3 vulnerabilities found for emc_vnxe3200_firmware by dell
FKIE_CVE-2019-3754
Vulnerability from fkie_nvd - Published: 2019-09-03 17:15 - Updated: 2024-11-21 04:42
Severity ?
4.7 (Medium) - CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:N
6.1 (Medium) - CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
6.1 (Medium) - CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Summary
Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | emc_unity_operating_environment | * | |
| dell | emc_unityvsa_operating_environment | * | |
| dell | emc_vnxe3200_firmware | * | |
| dell | emc_vnxe3200 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:dell:emc_unity_operating_environment:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7091DD01-04E8-4560-BE2B-CC0F009C3D17",
"versionEndExcluding": "5.0.0.0.5.116",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:dell:emc_unityvsa_operating_environment:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DAC14A15-77F9-4E6F-B900-6D3FBA241999",
"versionEndExcluding": "5.0.0.0.5.116",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dell:emc_vnxe3200_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "61312D56-931F-488B-9563-2E1CBAF6F686",
"versionEndExcluding": "3.1.10.9946299",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dell:emc_vnxe3200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "3E2FB19C-F28D-4D99-B965-85CEE552D981",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser."
},
{
"lang": "es",
"value": "Dell EMC Unity Operating Environment en versiones anteriores a la 5.0.0.0.5.116, Dell EMC UnityVSA en versiones anteriores a la 5.0.0.0.5.116 y Dell EMC VNXe3200 en versiones anteriores a la 3.1.10.9946299 contienen una vulnerabilidad de Cross-Site Scripting (XSS) reflejado en la p\u00e1gina cas/logout. Un atacante remoto no identificado podr\u00eda potencialmente aprovechar esta vulnerabilidad enga\u00f1ando a un usuario de una aplicaci\u00f3n v\u00edctima para que proporcione c\u00f3digo HTML o JavaScript malicioso a Unisphere, que se devuelve a la v\u00edctima y es ejecutado por el navegador web."
}
],
"id": "CVE-2019-3754",
"lastModified": "2024-11-21T04:42:28.160",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:N",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 1.4,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-09-03T17:15:11.273",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2019-3754 (GCVE-0-2019-3754)
Vulnerability from cvelistv5 – Published: 2019-09-03 16:52 – Updated: 2024-09-17 02:00
VLAI?
Summary
Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser.
Severity ?
4.7 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DELL EMC | Unity Operating Environment |
Affected:
unspecified , < 5.0.0.0.5.116
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:19:18.181Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Unity Operating Environment",
"vendor": "DELL EMC",
"versions": [
{
"lessThan": "5.0.0.0.5.116",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "UnityVSA Operating Environment",
"vendor": "DELL EMC",
"versions": [
{
"lessThan": "5.0.0.0.5.116",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "VNXe3200 Operating Environment",
"vendor": "DELL EMC",
"versions": [
{
"lessThan": "3.1.10.9946299",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-08-27T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-03T16:52:53",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.7"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2019-08-27T16:00:00.000Z",
"ID": "CVE-2019-3754",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Unity Operating Environment",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "5.0.0.0.5.116"
}
]
}
},
{
"product_name": "UnityVSA Operating Environment",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "5.0.0.0.5.116"
}
]
}
},
{
"product_name": "VNXe3200 Operating Environment",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "3.1.10.9946299"
}
]
}
}
]
},
"vendor_name": "DELL EMC"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.7"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability",
"refsource": "CONFIRM",
"url": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2019-3754",
"datePublished": "2019-09-03T16:52:53.915317Z",
"dateReserved": "2019-01-03T00:00:00",
"dateUpdated": "2024-09-17T02:00:48.399Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-3754 (GCVE-0-2019-3754)
Vulnerability from nvd – Published: 2019-09-03 16:52 – Updated: 2024-09-17 02:00
VLAI?
Summary
Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser.
Severity ?
4.7 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DELL EMC | Unity Operating Environment |
Affected:
unspecified , < 5.0.0.0.5.116
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:19:18.181Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Unity Operating Environment",
"vendor": "DELL EMC",
"versions": [
{
"lessThan": "5.0.0.0.5.116",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "UnityVSA Operating Environment",
"vendor": "DELL EMC",
"versions": [
{
"lessThan": "5.0.0.0.5.116",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "VNXe3200 Operating Environment",
"vendor": "DELL EMC",
"versions": [
{
"lessThan": "3.1.10.9946299",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-08-27T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-03T16:52:53",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.7"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2019-08-27T16:00:00.000Z",
"ID": "CVE-2019-3754",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Unity Operating Environment",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "5.0.0.0.5.116"
}
]
}
},
{
"product_name": "UnityVSA Operating Environment",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "5.0.0.0.5.116"
}
]
}
},
{
"product_name": "VNXe3200 Operating Environment",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "3.1.10.9946299"
}
]
}
}
]
},
"vendor_name": "DELL EMC"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.7"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability",
"refsource": "CONFIRM",
"url": "https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2019-3754",
"datePublished": "2019-09-03T16:52:53.915317Z",
"dateReserved": "2019-01-03T00:00:00",
"dateUpdated": "2024-09-17T02:00:48.399Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}