16:15:49.930",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-getIptvInfo-f5918cc2828c49e78554f456bf7d4b36"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-getIptvInfo-f5918cc2828c49e78554f456bf7d4b36"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2023-51970

Vulnerability from fkie_nvd - Published: 2024-01-10 16:15 - Updated: 2025-06-20 16:15
Summary
Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function formSetIptv.
Impacted products
Vendor Product Version
tenda ax1803_firmware 1.0.0.1
tenda ax1803 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ax1803_firmware:1.0.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "B81C53EE-14CD-426B-ADF3-6D9B4D69DC84",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "413B93A8-6188-4D89-8141-C5B73F4AA071",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function formSetIptv."
    },
    {
      "lang": "es",
      "value": "Tenda AX1803 v1.0.0.1 contiene un desbordamiento de pila a trav\u00e9s del par\u00e1metro iptv.stb.mode en la funci\u00f3n formSetIptv."
    }
  ],
  "id": "CVE-2023-51970",
  "lastModified": "2025-06-20T16:15:27.613",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-01-10T16:15:49.977",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-getIptvInfo-f5918cc2828c49e78554f456bf7d4b36"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-getIptvInfo-f5918cc2828c49e78554f456bf7d4b36"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2023-51962

Vulnerability from fkie_nvd - Published: 2024-01-10 16:15 - Updated: 2025-04-17 16:15
Summary
Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function setIptvInfo.
Impacted products
Vendor Product Version
tenda ax1803_firmware 1.0.0.1
tenda ax1803 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ax1803_firmware:1.0.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "B81C53EE-14CD-426B-ADF3-6D9B4D69DC84",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "413B93A8-6188-4D89-8141-C5B73F4AA071",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function setIptvInfo."
    },
    {
      "lang": "es",
      "value": "Tenda AX1803 v1.0.0.1 contiene un desbordamiento de pila a trav\u00e9s del par\u00e1metro iptv.stb.mode en la funci\u00f3n setIptvInfo."
    }
  ],
  "id": "CVE-2023-51962",
  "lastModified": "2025-04-17T16:15:27.027",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-01-10T16:15:49.763",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-setIptvInfo-944beaf189db4bf49f99a7a7418c7bdd"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-setIptvInfo-944beaf189db4bf49f99a7a7418c7bdd"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2023-51967

Vulnerability from fkie_nvd - Published: 2024-01-10 16:15 - Updated: 2025-06-20 16:15
Summary
Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.port parameter in the function getIptvInfo.
Impacted products
Vendor Product Version
tenda ax1803_firmware 1.0.0.1
tenda ax1803 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ax1803_firmware:1.0.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "B81C53EE-14CD-426B-ADF3-6D9B4D69DC84",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "413B93A8-6188-4D89-8141-C5B73F4AA071",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the iptv.stb.port parameter in the function getIptvInfo."
    },
    {
      "lang": "es",
      "value": "Tenda AX1803 v1.0.0.1 contiene un desbordamiento de pila a trav\u00e9s del par\u00e1metro iptv.stb.port en la funci\u00f3n getIptvInfo."
    }
  ],
  "id": "CVE-2023-51967",
  "lastModified": "2025-06-20T16:15:27.247",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-01-10T16:15:49.840",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-getIptvInfo-f5918cc2828c49e78554f456bf7d4b36"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-getIptvInfo-f5918cc2828c49e78554f456bf7d4b36"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

