Search criteria

5 vulnerabilities found for dir-803_firmware by dlink

CVE-2025-14528 (GCVE-0-2025-14528)

Vulnerability from nvd – Published: 2025-12-11 17:02 – Updated: 2025-12-11 19:36 Unsupported When Assigned
VLAI?
Title
D-Link DIR-803 Configuration getcfg.php information disclosure
Summary
A vulnerability was detected in D-Link DIR-803 up to 1.04. Impacted is an unknown function of the file /getcfg.php of the component Configuration Handler. The manipulation of the argument AUTHORIZED_GROUP results in information disclosure. The attack may be performed from remote. The exploit is now public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
CWE
Assigner
Impacted products
Vendor Product Version
D-Link DIR-803 Affected: 1.04
Create a notification for this product.
Credits
jiahui2888 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-14528",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-11T19:19:47.874510Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-11T19:36:04.774Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/D-Link/vuln-2/DIR-803%20Authentication%20Bypass.md#poc"
          },
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/D-Link/vuln-2/DIR-803%20Authentication%20Bypass.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Configuration Handler"
          ],
          "product": "DIR-803",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "1.04"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "jiahui2888 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was detected in D-Link DIR-803 up to 1.04. Impacted is an unknown function of the file /getcfg.php of the component Configuration Handler. The manipulation of the argument AUTHORIZED_GROUP results in information disclosure. The attack may be performed from remote. The exploit is now public and may be used. This vulnerability only affects products that are no longer supported by the maintainer."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N/E:POC/RL:W/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "Information Disclosure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "Improper Access Controls",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-11T17:02:15.495Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-335869 | D-Link DIR-803 Configuration getcfg.php information disclosure",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.335869"
        },
        {
          "name": "VDB-335869 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.335869"
        },
        {
          "name": "Submit #703150 | D-Link DIR-803 1.04 and earlier Authorization Bypass",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.703150"
        },
        {
          "tags": [
            "broken-link"
          ],
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/D-Link/vuln-2/DIR-803%20Authentication%20Bypass.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/D-Link/vuln-2/DIR-803%20Authentication%20Bypass.md#poc"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.dlink.com/"
        }
      ],
      "tags": [
        "unsupported-when-assigned"
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-12-11T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-12-11T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-12-11T09:45:15.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "D-Link DIR-803 Configuration getcfg.php information disclosure"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-14528",
    "datePublished": "2025-12-11T17:02:15.495Z",
    "dateReserved": "2025-12-11T08:40:04.683Z",
    "dateUpdated": "2025-12-11T19:36:04.774Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2020-25786 (GCVE-0-2020-25786)

Vulnerability from nvd – Published: 2020-09-19 19:24 – Updated: 2024-08-04 15:40 Unsupported When Assigned
VLAI?
Summary
webinc/js/info.php on D-Link DIR-816L 2.06.B09_BETA and DIR-803 1.04.B02 devices allows XSS via the HTTP Referer header. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: this is typically not exploitable because of URL encoding (except in Internet Explorer) and because a web page cannot specify that a client should make an additional HTTP request with an arbitrary Referer header
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T15:40:36.997Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10190"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/sek1th/iot/blob/master/DIR-816L_XSS.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "webinc/js/info.php on D-Link DIR-816L 2.06.B09_BETA and DIR-803 1.04.B02 devices allows XSS via the HTTP Referer header. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: this is typically not exploitable because of URL encoding (except in Internet Explorer) and because a web page cannot specify that a client should make an additional HTTP request with an arbitrary Referer header"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-09-19T19:24:09",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10190"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/sek1th/iot/blob/master/DIR-816L_XSS.md"
        }
      ],
      "tags": [
        "unsupported-when-assigned"
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-25786",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "** UNSUPPORTED WHEN ASSIGNED ** webinc/js/info.php on D-Link DIR-816L 2.06.B09_BETA and DIR-803 1.04.B02 devices allows XSS via the HTTP Referer header. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: this is typically not exploitable because of URL encoding (except in Internet Explorer) and because a web page cannot specify that a client should make an additional HTTP request with an arbitrary Referer header."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10190",
              "refsource": "MISC",
              "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10190"
            },
            {
              "name": "https://github.com/sek1th/iot/blob/master/DIR-816L_XSS.md",
              "refsource": "MISC",
              "url": "https://github.com/sek1th/iot/blob/master/DIR-816L_XSS.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-25786",
    "datePublished": "2020-09-19T19:24:09",
    "dateReserved": "2020-09-19T00:00:00",
    "dateUpdated": "2024-08-04T15:40:36.997Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-14528 (GCVE-0-2025-14528)

Vulnerability from cvelistv5 – Published: 2025-12-11 17:02 – Updated: 2025-12-11 19:36 Unsupported When Assigned
VLAI?
Title
D-Link DIR-803 Configuration getcfg.php information disclosure
Summary
A vulnerability was detected in D-Link DIR-803 up to 1.04. Impacted is an unknown function of the file /getcfg.php of the component Configuration Handler. The manipulation of the argument AUTHORIZED_GROUP results in information disclosure. The attack may be performed from remote. The exploit is now public and may be used. This vulnerability only affects products that are no longer supported by the maintainer.
CWE
Assigner
Impacted products
Vendor Product Version
D-Link DIR-803 Affected: 1.04
Create a notification for this product.
Credits
jiahui2888 (VulDB User)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-14528",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-12-11T19:19:47.874510Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-12-11T19:36:04.774Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/D-Link/vuln-2/DIR-803%20Authentication%20Bypass.md#poc"
          },
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/D-Link/vuln-2/DIR-803%20Authentication%20Bypass.md"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "modules": [
            "Configuration Handler"
          ],
          "product": "DIR-803",
          "vendor": "D-Link",
          "versions": [
            {
              "status": "affected",
              "version": "1.04"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "jiahui2888 (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was detected in D-Link DIR-803 up to 1.04. Impacted is an unknown function of the file /getcfg.php of the component Configuration Handler. The manipulation of the argument AUTHORIZED_GROUP results in information disclosure. The attack may be performed from remote. The exploit is now public and may be used. This vulnerability only affects products that are no longer supported by the maintainer."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:W/RC:R",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N/E:POC/RL:W/RC:UR",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "Information Disclosure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "Improper Access Controls",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-11T17:02:15.495Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-335869 | D-Link DIR-803 Configuration getcfg.php information disclosure",
          "tags": [
            "vdb-entry",
            "technical-description"
          ],
          "url": "https://vuldb.com/?id.335869"
        },
        {
          "name": "VDB-335869 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.335869"
        },
        {
          "name": "Submit #703150 | D-Link DIR-803 1.04 and earlier Authorization Bypass",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.703150"
        },
        {
          "tags": [
            "broken-link"
          ],
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/D-Link/vuln-2/DIR-803%20Authentication%20Bypass.md"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/Madgeaaaaa/MY_VULN_2/blob/main/D-Link/vuln-2/DIR-803%20Authentication%20Bypass.md#poc"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.dlink.com/"
        }
      ],
      "tags": [
        "unsupported-when-assigned"
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-12-11T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2025-12-11T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2025-12-11T09:45:15.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "D-Link DIR-803 Configuration getcfg.php information disclosure"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2025-14528",
    "datePublished": "2025-12-11T17:02:15.495Z",
    "dateReserved": "2025-12-11T08:40:04.683Z",
    "dateUpdated": "2025-12-11T19:36:04.774Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2020-25786 (GCVE-0-2020-25786)

Vulnerability from cvelistv5 – Published: 2020-09-19 19:24 – Updated: 2024-08-04 15:40 Unsupported When Assigned
VLAI?
Summary
webinc/js/info.php on D-Link DIR-816L 2.06.B09_BETA and DIR-803 1.04.B02 devices allows XSS via the HTTP Referer header. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: this is typically not exploitable because of URL encoding (except in Internet Explorer) and because a web page cannot specify that a client should make an additional HTTP request with an arbitrary Referer header
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T15:40:36.997Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10190"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/sek1th/iot/blob/master/DIR-816L_XSS.md"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "webinc/js/info.php on D-Link DIR-816L 2.06.B09_BETA and DIR-803 1.04.B02 devices allows XSS via the HTTP Referer header. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: this is typically not exploitable because of URL encoding (except in Internet Explorer) and because a web page cannot specify that a client should make an additional HTTP request with an arbitrary Referer header"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-09-19T19:24:09",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10190"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/sek1th/iot/blob/master/DIR-816L_XSS.md"
        }
      ],
      "tags": [
        "unsupported-when-assigned"
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-25786",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "** UNSUPPORTED WHEN ASSIGNED ** webinc/js/info.php on D-Link DIR-816L 2.06.B09_BETA and DIR-803 1.04.B02 devices allows XSS via the HTTP Referer header. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: this is typically not exploitable because of URL encoding (except in Internet Explorer) and because a web page cannot specify that a client should make an additional HTTP request with an arbitrary Referer header."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10190",
              "refsource": "MISC",
              "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10190"
            },
            {
              "name": "https://github.com/sek1th/iot/blob/master/DIR-816L_XSS.md",
              "refsource": "MISC",
              "url": "https://github.com/sek1th/iot/blob/master/DIR-816L_XSS.md"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-25786",
    "datePublished": "2020-09-19T19:24:09",
    "dateReserved": "2020-09-19T00:00:00",
    "dateUpdated": "2024-08-04T15:40:36.997Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

FKIE_CVE-2020-25786

Vulnerability from fkie_nvd - Published: 2020-09-19 20:15 - Updated: 2024-11-21 05:18
Summary
webinc/js/info.php on D-Link DIR-816L 2.06.B09_BETA and DIR-803 1.04.B02 devices allows XSS via the HTTP Referer header. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: this is typically not exploitable because of URL encoding (except in Internet Explorer) and because a web page cannot specify that a client should make an additional HTTP request with an arbitrary Referer header

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-803_firmware:1.04.b02:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C475766-ADDE-4461-9FDF-FE6332F95DBE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-803:a1:*:*:*:*:*:*:*",
              "matchCriteriaId": "1B033D96-30EC-44EA-B70E-670CEAA0E79F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-816l_firmware:2.06:*:*:*:*:*:*:*",
              "matchCriteriaId": "1817EE29-D782-4A98-A478-20BDA559C5CE",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:dlink:dir-816l_firmware:2.06.b09:beta:*:*:*:*:*:*",
              "matchCriteriaId": "ABE7E66F-20B2-4A39-A845-03E5FBBD9E2A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-816l:b1:*:*:*:*:*:*:*",
              "matchCriteriaId": "637B2D4B-0EA7-4E30-9B2B-77484D701042",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-645_firmware:1.06b01:*:*:*:*:*:*:*",
              "matchCriteriaId": "84706BD1-5AC0-449D-AB20-A81A9A2D4077",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-645:a1:*:*:*:*:*:*:*",
              "matchCriteriaId": "E02F7E04-F6D7-466D-81AD-14591443EBC3",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-815_firmware:2.07.b01:*:*:*:*:*:*:*",
              "matchCriteriaId": "F38F5A85-E7DC-4ACF-A488-11AC00DE5856",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-815:b1:*:*:*:*:*:*:*",
              "matchCriteriaId": "AA95C491-7895-4410-A9D2-3C7BD2BEB0DC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-860l_firmware:1.10b04:*:*:*:*:*:*:*",
              "matchCriteriaId": "D84E9E39-D9A6-4370-8D84-6CAE2D02CDFD",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-860l:a1:*:*:*:*:*:*:*",
              "matchCriteriaId": "C0FB3DE6-9F8D-485A-8DF3-76FC6C20CB6C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:dlink:dir-865l_firmware:1.08b01:*:*:*:*:*:*:*",
              "matchCriteriaId": "608124DE-D143-4E95-9DE8-D7A35586361E",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:dlink:dir-865l:a1:*:*:*:*:*:*:*",
              "matchCriteriaId": "DEC7270B-453D-4D04-90AB-7EBD6DC3D97B",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [
    {
      "sourceIdentifier": "cve@mitre.org",
      "tags": [
        "unsupported-when-assigned"
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "webinc/js/info.php on D-Link DIR-816L 2.06.B09_BETA and DIR-803 1.04.B02 devices allows XSS via the HTTP Referer header. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. NOTE: this is typically not exploitable because of URL encoding (except in Internet Explorer) and because a web page cannot specify that a client should make an additional HTTP request with an arbitrary Referer header"
    },
    {
      "lang": "es",
      "value": "** NO COMPATIBLE CUANDO SE ASIGN\u00d3 ** El archivo webinc/js/info.php en dispositivos D-Link DIR-816L versi\u00f3n 2.06.B09_BETA y DIR-803 versi\u00f3n 1.04.B02, permite un ataque de tipo XSS por medio del encabezado HTTP Referer.\u0026#xa0;NOTA: Esta vulnerabilidad solo afecta a los productos que ya no son compatibles con el mantenedor.\u0026#xa0;NOTA: esto t\u00edpicamente no es explotable debido a la codificaci\u00f3n de URL (excepto en Internet Explorer) y porque una p\u00e1gina web no puede especificar que un cliente debe realizar una petici\u00f3n HTTP adicional con un encabezado Referer arbitrario"
    }
  ],
  "id": "CVE-2020-25786",
  "lastModified": "2024-11-21T05:18:46.167",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "NONE",
          "baseScore": 4.3,
          "confidentialityImpact": "NONE",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 2.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 6.1,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "LOW",
          "privilegesRequired": "NONE",
          "scope": "CHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 2.7,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2020-09-19T20:15:11.903",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/sek1th/iot/blob/master/DIR-816L_XSS.md"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10190"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Exploit",
        "Third Party Advisory"
      ],
      "url": "https://github.com/sek1th/iot/blob/master/DIR-816L_XSS.md"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://supportannouncement.us.dlink.com/announcement/publication.aspx?name=SAP10190"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-79"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}