Search criteria

15 vulnerabilities found for citectscada by schneider-electric

FKIE_CVE-2019-10981

Vulnerability from fkie_nvd - Published: 2019-05-31 21:29 - Updated: 2024-11-21 04:20

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:citectscada:7.30:*:*:*:*:*:*:*",
              "matchCriteriaId": "718E137A-94A1-46E2-B81E-D0812BC4894E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:citectscada:7.40:*:*:*:*:*:*:*",
              "matchCriteriaId": "A21DF1A9-A957-419F-A84B-EB73F1FB15FA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:scada_expert_vijeo_citect:7.30:*:*:*:*:*:*:*",
              "matchCriteriaId": "A005118C-AB06-4F8C-AED5-FB186534C48D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:scada_expert_vijeo_citect:7.40:*:*:*:*:*:*:*",
              "matchCriteriaId": "7DCB46CA-EBF8-4318-9671-B5A5D6DED3CE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials."
    },
    {
      "lang": "es",
      "value": "En los sistemas Vijeo Citect versiones 7.30 y 7.40, y CitectSCADA versiones 7.30 y 7.40, ha sido identificada na vulnerabilidad que puede permitir el acceso a las credenciales de usuario de Citect por parte de un usuario local identificado"
    }
  ],
  "id": "CVE-2019-10981",
  "lastModified": "2024-11-21T04:20:17.440",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "LOW",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 2.1,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "NONE",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-05-31T21:29:02.267",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/108543"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-150-01"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityAdvisory_LFSec136.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "http://www.securityfocus.com/bid/108543"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Mitigation",
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-150-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityAdvisory_LFSec136.pdf"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ],
      "source": "ics-cert@hq.dhs.gov",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-522"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2013-2824

Vulnerability from fkie_nvd - Published: 2014-02-26 14:55 - Updated: 2025-04-11 00:51
Severity ?
Summary
Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:citectscada:7.20:*:*:*:*:*:*:*",
              "matchCriteriaId": "85E1560F-CE61-43C7-A27C-D3686CA72BD0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:citectscada:7.20:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "AF696E7E-CDF7-47D2-9FBD-9DBB30BCE08C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:citectscada:7.20:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "F1DBFCBD-0579-446E-BD2C-AA1B52431D37",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:citectscada:7.20:sp3:*:*:*:*:*:*",
              "matchCriteriaId": "DF858200-D4C1-4D4F-97AA-D4B5BFF0A3CF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:citectscada:7.20:sp4:*:*:*:*:*:*",
              "matchCriteriaId": "52088B8C-B557-4097-83BE-370DAF129026",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:citectscada:7.30:*:*:*:*:*:*:*",
              "matchCriteriaId": "718E137A-94A1-46E2-B81E-D0812BC4894E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:citectscada:7.30:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "DF6657FA-764B-4691-B700-9852A75AE881",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:powerlogic_scada:7.20:*:*:*:*:*:*:*",
              "matchCriteriaId": "2C74D4F5-1C73-4033-9973-7D7106E6C3C6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:powerlogic_scada:7.20:sr1:*:*:*:*:*:*",
              "matchCriteriaId": "5B691D29-97DC-454A-99F3-EC31FB98BC82",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:struxureware_powerscada_expert:7.30:*:*:*:*:*:*:*",
              "matchCriteriaId": "71083E51-84C8-419D-AC35-210EC93E515B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:struxureware_powerscada_expert:7.30:sr1:*:*:*:*:*:*",
              "matchCriteriaId": "A4CB3741-1542-4C78-B09E-D0D31B9047BE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:struxureware_scada_expert_vijeo_citect:7.20:*:*:*:*:*:*:*",
              "matchCriteriaId": "D9E10889-7704-4A82-AAEA-FBAF978258C0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:struxureware_scada_expert_vijeo_citect:7.20:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "49D00E90-1B10-42E9-A9C8-E5F31FC5BAAF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:struxureware_scada_expert_vijeo_citect:7.20:sp2:*:*:*:*:*:*",
              "matchCriteriaId": "75A67DDD-FE24-47AE-92D4-1459D0299BD2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:struxureware_scada_expert_vijeo_citect:7.20:sp3:*:*:*:*:*:*",
              "matchCriteriaId": "566C70EA-5DBB-4369-9ABF-1B9E07A2BFBF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:struxureware_scada_expert_vijeo_citect:7.20:sp4:*:*:*:*:*:*",
              "matchCriteriaId": "A4527018-6D0A-4962-9116-A4E24040993A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:struxureware_scada_expert_vijeo_citect:7.30:*:*:*:*:*:*:*",
              "matchCriteriaId": "3CB801EA-39C9-495A-B405-66275CB7EACC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:struxureware_scada_expert_vijeo_citect:7.30:sp1:*:*:*:*:*:*",
              "matchCriteriaId": "645AE8E1-2F56-4EF1-B792-E70BA405BE42",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:struxureware_scada_expert_vijeo_citect:7.40:*:*:*:*:*:*:*",
              "matchCriteriaId": "6C3C1AE1-9CF1-4DB0-A027-91DAFAEFF706",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet."
    },
    {
      "lang": "es",
      "value": "Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 hasta 7.30SP1, CitectSCADA 7.20 hasta 7.30SP1, StruxureWare PowerSCADA Expert 7.30 hasta 7.30SR1 y PowerLogic SCADA 7.20 hasta 7.20SR1 no manejan debidamente las excepciones, lo que permite a atacantes remotos causar una denegaci\u00f3n de servicio a trav\u00e9s de un paquete manipulado."
    }
  ],
  "id": "CVE-2013-2824",
  "lastModified": "2025-04-11T00:51:21.963",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2014-02-26T14:55:08.147",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "US Government Resource"
      ],
      "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-350-01"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.citect.schneider-electric.com/security-DoS"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "US Government Resource"
      ],
      "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-350-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "http://www.citect.schneider-electric.com/security-DoS"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-Other"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2013-2796

