Find a vulnerability
Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
10 vulnerabilities found for command\|configure by dell
VAR-201912-1254
Vulnerability from variot - Updated: 2023-12-18 14:00Dell Command Configure versions prior to 4.2.1 contain an uncontrolled search path vulnerability. A locally authenticated malicious user could exploit this vulnerability by creating a symlink to a target file, allowing the attacker to overwrite or corrupt a specified file on the system. Dell Command Configure is an application program of Dell, which can provide configuration functions for business client platforms. The program includes a command-line interface and a graphical user interface for configuring various BIOS functions
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201912-1254",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "command\\|configure",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "4.2.1"
},
{
"model": "command configure",
"scope": "lt",
"trust": 0.8,
"vendor": "dell",
"version": "4.2.1"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013055"
},
{
"db": "NVD",
"id": "CVE-2019-18575"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:dell:command\\|configure:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.2.1",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18575"
}
]
},
"cve": "CVE-2019-18575",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.6,
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"impactScore": 9.2,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:L/AC:L/Au:N/C:N/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Local",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 6.6,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2019-18575",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:L/AC:L/Au:N/C:N/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"author": "VULHUB",
"availabilityImpact": "COMPLETE",
"baseScore": 6.6,
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "VHN-150935",
"impactScore": 9.2,
"integrityImpact": "COMPLETE",
"severity": "MEDIUM",
"trust": 0.1,
"vectorString": "AV:L/AC:L/AU:N/C:N/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 1.8,
"impactScore": 5.2,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "security_alert@emc.com",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 1.8,
"impactScore": 5.2,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.1,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2019-18575",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2019-18575",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "security_alert@emc.com",
"id": "CVE-2019-18575",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-201912-275",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULHUB",
"id": "VHN-150935",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-150935"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013055"
},
{
"db": "NVD",
"id": "CVE-2019-18575"
},
{
"db": "NVD",
"id": "CVE-2019-18575"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-275"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell Command Configure versions prior to 4.2.1 contain an uncontrolled search path vulnerability. A locally authenticated malicious user could exploit this vulnerability by creating a symlink to a target file, allowing the attacker to overwrite or corrupt a specified file on the system. Dell Command Configure is an application program of Dell, which can provide configuration functions for business client platforms. The program includes a command-line interface and a graphical user interface for configuring various BIOS functions",
"sources": [
{
"db": "NVD",
"id": "CVE-2019-18575"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013055"
},
{
"db": "VULHUB",
"id": "VHN-150935"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2019-18575",
"trust": 2.5
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013055",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-201912-275",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2020-03187",
"trust": 0.1
},
{
"db": "VULHUB",
"id": "VHN-150935",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-150935"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013055"
},
{
"db": "NVD",
"id": "CVE-2019-18575"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-275"
}
]
},
"id": "VAR-201912-1254",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-150935"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T14:00:41.349000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "DSA-2019-170",
"trust": 0.8,
"url": "https://www.dell.com/support/article/jp/ja/jpdhs1/sln319715/dsa-2019-170-dell-command-configure-dcc-uncontrolled-search-path-vulnerability?lang=en"
},
{
"title": "Dell Command Configure Fixes for code issue vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=104234"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013055"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-275"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-427",
"trust": 1.9
},
{
"problemtype": "CWE-59",
"trust": 1.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-150935"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013055"
},
{
"db": "NVD",
"id": "CVE-2019-18575"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://www.dell.com/support/article/sln319715"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2019-18575"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-18575"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-150935"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013055"
},
{
"db": "NVD",
"id": "CVE-2019-18575"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-275"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-150935"
},
{
"db": "JVNDB",
"id": "JVNDB-2019-013055"
},
{
"db": "NVD",
"id": "CVE-2019-18575"
},
{
"db": "CNNVD",
"id": "CNNVD-201912-275"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-12-06T00:00:00",
