Search criteria

220 vulnerabilities by rockwellautomation

CVE-2025-11918 (GCVE-0-2025-11918)

Vulnerability from cvelistv5 – Published: 2025-11-14 13:28 – Updated: 2025-11-14 15:44
VLAI?
Summary
Rockwell Automation Arena® suffers from a stack-based buffer overflow vulnerability. The specific flaw exists within the parsing of DOE files. Local attackers are able to exploit this issue to potentially execute arbitrary code on affected installations of Arena®. Exploiting the vulnerability requires opening a malicious DOE file.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
Impacted products
Vendor Product Version
Rockwell Automation Arena® Simulation Affected: Version 16.20.10 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-11918",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-14T15:44:06.869099Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-14T15:44:16.712Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Arena\u00ae Simulation",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "Version 16.20.10 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Rockwell Automation Arena\u00ae suffers from a\nstack-based buffer overflow vulnerability. The specific flaw exists within the\nparsing of DOE files. Local attackers are able to exploit this issue to\npotentially execute arbitrary code on affected installations of Arena\u00ae. Exploiting\nthe vulnerability requires opening a malicious DOE file.\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "Rockwell Automation Arena\u00ae suffers from a\nstack-based buffer overflow vulnerability. The specific flaw exists within the\nparsing of DOE files. Local attackers are able to exploit this issue to\npotentially execute arbitrary code on affected installations of Arena\u00ae. Exploiting\nthe vulnerability requires opening a malicious DOE file."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-14T13:28:39.453Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1763.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112\u0026amp;mode=3\u0026amp;refSoft=1\u0026amp;versions=66110\"\u003eUpgrade\nto version 16.20.11 and later\u003c/a\u003e"
            }
          ],
          "value": "Upgrade\nto version 16.20.11 and later"
        }
      ],
      "source": {
        "advisory": "SD1763",
        "discovery": "EXTERNAL"
      },
      "title": "Rockwell Automation Arena\u00ae Simulation Stack-Based Buffer Overflow Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-11918",
    "datePublished": "2025-11-14T13:28:39.453Z",
    "dateReserved": "2025-10-17T14:31:53.014Z",
    "dateUpdated": "2025-11-14T15:44:16.712Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-9067 (GCVE-0-2025-9067)

Vulnerability from cvelistv5 – Published: 2025-10-14 12:24 – Updated: 2025-10-14 18:50
VLAI?
Summary
A security issue exists within the x86 Microsoft Installer File (MSI), installed with FTLinx. Authenticated attackers with valid Windows user credentials can initiate a repair and hijack the resulting console window. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources.
CWE
  • CWE-269 - Improper Privilege Management
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9067",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T18:50:13.723131Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T18:50:28.594Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FactoryTalk Linx",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "6.40 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue exists within the x86 Microsoft Installer File (MSI), installed with FTLinx. Authenticated attackers with valid Windows user credentials can initiate a repair and hijack the resulting console window. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
            }
          ],
          "value": "A security issue exists within the x86 Microsoft Installer File (MSI), installed with FTLinx. Authenticated attackers with valid Windows user credentials can initiate a repair and hijack the resulting console window. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269: Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-14T12:24:45.641Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1754.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "6.50 and later"
            }
          ],
          "value": "6.50 and later"
        }
      ],
      "source": {
        "advisory": "SD1754",
        "discovery": "INTERNAL"
      },
      "title": "Rockwell Automation FactoryTalk\u00ae Linx Privilege Escalation Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-9067",
    "datePublished": "2025-10-14T12:24:45.641Z",
    "dateReserved": "2025-08-15T14:19:50.492Z",
    "dateUpdated": "2025-10-14T18:50:28.594Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-9068 (GCVE-0-2025-9068)

Vulnerability from cvelistv5 – Published: 2025-10-14 12:23 – Updated: 2025-10-14 18:49
VLAI?
Summary
A security issue exists within the Rockwell Automation Driver Package x64 Microsoft Installer File (MSI) repair functionality, installed with FTLinx. Authenticated attackers with valid Windows Users credentials can initiate a repair and hijack the resulting console window for vbpinstall.exe. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources.
CWE
  • CWE-269 - Improper Privilege Management
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9068",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T18:49:18.056590Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T18:49:27.564Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FactoryTalk Linx",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "6.40 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue exists within the Rockwell Automation Driver Package x64 Microsoft Installer File (MSI) repair functionality, installed with FTLinx. Authenticated attackers with valid Windows Users credentials can initiate a repair and hijack the resulting console window for vbpinstall.exe. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources. \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
            }
          ],
          "value": "A security issue exists within the Rockwell Automation Driver Package x64 Microsoft Installer File (MSI) repair functionality, installed with FTLinx. Authenticated attackers with valid Windows Users credentials can initiate a repair and hijack the resulting console window for vbpinstall.exe. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269: Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-14T12:23:45.550Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1754.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "6.50 and later"
            }
          ],
          "value": "6.50 and later"
        }
      ],
      "source": {
        "advisory": "SD1754",
        "discovery": "INTERNAL"
      },
      "title": "Rockwell Automation FactoryTalk\u00ae Linx Privilege Escalation Vulnerabilities",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-9068",
    "datePublished": "2025-10-14T12:23:45.550Z",
    "dateReserved": "2025-08-15T14:20:47.449Z",
    "dateUpdated": "2025-10-14T18:49:27.564Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-9064 (GCVE-0-2025-9064)

Vulnerability from cvelistv5 – Published: 2025-10-14 12:22 – Updated: 2025-10-14 18:46
VLAI?
Summary
A path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted.
CWE
  • CWE-287 - Improper Authentication
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9064",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T18:46:24.670147Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T18:46:34.339Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FactoryTalk View Machine Edition",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "V15.00 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
            }
          ],
          "value": "A path traversal security issue exists within FactoryTalk View Machine Edition, allowing unauthenticated attackers on the same network as the device to delete any file within the panels operating system. Exploitation of this vulnerability is dependent on the knowledge of filenames to be deleted."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287: Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-14T12:22:36.551Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1753.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cp\u003e-FactoryTalk View ME V15.00 and later on ASEM 6300 IPC\u2019s \u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e-Patch \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.rockwellautomation.com/app/answers/answer_view/a_id/1152571\"\u003eBF31001\u003c/a\u003e\u0026nbsp; \u0026nbsp;\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\u003c/div\u003e\u003cdiv\u003e\u003cp\u003e-PanelView Plus 7 Performance Series B \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112\u0026amp;mode=3\u0026amp;refSoft=1\u0026amp;versions=61168\"\u003eV14.103\u003c/a\u003e firmware package \u0026nbsp;\u003c/p\u003e\u003c/div\u003e"
            }
          ],
          "value": "-FactoryTalk View ME V15.00 and later on ASEM 6300 IPC\u2019s \n\n\n\n-Patch  BF31001 https://support.rockwellautomation.com/app/answers/answer_view/a_id/1152571 \u00a0 \u00a0\n\n\n\n\u00a0\n\n\n\n-PanelView Plus 7 Performance Series B  V14.103 https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx  firmware package"
        }
      ],
      "source": {
        "advisory": "SD1753",
        "discovery": "INTERNAL"
      },
      "title": "Rockwell Automation FactoryTalk View Machine Edition Path Traversal",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-9064",
    "datePublished": "2025-10-14T12:22:36.551Z",
    "dateReserved": "2025-08-15T13:56:26.986Z",
    "dateUpdated": "2025-10-14T18:46:34.339Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-9063 (GCVE-0-2025-9063)