Vulnerability from fkie_nvd - Published: 2013-08-09 23:55 - Updated: 2025-04-11 00:51
Severity ?
Summary
Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:schneider-electric:citectscada:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F38EF72-DCCB-47DE-AF76-73A78D9F069A",
              "versionEndIncluding": "7.20",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:citectscada:7.10:*:*:*:*:*:*:*",
              "matchCriteriaId": "E87F308E-8874-40CD-BB46-9CD955AEE26E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:powerlogic_scada:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "692487FE-D5CC-4289-8C4B-26C30C12BB08",
              "versionEndIncluding": "7.20",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:powerlogic_scada:7.10:*:*:*:*:*:*:*",
              "matchCriteriaId": "227FA3FF-F09B-4891-9B90-37563E1A579C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:vijeo_citect:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "261173CE-D744-4427-ABCB-AD9BA9CCCF25",
              "versionEndIncluding": "7.20",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:vijeo_citect:7.10:*:*:*:*:*:*:*",
              "matchCriteriaId": "281F678E-1B21-4EFD-A9F6-016FCECF1DA0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue."
    },
    {
      "lang": "es",
      "value": "Schneider Electric Vijeo Citect v7.20 y anteriores, CitectSCADA v7.20 y anteriores, y PowerLogic SCADA v7.20 y anteriores, permite a atacantes remotos leer ficheros, enviar peticiones HTTP a servidores intranet, o causar una denegaci\u00f3n del servicio (consumo de CPU y memoria) a trav\u00e9s de fichero XML que contiene una declaraci\u00f3n de entidad externa, junto con una referencia de entidad, en relaci\u00f3n con un fallo en XML External Entity (XXE)."
    }
  ],
  "evaluatorComment": "Per: http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02\n\n\"This vulnerability is not exploitable remotely.\"",
  "id": "CVE-2013-2796",
  "lastModified": "2025-04-11T00:51:21.963",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 6.9,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:L/AC:M/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 3.4,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2013-08-09T23:55:02.537",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02"
    },
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Patch"
      ],
      "url": "http://www.citect.schneider-electric.com/cs-HF720SP459363"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch"
      ],
      "url": "http://www.citect.schneider-electric.com/cs-HF720SP459363"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-264"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2013-3075