FKIE_CVE-2023-51959

Vulnerability from fkie_nvd - Published: 2024-01-10 15:15 - Updated: 2025-04-17 16:15
Summary
Tenda AX1803 v1.0.0.1 contains a stack overflow via the adv.iptv.stbpvid parameter in the function formGetIptv.
Impacted products
Vendor Product Version
tenda ax1803_firmware 1.0.0.1
tenda ax1803 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:tenda:ax1803_firmware:1.0.0.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "B81C53EE-14CD-426B-ADF3-6D9B4D69DC84",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "413B93A8-6188-4D89-8141-C5B73F4AA071",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the adv.iptv.stbpvid parameter in the function formGetIptv."
    },
    {
      "lang": "es",
      "value": "Tenda AX1803 v1.0.0.1 contiene un desbordamiento de pila a trav\u00e9s del par\u00e1metro adv.iptv.stbpvid en la funci\u00f3n formGetIptv."
    }
  ],
  "id": "CVE-2023-51959",
  "lastModified": "2025-04-17T16:15:26.863",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-01-10T15:15:09.347",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-formGetIptv-0fcc584fcda44b1c837e42d5d732957a"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://grove-laser-8ad.notion.site/Tenda-AX1803-Buffer-Overflow-in-formGetIptv-0fcc584fcda44b1c837e42d5d732957a"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
      "type": "Secondary"
    }
  ]
}

CVE-2025-63457 (GCVE-0-2025-63457)

Vulnerability from cvelistv5 – Published: 2025-11-10 00:00 – Updated: 2025-11-18 16:33
VLAI?
Summary
Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the wanMTU parameter in the sub_4F55C function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-63457",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-12T17:05:45.526528Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-18T16:33:49.614Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the wanMTU parameter in the sub_4F55C function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-10T16:13:26.686Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/1/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-63457",
    "datePublished": "2025-11-10T00:00:00.000Z",
    "dateReserved": "2025-10-27T00:00:00.000Z",
    "dateUpdated": "2025-11-18T16:33:49.614Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-63456 (GCVE-0-2025-63456)

Vulnerability from cvelistv5 – Published: 2025-11-10 00:00 – Updated: 2025-11-18 16:27
VLAI?
Summary
Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the time parameter in the SetSysTimeCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-63456",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-18T16:27:20.923514Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-18T16:27:47.818Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the time parameter in the SetSysTimeCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-10T16:38:44.379Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/3/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-63456",
    "datePublished": "2025-11-10T00:00:00.000Z",
    "dateReserved": "2025-10-27T00:00:00.000Z",
    "dateUpdated": "2025-11-18T16:27:47.818Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-63458 (GCVE-0-2025-63458)

Vulnerability from cvelistv5 – Published: 2025-10-31 00:00 – Updated: 2025-11-03 14:53
VLAI?
Summary
Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the timeZone parameter in the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-63458",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-03T14:29:34.961702Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-03T14:53:13.747Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/2/1.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the timeZone parameter in the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-31T18:55:13.569Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/2/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-63458",
    "datePublished": "2025-10-31T00:00:00.000Z",
    "dateReserved": "2025-10-27T00:00:00.000Z",
    "dateUpdated": "2025-11-03T14:53:13.747Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-7598 (GCVE-0-2025-7598)

Vulnerability from cvelistv5 – Published: 2025-07-14 11:02 – Updated: 2025-07-14 12:43
VLAI?
Summary
A vulnerability classified as critical was found in Tenda AX1803 1.0.0.1. Affected by this vulnerability is the function formSetWifiMacFilterCfg of the file /goform/setWifiFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda AX1803 Affected: 1.0.0.1
Create a notification for this product.
Credits
panda_0x1 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7598",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-14T12:42:00.366931Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-14T12:43:01.808Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AX1803",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.0.1"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "panda_0x1 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in Tenda AX1803 1.0.0.1. Affected by this vulnerability is the function formSetWifiMacFilterCfg of the file /goform/setWifiFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AX1803 1.0.0.1 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion formSetWifiMacFilterCfg der Datei /goform/setWifiFilterCfg. Durch die Manipulation des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-14T11:02:07.422Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-316297 | Tenda AX1803 setWifiFilterCfg formSetWifiMacFilterCfg stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.316297"
        },
        {
          "name": "VDB-316297 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.316297"
        },
        {
          "name": "Submit #615269 | Tenda AX1803 V1.0.0.1 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.615269"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetWifiMacFilterCfg.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetWifiMacFilterCfg.md#poc"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-07-13T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-07-13T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-07-13T15:18:28.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AX1803 setWifiFilterCfg formSetWifiMacFilterCfg stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-7598",
    "datePublished": "2025-07-14T11:02:07.422Z",
    "dateReserved": "2025-07-13T13:13:20.225Z",
    "dateUpdated": "2025-07-14T12:43:01.808Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-7597 (GCVE-0-2025-7597)

