9 vulnerabilities found for di-7100g_c1_firmware by dlink

FKIE_CVE-2025-11339

Vulnerability from fkie_nvd - Published: 2025-10-06 17:16 - Updated: 2025-11-19 21:47
Summary
A vulnerability has been found in D-Link DI-7100G C1 up to 20250928. This issue affects the function sub_4BD4F8 of the file /webchat/hi_block.asp of the component jhttpd. The manipulation of the argument popupId leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Impacted products
Vendor Product Version
dlink di-7100g_c1_firmware 2025-09-28
dlink di-7100g_c1 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:di-7100g_c1_firmware:2025-09-28:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A967144-1055-4FC2-97F7-8E486F6D6D53",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:di-7100g_c1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B661C392-F07F-4BF5-B559-B00693C63E94",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been found in D-Link DI-7100G C1 up to 20250928. This issue affects the function sub_4BD4F8 of the file /webchat/hi_block.asp of the component jhttpd. The manipulation of the argument popupId leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
    }
  ],
  "id": "CVE-2025-11339",
  "lastModified": "2025-11-19T21:47:37.660",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "cna@vuldb.com",
        "type": "Secondary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "cna@vuldb.com",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.4,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "PROOF_OF_CONCEPT",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "cna@vuldb.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-10-06T17:16:04.683",
  "references": [
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?ctiid.327222"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?id.327222"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?submit.664635"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Product"
      ],
      "url": "https://www.dlink.com/"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required"
      ],
      "url": "https://www.yuque.com/jh0ng/vmpda6/zr11zfssl8h74bn3"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required"
      ],
      "url": "https://www.yuque.com/jh0ng/vmpda6/zr11zfssl8h74bn3#Wjajr"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        },
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ],
      "source": "cna@vuldb.com",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2025-11338

Vulnerability from fkie_nvd - Published: 2025-10-06 16:15 - Updated: 2025-11-19 21:48
Summary
A flaw has been found in D-Link DI-7100G C1 up to 20250928. This vulnerability affects the function sub_4C0990 of the file /webchat/login.cgi of the component jhttpd. Executing manipulation of the argument openid can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used.
Impacted products
Vendor Product Version
dlink di-7100g_c1_firmware 2025-09-28
dlink di-7100g_c1 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:di-7100g_c1_firmware:2025-09-28:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A967144-1055-4FC2-97F7-8E486F6D6D53",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:di-7100g_c1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B661C392-F07F-4BF5-B559-B00693C63E94",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A flaw has been found in D-Link DI-7100G C1 up to 20250928. This vulnerability affects the function sub_4C0990 of the file /webchat/login.cgi of the component jhttpd. Executing manipulation of the argument openid can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used."
    }
  ],
  "id": "CVE-2025-11338",
  "lastModified": "2025-11-19T21:48:49.203",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 9.0,
          "confidentialityImpact": "COMPLETE",
          "integrityImpact": "COMPLETE",
          "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 8.0,
        "impactScore": 10.0,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "cna@vuldb.com",
        "type": "Secondary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.8,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 7.4,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "PROOF_OF_CONCEPT",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "LOW",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "HIGH",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "cna@vuldb.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-10-06T16:15:33.497",
  "references": [
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?ctiid.327221"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?id.327221"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?submit.664619"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Product"
      ],
      "url": "https://www.dlink.com/"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required"
      ],
      "url": "https://www.yuque.com/jh0ng/vmpda6/kggo2ngrcphzvwml"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        },
        {
          "lang": "en",
          "value": "CWE-120"
        }
      ],
      "source": "cna@vuldb.com",
      "type": "Primary"
    }
  ]
}

FKIE_CVE-2025-11335

Vulnerability from fkie_nvd - Published: 2025-10-06 13:15 - Updated: 2025-11-19 21:48
Summary
A weakness has been identified in D-Link DI-7100G C1 up to 20250928. Affected by this vulnerability is the function sub_46409C of the file /msp_info.htm?flag=qos of the component jhttpd. This manipulation of the argument iface causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be exploited.
Impacted products
Vendor Product Version
dlink di-7100g_c1_firmware 2025-09-28
dlink di-7100g_c1 -

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:di-7100g_c1_firmware:2025-09-28:*:*:*:*:*:*:*",
              "matchCriteriaId": "7A967144-1055-4FC2-97F7-8E486F6D6D53",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:di-7100g_c1:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B661C392-F07F-4BF5-B559-B00693C63E94",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A weakness has been identified in D-Link DI-7100G C1 up to 20250928. Affected by this vulnerability is the function sub_46409C of the file /msp_info.htm?flag=qos of the component jhttpd. This manipulation of the argument iface causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be exploited."
    }
  ],
  "id": "CVE-2025-11335",
  "lastModified": "2025-11-19T21:48:27.153",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "MULTIPLE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 5.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 6.4,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "cna@vuldb.com",
        "type": "Secondary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 4.7,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 3.4,
        "source": "cna@vuldb.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.2,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.2,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 5.1,
          "baseSeverity": "MEDIUM",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "PROOF_OF_CONCEPT",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "HIGH",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "LOW",
          "vulnConfidentialityImpact": "LOW",
          "vulnIntegrityImpact": "LOW",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "cna@vuldb.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-10-06T13:15:33.100",
  "references": [
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?ctiid.327218"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?id.327218"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Third Party Advisory",
        "VDB Entry"
      ],
      "url": "https://vuldb.com/?submit.664597"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Product"
      ],
      "url": "https://www.dlink.com/"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required"
      ],
      "url": "https://www.yuque.com/jh0ng/vmpda6/fpqlhpkb0orgseav"
    },
    {
      "source": "cna@vuldb.com",
      "tags": [
        "Permissions Required"
      ],
      "url": "https://www.yuque.com/jh0ng/vmpda6/fpqlhpkb0orgseav#DOhrV"
    }
  ],
  "sourceIdentifier": "cna@vuldb.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-74"
        },
        {
          "lang": "en",
          "value": "CWE-77"
        }
      ],
      "source": "cna@vuldb.com",
      "type": "Primary"
    }
  ]
}

CVE-2025-11339 (GCVE-0-2025-11339)

Vulnerability from cvelistv5 – Published: 2025-10-06 16:32 – Updated: 2025-10-06 17:16
VLAI?
Summary
A vulnerability has been found in D-Link DI-7100G C1 up to 20250928. This issue affects the function sub_4BD4F8 of the file /webchat/hi_block.asp of the component jhttpd. The manipulation of the argument popupId leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
D-Link DI-7100G C1 Affected: 20250928
Create a notification for this product.
Credits
sheratan (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11339",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-06T17:00:37.173521Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-06T17:16:06.762Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "jhttpd"
          ],
          "product": "DI-7100G C1",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20250928"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "sheratan (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in D-Link DI-7100G C1 up to 20250928. This issue affects the function sub_4BD4F8 of the file /webchat/hi_block.asp of the component jhttpd. The manipulation of the argument popupId leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "In D-Link DI-7100G C1 up to 20250928 wurde eine Schwachstelle gefunden. Es betrifft die Funktion sub_4BD4F8 der Datei /webchat/hi_block.asp der Komponente jhttpd. Dank der Manipulation des Arguments popupId mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann remote ausgef\u00fchrt werden. Die Schwachstelle wurde \u00f6ffentlich offengelegt und k\u00f6nnte ausgenutzt werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-06T16:32:09.380Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-327222 | D-Link DI-7100G C1 jhttpd hi_block.asp sub_4BD4F8 buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.327222"
        },
        {
          "name": "VDB-327222 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.327222"
        },
        {
          "name": "Submit #664635 | D-Link DI-7100G C1 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.664635"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://www.yuque.com/jh0ng/vmpda6/zr11zfssl8h74bn3"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://www.yuque.com/jh0ng/vmpda6/zr11zfssl8h74bn3#Wjajr"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.dlink.com/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-10-05T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-10-06T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-10-06T17:33:32.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "D-Link DI-7100G C1 jhttpd hi_block.asp sub_4BD4F8 buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-11339",
    "datePublished": "2025-10-06T16:32:09.380Z",
    "dateReserved": "2025-10-05T22:09:06.624Z",
    "dateUpdated": "2025-10-06T17:16:06.762Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-11338 (GCVE-0-2025-11338)

Vulnerability from cvelistv5 – Published: 2025-10-06 16:02 – Updated: 2025-10-06 17:16
VLAI?
Summary
A flaw has been found in D-Link DI-7100G C1 up to 20250928. This vulnerability affects the function sub_4C0990 of the file /webchat/login.cgi of the component jhttpd. Executing manipulation of the argument openid can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used.
CWE
Assigner
References
Impacted products
Vendor Product Version
D-Link DI-7100G C1 Affected: 20250928
Create a notification for this product.
Credits
sheratan (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11338",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-06T17:01:59.929368Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-06T17:16:48.402Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "jhttpd"
          ],
          "product": "DI-7100G C1",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20250928"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "sheratan (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw has been found in D-Link DI-7100G C1 up to 20250928. This vulnerability affects the function sub_4C0990 of the file /webchat/login.cgi of the component jhttpd. Executing manipulation of the argument openid can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in D-Link DI-7100G C1 up to 20250928 entdeckt. Betroffen davon ist die Funktion sub_4C0990 der Datei /webchat/login.cgi der Komponente jhttpd. Die Bearbeitung des Arguments openid verursacht buffer overflow. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit wurde der \u00d6ffentlichkeit bekannt gemacht und k\u00f6nnte verwendet werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-06T16:02:08.398Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-327221 | D-Link DI-7100G C1 jhttpd login.cgi sub_4C0990 buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.327221"
        },
        {
          "name": "VDB-327221 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.327221"
        },
        {
          "name": "Submit #664619 | D-Link DI-7100G C1 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.664619"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://www.yuque.com/jh0ng/vmpda6/kggo2ngrcphzvwml"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.dlink.com/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-10-05T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-10-06T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-10-06T17:34:24.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "D-Link DI-7100G C1 jhttpd login.cgi sub_4C0990 buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-11338",
    "datePublished": "2025-10-06T16:02:08.398Z",
    "dateReserved": "2025-10-05T22:09:03.609Z",
    "dateUpdated": "2025-10-06T17:16:48.402Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-11335 (GCVE-0-2025-11335)

Vulnerability from cvelistv5 – Published: 2025-10-06 12:32 – Updated: 2025-10-06 20:01
VLAI?
Summary
A weakness has been identified in D-Link DI-7100G C1 up to 20250928. Affected by this vulnerability is the function sub_46409C of the file /msp_info.htm?flag=qos of the component jhttpd. This manipulation of the argument iface causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be exploited.
CWE
Assigner
Impacted products
Vendor Product Version
D-Link DI-7100G C1 Affected: 20250928
Create a notification for this product.
Credits
sheratan (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11335",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-06T20:00:52.220100Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-06T20:01:00.911Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "jhttpd"
          ],
          "product": "DI-7100G C1",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20250928"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "sheratan (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A weakness has been identified in D-Link DI-7100G C1 up to 20250928. Affected by this vulnerability is the function sub_46409C of the file /msp_info.htm?flag=qos of the component jhttpd. This manipulation of the argument iface causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be exploited."
        },
        {
          "lang": "de",
          "value": "In D-Link DI-7100G C1 up to 20250928 wurde eine Schwachstelle gefunden. Hierbei geht es um die Funktion sub_46409C der Datei /msp_info.htm?flag=qos der Komponente jhttpd. Durch Beeinflussen des Arguments iface mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit ist \u00f6ffentlich verf\u00fcgbar und k\u00f6nnte genutzt werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5.8,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-06T12:32:09.515Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-327218 | D-Link DI-7100G C1 jhttpd msp_info.htm sub_46409C command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.327218"
        },
        {
          "name": "VDB-327218 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.327218"
        },
        {
          "name": "Submit #664597 | D-Link DI-7100G C1 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.664597"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://www.yuque.com/jh0ng/vmpda6/fpqlhpkb0orgseav"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://www.yuque.com/jh0ng/vmpda6/fpqlhpkb0orgseav#DOhrV"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.dlink.com/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-10-05T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-10-05T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-10-06T14:31:07.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "D-Link DI-7100G C1 jhttpd msp_info.htm sub_46409C command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-11335",
    "datePublished": "2025-10-06T12:32:09.515Z",
    "dateReserved": "2025-10-05T15:42:21.663Z",
    "dateUpdated": "2025-10-06T20:01:00.911Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-11339 (GCVE-0-2025-11339)

Vulnerability from nvd – Published: 2025-10-06 16:32 – Updated: 2025-10-06 17:16
VLAI?
Summary
A vulnerability has been found in D-Link DI-7100G C1 up to 20250928. This issue affects the function sub_4BD4F8 of the file /webchat/hi_block.asp of the component jhttpd. The manipulation of the argument popupId leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CWE
Assigner
Impacted products
Vendor Product Version
D-Link DI-7100G C1 Affected: 20250928
Create a notification for this product.
Credits
sheratan (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11339",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-06T17:00:37.173521Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-06T17:16:06.762Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "jhttpd"
          ],
          "product": "DI-7100G C1",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20250928"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "sheratan (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been found in D-Link DI-7100G C1 up to 20250928. This issue affects the function sub_4BD4F8 of the file /webchat/hi_block.asp of the component jhttpd. The manipulation of the argument popupId leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used."
        },
        {
          "lang": "de",
          "value": "In D-Link DI-7100G C1 up to 20250928 wurde eine Schwachstelle gefunden. Es betrifft die Funktion sub_4BD4F8 der Datei /webchat/hi_block.asp der Komponente jhttpd. Dank der Manipulation des Arguments popupId mit unbekannten Daten kann eine buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann remote ausgef\u00fchrt werden. Die Schwachstelle wurde \u00f6ffentlich offengelegt und k\u00f6nnte ausgenutzt werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-06T16:32:09.380Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-327222 | D-Link DI-7100G C1 jhttpd hi_block.asp sub_4BD4F8 buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.327222"
        },
        {
          "name": "VDB-327222 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.327222"
        },
        {
          "name": "Submit #664635 | D-Link DI-7100G C1 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.664635"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://www.yuque.com/jh0ng/vmpda6/zr11zfssl8h74bn3"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://www.yuque.com/jh0ng/vmpda6/zr11zfssl8h74bn3#Wjajr"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.dlink.com/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-10-05T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-10-06T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-10-06T17:33:32.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "D-Link DI-7100G C1 jhttpd hi_block.asp sub_4BD4F8 buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-11339",
    "datePublished": "2025-10-06T16:32:09.380Z",
    "dateReserved": "2025-10-05T22:09:06.624Z",
    "dateUpdated": "2025-10-06T17:16:06.762Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-11338 (GCVE-0-2025-11338)

Vulnerability from nvd – Published: 2025-10-06 16:02 – Updated: 2025-10-06 17:16
VLAI?
Summary
A flaw has been found in D-Link DI-7100G C1 up to 20250928. This vulnerability affects the function sub_4C0990 of the file /webchat/login.cgi of the component jhttpd. Executing manipulation of the argument openid can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used.
CWE
Assigner
References
Impacted products
Vendor Product Version
D-Link DI-7100G C1 Affected: 20250928
Create a notification for this product.
Credits
sheratan (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11338",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-06T17:01:59.929368Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-06T17:16:48.402Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "jhttpd"
          ],
          "product": "DI-7100G C1",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20250928"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "sheratan (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A flaw has been found in D-Link DI-7100G C1 up to 20250928. This vulnerability affects the function sub_4C0990 of the file /webchat/login.cgi of the component jhttpd. Executing manipulation of the argument openid can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used."
        },
        {
          "lang": "de",
          "value": "Es wurde eine Schwachstelle in D-Link DI-7100G C1 up to 20250928 entdeckt. Betroffen davon ist die Funktion sub_4C0990 der Datei /webchat/login.cgi der Komponente jhttpd. Die Bearbeitung des Arguments openid verursacht buffer overflow. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit wurde der \u00d6ffentlichkeit bekannt gemacht und k\u00f6nnte verwendet werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 9,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "Memory Corruption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-06T16:02:08.398Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-327221 | D-Link DI-7100G C1 jhttpd login.cgi sub_4C0990 buffer overflow",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.327221"
        },
        {
          "name": "VDB-327221 | CTI Indicators (IOB, IOC, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.327221"
        },
        {
          "name": "Submit #664619 | D-Link DI-7100G C1 Buffer Overflow",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.664619"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://www.yuque.com/jh0ng/vmpda6/kggo2ngrcphzvwml"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.dlink.com/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-10-05T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-10-06T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-10-06T17:34:24.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "D-Link DI-7100G C1 jhttpd login.cgi sub_4C0990 buffer overflow"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-11338",
    "datePublished": "2025-10-06T16:02:08.398Z",
    "dateReserved": "2025-10-05T22:09:03.609Z",
    "dateUpdated": "2025-10-06T17:16:48.402Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-11335 (GCVE-0-2025-11335)

Vulnerability from nvd – Published: 2025-10-06 12:32 – Updated: 2025-10-06 20:01
VLAI?
Summary
A weakness has been identified in D-Link DI-7100G C1 up to 20250928. Affected by this vulnerability is the function sub_46409C of the file /msp_info.htm?flag=qos of the component jhttpd. This manipulation of the argument iface causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be exploited.
CWE
Assigner
Impacted products
Vendor Product Version
D-Link DI-7100G C1 Affected: 20250928
Create a notification for this product.
Credits
sheratan (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11335",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-06T20:00:52.220100Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-06T20:01:00.911Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "jhttpd"
          ],
          "product": "DI-7100G C1",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "20250928"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "sheratan (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A weakness has been identified in D-Link DI-7100G C1 up to 20250928. Affected by this vulnerability is the function sub_46409C of the file /msp_info.htm?flag=qos of the component jhttpd. This manipulation of the argument iface causes command injection. The attack is possible to be carried out remotely. The exploit has been made available to the public and could be exploited."
        },
        {
          "lang": "de",
          "value": "In D-Link DI-7100G C1 up to 20250928 wurde eine Schwachstelle gefunden. Hierbei geht es um die Funktion sub_46409C der Datei /msp_info.htm?flag=qos der Komponente jhttpd. Durch Beeinflussen des Arguments iface mit unbekannten Daten kann eine command injection-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit ist \u00f6ffentlich verf\u00fcgbar und k\u00f6nnte genutzt werden."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 4.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5.8,
            "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "Command Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-74",
              "description": "Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-06T12:32:09.515Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-327218 | D-Link DI-7100G C1 jhttpd msp_info.htm sub_46409C command injection",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.327218"
        },
        {
          "name": "VDB-327218 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.327218"
        },
        {
          "name": "Submit #664597 | D-Link DI-7100G C1 Command Injection",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.664597"
        },
        {
          "tags": [
            "related"
          ],
          "url": "https://www.yuque.com/jh0ng/vmpda6/fpqlhpkb0orgseav"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://www.yuque.com/jh0ng/vmpda6/fpqlhpkb0orgseav#DOhrV"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.dlink.com/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-10-05T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-10-05T02:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-10-06T14:31:07.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "D-Link DI-7100G C1 jhttpd msp_info.htm sub_46409C command injection"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-11335",
    "datePublished": "2025-10-06T12:32:09.515Z",
    "dateReserved": "2025-10-05T15:42:21.663Z",
    "dateUpdated": "2025-10-06T20:01:00.911Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}