Vulnerability from fkie_nvd - Published: 2013-04-19 11:44 - Updated: 2025-04-11 00:51
Severity ?
Summary
Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishi-automation:mitsubishi_mx_component:3:*:*:*:*:*:*:*",
              "matchCriteriaId": "2210BAF3-06F4-46D5-9C4D-84E03BD03E80",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:citectfacilities:7.10:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF6EFBDF-9831-42D4-8309-73BE79B33DF2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:citectscada:7.10:r1:*:*:*:*:*:*",
              "matchCriteriaId": "99279602-7849-42FE-BDF6-1E7C0973EE57",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control."
    },
    {
      "lang": "es",
      "value": "M\u00faltiples desbordamientos de b\u00fafer en ActUWzd.dll v1.0.0.1 en Mitsubishi MX componente 3, que distribuye en CitectFacilities Citect v7.10 y CitectSCADA v7.10r1, permite a atacantes remotos ejecutar c\u00f3digo arbitrario a trav\u00e9s de una cadena larga, como lo demuestra con un valor largo de la propiedad WzTitle a un determinado ActiveX control."
    }
  ],
  "id": "CVE-2013-3075",
  "lastModified": "2025-04-11T00:51:21.963",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 10.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2013-04-19T11:44:29.280",
  "references": [
    {
      "source": "ics-cert@hq.dhs.gov",
      "tags": [
        "Exploit"
      ],
      "url": "http://www.exploit-db.com/exploits/24886/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit"
      ],
      "url": "http://www.exploit-db.com/exploits/24886/"
    }
  ],
  "sourceIdentifier": "ics-cert@hq.dhs.gov",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2011-5163

Vulnerability from fkie_nvd - Published: 2012-09-15 17:55 - Updated: 2025-04-11 00:51
Severity ?
Summary
Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mitsubishi-automation:mx4_scada:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "395C96CE-DE55-4880-B76C-A6FFAB5F7C29",
              "versionEndIncluding": "7.10",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:schneider-electric:citectscada:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B3CD645-0057-4C5C-B815-A7B50D3387F6",
              "versionEndIncluding": "7.10",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence."
    },
    {
      "lang": "es",
      "value": "Desbordamiento de b\u00fafer en un componente de terceros no especificado en el m\u00f3dulo de ejecuci\u00f3n por lote para Schneider Electric CitectSCADA anterior a v7.20 y Mitsubishi MX4 SCADA anterior a v7.20 permite a usuarios locales ejecutar c\u00f3digo arbitrario a trav\u00e9s de una cadena larga en una secuencia de acceso."
    }
  ],
  "id": "CVE-2011-5163",
  "lastModified": "2025-04-11T00:51:21.963",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.6,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2012-09-15T17:55:04.287",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://secunia.com/advisories/46779"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://secunia.com/advisories/46786"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.citect.com/citectscada-batch"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.osvdb.org/76937"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.securitytracker.com/id?1026306"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf"
    },
    {
      "source": "cve@mitre.org",
      "url": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4%2CSCADA"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://secunia.com/advisories/46779"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://secunia.com/advisories/46786"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.citect.com/citectscada-batch"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.osvdb.org/76937"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.securitytracker.com/id?1026306"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4%2CSCADA"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2019-10981 (GCVE-0-2019-10981)