Vulnerability from cvelistv5 – Published: 2025-07-14 10:44 – Updated: 2025-07-14 12:46
VLAI?
Summary
A vulnerability classified as critical has been found in Tenda AX1803 1.0.0.1. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda AX1803 Affected: 1.0.0.1
Create a notification for this product.
Credits
panda_0x1 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7597",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-14T12:46:37.870432Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-14T12:46:49.239Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AX1803",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.0.1"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "panda_0x1 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Tenda AX1803 1.0.0.1. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda AX1803 1.0.0.1 entdeckt. Hiervon betroffen ist die Funktion formSetMacFilterCfg der Datei /goform/setMacFilterCfg. Mit der Manipulation des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-14T10:44:06.851Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-316296 | Tenda AX1803 setMacFilterCfg formSetMacFilterCfg stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.316296"
        },
        {
          "name": "VDB-316296 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.316296"
        },
        {
          "name": "Submit #615268 | Tenda AX1803 V1.0.0.1 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.615268"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetMacFilterCfg.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetMacFilterCfg.md#poc"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-07-13T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-07-13T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-07-13T15:18:26.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AX1803 setMacFilterCfg formSetMacFilterCfg stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-7597",
    "datePublished": "2025-07-14T10:44:06.851Z",
    "dateReserved": "2025-07-13T13:13:17.958Z",
    "dateUpdated": "2025-07-14T12:46:49.239Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4236 (GCVE-0-2024-4236)

Vulnerability from cvelistv5 – Published: 2024-04-26 17:31 – Updated: 2024-08-01 20:33
VLAI?
Summary
A vulnerability, which was classified as critical, has been found in Tenda AX1803 1.0.0.1. This issue affects the function formSetSysToolDDNS of the file /goform/SetDDNSCfg. The manipulation of the argument serverName/ddnsUser/ddnsPwd/ddnsDomain leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda AX1803 Affected: 1.0.0.1
Create a notification for this product.
Credits
wxhwxhwxh_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ax1803",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "-"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4236",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-29T11:41:30.994135Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:56:20.941Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.983Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-262127 | Tenda AX1803 SetDDNSCfg formSetSysToolDDNS stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.262127"
          },
          {
            "name": "VDB-262127 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.262127"
          },
          {
            "name": "Submit #319230 | Tenda AX1803 V1.0.0.1 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.319230"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AX/AX1803/formSetSysToolDDNS.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AX1803",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.0.1"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Tenda AX1803 1.0.0.1. This issue affects the function formSetSysToolDDNS of the file /goform/SetDDNSCfg. The manipulation of the argument serverName/ddnsUser/ddnsPwd/ddnsDomain leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AX1803 1.0.0.1 entdeckt. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion formSetSysToolDDNS der Datei /goform/SetDDNSCfg. Durch Manipulieren des Arguments serverName/ddnsUser/ddnsPwd/ddnsDomain mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-26T17:31:09.607Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-262127 | Tenda AX1803 SetDDNSCfg formSetSysToolDDNS stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.262127"
        },
        {
          "name": "VDB-262127 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.262127"
        },
        {
          "name": "Submit #319230 | Tenda AX1803 V1.0.0.1 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.319230"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AX/AX1803/formSetSysToolDDNS.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-26T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-26T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-26T14:45:58.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AX1803 SetDDNSCfg formSetSysToolDDNS stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4236",
    "datePublished": "2024-04-26T17:31:09.607Z",
    "dateReserved": "2024-04-26T12:39:58.408Z",
    "dateUpdated": "2024-08-01T20:33:52.983Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-30621 (GCVE-0-2024-30621)