Vulnerability from cvelistv5 – Published: 2025-10-14 12:20 – Updated: 2025-10-14 18:45
VLAI?
Summary
An authentication bypass security issue exists within FactoryTalk View Machine Edition Web Browser ActiveX control. Exploitation of this vulnerability allows unauthorized access to the PanelView Plus 7 Series B, including access to the file system, retrieval of diagnostic information, event logs, and more.
CWE
  • CWE-287 - Improper Authentication
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9063",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-14T18:45:42.455090Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-14T18:45:57.209Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PanelView Plus 7 Performance Series B",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "V14.00"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn authentication bypass security issue exists within FactoryTalk View Machine Edition  Web Browser ActiveX control. Exploitation of this vulnerability allows unauthorized access to the PanelView Plus 7 Series B, including access to the file system, retrieval of diagnostic information, event logs, and more. \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
            }
          ],
          "value": "An authentication bypass security issue exists within FactoryTalk View Machine Edition  Web Browser ActiveX control. Exploitation of this vulnerability allows unauthorized access to the PanelView Plus 7 Series B, including access to the file system, retrieval of diagnostic information, event logs, and more."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287: Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-14T12:20:39.318Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1753.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ePanelView Plus 7 \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ePerformance Series B\u003c/span\u003e \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx?crumb=112\u0026amp;mode=3\u0026amp;refSoft=1\u0026amp;versions=61168\"\u003eV14.103\u003c/a\u003e"
            }
          ],
          "value": "PanelView Plus 7 Performance Series B  V14.103 https://compatibility.rockwellautomation.com/Pages/MultiProductFindDownloads.aspx"
        }
      ],
      "source": {
        "advisory": "SD1753",
        "discovery": "INTERNAL"
      },
      "title": "Rockwell Automation PanelView Plus 7 Performance Series B Authentication Bypass",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-9063",
    "datePublished": "2025-10-14T12:20:39.318Z",
    "dateReserved": "2025-08-15T12:55:33.964Z",
    "dateUpdated": "2025-10-14T18:45:57.209Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-9161 (GCVE-0-2025-9161)

Vulnerability from cvelistv5 – Published: 2025-09-09 12:57 – Updated: 2025-09-09 13:18
VLAI?
Summary
A security issue exists within FactoryTalk Optix MQTT broker due to the lack of URI sanitization. This flaw enables the loading of remote Mosquito plugins, which can be used to achieve remote code execution.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
Impacted products
Vendor Product Version
Rockwell Automation FactoryTalk Optix Affected: All Versions 1.5.0 - 1.5.7
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9161",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-09T13:18:39.142088Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-09T13:18:44.719Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FactoryTalk Optix",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions 1.5.0 - 1.5.7"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue exists within FactoryTalk Optix MQTT broker due to the lack of URI sanitization. This flaw enables the loading of remote Mosquito plugins, which can be used to achieve remote code execution. \u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
            }
          ],
          "value": "A security issue exists within FactoryTalk Optix MQTT broker due to the lack of URI sanitization. This flaw enables the loading of remote Mosquito plugins, which can be used to achieve remote code execution."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-09T12:57:40.934Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1742.html"
        }
      ],
      "source": {
        "advisory": "SD1742",
        "discovery": "INTERNAL"
      },
      "title": "Rockwell Automation FactoryTalk Optix Remote Code Execution Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-9161",
    "datePublished": "2025-09-09T12:57:40.934Z",
    "dateReserved": "2025-08-19T13:03:36.727Z",
    "dateUpdated": "2025-09-09T13:18:44.719Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-9065 (GCVE-0-2025-9065)

Vulnerability from cvelistv5 – Published: 2025-09-09 12:51 – Updated: 2025-09-09 13:23
VLAI?
Summary
A server-side request forgery security issue exists within Rockwell Automation ThinManager® software due to the lack of input sanitization. Authenticated attackers can exploit this vulnerability by specifying external SMB paths, exposing the ThinServer® service account NTLM hash.
CWE
  • CWE-610 - Externally Controlled Reference to a Resource in Another Sphere
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9065",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-09T13:23:19.121711Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-09T13:23:24.291Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ThinManager",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "13.0 - 14.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA server-side request forgery security issue exists within Rockwell Automation ThinManager\u00ae software due to the lack of input sanitization. Authenticated attackers can exploit this vulnerability by specifying external SMB paths, exposing the ThinServer\u00ae service account NTLM hash.\u003c/span\u003e"
            }
          ],
          "value": "A server-side request forgery security issue exists within Rockwell Automation ThinManager\u00ae software due to the lack of input sanitization. Authenticated attackers can exploit this vulnerability by specifying external SMB paths, exposing the ThinServer\u00ae service account NTLM hash."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-610",
              "description": "CWE-610: Externally Controlled Reference to a Resource in Another Sphere",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-09T12:51:42.091Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1743.html"
        }
      ],
      "source": {
        "advisory": "SD1743",
        "discovery": "INTERNAL"
      },
      "title": "Rockwell Automation ThinManager\u00ae Server-Side Request Forgery Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-9065",
    "datePublished": "2025-09-09T12:51:42.091Z",
    "dateReserved": "2025-08-15T13:58:23.749Z",
    "dateUpdated": "2025-09-09T13:23:24.291Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-7970 (GCVE-0-2025-7970)

Vulnerability from cvelistv5 – Published: 2025-09-09 12:46 – Updated: 2025-09-09 13:35
VLAI?
Summary
A security issue exists within FactoryTalk Activation Manager. An error in the implementation of cryptography within the software could allow attackers to decrypt traffic. This could result in data exposure, session hijacking, or full communication compromise.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7970",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-09T13:35:12.189401Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-09T13:35:17.769Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FactoryTalk Activation Manager",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "5.00"
            }
          ]
        }
      ],
      "datePublic": "2025-09-09T12:46:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue exists within FactoryTalk Activation Manager.  An error in the implementation of cryptography within the software could allow attackers to decrypt traffic. This could result in data exposure, session hijacking, or full communication compromise.\u003c/span\u003e"
            }
          ],
          "value": "A security issue exists within FactoryTalk Activation Manager.  An error in the implementation of cryptography within the software could allow attackers to decrypt traffic. This could result in data exposure, session hijacking, or full communication compromise."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-09T12:46:36.372Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1741.html"
        }
      ],
      "source": {
        "advisory": "SD1741",
        "discovery": "INTERNAL"
      },
      "title": "Rockwell Automation FactoryTalk Activation Manager Lack of Encryption Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-7970",
    "datePublished": "2025-09-09T12:46:36.372Z",
    "dateReserved": "2025-07-21T19:00:46.407Z",
    "dateUpdated": "2025-09-09T13:35:17.769Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-9364 (GCVE-0-2025-9364)

