Search criteria
3 vulnerabilities found for factorytalk_analytics_logixai by rockwellautomation
FKIE_CVE-2025-9364
Vulnerability from fkie_nvd - Published: 2025-09-09 13:15 - Updated: 2025-09-10 14:09
Severity ?
Summary
An open database issue exists in the affected product and version. The security issue stems from an over permissive Redis instance. This could result in an attacker on the intranet accessing sensitive data and potential alteration of data.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| rockwellautomation | factorytalk_analytics_logixai | 3.00.00 | |
| rockwellautomation | factorytalk_analytics_logixai | 3.01.00 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_analytics_logixai:3.00.00:*:*:*:*:*:*:*",
"matchCriteriaId": "8DDBAD67-AAC1-4EC5-BB52-0E42862DDB6F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:rockwellautomation:factorytalk_analytics_logixai:3.01.00:*:*:*:*:*:*:*",
"matchCriteriaId": "15AE0FC4-791E-41AC-A862-26DD19D4FBF7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An open database issue exists in the affected product and version. The security issue stems from an over permissive Redis instance. This could result in an attacker on the intranet accessing sensitive data and potential alteration of data."
}
],
"id": "CVE-2025-9364",
"lastModified": "2025-09-10T14:09:05.267",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
}
]
},
"published": "2025-09-09T13:15:33.237",
"references": [
{
"source": "PSIRT@rockwellautomation.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1748.html"
}
],
"sourceIdentifier": "PSIRT@rockwellautomation.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-497"
}
],
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
}
]
}
CVE-2025-9364 (GCVE-0-2025-9364)
Vulnerability from cvelistv5 – Published: 2025-09-09 12:41 – Updated: 2025-09-09 13:36
VLAI?
Summary
An open database issue exists in the affected product and version. The security issue stems from an over permissive Redis instance. This could result in an attacker on the intranet accessing sensitive data and potential alteration of data.
Severity ?
CWE
- CWE-497 - Exposure of Sensitive System Information to an Unauthorized Control Sphere
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Rockwell Automation | FactoryTalk® Analytics™ LogixAI® |
Affected:
Versions 3.00 and 3.01
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9364",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-09T13:36:25.672379Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-09T13:36:31.291Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FactoryTalk\u00ae Analytics\u2122 LogixAI\u00ae",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "Versions 3.00 and 3.01"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn open database issue exists in the affected product and version. The security issue stems from an over permissive Redis instance. This could result in an attacker on the intranet accessing sensitive data and potential alteration of data.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
}
],
"value": "An open database issue exists in the affected product and version. The security issue stems from an over permissive Redis instance. This could result in an attacker on the intranet accessing sensitive data and potential alteration of data."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-497",
"description": "CWE-497: Exposure of Sensitive System Information to an Unauthorized Control Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-09T12:41:24.092Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1748.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Upgrade to\u0026nbsp;\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eVersion 3.02 and later\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
}
],
"value": "Upgrade to\u00a0\n\nVersion 3.02 and later"
}
],
"source": {
"advisory": "SD1748",
"discovery": "INTERNAL"
},
"title": "Rockwell Automation FactoryTalk\u00ae Analytics\u2122 LogixAI\u00ae Exposed Redis DB",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2025-9364",
"datePublished": "2025-09-09T12:41:23.124Z",
"dateReserved": "2025-08-22T15:52:49.830Z",
"dateUpdated": "2025-09-09T13:36:31.291Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-9364 (GCVE-0-2025-9364)
Vulnerability from nvd – Published: 2025-09-09 12:41 – Updated: 2025-09-09 13:36
VLAI?
Summary
An open database issue exists in the affected product and version. The security issue stems from an over permissive Redis instance. This could result in an attacker on the intranet accessing sensitive data and potential alteration of data.
Severity ?
CWE
- CWE-497 - Exposure of Sensitive System Information to an Unauthorized Control Sphere
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Rockwell Automation | FactoryTalk® Analytics™ LogixAI® |
Affected:
Versions 3.00 and 3.01
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-9364",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-09-09T13:36:25.672379Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-09-09T13:36:31.291Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "FactoryTalk\u00ae Analytics\u2122 LogixAI\u00ae",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "Versions 3.00 and 3.01"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn open database issue exists in the affected product and version. The security issue stems from an over permissive Redis instance. This could result in an attacker on the intranet accessing sensitive data and potential alteration of data.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
}
],
"value": "An open database issue exists in the affected product and version. The security issue stems from an over permissive Redis instance. This could result in an attacker on the intranet accessing sensitive data and potential alteration of data."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-497",
"description": "CWE-497: Exposure of Sensitive System Information to an Unauthorized Control Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-09-09T12:41:24.092Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1748.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Upgrade to\u0026nbsp;\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eVersion 3.02 and later\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
}
],
"value": "Upgrade to\u00a0\n\nVersion 3.02 and later"
}
],
"source": {
"advisory": "SD1748",
"discovery": "INTERNAL"
},
"title": "Rockwell Automation FactoryTalk\u00ae Analytics\u2122 LogixAI\u00ae Exposed Redis DB",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2025-9364",
"datePublished": "2025-09-09T12:41:23.124Z",
"dateReserved": "2025-08-22T15:52:49.830Z",
"dateUpdated": "2025-09-09T13:36:31.291Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}