Search

Find a vulnerability

Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    8 vulnerabilities found for base_software by abb

    CVE-2021-22277 (GCVE-0-2021-22277)

    Vulnerability from cvelistv5 – Published: 2022-04-01 22:17 – Updated: 2024-09-17 01:41
    VLAI
    Title
    AC 800M MMS - Denial of Service vulnerability in MMS communication
    Summary
    Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service.
    CWE
    • CWE-20 - Improper Input Validation
    Assigner
    ABB
    References
    Impacted products
    Vendor Product Version
    ABB 800xA, Control Software for AC 800M Affected: 5.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.0-3 (custom)
    Affected: 5.1.1-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.1-4 (custom)
    Affected: 6.0.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.0.0-3 (custom)
    Affected: 6.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.1.1-1 (custom)
    Create a notification for this product.
    ABB Control Builder Safe Affected: 1.x
    Affected: 2.0
    Affected: 3.0
    Create a notification for this product.
    ABB Compact Product Suite - Control and I/O Affected: 5.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.0-3 (custom)
    Affected: 5.1.1-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.1-4 (custom)
    Affected: 6.0.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.0.0-3 (custom)
    Affected: 6.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.1.1-1 (custom)
    Create a notification for this product.
    ABB ABB Base Software for SoftControl Affected: 5.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.0-3 (custom)
    Affected: 5.1.1-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.1-4 (custom)
    Affected: 6.0.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.0.0-3 (custom)
    Affected: 6.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.1.1-1 (custom)
    Create a notification for this product.
    Date Public
    2022-02-17 00:00
    Credits
    ABB thanks the Industrial Control Security Laboratory of Qi An Xin Technology Group Inc. in China for helping to identify the vulnerabilities and protecting our customers.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T18:37:18.475Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "800xA, Control Software for AC 800M",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.1-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.1-4",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.0.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.0.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1-1",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Control Builder Safe",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.x"
                },
                {
                  "status": "affected",
                  "version": "2.0"
                },
                {
                  "status": "affected",
                  "version": "3.0"
                }
              ]
            },
            {
              "product": "Compact Product Suite - Control and I/O",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.1-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.1-4",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.0.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.0.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1-1",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "ABB Base Software for SoftControl",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.1-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.1-4",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.0.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.0.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1-1",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "ABB thanks the Industrial Control Security Laboratory of Qi An Xin Technology Group Inc. in China for helping to identify the vulnerabilities and protecting our customers."
            }
          ],
          "datePublic": "2022-02-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-01T22:17:43.000Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "AC 800M MMS - Denial of Service vulnerability in MMS communication",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@ch.abb.com",
              "DATE_PUBLIC": "2022-02-17T10:33:00.000Z",
              "ID": "CVE-2021-22277",
              "STATE": "PUBLIC",
              "TITLE": "AC 800M MMS - Denial of Service vulnerability in MMS communication"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "800xA, Control Software for AC 800M",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.1-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.1-4"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.0.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.0.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.1.1-1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Control Builder Safe",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.x"
                              },
                              {
                                "version_affected": "=",
                                "version_value": "2.0"
                              },
                              {
                                "version_affected": "=",
                                "version_value": "3.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Compact Product Suite - Control and I/O",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.1-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.1-4"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.0.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.0.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.1.1-1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "ABB Base Software for SoftControl",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.1-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.1-4"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.0.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.0.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.1.1-1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ABB"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "ABB thanks the Industrial Control Security Laboratory of Qi An Xin Technology Group Inc. in China for helping to identify the vulnerabilities and protecting our customers."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-20 Improper Input Validation"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "MISC",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2021-22277",
        "datePublished": "2022-04-01T22:17:43.044Z",
        "dateReserved": "2021-01-05T00:00:00.000Z",
        "dateUpdated": "2024-09-17T01:41:41.993Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-24672 (GCVE-0-2020-24672)