Vulnerability from cvelistv5 – Published: 2024-04-02 00:00 – Updated: 2024-08-19 19:24
VLAI?
Summary
Tenda AX1803 v1.0.0.1 contains a stack overflow via the serverName parameter in the function fromAdvSetMacMtuWan.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:39:00.719Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serverName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ax1803_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ax1803_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.0.1"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-30621",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-02T15:30:54.859137Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-19T19:24:45.965Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the serverName parameter in the function fromAdvSetMacMtuWan."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-02T13:29:05.486903",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serverName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-30621",
    "datePublished": "2024-04-02T00:00:00",
    "dateReserved": "2024-03-27T00:00:00",
    "dateUpdated": "2024-08-19T19:24:45.965Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-30620 (GCVE-0-2024-30620)

Vulnerability from cvelistv5 – Published: 2024-04-02 00:00 – Updated: 2025-03-25 14:16
VLAI?
Summary
Tenda AX1803 v1.0.0.1 contains a stack overflow via the serviceName parameter in the function fromAdvSetMacMtuWan.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ax1803",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "v1.0.0.1"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-30620",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-03T14:11:25.854407Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-120",
                "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-25T14:16:22.151Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:39:00.886Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serviceName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the serviceName parameter in the function fromAdvSetMacMtuWan."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-02T13:30:12.537Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serviceName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-30620",
    "datePublished": "2024-04-02T00:00:00.000Z",
    "dateReserved": "2024-03-27T00:00:00.000Z",
    "dateUpdated": "2025-03-25T14:16:22.151Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-63457 (GCVE-0-2025-63457)

Vulnerability from nvd – Published: 2025-11-10 00:00 – Updated: 2025-11-18 16:33
VLAI?
Summary
Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the wanMTU parameter in the sub_4F55C function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-63457",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-12T17:05:45.526528Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-18T16:33:49.614Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the wanMTU parameter in the sub_4F55C function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-10T16:13:26.686Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/1/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-63457",
    "datePublished": "2025-11-10T00:00:00.000Z",
    "dateReserved": "2025-10-27T00:00:00.000Z",
    "dateUpdated": "2025-11-18T16:33:49.614Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-63456 (GCVE-0-2025-63456)

Vulnerability from nvd – Published: 2025-11-10 00:00 – Updated: 2025-11-18 16:27
VLAI?
Summary
Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the time parameter in the SetSysTimeCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-63456",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-18T16:27:20.923514Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-18T16:27:47.818Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the time parameter in the SetSysTimeCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-10T16:38:44.379Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/3/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-63456",
    "datePublished": "2025-11-10T00:00:00.000Z",
    "dateReserved": "2025-10-27T00:00:00.000Z",
    "dateUpdated": "2025-11-18T16:27:47.818Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-63458 (GCVE-0-2025-63458)

Vulnerability from nvd – Published: 2025-10-31 00:00 – Updated: 2025-11-03 14:53
VLAI?
Summary
Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the timeZone parameter in the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-63458",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-03T14:29:34.961702Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-03T14:53:13.747Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/2/1.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AX-1803 v1.0.0.1 was discovered to contain a stack overflow via the timeZone parameter in the form_fast_setting_wifi_set function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-31T18:55:13.569Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/0-fool/VulnbyCola/blob/main/Tenda/AX-1803/2/1.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-63458",
    "datePublished": "2025-10-31T00:00:00.000Z",
    "dateReserved": "2025-10-27T00:00:00.000Z",
    "dateUpdated": "2025-11-03T14:53:13.747Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-7598 (GCVE-0-2025-7598)