Vulnerability from cvelistv5 – Published: 2019-05-31 20:59 – Updated: 2024-08-04 22:40
VLAI?
Summary
In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials.
Severity ?
No CVSS data available.
CWE
  • CWE-522 - Insufficiently Protected Credentials CWE-522
Assigner
Impacted products
Vendor Product Version
AVEVA AVEVA Vijeo Citect and CitectSCADA Affected: Vijeo Citect 7.30 and 7.40 CitectSCADA 7.30 and 7.40
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.636Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-150-01"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityAdvisory_LFSec136.pdf"
          },
          {
            "name": "108543",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/108543"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AVEVA Vijeo Citect and CitectSCADA",
          "vendor": "AVEVA",
          "versions": [
            {
              "status": "affected",
              "version": "Vijeo Citect 7.30 and 7.40 CitectSCADA 7.30 and 7.40"
            }
          ]
        }
      ],
      "datePublic": "2019-05-21T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-522",
              "description": "Insufficiently Protected Credentials CWE-522",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-02T12:05:59",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-150-01"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityAdvisory_LFSec136.pdf"
        },
        {
          "name": "108543",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/108543"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2019-10981",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "AVEVA Vijeo Citect and CitectSCADA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Vijeo Citect 7.30 and 7.40 CitectSCADA 7.30 and 7.40"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "AVEVA"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Insufficiently Protected Credentials CWE-522"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-150-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-150-01"
            },
            {
              "name": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityAdvisory_LFSec136.pdf",
              "refsource": "CONFIRM",
              "url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityAdvisory_LFSec136.pdf"
            },
            {
              "name": "108543",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/108543"
            },
            {
              "name": "https://security.cse.iitk.ac.in/responsible-disclosure",
              "refsource": "MISC",
              "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-10981",
    "datePublished": "2019-05-31T20:59:47",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.636Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-2824 (GCVE-0-2013-2824)

Vulnerability from cvelistv5 – Published: 2014-02-26 11:00 – Updated: 2024-08-06 15:52
VLAI?
Summary
Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T15:52:20.055Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.citect.schneider-electric.com/security-DoS"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-350-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2013-12-16T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2014-02-26T02:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.citect.schneider-electric.com/security-DoS"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-350-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-2824",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.citect.schneider-electric.com/security-DoS",
              "refsource": "CONFIRM",
              "url": "http://www.citect.schneider-electric.com/security-DoS"
            },
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-350-01",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-350-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2013-2824",
    "datePublished": "2014-02-26T11:00:00",
    "dateReserved": "2013-04-11T00:00:00",
    "dateUpdated": "2024-08-06T15:52:20.055Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-2796 (GCVE-0-2013-2796)

Vulnerability from cvelistv5 – Published: 2013-08-09 23:00 – Updated: 2024-09-16 18:13
VLAI?
Summary
Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T15:52:21.382Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.citect.schneider-electric.com/cs-HF720SP459363"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-08-09T23:00:00Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.citect.schneider-electric.com/cs-HF720SP459363"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-2796",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.citect.schneider-electric.com/cs-HF720SP459363",
              "refsource": "CONFIRM",
              "url": "http://www.citect.schneider-electric.com/cs-HF720SP459363"
            },
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2013-2796",
    "datePublished": "2013-08-09T23:00:00Z",
    "dateReserved": "2013-04-11T00:00:00Z",
    "dateUpdated": "2024-09-16T18:13:41.217Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-3075 (GCVE-0-2013-3075)

Vulnerability from cvelistv5 – Published: 2013-04-19 10:00 – Updated: 2024-09-17 00:57
VLAI?
Summary
Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
http://www.exploit-db.com/exploits/24886/ exploitx_refsource_EXPLOIT-DB
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:00:09.518Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "24886",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "http://www.exploit-db.com/exploits/24886/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-04-19T10:00:00Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "24886",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "http://www.exploit-db.com/exploits/24886/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-3075",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "24886",
              "refsource": "EXPLOIT-DB",
              "url": "http://www.exploit-db.com/exploits/24886/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2013-3075",
    "datePublished": "2013-04-19T10:00:00Z",
    "dateReserved": "2013-04-15T00:00:00Z",
    "dateUpdated": "2024-09-17T00:57:04.612Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2011-5163 (GCVE-0-2011-5163)