    Vulnerability from cvelistv5 – Published: 2021-09-08 15:03 – Updated: 2024-09-17 00:50
    VLAI
    Title
    ABB Base Software for SoftControl Remote Code Execution vulnerability
    Summary
    A vulnerability in Base Software for SoftControl allows an attacker to insert and run arbitrary code in a computer running the affected product. This issue affects: .
    CWE
    • CWE-862 - Missing Authorization
    • CWE-345 - Insufficient Verification of Data Authenticity
    Assigner
    ABB
    References
    Impacted products
    Vendor Product Version
    ABB Base Software for SoftControl Affected: 6.1 , ≤ 6.1 (custom)
    Create a notification for this product.
    Date Public
    2021-09-03 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T15:19:08.954Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA122974\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Base Software for SoftControl",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "6.1",
                  "status": "affected",
                  "version": "6.1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-09-03T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability in Base Software for SoftControl allows an attacker to insert and run arbitrary code in a computer running the affected product. This issue affects: ."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-862",
                  "description": "CWE-862 Missing Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-345",
                  "description": "CWE-345 Insufficient Verification of Data Authenticity",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-09-08T15:03:55.000Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA122974\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "ABB Base Software for SoftControl Remote Code Execution vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@ch.abb.com",
              "DATE_PUBLIC": "2021-09-03T06:54:00.000Z",
              "ID": "CVE-2020-24672",
              "STATE": "PUBLIC",
              "TITLE": "ABB Base Software for SoftControl Remote Code Execution vulnerability"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Base Software for SoftControl",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "6.1",
                                "version_value": "6.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ABB"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability in Base Software for SoftControl allows an attacker to insert and run arbitrary code in a computer running the affected product. This issue affects: ."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-862 Missing Authorization"
                    }
                  ]
                },
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-345 Insufficient Verification of Data Authenticity"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA122974\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "MISC",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA122974\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                }
              ]
            },
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2020-24672",
        "datePublished": "2021-09-08T15:03:55.810Z",
        "dateReserved": "2020-08-26T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:50:49.998Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-8478 (GCVE-0-2020-8478)

    Vulnerability from cvelistv5 – Published: 2020-04-29 01:58 – Updated: 2024-08-04 10:03
    VLAI
    Title
    ABB System 800xA Inter process communication vulnerability
    Summary
    Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder.
    CWE
    • CWE-264 - Permissions, Privileges, and Access Controls
    Assigner
    ABB
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T10:03:44.802Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "OPC Server for AC 800M",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "product": "MMS Server for AC 800M",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "product": "Base Software for SoftControl",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-264",
                  "description": "CWE-264 Permissions, Privileges, and Access Controls",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-29T01:58:54.000Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "ABB System 800xA Inter process communication vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@ch.abb.com",
              "ID": "CVE-2020-8478",
              "STATE": "PUBLIC",
              "TITLE": "ABB System 800xA Inter process communication vulnerability"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "OPC Server for AC 800M",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "undefined",
                                "version_value": "all versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MMS Server for AC 800M",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "undefined",
                                "version_value": "all versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Base Software for SoftControl",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "undefined",
                                "version_value": "all versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ABB"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-264 Permissions, Privileges, and Access Controls"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "CONFIRM",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2020-8478",
        "datePublished": "2020-04-29T01:58:54.000Z",
        "dateReserved": "2020-01-30T00:00:00.000Z",
        "dateUpdated": "2024-08-04T10:03:44.802Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-8472 (GCVE-0-2020-8472)

    Vulnerability from cvelistv5 – Published: 2020-04-28 23:52 – Updated: 2024-08-04 10:03
    VLAI
    Title
    ABB System 800xA Weak File Permissions - different products
    Summary
    Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploited the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications.
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Assigner
    ABB
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T10:03:45.938Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "OPC Server for AC 800M",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.0 and earlier"
                }
              ]
            },
            {
              "product": "Control Builder M Professional",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.1 and earlier"
                }
              ]
            },
            {
              "product": "MMS Server for AC 800M",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.1 and earlier"
                }
              ]
            },
            {
              "product": "Base Software for SoftControl",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.1 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploited the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-28T23:52:41.000Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "ABB System 800xA Weak File Permissions - different products",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@ch.abb.com",
              "ID": "CVE-2020-8472",
              "STATE": "PUBLIC",
              "TITLE": "ABB System 800xA Weak File Permissions - different products"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "OPC Server for AC 800M",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "6.0 and earlier"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Control Builder M Professional",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "6.1 and earlier"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MMS Server for AC 800M",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "6.1 and earlier"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Base Software for SoftControl",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "6.1 and earlier"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ABB"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploited the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-732 Incorrect Permission Assignment for Critical Resource"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "CONFIRM",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2020-8472",
        "datePublished": "2020-04-28T23:52:41.000Z",
        "dateReserved": "2020-01-30T00:00:00.000Z",
        "dateUpdated": "2024-08-04T10:03:45.938Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-22277 (GCVE-0-2021-22277)

    Vulnerability from nvd – Published: 2022-04-01 22:17 – Updated: 2024-09-17 01:41
    VLAI
    Title
    AC 800M MMS - Denial of Service vulnerability in MMS communication
    Summary
    Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service.
    CWE
    • CWE-20 - Improper Input Validation
    Assigner
    ABB
    References
    Impacted products
    Vendor Product Version
    ABB 800xA, Control Software for AC 800M Affected: 5.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.0-3 (custom)
    Affected: 5.1.1-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.1-4 (custom)
    Affected: 6.0.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.0.0-3 (custom)
    Affected: 6.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.1.1-1 (custom)
    Create a notification for this product.
    ABB Control Builder Safe Affected: 1.x
    Affected: 2.0
    Affected: 3.0
    Create a notification for this product.
    ABB Compact Product Suite - Control and I/O Affected: 5.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.0-3 (custom)
    Affected: 5.1.1-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.1-4 (custom)
    Affected: 6.0.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.0.0-3 (custom)
    Affected: 6.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.1.1-1 (custom)
    Create a notification for this product.
    ABB ABB Base Software for SoftControl Affected: 5.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.0-3 (custom)
    Affected: 5.1.1-0 , < unspecified (custom)
    Affected: unspecified , ≤ 5.1.1-4 (custom)
    Affected: 6.0.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.0.0-3 (custom)
    Affected: 6.1.0-0 , < unspecified (custom)
    Affected: unspecified , ≤ 6.1.1-1 (custom)
    Create a notification for this product.
    Date Public
    2022-02-17 00:00
    Credits
    ABB thanks the Industrial Control Security Laboratory of Qi An Xin Technology Group Inc. in China for helping to identify the vulnerabilities and protecting our customers.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T18:37:18.475Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "800xA, Control Software for AC 800M",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.1-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.1-4",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.0.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.0.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1-1",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Control Builder Safe",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.x"
                },
                {
                  "status": "affected",
                  "version": "2.0"
                },
                {
                  "status": "affected",
                  "version": "3.0"
                }
              ]
            },
            {
              "product": "Compact Product Suite - Control and I/O",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.1-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.1-4",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.0.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.0.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1-1",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "ABB Base Software for SoftControl",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "5.1.1-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "5.1.1-4",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.0.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.0.0-3",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                },
                {
                  "lessThan": "unspecified",
                  "status": "affected",
                  "version": "6.1.0-0",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "6.1.1-1",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "ABB thanks the Industrial Control Security Laboratory of Qi An Xin Technology Group Inc. in China for helping to identify the vulnerabilities and protecting our customers."
            }
          ],
          "datePublic": "2022-02-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-01T22:17:43.000Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "AC 800M MMS - Denial of Service vulnerability in MMS communication",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@ch.abb.com",
              "DATE_PUBLIC": "2022-02-17T10:33:00.000Z",
              "ID": "CVE-2021-22277",
              "STATE": "PUBLIC",
              "TITLE": "AC 800M MMS - Denial of Service vulnerability in MMS communication"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "800xA, Control Software for AC 800M",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.1-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.1-4"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.0.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.0.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.1.1-1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Control Builder Safe",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "=",
                                "version_value": "1.x"
                              },
                              {
                                "version_affected": "=",
                                "version_value": "2.0"
                              },
                              {
                                "version_affected": "=",
                                "version_value": "3.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Compact Product Suite - Control and I/O",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.1-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.1-4"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.0.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.0.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.1.1-1"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "ABB Base Software for SoftControl",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "5.1.1-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "5.1.1-4"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.0.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.0.0-3"
                              },
                              {
                                "version_affected": "\u003e=",
                                "version_value": "6.1.0-0"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_value": "6.1.1-1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ABB"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "ABB thanks the Industrial Control Security Laboratory of Qi An Xin Technology Group Inc. in China for helping to identify the vulnerabilities and protecting our customers."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-20 Improper Input Validation"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "MISC",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2021-22277",
        "datePublished": "2022-04-01T22:17:43.044Z",
        "dateReserved": "2021-01-05T00:00:00.000Z",
        "dateUpdated": "2024-09-17T01:41:41.993Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-24672 (GCVE-0-2020-24672)

    Vulnerability from nvd – Published: 2021-09-08 15:03 – Updated: 2024-09-17 00:50
    VLAI
    Title
    ABB Base Software for SoftControl Remote Code Execution vulnerability
    Summary
    A vulnerability in Base Software for SoftControl allows an attacker to insert and run arbitrary code in a computer running the affected product. This issue affects: .
    CWE
    • CWE-862 - Missing Authorization
    • CWE-345 - Insufficient Verification of Data Authenticity
    Assigner
    ABB
    References
    Impacted products
    Vendor Product Version
    ABB Base Software for SoftControl Affected: 6.1 , ≤ 6.1 (custom)
    Create a notification for this product.
    Date Public
    2021-09-03 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T15:19:08.954Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA122974\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Base Software for SoftControl",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "6.1",
                  "status": "affected",
                  "version": "6.1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2021-09-03T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability in Base Software for SoftControl allows an attacker to insert and run arbitrary code in a computer running the affected product. This issue affects: ."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-862",
                  "description": "CWE-862 Missing Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-345",
                  "description": "CWE-345 Insufficient Verification of Data Authenticity",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-09-08T15:03:55.000Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA122974\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "ABB Base Software for SoftControl Remote Code Execution vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@ch.abb.com",
              "DATE_PUBLIC": "2021-09-03T06:54:00.000Z",
              "ID": "CVE-2020-24672",
              "STATE": "PUBLIC",
              "TITLE": "ABB Base Software for SoftControl Remote Code Execution vulnerability"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Base Software for SoftControl",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "6.1",
                                "version_value": "6.1"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ABB"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A vulnerability in Base Software for SoftControl allows an attacker to insert and run arbitrary code in a computer running the affected product. This issue affects: ."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-862 Missing Authorization"
                    }
                  ]
                },
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-345 Insufficient Verification of Data Authenticity"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA122974\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "MISC",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA122974\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                }
              ]
            },
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2020-24672",
        "datePublished": "2021-09-08T15:03:55.810Z",
        "dateReserved": "2020-08-26T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:50:49.998Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-8478 (GCVE-0-2020-8478)