Vulnerability from cvelistv5 – Published: 2025-09-09 12:41 – Updated: 2025-09-09 13:36
VLAI?
Summary
An open database issue exists in the affected product and version. The security issue stems from an over permissive Redis instance. This could result in an attacker on the intranet accessing sensitive data and potential alteration of data.
CWE
  • CWE-497 - Exposure of Sensitive System Information to an Unauthorized Control Sphere
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9364",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-09T13:36:25.672379Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-09T13:36:31.291Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FactoryTalk\u00ae Analytics\u2122 LogixAI\u00ae",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 3.00 and 3.01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn open database issue exists in the affected product and version. The security issue stems from an over permissive Redis instance. This could result in an attacker on the intranet accessing sensitive data and potential alteration of data.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
            }
          ],
          "value": "An open database issue exists in the affected product and version. The security issue stems from an over permissive Redis instance. This could result in an attacker on the intranet accessing sensitive data and potential alteration of data."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-497",
              "description": "CWE-497: Exposure of Sensitive System Information to an Unauthorized Control Sphere",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-09T12:41:24.092Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1748.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to\u0026nbsp;\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eVersion 3.02 and later\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e"
            }
          ],
          "value": "Upgrade to\u00a0\n\nVersion 3.02 and later"
        }
      ],
      "source": {
        "advisory": "SD1748",
        "discovery": "INTERNAL"
      },
      "title": "Rockwell Automation FactoryTalk\u00ae Analytics\u2122 LogixAI\u00ae Exposed Redis DB",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-9364",
    "datePublished": "2025-09-09T12:41:23.124Z",
    "dateReserved": "2025-08-22T15:52:49.830Z",
    "dateUpdated": "2025-09-09T13:36:31.291Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-7972 (GCVE-0-2025-7972)

Vulnerability from cvelistv5 – Published: 2025-08-14 14:47 – Updated: 2025-08-14 15:08
VLAI?
Summary
A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to ‘development’, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers.
CWE
  • CWE-286 - Incorrect User Management
Assigner
Impacted products
Vendor Product Version
Rockwell Automation FactoryTalk® Linx Affected: All prior to 6.50
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7972",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-14T15:06:45.964707Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-14T15:08:22.952Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FactoryTalk\u00ae Linx",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "All prior to 6.50"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to \u2018development\u2019, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers. \u003c/span\u003e"
            }
          ],
          "value": "A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to \u2018development\u2019, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-286",
              "description": "CWE-286: Incorrect User Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-14T14:54:29.154Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1735.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to version 6.50 or later."
            }
          ],
          "value": "Upgrade to version 6.50 or later."
        }
      ],
      "source": {
        "advisory": "SD1735",
        "discovery": "INTERNAL"
      },
      "title": "Rockwell Automation FactoryTalk\u00ae Linx Network Browser Security Bypass Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-7972",
    "datePublished": "2025-08-14T14:47:46.316Z",
    "dateReserved": "2025-07-21T19:25:20.271Z",
    "dateUpdated": "2025-08-14T15:08:22.952Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-7033 (GCVE-0-2025-7033)

Vulnerability from cvelistv5 – Published: 2025-08-05 13:42 – Updated: 2025-08-13 15:03
VLAI?
Summary
A memory abuse issue exists in the Rockwell Automation Arena® Simulation. A custom file can force Arena Simulation to read and write past the end of memory space. Successful use requires user action, such as opening a bad file or webpage. If used, a threat actor could execute code or disclose information.
CWE
  • CWE-122 - Heap-based Buffer Overflow
Assigner
Impacted products
Vendor Product Version
Rockwell Automation Arena® Simulation Affected: 16.20.09 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7033",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-12T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-13T15:03:41.266Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Arena\u00ae Simulation",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "16.20.09 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA memory abuse issue exists in the Rockwell Automation Arena\u00ae Simulation. A custom file can force Arena Simulation to read and write past the end of memory space. Successful use requires user action, such as opening a bad file or webpage. If used, a threat actor could execute code or disclose information.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "A memory abuse issue exists in the Rockwell Automation Arena\u00ae Simulation. A custom file can force Arena Simulation to read and write past the end of memory space. Successful use requires user action, such as opening a bad file or webpage. If used, a threat actor could execute code or disclose information."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122: Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-05T13:42:39.818Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1731.html"
        }
      ],
      "source": {
        "advisory": "1731",
        "discovery": "EXTERNAL"
      },
      "title": "Rockwell Automation Heap-based Buffer Overflow In Arena\u00ae Simulation",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-7033",
    "datePublished": "2025-08-05T13:42:37.178Z",
    "dateReserved": "2025-07-02T16:41:13.554Z",
    "dateUpdated": "2025-08-13T15:03:41.266Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-7032 (GCVE-0-2025-7032)

Vulnerability from cvelistv5 – Published: 2025-08-05 13:39 – Updated: 2025-08-13 15:03
VLAI?
Summary
A memory abuse issue exists in the Rockwell Automation Arena® Simulation. A custom file can force Arena Simulation to read and write past the end of memory space. Successful use requires user action, such as opening a bad file or webpage. If used, a threat actor could execute code or disclose information.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
Impacted products
Vendor Product Version
Rockwell Automation Arena® Simulation Affected: 16.20.09 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7032",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-12T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-13T15:03:42.573Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Arena\u00ae Simulation",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "16.20.09 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA memory abuse issue exists in the Rockwell Automation Arena\u00ae Simulation. A custom file can force Arena Simulation to read and write past the end of memory space. Successful use requires user action, such as opening a bad file or webpage. If used, a threat actor could execute code or disclose information.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "A memory abuse issue exists in the Rockwell Automation Arena\u00ae Simulation. A custom file can force Arena Simulation to read and write past the end of memory space. Successful use requires user action, such as opening a bad file or webpage. If used, a threat actor could execute code or disclose information."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-05T13:39:56.940Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1731.html"
        }
      ],
      "source": {
        "advisory": "1731",
        "discovery": "EXTERNAL"
      },
      "title": "Rockwell Automation Stack-based Buffer Overflow In Arena\u00ae Simulation",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-7032",
    "datePublished": "2025-08-05T13:39:32.769Z",
    "dateReserved": "2025-07-02T16:26:52.332Z",
    "dateUpdated": "2025-08-13T15:03:42.573Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-7025 (GCVE-0-2025-7025)

Vulnerability from cvelistv5 – Published: 2025-08-05 13:37 – Updated: 2025-08-13 15:03
VLAI?
Summary
A memory abuse issue exists in the Rockwell Automation Arena® Simulation. A custom file can force Arena Simulation to read and write past the end of memory space. Successful use requires user action, such as opening a bad file or webpage. If used, a threat actor could execute code or disclose information.
CWE
  • CWE-122 - Heap-based Buffer Overflow
Assigner
Impacted products
Vendor Product Version
Rockwell Automation Arena® Simulation Affected: 16.20.09 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7025",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-12T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-13T15:03:43.830Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Arena\u00ae Simulation",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "16.20.09 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA memory abuse issue exists in the Rockwell Automation Arena\u00ae Simulation. A custom file can force Arena Simulation to read and write past the end of memory space. Successful use requires user action, such as opening a bad file or webpage. If used, a threat actor could execute code or disclose information.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "A memory abuse issue exists in the Rockwell Automation Arena\u00ae Simulation. A custom file can force Arena Simulation to read and write past the end of memory space. Successful use requires user action, such as opening a bad file or webpage. If used, a threat actor could execute code or disclose information."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122: Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-05T13:42:27.744Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1731.html"
        }
      ],
      "source": {
        "advisory": "1731",
        "discovery": "EXTERNAL"
      },
      "title": "Rockwell Automation Heap-based Buffer Overflow In Arena\u00ae Simulation",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-7025",
    "datePublished": "2025-08-05T13:37:17.720Z",
    "dateReserved": "2025-07-02T15:16:08.763Z",
    "dateUpdated": "2025-08-13T15:03:43.830Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-6376 (GCVE-0-2025-6376)

Vulnerability from cvelistv5 – Published: 2025-07-09 20:13 – Updated: 2025-07-09 20:33
VLAI?
Summary
A remote code execution security issue exists in the Rockwell Automation Arena®.  A crafted DOE file can force Arena Simulation to write beyond the boundaries of an allocated object. Exploitation requires user interaction, such as opening a malicious file within the software. If exploited, a threat actor could execute arbitrary code on the target system. The software must run under the context of the administrator in order to cause worse case impact. This is reflected in the Rockwell CVSS score, as AT:P.
CWE
  • CWE-20 - Improper Input Validation
Assigner
Impacted products
Vendor Product Version
Rockwell Automation Arena® Affected: <=16.20.08
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-6376",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-09T20:32:56.721742Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-09T20:33:10.343Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Arena\u00ae",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c=16.20.08"
            }
          ]
        }
      ],
      "datePublic": "2025-07-09T19:31:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA remote\ncode execution security issue exists in the Rockwell Automation\u0026nbsp;Arena\u00ae.\u0026nbsp;\u0026nbsp;A crafted DOE\nfile can force Arena Simulation to write beyond the boundaries of an allocated\nobject. Exploitation\nrequires user interaction, such as opening a malicious file within the software.\nIf exploited, a threat actor could execute arbitrary code on the target system.\nThe software must run under the context of the administrator in order to cause\nworse case impact. This is reflected in the Rockwell CVSS score, as AT:P.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "A remote\ncode execution security issue exists in the Rockwell Automation\u00a0Arena\u00ae.\u00a0\u00a0A crafted DOE\nfile can force Arena Simulation to write beyond the boundaries of an allocated\nobject. Exploitation\nrequires user interaction, such as opening a malicious file within the software.\nIf exploited, a threat actor could execute arbitrary code on the target system.\nThe software must run under the context of the administrator in order to cause\nworse case impact. This is reflected in the Rockwell CVSS score, as AT:P."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "LOCAL",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-09T20:13:45.320Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1729.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Corrected in v16.20.09 and later.\u0026nbsp;"
            }
          ],
          "value": "Corrected in v16.20.09 and later."
        }
      ],
      "source": {
        "advisory": "1729",
        "discovery": "EXTERNAL"
      },
      "title": "Arena\u00ae Simulation Out-Of-Bounds Write Remote Code Execution Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-6376",
    "datePublished": "2025-07-09T20:13:45.320Z",
    "dateReserved": "2025-06-19T17:03:53.212Z",
    "dateUpdated": "2025-07-09T20:33:10.343Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-6377 (GCVE-0-2025-6377)

Vulnerability from cvelistv5 – Published: 2025-07-09 20:12 – Updated: 2025-07-09 20:39
VLAI?
Summary
A remote code execution security issue exists in the Rockwell Automation Arena®.  A crafted DOE file can force Arena Simulation to write beyond the boundaries of an allocated object. Exploitation requires user interaction, such as opening a malicious file within the software. If exploited, a threat actor could execute arbitrary code on the target system. The software must run under the context of the administrator in order to cause worse case impact. This is reflected in the Rockwell CVSS score, as AT:P.
CWE
  • CWE-20 - Improper Input Validation
Assigner
Impacted products
Vendor Product Version
Rockwell Automation Arena® Affected: <=16.20.08
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-6377",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-09T20:37:33.961481Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-09T20:39:10.481Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Arena\u00ae",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c=16.20.08"
            }
          ]
        }
      ],
      "datePublic": "2025-07-09T19:31:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA remote\ncode execution security issue exists in the Rockwell Automation\u0026nbsp;Arena\u00ae.\u0026nbsp;\u0026nbsp;A crafted DOE\nfile can force Arena Simulation to write beyond the boundaries of an allocated\nobject. Exploitation\nrequires user interaction, such as opening a malicious file within the software.\nIf exploited, a threat actor could execute arbitrary code on the target system.\nThe software must run under the context of the administrator in order to cause\nworse case impact. This is reflected in the Rockwell CVSS score, as AT:P.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
            }
          ],
          "value": "A remote\ncode execution security issue exists in the Rockwell Automation\u00a0Arena\u00ae.\u00a0\u00a0A crafted DOE\nfile can force Arena Simulation to write beyond the boundaries of an allocated\nobject. Exploitation\nrequires user interaction, such as opening a malicious file within the software.\nIf exploited, a threat actor could execute arbitrary code on the target system.\nThe software must run under the context of the administrator in order to cause\nworse case impact. This is reflected in the Rockwell CVSS score, as AT:P."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "LOCAL",
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:P/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-09T20:12:47.647Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1729.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Corrected in v16.20.09 and later.\u0026nbsp;"
            }
          ],
          "value": "Corrected in v16.20.09 and later."
        }
      ],
      "source": {
        "advisory": "1729",
        "discovery": "EXTERNAL"
      },
      "title": "Arena\u00ae Simulation Out-Of-Bounds Write Remote Code Execution Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-6377",
    "datePublished": "2025-07-09T20:12:47.647Z",
    "dateReserved": "2025-06-19T17:39:11.774Z",
    "dateUpdated": "2025-07-09T20:39:10.481Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-3618 (GCVE-0-2025-3618)

Vulnerability from cvelistv5 – Published: 2025-04-15 17:19 – Updated: 2025-04-17 17:25
VLAI?
Summary
A denial-of-service vulnerability exists in the Rockwell Automation ThinManager. The software fails to adequately verify the outcome of memory allocation while processing Type 18 messages. If exploited, a threat actor could cause a denial-of-service on the target software.
CWE
  • 119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
Assigner
Impacted products
Vendor Product Version
Rockwell Automation ThinManager Affected: v14.0.1 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3618",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-15T17:40:46.050596Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-119",
                "description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T17:25:38.739Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ThinManager",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "v14.0.1 and earlier"
            }
          ]
        }
      ],
      "datePublic": "2025-04-15T17:17:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA denial-of-service vulnerability exists in the Rockwell Automation ThinManager. The software fails to adequately verify the outcome of memory allocation while processing Type 18 messages. If exploited, a threat actor could cause a denial-of-service on the target software.\u003c/span\u003e"
            }
          ],
          "value": "A denial-of-service vulnerability exists in the Rockwell Automation ThinManager. The software fails to adequately verify the outcome of memory allocation while processing Type 18 messages. If exploited, a threat actor could cause a denial-of-service on the target software."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "119 - Improper Restriction of Operations within the Bounds of a Memory Buffer",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-15T17:19:53.368Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1727.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCorrected in v11.2.11, 12.0.9, 12.1.10, 13.0.7, 13.1.5, 13.2.4, 14.0.2 and later\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Corrected in v11.2.11, 12.0.9, 12.1.10, 13.0.7, 13.1.5, 13.2.4, 14.0.2 and later"
        }
      ],
      "source": {
        "advisory": "SD1727",
        "discovery": "EXTERNAL"
      },
      "title": "Local Privilege Escalation Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-3618",
    "datePublished": "2025-04-15T17:19:53.368Z",
    "dateReserved": "2025-04-14T23:45:33.404Z",
    "dateUpdated": "2025-04-17T17:25:38.739Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-3617 (GCVE-0-2025-3617)

Vulnerability from cvelistv5 – Published: 2025-04-15 17:17 – Updated: 2025-04-17 17:25
VLAI?
Summary
A privilege escalation vulnerability exists in the Rockwell Automation ThinManager. When the software starts up, files are deleted in the temporary folder causing the Access Control Entry of the directory to inherit permissions from the parent directory. If exploited, a threat actor could inherit elevated privileges.
CWE
  • 276 - Incorrect Default Permissions
Assigner
Impacted products
Vendor Product Version
Rockwell Automation ThinManager® Affected: 14.0.0 & 14.0.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3617",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-15T17:39:24.435001Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-276",
                "description": "CWE-276 Incorrect Default Permissions",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-17T17:25:03.386Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ThinManager\u00ae",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "14.0.0 \u0026 14.0.1"
            }
          ]
        }
      ],
      "datePublic": "2025-04-15T17:13:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA privilege escalation vulnerability exists in the Rockwell Automation ThinManager\u003c/span\u003e. When the software starts up, files are deleted in the temporary folder causing the Access Control Entry of the directory to inherit permissions from the parent directory. If exploited, a threat actor could inherit elevated privileges."
            }
          ],
          "value": "A privilege escalation vulnerability exists in the Rockwell Automation ThinManager. When the software starts up, files are deleted in the temporary folder causing the Access Control Entry of the directory to inherit permissions from the parent directory. If exploited, a threat actor could inherit elevated privileges."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "276 - Incorrect Default Permissions",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-15T17:17:25.324Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1727.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Corrected in v14.0.2 and later.\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "Corrected in v14.0.2 and later."
        }
      ],
      "source": {
        "advisory": "SD1727",
        "discovery": "EXTERNAL"
      },
      "title": "Local Privilege Escalation in ThinManager\u00ae",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-3617",
    "datePublished": "2025-04-15T17:17:25.324Z",
    "dateReserved": "2025-04-14T23:45:31.896Z",
    "dateUpdated": "2025-04-17T17:25:03.386Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-3289 (GCVE-0-2025-3289)

Vulnerability from cvelistv5 – Published: 2025-04-08 15:34 – Updated: 2025-04-08 17:28
VLAI?
Summary
A local code execution vulnerability exists in the Rockwell Automation Arena® due to a stack-based memory buffer overflow. The flaw is result of improper validation of user-supplied data. If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.
CWE
  • CWE 121 – Stack-based Buffer Overflow
Assigner
Impacted products
Vendor Product Version
Rockwell Automation Arena® Affected: 16.20.08 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3289",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T17:22:04.507558Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T17:28:45.178Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Arena\u00ae",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "16.20.08 and earlier"
            }
          ]
        }
      ],
      "datePublic": "2025-04-08T15:10:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA local code execution vulnerability exists in the Rockwell Automation\u0026nbsp;Arena\u00ae due to a stack-based memory buffer overflow. The flaw is result of improper validation of user-supplied data. If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
            }
          ],
          "value": "A local code execution vulnerability exists in the Rockwell Automation\u00a0Arena\u00ae due to a stack-based memory buffer overflow. The flaw is result of improper validation of user-supplied data. If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE 121 \u2013 Stack-based Buffer Overflow",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-08T15:34:20.927Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1726.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Corrected in v.16.20.09 and later."
            }
          ],
          "value": "Corrected in v.16.20.09 and later."
        }
      ],
      "source": {
        "advisory": "SD1726",
        "discovery": "EXTERNAL"
      },
      "title": "Local Code Execution Vulnerability in Arena\u00ae",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-3289",
    "datePublished": "2025-04-08T15:34:20.927Z",
    "dateReserved": "2025-04-04T15:34:39.967Z",
    "dateUpdated": "2025-04-08T17:28:45.178Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-3288 (GCVE-0-2025-3288)

Vulnerability from cvelistv5 – Published: 2025-04-08 15:30 – Updated: 2025-04-08 18:02
VLAI?
Summary
A local code execution vulnerability exists in the Rockwell Automation Arena® due to a threat actor being able to read outside of the allocated memory buffer. The flaw is a result of improper validation of user-supplied data.  If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.
CWE
Assigner
Impacted products
Vendor Product Version
Rockwell Automation Arena® Affected: 16.20.08 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3288",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T18:01:47.970437Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T18:02:20.870Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Arena\u00ae",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "16.20.08 and earlier"
            }
          ]
        }
      ],
      "datePublic": "2025-04-08T15:10:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA local code execution vulnerability exists in the Rockwell Automation\u0026nbsp;Arena\u00ae\u0026nbsp;due to a threat actor being able to read outside of the allocated memory buffer. The flaw is a result of improper validation of user-supplied data. \u0026nbsp;If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
            }
          ],
          "value": "A local code execution vulnerability exists in the Rockwell Automation\u00a0Arena\u00ae\u00a0due to a threat actor being able to read outside of the allocated memory buffer. The flaw is a result of improper validation of user-supplied data. \u00a0If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out of Bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-08T15:30:31.744Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1726.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Corrected in v.16.20.09 and later."
            }
          ],
          "value": "Corrected in v.16.20.09 and later."
        }
      ],
      "source": {
        "advisory": "SD1726",
        "discovery": "EXTERNAL"
      },
      "title": "Local Code Execution Vulnerability in Arena\u00ae",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-3288",
    "datePublished": "2025-04-08T15:30:31.744Z",
    "dateReserved": "2025-04-04T15:34:39.236Z",
    "dateUpdated": "2025-04-08T18:02:20.870Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-3287 (GCVE-0-2025-3287)

Vulnerability from cvelistv5 – Published: 2025-04-08 15:29 – Updated: 2025-04-08 18:06
VLAI?
Summary
A local code execution vulnerability exists in the Rockwell Automation Arena® due to a stack-based memory buffer overflow. The flaw is result of improper validation of user-supplied data. If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.
CWE
Assigner
Impacted products
Vendor Product Version
Rockwell Automation Arena® Affected: 16.20.08 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3287",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T18:03:25.647248Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T18:06:20.961Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Arena\u00ae",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "16.20.08 and earlier"
            }
          ]
        }
      ],
      "datePublic": "2025-04-08T15:10:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA local code execution vulnerability exists in the Rockwell Automation\u0026nbsp;Arena\u00ae due to a stack-based memory buffer overflow. The flaw is result of improper validation of user-supplied data. If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
            }
          ],
          "value": "A local code execution vulnerability exists in the Rockwell Automation\u00a0Arena\u00ae due to a stack-based memory buffer overflow. The flaw is result of improper validation of user-supplied data. If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out of Bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-08T15:32:24.723Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1726.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Corrected in v.16.20.09 and later."
            }
          ],
          "value": "Corrected in v.16.20.09 and later."
        }
      ],
      "source": {
        "advisory": "SD1726",
        "discovery": "EXTERNAL"
      },
      "title": "Local Code Execution Vulnerability in Arena\u00ae",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-3287",
    "datePublished": "2025-04-08T15:29:45.559Z",
    "dateReserved": "2025-04-04T15:34:38.560Z",
    "dateUpdated": "2025-04-08T18:06:20.961Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-3286 (GCVE-0-2025-3286)

Vulnerability from cvelistv5 – Published: 2025-04-08 15:28 – Updated: 2025-04-08 18:16
VLAI?
Summary
A local code execution vulnerability exists in the Rockwell Automation Arena® due to a threat actor being able to read outside of the allocated memory buffer. The flaw is a result of improper validation of user-supplied data.  If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.
CWE
Assigner
Impacted products
Vendor Product Version
Rockwell Automation Arena® Affected: 16.20.08 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3286",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T18:09:29.427262Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T18:16:28.722Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Arena\u00ae",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "16.20.08 and earlier"
            }
          ]
        }
      ],
      "datePublic": "2025-04-08T15:10:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA local code execution vulnerability exists in the Rockwell Automation\u0026nbsp;Arena\u00ae\u0026nbsp;due to a threat actor being able to read outside of the allocated memory buffer. The flaw is a result of improper validation of user-supplied data. \u0026nbsp;If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
            }
          ],
          "value": "A local code execution vulnerability exists in the Rockwell Automation\u00a0Arena\u00ae\u00a0due to a threat actor being able to read outside of the allocated memory buffer. The flaw is a result of improper validation of user-supplied data. \u00a0If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out of Bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-08T15:28:21.615Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1726.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Corrected in v.16.20.09 and later."
            }
          ],
          "value": "Corrected in v.16.20.09 and later."
        }
      ],
      "source": {
        "advisory": "SD1726",
        "discovery": "EXTERNAL"
      },
      "title": "Local Code Execution Vulnerability in Arena\u00ae",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-3286",
    "datePublished": "2025-04-08T15:28:21.615Z",
    "dateReserved": "2025-04-04T15:34:37.809Z",
    "dateUpdated": "2025-04-08T18:16:28.722Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-3285 (GCVE-0-2025-3285)

Vulnerability from cvelistv5 – Published: 2025-04-08 15:26 – Updated: 2025-04-08 18:23
VLAI?
Summary
A local code execution vulnerability exists in the Rockwell Automation Arena® due to a threat actor being able to read outside of the allocated memory buffer. The flaw is a result of improper validation of user-supplied data.  If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.
CWE
Assigner
Impacted products
Vendor Product Version
Rockwell Automation Arena® Affected: 16.20.08 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3285",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T18:20:12.459368Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T18:23:17.092Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Arena\u00ae",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "16.20.08 and earlier"
            }
          ]
        }
      ],
      "datePublic": "2025-04-08T15:10:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA local code execution vulnerability exists in the Rockwell Automation\u0026nbsp;Arena\u00ae\u0026nbsp;due to a threat actor being able to read outside of the allocated memory buffer. The flaw is a result of improper validation of user-supplied data. \u0026nbsp;If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e"
            }
          ],
          "value": "A local code execution vulnerability exists in the Rockwell Automation\u00a0Arena\u00ae\u00a0due to a threat actor being able to read outside of the allocated memory buffer. The flaw is a result of improper validation of user-supplied data. \u00a0If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out of Bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-08T15:26:52.421Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1726.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Corrected in v.16.20.09 and later."
            }
          ],
          "value": "Corrected in v.16.20.09 and later."
        }
      ],
      "source": {
        "advisory": "SD1726",
        "discovery": "EXTERNAL"
      },
      "title": "Local Code Execution Vulnerability in Arena\u00ae",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-3285",
    "datePublished": "2025-04-08T15:26:52.421Z",
    "dateReserved": "2025-04-04T15:34:35.840Z",
    "dateUpdated": "2025-04-08T18:23:17.092Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2829 (GCVE-0-2025-2829)

Vulnerability from cvelistv5 – Published: 2025-04-08 15:24 – Updated: 2025-04-08 18:27
VLAI?
Summary
A local code execution vulnerability exists in the Rockwell Automation Arena® due to a threat actor being able to write outside of the allocated memory buffer. The flaw is a result of improper validation of user-supplied data.  If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.
CWE
Assigner
Impacted products
Vendor Product Version
Rockwell Automation Arena® Affected: 16.20.08 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2829",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T18:27:35.929031Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T18:27:51.914Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Arena\u00ae",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "16.20.08 and earlier"
            }
          ]
        }
      ],
      "datePublic": "2025-04-08T15:10:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA local code execution vulnerability exists in the Rockwell Automation\u0026nbsp;Arena\u00ae\u0026nbsp;due to a threat actor being able to write outside of the allocated memory buffer. The flaw is a result of improper validation of user-supplied data.  \u0026nbsp;If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.\u003c/span\u003e\n\n\u003c/span\u003e"
            }
          ],
          "value": "A local code execution vulnerability exists in the Rockwell Automation\u00a0Arena\u00ae\u00a0due to a threat actor being able to write outside of the allocated memory buffer. The flaw is a result of improper validation of user-supplied data.  \u00a0If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-08T15:24:34.831Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1726.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Corrected in v.16.20.09 and later."
            }
          ],
          "value": "Corrected in v.16.20.09 and later."
        }
      ],
      "source": {
        "advisory": "SD1726",
        "discovery": "EXTERNAL"
      },
      "title": "Local Code Execution Vulnerability in Arena\u00ae",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-2829",
    "datePublished": "2025-04-08T15:24:34.831Z",
    "dateReserved": "2025-03-26T18:15:51.294Z",
    "dateUpdated": "2025-04-08T18:27:51.914Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2293 (GCVE-0-2025-2293)

Vulnerability from cvelistv5 – Published: 2025-04-08 15:20 – Updated: 2025-04-08 20:37
VLAI?
Summary
A local code execution vulnerability exists in the Rockwell Automation Arena® due to a threat actor being able to write outside of the allocated memory buffer. The flaw is a result of improper validation of user-supplied data.  If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.
CWE
Assigner
Impacted products
Vendor Product Version
Rockwell Automation Arena® Affected: 16.20.08 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2293",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T20:37:11.653892Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T20:37:34.048Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Arena\u00ae",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "16.20.08 and earlier"
            }
          ]
        }
      ],
      "datePublic": "2025-04-08T15:10:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA local code execution vulnerability exists in the Rockwell Automation\u0026nbsp;Arena\u00ae\u0026nbsp;due to a threat actor being able to write outside of the allocated memory buffer. The flaw is a result of improper validation of user-supplied data.  \u0026nbsp;If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.\u003c/span\u003e\n\n\u003c/span\u003e"
            }
          ],
          "value": "A local code execution vulnerability exists in the Rockwell Automation\u00a0Arena\u00ae\u00a0due to a threat actor being able to write outside of the allocated memory buffer. The flaw is a result of improper validation of user-supplied data.  \u00a0If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-08T15:20:06.355Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1726.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Corrected in v.16.20.09 and later."
            }
          ],
          "value": "Corrected in v.16.20.09 and later."
        }
      ],
      "source": {
        "advisory": "SD1726",
        "discovery": "EXTERNAL"
      },
      "title": "Local Code Execution Vulnerability in Arena\u00ae",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-2293",
    "datePublished": "2025-04-08T15:20:06.355Z",
    "dateReserved": "2025-03-13T18:34:52.452Z",
    "dateUpdated": "2025-04-08T20:37:34.048Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2288 (GCVE-0-2025-2288)

Vulnerability from cvelistv5 – Published: 2025-04-08 15:19 – Updated: 2025-04-08 20:38
VLAI?
Summary
A local code execution vulnerability exists in the Rockwell Automation Arena® due to a threat actor being able to write outside of the allocated memory buffer. The flaw is a result of improper validation of user-supplied data.  If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.
CWE
Assigner
Impacted products
Vendor Product Version
Rockwell Automation Arena® Affected: 16.20.08 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2288",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T20:37:55.403674Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T20:38:07.069Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Arena\u00ae",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "16.20.08 and earlier"
            }
          ]
        }
      ],
      "datePublic": "2025-04-08T15:10:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA local code execution vulnerability exists in the Rockwell Automation\u0026nbsp;Arena\u00ae\u0026nbsp;due to a threat actor being able to write outside of the allocated memory buffer. The flaw is a result of improper validation of user-supplied data.  \u0026nbsp;If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.\u003c/span\u003e\n\n\u003c/span\u003e"
            }
          ],
          "value": "A local code execution vulnerability exists in the Rockwell Automation\u00a0Arena\u00ae\u00a0due to a threat actor being able to write outside of the allocated memory buffer. The flaw is a result of improper validation of user-supplied data.  \u00a0If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-08T15:19:30.666Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1726.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Corrected in v.16.20.09 and later."
            }
          ],
          "value": "Corrected in v.16.20.09 and later."
        }
      ],
      "source": {
        "advisory": "SD1726",
        "discovery": "EXTERNAL"
      },
      "title": "Local Code Execution Vulnerability in Arena\u00ae",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-2288",
    "datePublished": "2025-04-08T15:19:30.666Z",
    "dateReserved": "2025-03-13T16:24:57.697Z",
    "dateUpdated": "2025-04-08T20:38:07.069Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2287 (GCVE-0-2025-2287)

Vulnerability from cvelistv5 – Published: 2025-04-08 15:16 – Updated: 2025-04-09 13:12
VLAI?
Summary
A local code execution vulnerability exists in the Rockwell Automation Arena®  due to an uninitialized pointer. The flaw is result of improper validation of user-supplied data. If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.
CWE
Assigner
Impacted products
Vendor Product Version
Rockwell Automation Arena® Affected: 16.20.08 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2287",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-09T13:10:54.294130Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-09T13:12:00.236Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Arena\u00ae",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "16.20.08 and earlier"
            }
          ]
        }
      ],
      "datePublic": "2025-04-08T15:10:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA local code execution vulnerability exists in the Rockwell Automation\u0026nbsp;Arena\u00ae \u0026nbsp;due to an uninitialized pointer. The flaw is result of improper validation of user-supplied data.  If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.\u003c/span\u003e"
            }
          ],
          "value": "A local code execution vulnerability exists in the Rockwell Automation\u00a0Arena\u00ae \u00a0due to an uninitialized pointer. The flaw is result of improper validation of user-supplied data.  If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-457",
              "description": "CWE-457 Uninitialized Variable",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-08T15:16:58.829Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1726.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Corrected in v.16.20.09 and later."
            }
          ],
          "value": "Corrected in v.16.20.09 and later."
        }
      ],
      "source": {
        "advisory": "SD1726",
        "discovery": "EXTERNAL"
      },
      "title": "Local Code Execution Vulnerability in Arena\u00ae",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-2287",
    "datePublished": "2025-04-08T15:16:58.829Z",
    "dateReserved": "2025-03-13T16:24:57.113Z",
    "dateUpdated": "2025-04-09T13:12:00.236Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2286 (GCVE-0-2025-2286)

Vulnerability from cvelistv5 – Published: 2025-04-08 15:16 – Updated: 2025-04-08 15:36
VLAI?
Summary
A local code execution vulnerability exists in the Rockwell Automation Arena®  due to an uninitialized pointer. The flaw is result of improper validation of user-supplied data. If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.
CWE
Assigner
Impacted products
Vendor Product Version
Rockwell Automation Arena® Affected: 16.20.08 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2286",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T15:36:32.252186Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T15:36:43.255Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Arena\u00ae",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "16.20.08 and earlier"
            }
          ]
        }
      ],
      "datePublic": "2025-04-08T15:10:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA local code execution vulnerability exists in the Rockwell Automation\u0026nbsp;Arena\u00ae \u0026nbsp;due to an uninitialized pointer. The flaw is result of improper validation of user-supplied data.  If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.\u003c/span\u003e"
            }
          ],
          "value": "A local code execution vulnerability exists in the Rockwell Automation\u00a0Arena\u00ae \u00a0due to an uninitialized pointer. The flaw is result of improper validation of user-supplied data.  If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-457",
              "description": "CWE-457 Uninitialized Variable",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-08T15:16:45.675Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1726.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Corrected in v.16.20.09 and later."
            }
          ],
          "value": "Corrected in v.16.20.09 and later."
        }
      ],
      "source": {
        "advisory": "SD1726",
        "discovery": "EXTERNAL"
      },
      "title": "Local Code Execution Vulnerability in Arena\u00ae",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-2286",
    "datePublished": "2025-04-08T15:16:00.777Z",
    "dateReserved": "2025-03-13T16:24:53.973Z",
    "dateUpdated": "2025-04-08T15:36:43.255Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-2285 (GCVE-0-2025-2285)

Vulnerability from cvelistv5 – Published: 2025-04-08 15:15 – Updated: 2025-04-08 15:37
VLAI?
Summary
A local code execution vulnerability exists in the Rockwell Automation Arena®  due to an uninitialized pointer. The flaw is result of improper validation of user-supplied data. If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.
CWE
Assigner
Impacted products
Vendor Product Version
Rockwell Automation Arena® Affected: 16.20.08 and earlier
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-2285",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-08T15:37:04.447730Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-08T15:37:13.536Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Arena\u00ae",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "16.20.08 and earlier"
            }
          ]
        }
      ],
      "datePublic": "2025-04-08T15:10:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA local code execution vulnerability exists in the Rockwell Automation\u0026nbsp;Arena\u00ae \u0026nbsp;due to an uninitialized pointer. The flaw is result of improper validation of user-supplied data.  If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file.\u003c/span\u003e"
            }
          ],
          "value": "A local code execution vulnerability exists in the Rockwell Automation\u00a0Arena\u00ae \u00a0due to an uninitialized pointer. The flaw is result of improper validation of user-supplied data.  If exploited a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-457",
              "description": "CWE-457 Uninitialized Variable",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-04-08T15:15:11.249Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1726.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Corrected in v.16.20.09."
            }
          ],
          "value": "Corrected in v.16.20.09."
        }
      ],
      "source": {
        "advisory": "SD1726",
        "discovery": "EXTERNAL"
      },
      "title": "Local Code Execution Vulnerability in Arena\u00ae",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-2285",
    "datePublished": "2025-04-08T15:15:11.249Z",
    "dateReserved": "2025-03-13T16:19:28.171Z",
    "dateUpdated": "2025-04-08T15:37:13.536Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-0477 (GCVE-0-2025-0477)

Vulnerability from cvelistv5 – Published: 2025-01-30 17:49 – Updated: 2025-02-12 19:51
VLAI?
Summary
An encryption vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre. The vulnerability exists due to a weak encryption methodology and could allow a threat actor to extract passwords belonging to other users of the application.
CWE
  • CWE-522 - Insufficiently Protected Credentials
Assigner
Impacted products
Vendor Product Version
Rockwell Automation FactoryTalk® AssetCentre Affected: All prior to V15.00.001
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-0477",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-30T19:46:12.924131Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-12T19:51:11.151Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FactoryTalk\u00ae AssetCentre",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "All prior to V15.00.001"
            }
          ]
        }
      ],
      "datePublic": "2025-01-30T17:32:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eAn encryption vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk\u00ae AssetCentre. The vulnerability exists due to a weak encryption methodology and could allow a threat actor to extract passwords belonging to other users of the application.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "An encryption vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk\u00ae AssetCentre. The vulnerability exists due to a weak encryption methodology and could allow a threat actor to extract passwords belonging to other users of the application."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-522",
              "description": "CWE-522 Insufficiently Protected Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-30T17:49:03.933Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1721.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCorrected in V15.00.01 and later.\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "Corrected in V15.00.01 and later."
        }
      ],
      "source": {
        "advisory": "SD1721",
        "discovery": "EXTERNAL"
      },
      "title": "Rockwell Automation FactoryTalk\u00ae AssetCentre Data Exposure Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-0477",
    "datePublished": "2025-01-30T17:49:03.933Z",
    "dateReserved": "2025-01-14T21:25:49.213Z",
    "dateUpdated": "2025-02-12T19:51:11.151Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-0497 (GCVE-0-2025-0497)

Vulnerability from cvelistv5 – Published: 2025-01-30 17:40 – Updated: 2025-02-12 19:51
VLAI?
Summary
A data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk® AssetCentre. The vulnerability exists due to storing credentials in the configuration file of EventLogAttachmentExtractor, ArchiveExtractor, LogCleanUp, or ArchiveLogCleanUp packages.
CWE
  • CWE-522 - Insufficiently Protected Credentials
Assigner
Impacted products
Vendor Product Version
Rockwell Automation FactoryTalk® AssetCentre Affected: All prior to V15.00.001
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-0497",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-30T19:51:59.102106Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-12T19:51:11.273Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FactoryTalk\u00ae AssetCentre",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "All prior to V15.00.001"
            }
          ]
        }
      ],
      "datePublic": "2025-01-30T17:32:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk\u00ae AssetCentre. The vulnerability exists due to storing credentials in the configuration file of EventLogAttachmentExtractor, ArchiveExtractor, LogCleanUp, or ArchiveLogCleanUp packages.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "A data exposure vulnerability exists in all versions prior to V15.00.001 of Rockwell Automation FactoryTalk\u00ae AssetCentre. The vulnerability exists due to storing credentials in the configuration file of EventLogAttachmentExtractor, ArchiveExtractor, LogCleanUp, or ArchiveLogCleanUp packages."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-522",
              "description": "CWE-522 Insufficiently Protected Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-30T17:40:51.775Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1721.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Corrected in:\u003cbr\u003e\u003cbr\u003e\n\n\u003cp\u003eV11, V12, and V13 (patch available)\u003c/p\u003e\u003cp\u003eV15.00.01 and later\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Corrected in:\n\n\n\nV11, V12, and V13 (patch available)\n\nV15.00.01 and later"
        }
      ],
      "source": {
        "advisory": "SD1721",
        "discovery": "EXTERNAL"
      },
      "title": "Rockwell Automation FactoryTalk\u00ae AssetCentre Data Exposure Vulnerability",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2025-0497",
    "datePublished": "2025-01-30T17:40:51.775Z",
    "dateReserved": "2025-01-15T15:46:06.135Z",
    "dateUpdated": "2025-02-12T19:51:11.273Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",