Vulnerability from cvelistv5 – Published: 2012-09-15 17:00 – Updated: 2024-09-17 00:35
VLAI?
Summary
Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
http://www.citect.com/citectscada-batch x_refsource_CONFIRM
http://www.osvdb.org/76937 vdb-entryx_refsource_OSVDB
http://www.us-cert.gov/control_systems/pdf/ICSA-1… x_refsource_MISC
http://secunia.com/advisories/46779 third-party-advisoryx_refsource_SECUNIA
http://www.securitytracker.com/id?1026306 vdb-entryx_refsource_SECTRACK
https://my.mitsubishi-automation.com/downloads_sh… x_refsource_CONFIRM
http://secunia.com/advisories/46786 third-party-advisoryx_refsource_SECUNIA
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-07T00:30:46.763Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.citect.com/citectscada-batch"
          },
          {
            "name": "76937",
            "tags": [
              "vdb-entry",
              "x_refsource_OSVDB",
              "x_transferred"
            ],
            "url": "http://www.osvdb.org/76937"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf"
          },
          {
            "name": "46779",
            "tags": [
              "third-party-advisory",
              "x_refsource_SECUNIA",
              "x_transferred"
            ],
            "url": "http://secunia.com/advisories/46779"
          },
          {
            "name": "1026306",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id?1026306"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4%2CSCADA"
          },
          {
            "name": "46786",
            "tags": [
              "third-party-advisory",
              "x_refsource_SECUNIA",
              "x_transferred"
            ],
            "url": "http://secunia.com/advisories/46786"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-09-15T17:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.citect.com/citectscada-batch"
        },
        {
          "name": "76937",
          "tags": [
            "vdb-entry",
            "x_refsource_OSVDB"
          ],
          "url": "http://www.osvdb.org/76937"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf"
        },
        {
          "name": "46779",
          "tags": [
            "third-party-advisory",
            "x_refsource_SECUNIA"
          ],
          "url": "http://secunia.com/advisories/46779"
        },
        {
          "name": "1026306",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id?1026306"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4%2CSCADA"
        },
        {
          "name": "46786",
          "tags": [
            "third-party-advisory",
            "x_refsource_SECUNIA"
          ],
          "url": "http://secunia.com/advisories/46786"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2011-5163",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.citect.com/citectscada-batch",
              "refsource": "CONFIRM",
              "url": "http://www.citect.com/citectscada-batch"
            },
            {
              "name": "76937",
              "refsource": "OSVDB",
              "url": "http://www.osvdb.org/76937"
            },
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf"
            },
            {
              "name": "46779",
              "refsource": "SECUNIA",
              "url": "http://secunia.com/advisories/46779"
            },
            {
              "name": "1026306",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id?1026306"
            },
            {
              "name": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4,SCADA",
              "refsource": "CONFIRM",
              "url": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4,SCADA"
            },
            {
              "name": "46786",
              "refsource": "SECUNIA",
              "url": "http://secunia.com/advisories/46786"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2011-5163",
    "datePublished": "2012-09-15T17:00:00Z",
    "dateReserved": "2012-09-15T00:00:00Z",
    "dateUpdated": "2024-09-17T00:35:30.905Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-10981 (GCVE-0-2019-10981)