    Vulnerability from nvd – Published: 2020-04-29 01:58 – Updated: 2024-08-04 10:03
    VLAI
    Title
    ABB System 800xA Inter process communication vulnerability
    Summary
    Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder.
    CWE
    • CWE-264 - Permissions, Privileges, and Access Controls
    Assigner
    ABB
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T10:03:44.802Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "OPC Server for AC 800M",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "product": "MMS Server for AC 800M",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            },
            {
              "product": "Base Software for SoftControl",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "all versions"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-264",
                  "description": "CWE-264 Permissions, Privileges, and Access Controls",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-29T01:58:54.000Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "ABB System 800xA Inter process communication vulnerability",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@ch.abb.com",
              "ID": "CVE-2020-8478",
              "STATE": "PUBLIC",
              "TITLE": "ABB System 800xA Inter process communication vulnerability"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "OPC Server for AC 800M",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "undefined",
                                "version_value": "all versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MMS Server for AC 800M",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "undefined",
                                "version_value": "all versions"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Base Software for SoftControl",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "undefined",
                                "version_value": "all versions"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ABB"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Insufficient protection of the inter-process communication functions in ABB System 800xA products OPC Server for AC 800M, MMS Server for AC 800M and Base Software for SoftControl (all published versions) enables an attacker authenticated on the local system to inject data, affecting the online view of runtime data shown in Control Builder."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "LOW",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-264 Permissions, Privileges, and Access Controls"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "CONFIRM",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121236\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2020-8478",
        "datePublished": "2020-04-29T01:58:54.000Z",
        "dateReserved": "2020-01-30T00:00:00.000Z",
        "dateUpdated": "2024-08-04T10:03:44.802Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-8472 (GCVE-0-2020-8472)

    Vulnerability from nvd – Published: 2020-04-28 23:52 – Updated: 2024-08-04 10:03
    VLAI
    Title
    ABB System 800xA Weak File Permissions - different products
    Summary
    Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploited the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications.
    CWE
    • CWE-732 - Incorrect Permission Assignment for Critical Resource
    Assigner
    ABB
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T10:03:45.938Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "OPC Server for AC 800M",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.0 and earlier"
                }
              ]
            },
            {
              "product": "Control Builder M Professional",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.1 and earlier"
                }
              ]
            },
            {
              "product": "MMS Server for AC 800M",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.1 and earlier"
                }
              ]
            },
            {
              "product": "Base Software for SoftControl",
              "vendor": "ABB",
              "versions": [
                {
                  "status": "affected",
                  "version": "6.1 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploited the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-732",
                  "description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-28T23:52:41.000Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "ABB System 800xA Weak File Permissions - different products",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cybersecurity@ch.abb.com",
              "ID": "CVE-2020-8472",
              "STATE": "PUBLIC",
              "TITLE": "ABB System 800xA Weak File Permissions - different products"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "OPC Server for AC 800M",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "6.0 and earlier"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Control Builder M Professional",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "6.1 and earlier"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "MMS Server for AC 800M",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "6.1 and earlier"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Base Software for SoftControl",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "6.1 and earlier"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "ABB"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Insufficient folder permissions used by system functions in ABB System 800xA products OPCServer for AC800M (versions 6.0 and earlier) and Control Builder M Professional, MMSServer for AC800M, Base Software for SoftControl (version 6.1 and earlier) allow low privileged users to read, modify, add and delete system and application files. An authenticated attacker who successfully exploited the vulnerabilities could escalate his/her privileges, cause system functions to stop and to corrupt user applications."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-732 Incorrect Permission Assignment for Critical Resource"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
                  "refsource": "CONFIRM",
                  "url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA121106\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2020-8472",
        "datePublished": "2020-04-28T23:52:41.000Z",
        "dateReserved": "2020-01-30T00:00:00.000Z",
        "dateUpdated": "2024-08-04T10:03:45.938Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }