CVE-2013-2796 (GCVE-0-2013-2796)

Vulnerability from cvelistv5 – Published: 2013-08-09 23:00 – Updated: 2024-09-16 18:13
VLAI?
Summary
Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T15:52:21.382Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.citect.schneider-electric.com/cs-HF720SP459363"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-08-09T23:00:00Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.citect.schneider-electric.com/cs-HF720SP459363"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-2796",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.citect.schneider-electric.com/cs-HF720SP459363",
              "refsource": "CONFIRM",
              "url": "http://www.citect.schneider-electric.com/cs-HF720SP459363"
            },
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2013-2796",
    "datePublished": "2013-08-09T23:00:00Z",
    "dateReserved": "2013-04-11T00:00:00Z",
    "dateUpdated": "2024-09-16T18:13:41.217Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:citectscada:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"7.20\", \"matchCriteriaId\": \"3F38EF72-DCCB-47DE-AF76-73A78D9F069A\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:citectscada:7.10:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E87F308E-8874-40CD-BB46-9CD955AEE26E\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:powerlogic_scada:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"7.20\", \"matchCriteriaId\": \"692487FE-D5CC-4289-8C4B-26C30C12BB08\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:powerlogic_scada:7.10:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"227FA3FF-F09B-4891-9B90-37563E1A579C\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:vijeo_citect:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"7.20\", \"matchCriteriaId\": \"261173CE-D744-4427-ABCB-AD9BA9CCCF25\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:schneider-electric:vijeo_citect:7.10:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"281F678E-1B21-4EFD-A9F6-016FCECF1DA0\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.\"}, {\"lang\": \"es\", \"value\": \"Schneider Electric Vijeo Citect v7.20 y anteriores, CitectSCADA v7.20 y anteriores, y PowerLogic SCADA v7.20 y anteriores, permite a atacantes remotos leer ficheros, enviar peticiones HTTP a servidores intranet, o causar una denegaci\\u00f3n del servicio (consumo de CPU y memoria) a trav\\u00e9s de fichero XML que contiene una declaraci\\u00f3n de entidad externa, junto con una referencia de entidad, en relaci\\u00f3n con un fallo en XML External Entity (XXE).\"}]",
      "evaluatorComment": "Per: http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02\n\n\"This vulnerability is not exploitable remotely.\"",
      "id": "CVE-2013-2796",
      "lastModified": "2024-11-21T01:52:23.007",
      "metrics": "{\"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:M/Au:N/C:C/I:C/A:C\", \"baseScore\": 6.9, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 3.4, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2013-08-09T23:55:02.537",
      "references": "[{\"url\": \"http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"US Government Resource\"]}, {\"url\": \"http://www.citect.schneider-electric.com/cs-HF720SP459363\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Patch\"]}, {\"url\": \"http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"US Government Resource\"]}, {\"url\": \"http://www.citect.schneider-electric.com/cs-HF720SP459363\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\"]}]",
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-264\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2013-2796\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2013-08-09T23:55:02.537\",\"lastModified\":\"2025-04-11T00:51:21.963\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Schneider Electric Vijeo Citect 7.20 and earlier, CitectSCADA 7.20 and earlier, and PowerLogic SCADA 7.20 and earlier allow remote attackers to read arbitrary files, send HTTP requests to intranet servers, or cause a denial of service (CPU and memory consumption) via an XML document containing an external entity declaration in conjunction with an entity reference, related to an XML External Entity (XXE) issue.\"},{\"lang\":\"es\",\"value\":\"Schneider Electric Vijeo Citect v7.20 y anteriores, CitectSCADA v7.20 y anteriores, y PowerLogic SCADA v7.20 y anteriores, permite a atacantes remotos leer ficheros, enviar peticiones HTTP a servidores intranet, o causar una denegaci\u00f3n del servicio (consumo de CPU y memoria) a trav\u00e9s de fichero XML que contiene una declaraci\u00f3n de entidad externa, junto con una referencia de entidad, en relaci\u00f3n con un fallo en XML External Entity (XXE).\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:M/Au:N/C:C/I:C/A:C\",\"baseScore\":6.9,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.4,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-264\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:citectscada:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.20\",\"matchCriteriaId\":\"3F38EF72-DCCB-47DE-AF76-73A78D9F069A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:citectscada:7.10:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E87F308E-8874-40CD-BB46-9CD955AEE26E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:powerlogic_scada:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.20\",\"matchCriteriaId\":\"692487FE-D5CC-4289-8C4B-26C30C12BB08\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:powerlogic_scada:7.10:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"227FA3FF-F09B-4891-9B90-37563E1A579C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:vijeo_citect:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"7.20\",\"matchCriteriaId\":\"261173CE-D744-4427-ABCB-AD9BA9CCCF25\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:schneider-electric:vijeo_citect:7.10:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"281F678E-1B21-4EFD-A9F6-016FCECF1DA0\"}]}]}],\"references\":[{\"url\":\"http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://www.citect.schneider-electric.com/cs-HF720SP459363\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Patch\"]},{\"url\":\"http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://www.citect.schneider-electric.com/cs-HF720SP459363\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\"]}],\"evaluatorComment\":\"Per: http://ics-cert.us-cert.gov/advisories/ICSA-13-217-02\\n\\n\\\"This vulnerability is not exploitable remotely.\\\"\"}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…