Vulnerability from nvd – Published: 2019-05-31 20:59 – Updated: 2024-08-04 22:40
VLAI?
Summary
In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials.
Severity ?
No CVSS data available.
CWE
  • CWE-522 - Insufficiently Protected Credentials CWE-522
Assigner
Impacted products
Vendor Product Version
AVEVA AVEVA Vijeo Citect and CitectSCADA Affected: Vijeo Citect 7.30 and 7.40 CitectSCADA 7.30 and 7.40
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.636Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-150-01"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityAdvisory_LFSec136.pdf"
          },
          {
            "name": "108543",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/108543"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AVEVA Vijeo Citect and CitectSCADA",
          "vendor": "AVEVA",
          "versions": [
            {
              "status": "affected",
              "version": "Vijeo Citect 7.30 and 7.40 CitectSCADA 7.30 and 7.40"
            }
          ]
        }
      ],
      "datePublic": "2019-05-21T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-522",
              "description": "Insufficiently Protected Credentials CWE-522",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-10-02T12:05:59",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-150-01"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityAdvisory_LFSec136.pdf"
        },
        {
          "name": "108543",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/108543"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2019-10981",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "AVEVA Vijeo Citect and CitectSCADA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Vijeo Citect 7.30 and 7.40 CitectSCADA 7.30 and 7.40"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "AVEVA"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Insufficiently Protected Credentials CWE-522"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-150-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-150-01"
            },
            {
              "name": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityAdvisory_LFSec136.pdf",
              "refsource": "CONFIRM",
              "url": "https://sw.aveva.com/hubfs/assets-2018/pdf/security-bulletin/SecurityAdvisory_LFSec136.pdf"
            },
            {
              "name": "108543",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/108543"
            },
            {
              "name": "https://security.cse.iitk.ac.in/responsible-disclosure",
              "refsource": "MISC",
              "url": "https://security.cse.iitk.ac.in/responsible-disclosure"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-10981",
    "datePublished": "2019-05-31T20:59:47",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.636Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-2824 (GCVE-0-2013-2824)

Vulnerability from nvd – Published: 2014-02-26 11:00 – Updated: 2024-08-06 15:52
VLAI?
Summary
Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T15:52:20.055Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.citect.schneider-electric.com/security-DoS"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-350-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2013-12-16T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2014-02-26T02:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.citect.schneider-electric.com/security-DoS"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-350-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-2824",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Schneider Electric StruxureWare SCADA Expert Vijeo Citect 7.40, Vijeo Citect 7.20 through 7.30SP1, CitectSCADA 7.20 through 7.30SP1, StruxureWare PowerSCADA Expert 7.30 through 7.30SR1, and PowerLogic SCADA 7.20 through 7.20SR1 do not properly handle exceptions, which allows remote attackers to cause a denial of service via a crafted packet."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.citect.schneider-electric.com/security-DoS",
              "refsource": "CONFIRM",
              "url": "http://www.citect.schneider-electric.com/security-DoS"
            },
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-350-01",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-350-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2013-2824",
    "datePublished": "2014-02-26T11:00:00",
    "dateReserved": "2013-04-11T00:00:00",
    "dateUpdated": "2024-08-06T15:52:20.055Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-2796 (GCVE-0-2013-2796)

Vulnerability from nvd – Published: 2013-08-09 23:00 – Updated: 2024-09-16 18:13
VLAI?
Summary
Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T15:52:21.382Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.citect.schneider-electric.com/cs-HF720SP459363"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-08-09T23:00:00Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.citect.schneider-electric.com/cs-HF720SP459363"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-2796",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.citect.schneider-electric.com/cs-HF720SP459363",
              "refsource": "CONFIRM",
              "url": "http://www.citect.schneider-electric.com/cs-HF720SP459363"
            },
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2013-2796",
    "datePublished": "2013-08-09T23:00:00Z",
    "dateReserved": "2013-04-11T00:00:00Z",
    "dateUpdated": "2024-09-16T18:13:41.217Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-3075 (GCVE-0-2013-3075)