Vulnerability from nvd – Published: 2025-07-14 11:02 – Updated: 2025-07-14 12:43
VLAI?
Summary
A vulnerability classified as critical was found in Tenda AX1803 1.0.0.1. Affected by this vulnerability is the function formSetWifiMacFilterCfg of the file /goform/setWifiFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda AX1803 Affected: 1.0.0.1
Create a notification for this product.
Credits
panda_0x1 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7598",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-14T12:42:00.366931Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-14T12:43:01.808Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AX1803",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.0.1"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "panda_0x1 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in Tenda AX1803 1.0.0.1. Affected by this vulnerability is the function formSetWifiMacFilterCfg of the file /goform/setWifiFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "In Tenda AX1803 1.0.0.1 wurde eine kritische Schwachstelle entdeckt. Betroffen ist die Funktion formSetWifiMacFilterCfg der Datei /goform/setWifiFilterCfg. Durch die Manipulation des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-14T11:02:07.422Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-316297 | Tenda AX1803 setWifiFilterCfg formSetWifiMacFilterCfg stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.316297"
        },
        {
          "name": "VDB-316297 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.316297"
        },
        {
          "name": "Submit #615269 | Tenda AX1803 V1.0.0.1 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.615269"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetWifiMacFilterCfg.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetWifiMacFilterCfg.md#poc"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-07-13T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-07-13T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-07-13T15:18:28.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AX1803 setWifiFilterCfg formSetWifiMacFilterCfg stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-7598",
    "datePublished": "2025-07-14T11:02:07.422Z",
    "dateReserved": "2025-07-13T13:13:20.225Z",
    "dateUpdated": "2025-07-14T12:43:01.808Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-7597 (GCVE-0-2025-7597)

Vulnerability from nvd – Published: 2025-07-14 10:44 – Updated: 2025-07-14 12:46
VLAI?
Summary
A vulnerability classified as critical has been found in Tenda AX1803 1.0.0.1. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
Tenda AX1803 Affected: 1.0.0.1
Create a notification for this product.
Credits
panda_0x1 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7597",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-14T12:46:37.870432Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-14T12:46:49.239Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AX1803",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.0.1"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "panda_0x1 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical has been found in Tenda AX1803 1.0.0.1. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine kritische Schwachstelle in Tenda AX1803 1.0.0.1 entdeckt. Hiervon betroffen ist die Funktion formSetMacFilterCfg der Datei /goform/setMacFilterCfg. Mit der Manipulation des Arguments deviceList mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-14T10:44:06.851Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-316296 | Tenda AX1803 setMacFilterCfg formSetMacFilterCfg stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.316296"
        },
        {
          "name": "VDB-316296 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.316296"
        },
        {
          "name": "Submit #615268 | Tenda AX1803 V1.0.0.1 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.615268"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetMacFilterCfg.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/panda666-888/vuls/blob/main/tenda/ax1803/formSetMacFilterCfg.md#poc"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.tenda.com.cn/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-07-13T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-07-13T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-07-13T15:18:26.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AX1803 setMacFilterCfg formSetMacFilterCfg stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-7597",
    "datePublished": "2025-07-14T10:44:06.851Z",
    "dateReserved": "2025-07-13T13:13:17.958Z",
    "dateUpdated": "2025-07-14T12:46:49.239Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-4236 (GCVE-0-2024-4236)