"db": "VULHUB",
"id": "VHN-150935"
},
{
"date": "2019-12-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013055"
},
{
"date": "2019-12-06T21:15:10.593000",
"db": "NVD",
"id": "CVE-2019-18575"
},
{
"date": "2019-12-06T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-275"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-10-16T00:00:00",
"db": "VULHUB",
"id": "VHN-150935"
},
{
"date": "2019-12-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2019-013055"
},
{
"date": "2020-10-16T13:33:58.557000",
"db": "NVD",
"id": "CVE-2019-18575"
},
{
"date": "2020-06-10T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201912-275"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201912-275"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell Command Configure Vulnerabilities in uncontrolled search path elements",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2019-013055"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "code problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201912-275"
}
],
"trust": 0.6
}
}
VAR-202301-1585
Vulnerability from variot - Updated: 2023-12-18 13:59Dell command configuration, version 4.8 and prior, contains improper folder permission when installed not to default path but to non-secured path which leads to privilege escalation. This is critical severity vulnerability as it allows non-admin to modify the files inside installed directory and able to make application unavailable for all users. Dell command configuration Exists in a vulnerability related to the leakage of resources to the wrong area.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202301-1585",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "command\\|configure",
"scope": "lt",
"trust": 1.0,
"vendor": "dell",
"version": "4.9.0"
},
{
"model": "dell command configure",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": null
},
{
"model": "dell command configure",
"scope": "lte",
"trust": 0.8,
"vendor": "\u30c7\u30eb",
"version": "4.8 and earlier"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-006134"
},
{
"db": "NVD",
"id": "CVE-2022-34457"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:dell:command\\|configure:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.9.0",
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-34457"
}
]
},
"cve": "CVE-2022-34457",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "security_alert@emc.com",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.3,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-34457",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-34457",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "security_alert@emc.com",
"id": "CVE-2022-34457",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202301-1447",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-006134"
},
{
"db": "NVD",
"id": "CVE-2022-34457"
},
{
"db": "NVD",
"id": "CVE-2022-34457"
},
{
"db": "CNNVD",
"id": "CNNVD-202301-1447"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "\nDell command configuration, version 4.8 and prior, contains improper folder permission when installed not to default path but to non-secured path which leads to privilege escalation. This is critical severity vulnerability as it allows non-admin to modify the files inside installed directory and able to make application unavailable for all users. Dell command configuration Exists in a vulnerability related to the leakage of resources to the wrong area.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-34457"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-006134"
},
{
"db": "VULHUB",
"id": "VHN-426773"
},
{
"db": "VULMON",
"id": "CVE-2022-34457"
}
],
"trust": 1.8
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-34457",
"trust": 3.4
},
{
"db": "JVNDB",
"id": "JVNDB-2022-006134",
"trust": 0.8
},
{
"db": "CNNVD",
"id": "CNNVD-202301-1447",
"trust": 0.6
},
{
"db": "VULHUB",
"id": "VHN-426773",
"trust": 0.1
},
{
"db": "VULMON",
"id": "CVE-2022-34457",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426773"
},
{
"db": "VULMON",
"id": "CVE-2022-34457"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-006134"
},
{
"db": "NVD",
"id": "CVE-2022-34457"
},
{
"db": "CNNVD",
"id": "CNNVD-202301-1447"
}
]
},
"id": "VAR-202301-1585",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VULHUB",
"id": "VHN-426773"
}
],
"trust": 0.01
},
"last_update_date": "2023-12-18T13:59:19.849000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "DSA-2022-297",
"trust": 0.8,
"url": "https://www.dell.com/support/kbdoc/ja-jp/000205633/dsa-2022-297-dell-command-configure-security-update-for-multiple-vulnerabilities"
},
{
"title": "Dell Command Configure Security vulnerabilities",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=222577"
},
{
"title": "",
"trust": 0.1,
"url": "https://github.com/live-hack-cve/cve-2022-34457 "
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2022-34457"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-006134"
},
{
"db": "CNNVD",
"id": "CNNVD-202301-1447"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-732",
"trust": 1.0
},
{
"problemtype": "Leakage of resources to the wrong area (CWE-668) [NVD evaluation ]",
"trust": 0.8
},
{
"problemtype": "CWE-668",
"trust": 0.1
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426773"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-006134"
},
{
"db": "NVD",
"id": "CVE-2022-34457"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://www.dell.com/support/kbdoc/000205633"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-34457"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-34457/"
},
{
"trust": 0.1,
"url": "https://github.com/live-hack-cve/cve-2022-34457"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULHUB",
"id": "VHN-426773"
},
{
"db": "VULMON",
"id": "CVE-2022-34457"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-006134"
},
{
"db": "NVD",
"id": "CVE-2022-34457"
},
{
"db": "CNNVD",