Vulnerability from nvd – Published: 2013-04-19 10:00 – Updated: 2024-09-17 00:57
VLAI?
Summary
Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
http://www.exploit-db.com/exploits/24886/ exploitx_refsource_EXPLOIT-DB
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:00:09.518Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "24886",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "http://www.exploit-db.com/exploits/24886/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-04-19T10:00:00Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "24886",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "http://www.exploit-db.com/exploits/24886/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-3075",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "24886",
              "refsource": "EXPLOIT-DB",
              "url": "http://www.exploit-db.com/exploits/24886/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2013-3075",
    "datePublished": "2013-04-19T10:00:00Z",
    "dateReserved": "2013-04-15T00:00:00Z",
    "dateUpdated": "2024-09-17T00:57:04.612Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2011-5163 (GCVE-0-2011-5163)

Vulnerability from nvd – Published: 2012-09-15 17:00 – Updated: 2024-09-17 00:35
VLAI?
Summary
Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
http://www.citect.com/citectscada-batch x_refsource_CONFIRM
http://www.osvdb.org/76937 vdb-entryx_refsource_OSVDB
http://www.us-cert.gov/control_systems/pdf/ICSA-1… x_refsource_MISC
http://secunia.com/advisories/46779 third-party-advisoryx_refsource_SECUNIA
http://www.securitytracker.com/id?1026306 vdb-entryx_refsource_SECTRACK
https://my.mitsubishi-automation.com/downloads_sh… x_refsource_CONFIRM
http://secunia.com/advisories/46786 third-party-advisoryx_refsource_SECUNIA
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-07T00:30:46.763Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.citect.com/citectscada-batch"
          },
          {
            "name": "76937",
            "tags": [
              "vdb-entry",
              "x_refsource_OSVDB",
              "x_transferred"
            ],
            "url": "http://www.osvdb.org/76937"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf"
          },
          {
            "name": "46779",
            "tags": [
              "third-party-advisory",
              "x_refsource_SECUNIA",
              "x_transferred"
            ],
            "url": "http://secunia.com/advisories/46779"
          },
          {
            "name": "1026306",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id?1026306"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4%2CSCADA"
          },
          {
            "name": "46786",
            "tags": [
              "third-party-advisory",
              "x_refsource_SECUNIA",
              "x_transferred"
            ],
            "url": "http://secunia.com/advisories/46786"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-09-15T17:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.citect.com/citectscada-batch"
        },
        {
          "name": "76937",
          "tags": [
            "vdb-entry",
            "x_refsource_OSVDB"
          ],
          "url": "http://www.osvdb.org/76937"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf"
        },
        {
          "name": "46779",
          "tags": [
            "third-party-advisory",
            "x_refsource_SECUNIA"
          ],
          "url": "http://secunia.com/advisories/46779"
        },
        {
          "name": "1026306",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id?1026306"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4%2CSCADA"
        },
        {
          "name": "46786",
          "tags": [
            "third-party-advisory",
            "x_refsource_SECUNIA"
          ],
          "url": "http://secunia.com/advisories/46786"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2011-5163",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.citect.com/citectscada-batch",
              "refsource": "CONFIRM",
              "url": "http://www.citect.com/citectscada-batch"
            },
            {
              "name": "76937",
              "refsource": "OSVDB",
              "url": "http://www.osvdb.org/76937"
            },
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf"
            },
            {
              "name": "46779",
              "refsource": "SECUNIA",
              "url": "http://secunia.com/advisories/46779"
            },
            {
              "name": "1026306",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id?1026306"
            },
            {
              "name": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4,SCADA",
              "refsource": "CONFIRM",
              "url": "https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1\u0026doc_type=safety\u0026scat=2\u0026sstr=MX4,SCADA"
            },
            {
              "name": "46786",
              "refsource": "SECUNIA",
              "url": "http://secunia.com/advisories/46786"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2011-5163",
    "datePublished": "2012-09-15T17:00:00Z",
    "dateReserved": "2012-09-15T00:00:00Z",
    "dateUpdated": "2024-09-17T00:35:30.905Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}