Search criteria

3 vulnerabilities found for evlink_home_firmware by schneider-electric

FKIE_CVE-2024-5313

Vulnerability from fkie_nvd - Published: 2024-06-12 13:15 - Updated: 2024-11-21 09:47
Summary
CWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH interface over the product network interface. This does not allow to directly exploit the product or make any unintended operation as the SSH interface access is protected by an authentication mechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts to perform a potential denial of service attack on the exposed SSH interface.
Impacted products

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:schneider-electric:evlink_home_firmware:2.0.3.8.2_128:*:*:*:*:*:*:*",
              "matchCriteriaId": "3B763346-0129-441A-9024-D2B425E38B18",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:schneider-electric:evlink_home_firmware:2.0.4.1.2_131:*:*:*:*:*:*:*",
              "matchCriteriaId": "E0D983AB-A039-4006-B164-25EFBF6C07D0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:schneider-electric:evlink_home:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "7266ADD9-9F0F-4E95-9CB6-14550F920CBC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "CWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH\ninterface over the product network interface. This does not allow to directly exploit the product or\nmake any unintended operation as the SSH interface access is protected by an authentication\nmechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts\nto perform a potential denial of service attack on the exposed SSH interface."
    },
    {
      "lang": "es",
      "value": "CWE-668: Existe exposici\u00f3n a la vulnerabilidad Resource Wrong Sphere que expone una interfaz SSH a trav\u00e9s de la interfaz de red del producto. Esto no permite explotar directamente el producto ni realizar ninguna operaci\u00f3n no deseada ya que el acceso a la interfaz SSH est\u00e1 protegido por un mecanismo de autenticaci\u00f3n. Los impactos se limitan a actividades de escaneo de puertos y toma de huellas digitales, as\u00ed como a intentos de realizar un posible ataque de denegaci\u00f3n de servicio en la interfaz SSH expuesta."
    }
  ],
  "id": "CVE-2024-5313",
  "lastModified": "2024-11-21T09:47:24.663",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 2.5,
        "source": "cybersecurity@se.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "LOW",
          "baseScore": 6.5,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 2.5,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2024-06-12T13:15:50.343",
  "references": [
    {
      "source": "cybersecurity@se.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-03.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-03.pdf"
    }
  ],
  "sourceIdentifier": "cybersecurity@se.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-668"
        }
      ],
      "source": "cybersecurity@se.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "NVD-CWE-noinfo"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}

CVE-2024-5313 (GCVE-0-2024-5313)

Vulnerability from cvelistv5 – Published: 2024-06-12 12:14 – Updated: 2024-08-01 21:11
VLAI?
Summary
CWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH interface over the product network interface. This does not allow to directly exploit the product or make any unintended operation as the SSH interface access is protected by an authentication mechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts to perform a potential denial of service attack on the exposed SSH interface.
CWE
  • CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
Impacted products
Vendor Product Version
Schneider Electric EVlink Home Smart Affected: v2.0.4.1.2_131
Affected: v2.0.3.8.2_128
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:schneider-electric:evlink_home_smart:2.0.4.1.2_131:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "evlink_home_smart",
            "vendor": "schneider-electric",
            "versions": [
              {
                "status": "affected",
                "version": "2.0.4.1.2_131"
              },
              {
                "status": "affected",
                "version": "2.0.3.8.2_128"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5313",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T14:57:54.307091Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-12T15:04:51.869Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:11:12.332Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-03.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EVlink Home Smart",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "v2.0.4.1.2_131"
            },
            {
              "status": "affected",
              "version": "v2.0.3.8.2_128"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nCWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH\ninterface over the product network interface. This does not allow to directly exploit the product or\nmake any unintended operation as the SSH interface access is protected by an authentication\nmechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts\nto perform a potential denial of service attack on the exposed SSH interface.\n\n"
            }
          ],
          "value": "CWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH\ninterface over the product network interface. This does not allow to directly exploit the product or\nmake any unintended operation as the SSH interface access is protected by an authentication\nmechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts\nto perform a potential denial of service attack on the exposed SSH interface."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-668",
              "description": "CWE-668 Exposure of Resource to Wrong Sphere",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-12T12:14:58.979Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-03.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-5313",
    "datePublished": "2024-06-12T12:14:58.979Z",
    "dateReserved": "2024-05-24T08:29:40.058Z",
    "dateUpdated": "2024-08-01T21:11:12.332Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-5313 (GCVE-0-2024-5313)

Vulnerability from nvd – Published: 2024-06-12 12:14 – Updated: 2024-08-01 21:11
VLAI?
Summary
CWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH interface over the product network interface. This does not allow to directly exploit the product or make any unintended operation as the SSH interface access is protected by an authentication mechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts to perform a potential denial of service attack on the exposed SSH interface.
CWE
  • CWE-668 - Exposure of Resource to Wrong Sphere
Assigner
Impacted products
Vendor Product Version
Schneider Electric EVlink Home Smart Affected: v2.0.4.1.2_131
Affected: v2.0.3.8.2_128
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:schneider-electric:evlink_home_smart:2.0.4.1.2_131:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "evlink_home_smart",
            "vendor": "schneider-electric",
            "versions": [
              {
                "status": "affected",
                "version": "2.0.4.1.2_131"
              },
              {
                "status": "affected",
                "version": "2.0.3.8.2_128"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5313",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-12T14:57:54.307091Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-12T15:04:51.869Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:11:12.332Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-03.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EVlink Home Smart",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "v2.0.4.1.2_131"
            },
            {
              "status": "affected",
              "version": "v2.0.3.8.2_128"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\nCWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH\ninterface over the product network interface. This does not allow to directly exploit the product or\nmake any unintended operation as the SSH interface access is protected by an authentication\nmechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts\nto perform a potential denial of service attack on the exposed SSH interface.\n\n"
            }
          ],
          "value": "CWE-668: Exposure of the Resource Wrong Sphere vulnerability exists that exposes a SSH\ninterface over the product network interface. This does not allow to directly exploit the product or\nmake any unintended operation as the SSH interface access is protected by an authentication\nmechanism. Impacts are limited to port scanning and fingerprinting activities as well as attempts\nto perform a potential denial of service attack on the exposed SSH interface."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-668",
              "description": "CWE-668 Exposure of Resource to Wrong Sphere",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-12T12:14:58.979Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-163-03.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2024-5313",
    "datePublished": "2024-06-12T12:14:58.979Z",
    "dateReserved": "2024-05-24T08:29:40.058Z",
    "dateUpdated": "2024-08-01T21:11:12.332Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}