"id": "CNNVD-202301-1447"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULHUB",
"id": "VHN-426773"
},
{
"db": "VULMON",
"id": "CVE-2022-34457"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-006134"
},
{
"db": "NVD",
"id": "CVE-2022-34457"
},
{
"db": "CNNVD",
"id": "CNNVD-202301-1447"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-01-18T00:00:00",
"db": "VULHUB",
"id": "VHN-426773"
},
{
"date": "2023-01-18T00:00:00",
"db": "VULMON",
"id": "CVE-2022-34457"
},
{
"date": "2023-07-03T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-006134"
},
{
"date": "2023-01-18T12:15:10.587000",
"db": "NVD",
"id": "CVE-2022-34457"
},
{
"date": "2023-01-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202301-1447"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-01-26T00:00:00",
"db": "VULHUB",
"id": "VHN-426773"
},
{
"date": "2023-01-18T00:00:00",
"db": "VULMON",
"id": "CVE-2022-34457"
},
{
"date": "2023-07-03T00:59:00",
"db": "JVNDB",
"id": "JVNDB-2022-006134"
},
{
"date": "2023-11-07T03:48:42.833000",
"db": "NVD",
"id": "CVE-2022-34457"
},
{
"date": "2023-07-24T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202301-1447"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "local",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202301-1447"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Dell\u00a0command\u00a0configuration\u00a0 Vulnerability in leaking resources to the wrong area in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-006134"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "other",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202301-1447"
}
],
"trust": 0.6
}
}
CVE-2023-44289 (GCVE-0-2023-44289)
Vulnerability from nvd – Published: 2023-11-23 06:41 – Updated: 2025-06-05 14:11- CWE-284 - Improper Access Control
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00021862… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Dell Command Configure (DCC) |
Affected:
Versions prior to 4.11.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:59:51.990Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000218628/dsa-2023-390-security-update-for-dell-command-configure-and-dell-command-monitor-vulnerabilities"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-44289",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-05T14:11:26.521729Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-05T14:11:38.414Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Dell Command | Configure"
],
"product": "Dell Command Configure (DCC)",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 4.11.0"
}
]
}
],
"datePublic": "2023-11-21T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell Command | Configure versions prior to 4.11.0, contain an improper access control vulnerability. A local malicious standard user could potentially exploit this vulnerability while repairing/changing installation, leading to privilege escalation.\u003c/span\u003e\n\n"
}
],
"value": "\nDell Command | Configure versions prior to 4.11.0, contain an improper access control vulnerability. A local malicious standard user could potentially exploit this vulnerability while repairing/changing installation, leading to privilege escalation.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-23T06:41:33.931Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000218628/dsa-2023-390-security-update-for-dell-command-configure-and-dell-command-monitor-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-44289",
"datePublished": "2023-11-23T06:41:33.931Z",
"dateReserved": "2023-09-28T09:32:10.185Z",
"dateUpdated": "2025-06-05T14:11:38.414Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-43086 (GCVE-0-2023-43086)
Vulnerability from nvd – Published: 2023-11-23 06:27 – Updated: 2024-08-02 19:37- CWE-284 - Improper Access Control
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00021842… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Dell Command Configure (DCC) |
Affected:
Versions prior to 4.11.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:37:23.064Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000218424/dsa-2023-387-security-update-for-a-dell-command-configure-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Dell Command Configure (DCC)",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 4.11.0"
}
]
}
],
"datePublic": "2023-11-21T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell Command | Configure, versions prior to 4.11.0, contains an improper access control vulnerability. A local malicious user could potentially modify files inside installation folder during application upgrade, leading to privilege escalation.\u003c/span\u003e\n\n"
}
],
"value": "\nDell Command | Configure, versions prior to 4.11.0, contains an improper access control vulnerability. A local malicious user could potentially modify files inside installation folder during application upgrade, leading to privilege escalation.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-23T06:27:19.920Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000218424/dsa-2023-387-security-update-for-a-dell-command-configure-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-43086",
"datePublished": "2023-11-23T06:27:19.920Z",
"dateReserved": "2023-09-15T07:03:52.366Z",
"dateUpdated": "2024-08-02T19:37:23.064Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-34457 (GCVE-0-2022-34457)
Vulnerability from nvd – Published: 2023-01-18 11:38 – Updated: 2025-04-03 18:05- CWE-284 - Improper Access Control
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/000205633 | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Dell Command Configure (DCC) |
Affected:
0 , ≤ 4.8