Vulnerability from nvd – Published: 2024-04-26 17:31 – Updated: 2024-08-01 20:33
VLAI?
Summary
A vulnerability, which was classified as critical, has been found in Tenda AX1803 1.0.0.1. This issue affects the function formSetSysToolDDNS of the file /goform/SetDDNSCfg. The manipulation of the argument serverName/ddnsUser/ddnsPwd/ddnsDomain leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Vendor Product Version
Tenda AX1803 Affected: 1.0.0.1
Create a notification for this product.
Credits
wxhwxhwxh_mie (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ax1803",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "-"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-4236",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-29T11:41:30.994135Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:56:20.941Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T20:33:52.983Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "VDB-262127 | Tenda AX1803 SetDDNSCfg formSetSysToolDDNS stack-based overflow",
            "tags": [
              "vdb-entry",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.262127"
          },
          {
            "name": "VDB-262127 | CTI Indicators (IOB, IOC, IOA)",
            "tags": [
              "signature",
              "permissions-required",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?ctiid.262127"
          },
          {
            "name": "Submit #319230 | Tenda AX1803 V1.0.0.1 Buffer Overflow",
            "tags": [
              "third-party-advisory",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?submit.319230"
          },
          {
            "tags": [
              "exploit",
              "x_transferred"
            ],
            "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AX/AX1803/formSetSysToolDDNS.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AX1803",
          "vendor": "Tenda",
          "versions": [
            {
              "status": "affected",
              "version": "1.0.0.1"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "wxhwxhwxh_mie (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Tenda AX1803 1.0.0.1. This issue affects the function formSetSysToolDDNS of the file /goform/SetDDNSCfg. The manipulation of the argument serverName/ddnsUser/ddnsPwd/ddnsDomain leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262127. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Tenda AX1803 1.0.0.1 entdeckt. Sie wurde als kritisch eingestuft. Dies betrifft die Funktion formSetSysToolDDNS der Datei /goform/SetDDNSCfg. Durch Manipulieren des Arguments serverName/ddnsUser/ddnsPwd/ddnsDomain mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121 Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-26T17:31:09.607Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-262127 | Tenda AX1803 SetDDNSCfg formSetSysToolDDNS stack-based overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.262127"
        },
        {
          "name": "VDB-262127 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.262127"
        },
        {
          "name": "Submit #319230 | Tenda AX1803 V1.0.0.1 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.319230"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AX/AX1803/formSetSysToolDDNS.md"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-04-26T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-04-26T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-04-26T14:45:58.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Tenda AX1803 SetDDNSCfg formSetSysToolDDNS stack-based overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-4236",
    "datePublished": "2024-04-26T17:31:09.607Z",
    "dateReserved": "2024-04-26T12:39:58.408Z",
    "dateUpdated": "2024-08-01T20:33:52.983Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-30621 (GCVE-0-2024-30621)

Vulnerability from nvd – Published: 2024-04-02 00:00 – Updated: 2024-08-19 19:24
VLAI?
Summary
Tenda AX1803 v1.0.0.1 contains a stack overflow via the serverName parameter in the function fromAdvSetMacMtuWan.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:39:00.719Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serverName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:tenda:ax1803_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ax1803_firmware",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "1.0.0.1"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-30621",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-02T15:30:54.859137Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-121",
                "description": "CWE-121 Stack-based Buffer Overflow",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-19T19:24:45.965Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the serverName parameter in the function fromAdvSetMacMtuWan."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-02T13:29:05.486903",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serverName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-30621",
    "datePublished": "2024-04-02T00:00:00",
    "dateReserved": "2024-03-27T00:00:00",
    "dateUpdated": "2024-08-19T19:24:45.965Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-30620 (GCVE-0-2024-30620)

Vulnerability from nvd – Published: 2024-04-02 00:00 – Updated: 2025-03-25 14:16
VLAI?
Summary
Tenda AX1803 v1.0.0.1 contains a stack overflow via the serviceName parameter in the function fromAdvSetMacMtuWan.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:tenda:ax1803:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "ax1803",
            "vendor": "tenda",
            "versions": [
              {
                "status": "affected",
                "version": "v1.0.0.1"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-30620",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-03T14:11:25.854407Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-120",
                "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-25T14:16:22.151Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:39:00.886Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serviceName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AX1803 v1.0.0.1 contains a stack overflow via the serviceName parameter in the function fromAdvSetMacMtuWan."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-02T13:30:12.537Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/re1wn/IoT_vuln/blob/main/Tenda_AX1803_v1.0.0.1_contains_a_stack_overflow_via_the_serviceName_parameter_in_the_function_fromAdvSetMacMtuWan.md"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-30620",
    "datePublished": "2024-04-02T00:00:00.000Z",
    "dateReserved": "2024-03-27T00:00:00.000Z",
    "dateUpdated": "2025-03-25T14:16:22.151Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}