All the vulnerabilites related to Softing - edgeConnector
cve-2022-2337
Vulnerability from cvelistv5
Published
2022-08-17 20:18
Modified
2024-08-03 00:32
Severity ?
EPSS score ?
Summary
Softing Secure Integration Server NULL Pointer Dereference
References
▼ | URL | Tags |
---|---|---|
https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html | x_refsource_CONFIRM | |
https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04 | x_refsource_CONFIRM |
Impacted products
▼ | Vendor | Product |
---|---|---|
Softing | Secure Integration Server |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T00:32:09.697Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Secure Integration Server", "vendor": "Softing", "versions": [ { "status": "affected", "version": "V1.22" } ] } ], "credits": [ { "lang": "en", "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA." } ], "descriptions": [ { "lang": "en", "value": "A crafted HTTP packet with a missing HTTP URI can create a denial-of-service condition in Softing Secure Integration Server V1.22." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "CWE-476: NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-17T20:18:49", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" } ], "solutions": [ { "lang": "en", "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-4 on the Softing security website." } ], "source": { "discovery": "EXTERNAL" }, "title": "Softing Secure Integration Server NULL Pointer Dereference", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2022-2337", "STATE": "PUBLIC", "TITLE": "Softing Secure Integration Server NULL Pointer Dereference" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Secure Integration Server", "version": { "version_data": [ { "version_affected": "=", "version_value": "V1.22" } ] } } ] }, "vendor_name": "Softing" } ] } }, "credit": [ { "lang": "eng", "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A crafted HTTP packet with a missing HTTP URI can create a denial-of-service condition in Softing Secure Integration Server V1.22." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-476: NULL Pointer Dereference" } ] } ] }, "references": { "reference_data": [ { "name": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html", "refsource": "CONFIRM", "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html" }, { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04", "refsource": "CONFIRM", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" } ] }, "solution": [ { "lang": "en", "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-4 on the Softing security website." } ], "source": { "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2022-2337", "datePublished": "2022-08-17T20:18:49", "dateReserved": "2022-07-06T00:00:00", "dateUpdated": "2024-08-03T00:32:09.697Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-1748
Vulnerability from cvelistv5
Published
2022-08-17 20:08
Modified
2024-08-03 00:16
Severity ?
EPSS score ?
Summary
Softing Secure Integration Server NULL Pointer Dereference
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04 | x_refsource_CONFIRM | |
https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-7.html | x_refsource_CONFIRM |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T00:16:59.941Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-7.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Secure Integration Server", "vendor": "Softing", "versions": [ { "status": "affected", "version": "V1.22" } ] }, { "product": "OPC UA C++ SDK", "vendor": "Softing", "versions": [ { "status": "affected", "version": "V6.00" } ] }, { "product": "edgeConnector Siemens", "vendor": "Softing", "versions": [ { "status": "affected", "version": "V3.10" } ] }, { "product": "edgeConnector 840D", "vendor": "Softing", "versions": [ { "status": "affected", "version": "V3.10" } ] }, { "product": "edgeConnector Modbus", "vendor": "Softing", "versions": [ { "status": "affected", "version": "V3.10" } ] }, { "product": "edgeAggregator", "vendor": "Softing", "versions": [ { "status": "affected", "version": "V3.10" } ] } ], "credits": [ { "lang": "en", "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA." } ], "descriptions": [ { "lang": "en", "value": "Softing OPC UA C++ Server SDK, Secure Integration Server, edgeConnector, edgeAggregator, OPC Suite, and uaGate are affected by a NULL pointer dereference vulnerability." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "CWE-476: NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-17T20:08:38", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-7.html" } ], "solutions": [ { "lang": "en", "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-7 on the Softing security website." } ], "source": { "discovery": "EXTERNAL" }, "title": "Softing Secure Integration Server NULL Pointer Dereference", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2022-1748", "STATE": "PUBLIC", "TITLE": "Softing Secure Integration Server NULL Pointer Dereference" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Secure Integration Server", "version": { "version_data": [ { "version_affected": "=", "version_value": "V1.22" } ] } }, { "product_name": "OPC UA C++ SDK", "version": { "version_data": [ { "version_affected": "=", "version_value": "V6.00" } ] } }, { "product_name": "edgeConnector Siemens", "version": { "version_data": [ { "version_affected": "=", "version_value": "V3.10" } ] } }, { "product_name": "edgeConnector 840D", "version": { "version_data": [ { "version_affected": "=", "version_value": "V3.10" } ] } }, { "product_name": "edgeConnector Modbus", "version": { "version_data": [ { "version_affected": "=", "version_value": "V3.10" } ] } }, { "product_name": "edgeAggregator", "version": { "version_data": [ { "version_affected": "=", "version_value": "V3.10" } ] } } ] }, "vendor_name": "Softing" } ] } }, "credit": [ { "lang": "eng", "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Softing OPC UA C++ Server SDK, Secure Integration Server, edgeConnector, edgeAggregator, OPC Suite, and uaGate are affected by a NULL pointer dereference vulnerability." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-476: NULL Pointer Dereference" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04", "refsource": "CONFIRM", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" }, { "name": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-7.html", "refsource": "CONFIRM", "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-7.html" } ] }, "solution": [ { "lang": "en", "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-7 on the Softing security website." } ], "source": { "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2022-1748", "datePublished": "2022-08-17T20:08:38", "dateReserved": "2022-05-16T00:00:00", "dateUpdated": "2024-08-03T00:16:59.941Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-2336
Vulnerability from cvelistv5
Published
2022-08-17 20:07
Modified
2024-08-03 00:32
Severity ?
EPSS score ?
Summary
Softing Secure Integration Server Improper Authentication
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04 | x_refsource_CONFIRM | |
https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-6.html | x_refsource_CONFIRM |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T00:32:09.614Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-6.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Secure Integration Server", "vendor": "Softing", "versions": [ { "status": "affected", "version": "V1.22" } ] }, { "product": "edgeConnector Siemens", "vendor": "Softing", "versions": [ { "status": "affected", "version": "V3.10" } ] }, { "product": "edgeConnector 840D", "vendor": "Softing", "versions": [ { "status": "affected", "version": "V3.10" } ] }, { "product": "edgeConnector Modbus", "vendor": "Softing", "versions": [ { "status": "affected", "version": "V3.10" } ] }, { "product": "edgeAggregator", "vendor": "Softing", "versions": [ { "status": "affected", "version": "V3.10" } ] } ], "credits": [ { "lang": "en", "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA." } ], "descriptions": [ { "lang": "en", "value": "Softing Secure Integration Server, edgeConnector, and edgeAggregator software ships with the default administrator credentials as `admin` and password as `admin`. This allows Softing to log in to the server directly to perform administrative functions. Upon installation or upon first login, the application does not ask the user to change the `admin` password. There is no warning or prompt to ask the user to change the default password, and to change the password, many steps are required." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-287", "description": "CWE-287: Improper Authentication", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-17T20:07:46", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-6.html" } ], "solutions": [ { "lang": "en", "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-6 on the Softing security website." } ], "source": { "discovery": "EXTERNAL" }, "title": "Softing Secure Integration Server Improper Authentication", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2022-2336", "STATE": "PUBLIC", "TITLE": "Softing Secure Integration Server Improper Authentication" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Secure Integration Server", "version": { "version_data": [ { "version_affected": "=", "version_value": "V1.22" } ] } }, { "product_name": "edgeConnector Siemens", "version": { "version_data": [ { "version_affected": "=", "version_value": "V3.10" } ] } }, { "product_name": "edgeConnector 840D", "version": { "version_data": [ { "version_affected": "=", "version_value": "V3.10" } ] } }, { "product_name": "edgeConnector Modbus", "version": { "version_data": [ { "version_affected": "=", "version_value": "V3.10" } ] } }, { "product_name": "edgeAggregator", "version": { "version_data": [ { "version_affected": "=", "version_value": "V3.10" } ] } } ] }, "vendor_name": "Softing" } ] } }, "credit": [ { "lang": "eng", "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Softing Secure Integration Server, edgeConnector, and edgeAggregator software ships with the default administrator credentials as `admin` and password as `admin`. This allows Softing to log in to the server directly to perform administrative functions. Upon installation or upon first login, the application does not ask the user to change the `admin` password. There is no warning or prompt to ask the user to change the default password, and to change the password, many steps are required." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-287: Improper Authentication" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04", "refsource": "CONFIRM", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" }, { "name": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-6.html", "refsource": "CONFIRM", "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-6.html" } ] }, "solution": [ { "lang": "en", "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-6 on the Softing security website." } ], "source": { "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2022-2336", "datePublished": "2022-08-17T20:07:46", "dateReserved": "2022-07-06T00:00:00", "dateUpdated": "2024-08-03T00:32:09.614Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-1373
Vulnerability from cvelistv5
Published
2022-08-17 20:10
Modified
2024-08-03 00:03
Severity ?