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:15:15.293Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000205633"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-34457",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-02T16:11:57.320060Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-03T18:05:33.209Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Dell Command Configure (DCC)",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "4.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-11-22T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cdiv\u003e\u003cdiv\u003eDell command configuration, version 4.8 and prior, contains improper folder permission when installed not to default path but to non-secured path which leads to privilege escalation. This is critical severity vulnerability as it allows non-admin to modify the files inside installed directory and able to make application unavailable for all users.\u003c/div\u003e\u003c/div\u003e\n\n"
}
],
"value": "\nDell command configuration, version 4.8 and prior, contains improper folder permission when installed not to default path but to non-secured path which leads to privilege escalation. This is critical severity vulnerability as it allows non-admin to modify the files inside installed directory and able to make application unavailable for all users.\n\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-18T11:38:57.154Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/000205633"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2022-34457",
"datePublished": "2023-01-18T11:38:57.154Z",
"dateReserved": "2022-06-23T18:55:17.136Z",
"dateUpdated": "2025-04-03T18:05:33.209Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-18575 (GCVE-0-2019-18575)
Vulnerability from nvd – Published: 2019-12-06 20:40 – Updated: 2024-09-17 01:25- CWE-427 - Uncontrolled Search Path Element
| URL | Tags |
|---|---|
| https://www.dell.com/support/article/SLN319715 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Dell Command Configure (DCC) |
Affected:
unspecified , < 4.2.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T01:54:14.488Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/article/SLN319715"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Dell Command Configure (DCC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.2.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-12-05T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Dell Command Configure versions prior to 4.2.1 contain an uncontrolled search path vulnerability. A locally authenticated malicious user could exploit this vulnerability by creating a symlink to a target file, allowing the attacker to overwrite or corrupt a specified file on the system."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427: Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-12-06T20:40:13.000Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/article/SLN319715"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2019-12-05",
"ID": "CVE-2019-18575",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Dell Command Configure (DCC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.2.1"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell Command Configure versions prior to 4.2.1 contain an uncontrolled search path vulnerability. A locally authenticated malicious user could exploit this vulnerability by creating a symlink to a target file, allowing the attacker to overwrite or corrupt a specified file on the system."
}
]
},
"impact": {
"cvss": {
"baseScore": 7.1,
"baseSeverity": "High",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-427: Uncontrolled Search Path Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/article/SLN319715",
"refsource": "MISC",
"url": "https://www.dell.com/support/article/SLN319715"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2019-18575",
"datePublished": "2019-12-06T20:40:13.655Z",
"dateReserved": "2019-10-29T00:00:00.000Z",
"dateUpdated": "2024-09-17T01:25:33.000Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-44289 (GCVE-0-2023-44289)
Vulnerability from cvelistv5 – Published: 2023-11-23 06:41 – Updated: 2025-06-05 14:11- CWE-284 - Improper Access Control
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00021862… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Dell Command Configure (DCC) |
Affected:
Versions prior to 4.11.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:59:51.990Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000218628/dsa-2023-390-security-update-for-dell-command-configure-and-dell-command-monitor-vulnerabilities"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-44289",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-05T14:11:26.521729Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-05T14:11:38.414Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Dell Command | Configure"
],
"product": "Dell Command Configure (DCC)",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 4.11.0"
}
]
}
],
"datePublic": "2023-11-21T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell Command | Configure versions prior to 4.11.0, contain an improper access control vulnerability. A local malicious standard user could potentially exploit this vulnerability while repairing/changing installation, leading to privilege escalation.\u003c/span\u003e\n\n"
}
],
"value": "\nDell Command | Configure versions prior to 4.11.0, contain an improper access control vulnerability. A local malicious standard user could potentially exploit this vulnerability while repairing/changing installation, leading to privilege escalation.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-23T06:41:33.931Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000218628/dsa-2023-390-security-update-for-dell-command-configure-and-dell-command-monitor-vulnerabilities"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-44289",
"datePublished": "2023-11-23T06:41:33.931Z",
"dateReserved": "2023-09-28T09:32:10.185Z",
"dateUpdated": "2025-06-05T14:11:38.414Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-43086 (GCVE-0-2023-43086)
Vulnerability from cvelistv5 – Published: 2023-11-23 06:27 – Updated: 2024-08-02 19:37- CWE-284 - Improper Access Control
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00021842… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Dell Command Configure (DCC) |
Affected:
Versions prior to 4.11.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T19:37:23.064Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000218424/dsa-2023-387-security-update-for-a-dell-command-configure-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Dell Command Configure (DCC)",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "Versions prior to 4.11.0"
}
]
}
],
"datePublic": "2023-11-21T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell Command | Configure, versions prior to 4.11.0, contains an improper access control vulnerability. A local malicious user could potentially modify files inside installation folder during application upgrade, leading to privilege escalation.\u003c/span\u003e\n\n"
}
],
"value": "\nDell Command | Configure, versions prior to 4.11.0, contains an improper access control vulnerability. A local malicious user could potentially modify files inside installation folder during application upgrade, leading to privilege escalation.\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-23T06:27:19.920Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000218424/dsa-2023-387-security-update-for-a-dell-command-configure-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2023-43086",
"datePublished": "2023-11-23T06:27:19.920Z",
"dateReserved": "2023-09-15T07:03:52.366Z",
"dateUpdated": "2024-08-02T19:37:23.064Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-34457 (GCVE-0-2022-34457)
Vulnerability from cvelistv5 – Published: 2023-01-18 11:38 – Updated: 2025-04-03 18:05- CWE-284 - Improper Access Control
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/000205633 | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Dell Command Configure (DCC) |
Affected:
0 , ≤ 4.8
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:15:15.293Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000205633"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-34457",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-02T16:11:57.320060Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-03T18:05:33.209Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Dell Command Configure (DCC)",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "4.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-11-22T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cdiv\u003e\u003cdiv\u003eDell command configuration, version 4.8 and prior, contains improper folder permission when installed not to default path but to non-secured path which leads to privilege escalation. This is critical severity vulnerability as it allows non-admin to modify the files inside installed directory and able to make application unavailable for all users.\u003c/div\u003e\u003c/div\u003e\n\n"
}
],
"value": "\nDell command configuration, version 4.8 and prior, contains improper folder permission when installed not to default path but to non-secured path which leads to privilege escalation. This is critical severity vulnerability as it allows non-admin to modify the files inside installed directory and able to make application unavailable for all users.\n\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-18T11:38:57.154Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/000205633"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2022-34457",
"datePublished": "2023-01-18T11:38:57.154Z",
"dateReserved": "2022-06-23T18:55:17.136Z",
"dateUpdated": "2025-04-03T18:05:33.209Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-18575 (GCVE-0-2019-18575)
Vulnerability from cvelistv5 – Published: 2019-12-06 20:40 – Updated: 2024-09-17 01:25- CWE-427 - Uncontrolled Search Path Element
| URL | Tags |
|---|---|
| https://www.dell.com/support/article/SLN319715 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Dell Command Configure (DCC) |
Affected:
unspecified , < 4.2.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T01:54:14.488Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/article/SLN319715"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Dell Command Configure (DCC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.2.1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-12-05T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Dell Command Configure versions prior to 4.2.1 contain an uncontrolled search path vulnerability. A locally authenticated malicious user could exploit this vulnerability by creating a symlink to a target file, allowing the attacker to overwrite or corrupt a specified file on the system."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427: Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-12-06T20:40:13.000Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/article/SLN319715"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2019-12-05",
"ID": "CVE-2019-18575",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Dell Command Configure (DCC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.2.1"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell Command Configure versions prior to 4.2.1 contain an uncontrolled search path vulnerability. A locally authenticated malicious user could exploit this vulnerability by creating a symlink to a target file, allowing the attacker to overwrite or corrupt a specified file on the system."
}
]
},
"impact": {
"cvss": {
"baseScore": 7.1,
"baseSeverity": "High",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-427: Uncontrolled Search Path Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/article/SLN319715",
"refsource": "MISC",
"url": "https://www.dell.com/support/article/SLN319715"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2019-18575",
"datePublished": "2019-12-06T20:40:13.655Z",
"dateReserved": "2019-10-29T00:00:00.000Z",
"dateUpdated": "2024-09-17T01:25:33.000Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}