EPSS score ?
Summary
Softing Secure Integration Server Relative Path Traversal
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04 | x_refsource_CONFIRM | |
https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-5.html | x_refsource_CONFIRM |
Impacted products
▼ | Vendor | Product |
---|---|---|
Softing | Secure Integration Server |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T00:03:05.938Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-5.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Secure Integration Server", "vendor": "Softing", "versions": [ { "status": "affected", "version": "V1.22" } ] } ], "credits": [ { "lang": "en", "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA." } ], "descriptions": [ { "lang": "en", "value": "The \u201crestore configuration\u201d feature of Softing Secure Integration Server V1.22 is vulnerable to a directory traversal vulnerability when processing zip files. An attacker can craft a zip file to load an arbitrary dll and execute code. Using the \"restore configuration\" feature to upload a zip file containing a path traversal file may cause a file to be created and executed upon touching the disk." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-23", "description": "CWE-23: Relative Path Traversal", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-17T20:10:24", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-5.html" } ], "solutions": [ { "lang": "en", "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-5 on the Softing security website." } ], "source": { "discovery": "EXTERNAL" }, "title": "Softing Secure Integration Server Relative Path Traversal", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2022-1373", "STATE": "PUBLIC", "TITLE": "Softing Secure Integration Server Relative Path Traversal" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Secure Integration Server", "version": { "version_data": [ { "version_affected": "=", "version_value": "V1.22" } ] } } ] }, "vendor_name": "Softing" } ] } }, "credit": [ { "lang": "eng", "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The \u201crestore configuration\u201d feature of Softing Secure Integration Server V1.22 is vulnerable to a directory traversal vulnerability when processing zip files. An attacker can craft a zip file to load an arbitrary dll and execute code. Using the \"restore configuration\" feature to upload a zip file containing a path traversal file may cause a file to be created and executed upon touching the disk." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-23: Relative Path Traversal" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04", "refsource": "CONFIRM", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" }, { "name": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-5.html", "refsource": "CONFIRM", "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-5.html" } ] }, "solution": [ { "lang": "en", "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-5 on the Softing security website." } ], "source": { "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2022-1373", "datePublished": "2022-08-17T20:10:24", "dateReserved": "2022-04-14T00:00:00", "dateUpdated": "2024-08-03T00:03:05.938Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-37453
Vulnerability from cvelistv5
Published
2022-10-20 00:00
Modified
2024-08-03 10:29
Severity ?
EPSS score ?
Summary
An issue was discovered in Softing OPC UA C++ SDK before 6.10. A buffer overflow or an excess allocation happens due to unchecked array and matrix bounds in structure data types.
References
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T10:29:21.061Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://softing.com" }, { "tags": [ "x_transferred" ], "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-9.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Softing OPC UA C++ SDK before 6.10. A buffer overflow or an excess allocation happens due to unchecked array and matrix bounds in structure data types." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-10-20T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://softing.com" }, { "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-9.html" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-37453", "datePublished": "2022-10-20T00:00:00", "dateReserved": "2022-08-07T00:00:00", "dateUpdated": "2024-08-03T10:29:21.061Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2021-40873
Vulnerability from cvelistv5
Published
2021-11-10 22:48
Modified
2024-08-04 02:51
Severity ?
EPSS score ?
Summary
An issue was discovered in Softing Industrial Automation OPC UA C++ SDK before 5.66, and uaToolkit Embedded before 1.40. Remote attackers to cause a denial of service (DoS) by sending crafted messages to a client or server. The server process may crash unexpectedly because of a double free, and must be restarted.
References
▼ | URL | Tags |
---|---|---|
https://industrial.softing.com/ | x_refsource_MISC | |
https://industrial.softing.com/fileadmin/sof-files/pdf/ia/support/Security_Bulletin_CVE-2021-40873.pdf | x_refsource_MISC |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T02:51:07.755Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://industrial.softing.com/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://industrial.softing.com/fileadmin/sof-files/pdf/ia/support/Security_Bulletin_CVE-2021-40873.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Softing Industrial Automation OPC UA C++ SDK before 5.66, and uaToolkit Embedded before 1.40. Remote attackers to cause a denial of service (DoS) by sending crafted messages to a client or server. The server process may crash unexpectedly because of a double free, and must be restarted." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-11-10T22:48:27", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://industrial.softing.com/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://industrial.softing.com/fileadmin/sof-files/pdf/ia/support/Security_Bulletin_CVE-2021-40873.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-40873", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered in Softing Industrial Automation OPC UA C++ SDK before 5.66, and uaToolkit Embedded before 1.40. Remote attackers to cause a denial of service (DoS) by sending crafted messages to a client or server. The server process may crash unexpectedly because of a double free, and must be restarted." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://industrial.softing.com/", "refsource": "MISC", "url": "https://industrial.softing.com/" }, { "name": "https://industrial.softing.com/fileadmin/sof-files/pdf/ia/support/Security_Bulletin_CVE-2021-40873.pdf", "refsource": "MISC", "url": "https://industrial.softing.com/fileadmin/sof-files/pdf/ia/support/Security_Bulletin_CVE-2021-40873.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-40873", "datePublished": "2021-11-10T22:48:27", "dateReserved": "2021-09-13T00:00:00", "dateUpdated": "2024-08-04T02:51:07.755Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-2334
Vulnerability from cvelistv5
Published
2022-08-17 20:11
Modified
2024-08-03 00:32
Severity ?
EPSS score ?
Summary
Softing Secure Integration Server Uncontrolled Search Path Element
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04 | x_refsource_CONFIRM | |
https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-5.html | x_refsource_CONFIRM |
Impacted products
▼ | Vendor | Product |
---|---|---|
Softing | Secure Integration Server |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T00:32:09.402Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-5.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Secure Integration Server", "vendor": "Softing", "versions": [ { "status": "affected", "version": "V1.22" } ] } ], "credits": [ { "lang": "en", "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA." } ], "descriptions": [ { "lang": "en", "value": "The application searches for a library dll that is not found. If an attacker can place a dll with this name, then the attacker can leverage it to execute arbitrary code on the targeted Softing Secure Integration Server V1.22." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-427", "description": "CWE-427: Uncontrolled Search Path Element", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-17T20:11:17", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-5.html" } ], "solutions": [ { "lang": "en", "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-5 on the Softing security website." } ], "source": { "discovery": "EXTERNAL" }, "title": "Softing Secure Integration Server Uncontrolled Search Path Element", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2022-2334", "STATE": "PUBLIC", "TITLE": "Softing Secure Integration Server Uncontrolled Search Path Element" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Secure Integration Server", "version": { "version_data": [ { "version_affected": "=", "version_value": "V1.22" } ] } } ] }, "vendor_name": "Softing" } ] } }, "credit": [ { "lang": "eng", "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The application searches for a library dll that is not found. If an attacker can place a dll with this name, then the attacker can leverage it to execute arbitrary code on the targeted Softing Secure Integration Server V1.22." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.2, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-427: Uncontrolled Search Path Element" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04", "refsource": "CONFIRM", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" }, { "name": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-5.html", "refsource": "CONFIRM", "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-5.html" } ] }, "solution": [ { "lang": "en", "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-5 on the Softing security website." } ], "source": { "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2022-2334", "datePublished": "2022-08-17T20:11:17", "dateReserved": "2022-07-06T00:00:00", "dateUpdated": "2024-08-03T00:32:09.402Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-2338
Vulnerability from cvelistv5
Published
2022-08-17 20:15
Modified
2024-08-03 00:32
Severity ?
EPSS score ?
Summary
Softing Secure Integration Server Cleartext Transmission of Sensitive Information
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04 | x_refsource_CONFIRM | |
https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-5.html | x_refsource_CONFIRM |
Impacted products
▼ | Vendor | Product |
---|---|---|
Softing | Secure Integration Server |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T00:32:09.605Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-5.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Secure Integration Server", "vendor": "Softing", "versions": [ { "status": "affected", "version": "V1.22" } ] } ], "credits": [ { "lang": "en", "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA." } ], "descriptions": [ { "lang": "en", "value": "Softing Secure Integration Server V1.22 is vulnerable to authentication bypass via a machine-in-the-middle attack. The default the administration interface is accessible via plaintext HTTP protocol, facilitating the attack. The HTTP request may contain the session cookie in the request, which may be captured for use in authenticating to the server." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 5.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-319", "description": "CWE-319: Cleartext Transmission of Sensitive Information", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-17T20:15:03", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-5.html" } ], "solutions": [ { "lang": "en", "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-5 on the Softing security website." } ], "source": { "discovery": "EXTERNAL" }, "title": "Softing Secure Integration Server Cleartext Transmission of Sensitive Information", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2022-2338", "STATE": "PUBLIC", "TITLE": "Softing Secure Integration Server Cleartext Transmission of Sensitive Information" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Secure Integration Server", "version": { "version_data": [ { "version_affected": "=", "version_value": "V1.22" } ] } } ] }, "vendor_name": "Softing" } ] } }, "credit": [ { "lang": "eng", "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Softing Secure Integration Server V1.22 is vulnerable to authentication bypass via a machine-in-the-middle attack. The default the administration interface is accessible via plaintext HTTP protocol, facilitating the attack. The HTTP request may contain the session cookie in the request, which may be captured for use in authenticating to the server." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "NONE", "baseScore": 5.7, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-319: Cleartext Transmission of Sensitive Information" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04", "refsource": "CONFIRM", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" }, { "name": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-5.html", "refsource": "CONFIRM", "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-5.html" } ] }, "solution": [ { "lang": "en", "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-5 on the Softing security website." } ], "source": { "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2022-2338", "datePublished": "2022-08-17T20:15:03", "dateReserved": "2022-07-06T00:00:00", "dateUpdated": "2024-08-03T00:32:09.605Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-0860
Vulnerability from cvelistv5
Published
2024-03-14 20:54
Modified
2024-08-12 20:30
Severity ?
EPSS score ?
Summary
Cleartext Transmission of Sensitive Information in Softing edgeConnector and edgeAggregator
References
▼ | URL | Tags |
---|---|---|
https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-13 | government-resource |
Impacted products
▼ | Vendor | Product |
---|---|---|
Softing | edgeConnector | |
Softing | edgeAggregator |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T18:18:18.751Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "government-resource", "x_transferred" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-13" } ], "title": "CVE Program Container" }, { "affected": [ { "cpes": [ "cpe:2.3:a:softing:edgeconnector:3.60:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "edgeconnector", "vendor": "softing", "versions": [ { "status": "affected", "version": "3.60" } ] }, { "cpes": [ "cpe:2.3:a:softing:edgeaggregator:3.60:*:*:*:*:*:*:*" ], "defaultStatus": "unaffected", "product": "edgeaggregator", "vendor": "softing", "versions": [ { "status": "affected", "version": "3.60" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-0860", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-03-15T16:34:23.355296Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-08-12T20:30:17.682Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "edgeConnector", "vendor": "Softing", "versions": [ { "status": "affected", "version": "Version 3.60" } ] }, { "defaultStatus": "unaffected", "product": "edgeAggregator", "vendor": "Softing", "versions": [ { "status": "affected", "version": "Version 3.60" } ] } ], "credits": [ { "lang": "en", "type": "finder", "value": "Pan ZhenPeng (@Peterpan0927) and Li JianTao (@CurseRed) of STAR Labs SG Pte. Ltd. (@starlabs_sg) working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA. Claroty Team82 working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cp\u003eThe affected product is vulnerable to a cleartext transmission of sensitive information vulnerability, which may allow an attacker to capture packets to craft their own requests.\u003c/p\u003e\u003cbr\u003e\n\n" } ], "value": "\nThe affected product is vulnerable to a cleartext transmission of sensitive information vulnerability, which may allow an attacker to capture packets to craft their own requests.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "availabilityImpact": "HIGH", "baseScore": 8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-319", "description": "CWE-319 Cleartext Transmission of Sensitive Information", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-03-14T20:54:56.710Z", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "government-resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-13" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpdate Softing edgeConnector and edgeAggregator to v3.70 or greater.\u003c/span\u003e\u003cbr\u003e" } ], "value": "\nUpdate Softing edgeConnector and edgeAggregator to v3.70 or greater.\n" } ], "source": { "discovery": "UNKNOWN" }, "title": "Cleartext Transmission of Sensitive Information in Softing edgeConnector and edgeAggregator", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2024-0860", "datePublished": "2024-03-14T20:54:56.710Z", "dateReserved": "2024-01-24T15:13:18.203Z", "dateUpdated": "2024-08-12T20:30:17.682Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-2547
Vulnerability from cvelistv5
Published
2022-08-17 20:06
Modified
2024-08-03 00:39
Severity ?
EPSS score ?
Summary
Softing Secure Integration Server NULL Pointer Dereference
References
▼ | URL | Tags |
---|---|---|
https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html | x_refsource_CONFIRM | |
https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04 | x_refsource_CONFIRM |
Impacted products
▼ | Vendor | Product |
---|---|---|
Softing | Secure Integration Server |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T00:39:08.031Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Secure Integration Server", "vendor": "Softing", "versions": [ { "status": "affected", "version": "V1.22" } ] } ], "credits": [ { "lang": "en", "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA." } ], "descriptions": [ { "lang": "en", "value": "A crafted HTTP packet without a content-type header can create a denial-of-service condition in Softing Secure Integration Server V1.22." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-476", "description": "CWE-476: NULL Pointer Dereference", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-17T20:06:38", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" } ], "solutions": [ { "lang": "en", "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-4 on the Softing security website." } ], "source": { "discovery": "EXTERNAL" }, "title": "Softing Secure Integration Server NULL Pointer Dereference", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2022-2547", "STATE": "PUBLIC", "TITLE": "Softing Secure Integration Server NULL Pointer Dereference" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Secure Integration Server", "version": { "version_data": [ { "version_affected": "=", "version_value": "V1.22" } ] } } ] }, "vendor_name": "Softing" } ] } }, "credit": [ { "lang": "eng", "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A crafted HTTP packet without a content-type header can create a denial-of-service condition in Softing Secure Integration Server V1.22." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-476: NULL Pointer Dereference" } ] } ] }, "references": { "reference_data": [ { "name": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html", "refsource": "CONFIRM", "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html" }, { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04", "refsource": "CONFIRM", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" } ] }, "solution": [ { "lang": "en", "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-4 on the Softing security website." } ], "source": { "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2022-2547", "datePublished": "2022-08-17T20:06:38", "dateReserved": "2022-07-26T00:00:00", "dateUpdated": "2024-08-03T00:39:08.031Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-2335
Vulnerability from cvelistv5
Published
2022-08-17 20:13
Modified
2024-08-03 00:32
Severity ?
EPSS score ?
Summary
Softing Secure Integration Server Integer Underflow
References
▼ | URL | Tags |
---|---|---|
https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html | x_refsource_CONFIRM | |
https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04 | x_refsource_CONFIRM |
Impacted products
▼ | Vendor | Product |
---|---|---|
Softing | Secure Integration Server |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T00:32:09.693Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Secure Integration Server", "vendor": "Softing", "versions": [ { "status": "affected", "version": "V1.22" } ] } ], "credits": [ { "lang": "en", "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA." } ], "descriptions": [ { "lang": "en", "value": "A crafted HTTP packet with a -1 content-length header can create a denial-of-service condition in Softing Secure Integration Server V1.22." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-191", "description": "CWE-191: Integer Underflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-17T20:13:15", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" } ], "solutions": [ { "lang": "en", "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-4 on the Softing security website." } ], "source": { "discovery": "EXTERNAL" }, "title": "Softing Secure Integration Server Integer Underflow", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2022-2335", "STATE": "PUBLIC", "TITLE": "Softing Secure Integration Server Integer Underflow" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Secure Integration Server", "version": { "version_data": [ { "version_affected": "=", "version_value": "V1.22" } ] } } ] }, "vendor_name": "Softing" } ] } }, "credit": [ { "lang": "eng", "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A crafted HTTP packet with a -1 content-length header can create a denial-of-service condition in Softing Secure Integration Server V1.22." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-191: Integer Underflow" } ] } ] }, "references": { "reference_data": [ { "name": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html", "refsource": "CONFIRM", "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html" }, { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04", "refsource": "CONFIRM", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" } ] }, "solution": [ { "lang": "en", "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-4 on the Softing security website." } ], "source": { "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2022-2335", "datePublished": "2022-08-17T20:13:15", "dateReserved": "2022-07-06T00:00:00", "dateUpdated": "2024-08-03T00:32:09.693Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-1069
Vulnerability from cvelistv5
Published
2022-08-17 20:17
Modified
2024-08-02 23:47
Severity ?
EPSS score ?
Summary
Softing Secure Integration Server Out-of-bounds Read
References
▼ | URL | Tags |
---|---|---|
https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html | x_refsource_CONFIRM | |
https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04 | x_refsource_CONFIRM |
Impacted products
▼ | Vendor | Product |
---|---|---|
Softing | Secure Integration Server |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T23:47:43.266Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Secure Integration Server", "vendor": "Softing", "versions": [ { "status": "affected", "version": "V1.22" } ] } ], "credits": [ { "lang": "en", "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA." } ], "descriptions": [ { "lang": "en", "value": "A crafted HTTP packet with a large content-length header can create a denial-of-service condition in Softing Secure Integration Server V1.22." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-125", "description": "CWE-125: Out-of-bounds Read", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2022-08-17T20:17:11", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" } ], "solutions": [ { "lang": "en", "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-4 on the Softing security website." } ], "source": { "discovery": "EXTERNAL" }, "title": "Softing Secure Integration Server Out-of-bounds Read", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2022-1069", "STATE": "PUBLIC", "TITLE": "Softing Secure Integration Server Out-of-bounds Read" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Secure Integration Server", "version": { "version_data": [ { "version_affected": "=", "version_value": "V1.22" } ] } } ] }, "vendor_name": "Softing" } ] } }, "credit": [ { "lang": "eng", "value": "Pedro Ribeiro and Radek Domanski, working with Trend Micro Zero Day Initiative, reported these vulnerabilities to Softing and CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A crafted HTTP packet with a large content-length header can create a denial-of-service condition in Softing Secure Integration Server V1.22." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-125: Out-of-bounds Read" } ] } ] }, "references": { "reference_data": [ { "name": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html", "refsource": "CONFIRM", "url": "https://industrial.softing.com/fileadmin/psirt/downloads/syt-2022-4.html" }, { "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04", "refsource": "CONFIRM", "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-228-04" } ] }, "solution": [ { "lang": "en", "value": "Softing released new versions to address these vulnerabilities and notified known users of the releases. Users are advised to update to the new versions:\nSofting Secure Integration Server V1.30 \n\nThe latest software packages can be downloaded from the Softing website. \n\nSofting recommends the following mitigations and workarounds: \nChange the admin password or create a new user with administrative rights and delete the default admin user. \nConfigure the Windows firewall to block network requests to IP port 9000. \nDisable the HTTP Server in NGINX configuration of the Softing Secure Integration Server, only using the HTTPS server. \nFor more details on these vulnerabilities and mitigations, users should see SYT-2022-4 on the Softing security website." } ], "source": { "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2022-1069", "datePublished": "2022-08-17T20:17:11", "dateReserved": "2022-03-24T00:00:00", "dateUpdated": "2024-08-02T23:47:43.266Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }