Search criteria
116 vulnerabilities found for fh1206_firmware by tenda
CVE-2025-14994 (GCVE-0-2025-14994)
Vulnerability from nvd – Published: 2025-12-21 07:32 – Updated: 2025-12-22 16:36
VLAI?
Title
Tenda FH1201/FH1206 HTTP Request webtypelibrary strcat stack-based overflow
Summary
A flaw has been found in Tenda FH1201 and FH1206 1.2.0.14(408)/1.2.0.8(8155). This impacts the function strcat of the file /goform/webtypelibrary of the component HTTP Request Handler. This manipulation of the argument webSiteId causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
Impacted products
Credits
z472421519 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-14994",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-22T16:36:14.706437Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-22T16:36:21.363Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"HTTP Request Handler"
],
"product": "FH1201",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.8(8155)"
},
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
},
{
"modules": [
"HTTP Request Handler"
],
"product": "FH1206",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.8(8155)"
},
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "z472421519 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Tenda FH1201 and FH1206 1.2.0.14(408)/1.2.0.8(8155). This impacts the function strcat of the file /goform/webtypelibrary of the component HTTP Request Handler. This manipulation of the argument webSiteId causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-21T07:32:08.767Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-337688 | Tenda FH1201/FH1206 HTTP Request webtypelibrary strcat stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.337688"
},
{
"name": "VDB-337688 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.337688"
},
{
"name": "Submit #719153 | Tenda FH1201 V1.2.0.14(408) Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.719153"
},
{
"name": "Submit #719155 | Tenda FH1206 1.2.0.8(8155) Stack-based Buffer Overflow (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.719155"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/z472421519/BinaryAudit/blob/main/PoC/BOF/Tenda_FH1201/webtyplibrary/webtypelibrary.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/z472421519/BinaryAudit/blob/main/PoC/BOF/Tenda_FH1206/webtyplibrary/webtypelibrary.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-12-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-12-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-12-20T13:31:24.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1201/FH1206 HTTP Request webtypelibrary strcat stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-14994",
"datePublished": "2025-12-21T07:32:08.767Z",
"dateReserved": "2025-12-20T12:22:17.860Z",
"dateUpdated": "2025-12-22T16:36:21.363Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-12002 (GCVE-0-2024-12002)
Vulnerability from nvd – Published: 2024-11-30 13:00 – Updated: 2024-12-02 15:54
VLAI?
Title
Tenda FH451/FH1201/FH1202/FH1206 GetIPTV websReadEvent null pointer dereference
Summary
A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Severity ?
4.3 (Medium)
4.3 (Medium)
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
Credits
Kalv1n2077 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-12002",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-02T15:53:24.555896Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-02T15:54:21.033Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH451",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241129"
}
]
},
{
"product": "FH1201",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241129"
}
]
},
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241129"
}
]
},
{
"product": "FH1206",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241129"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Kalv1n2077 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda FH451, FH1201, FH1202 and FH1206 bis 20241129 wurde eine problematische Schwachstelle entdeckt. Betroffen ist die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 4,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-404",
"description": "Denial of Service",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-30T13:00:14.751Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-286417 | Tenda FH451/FH1201/FH1202/FH1206 GetIPTV websReadEvent null pointer dereference",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.286417"
},
{
"name": "VDB-286417 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.286417"
},
{
"name": "Submit #453974 | Tenda FH451/FH1201/FH1202/FH1206 FH451-V1.0.0.9/FH451-V1.0.0.7/FH451-V1.0.0.5/FH1201-V1.2.0.14(408)_EN/FH1201-V1.2.0.8(8155)/FH1202-V1.2.0.14(408)/etc NULL Pointer Dereference",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.453974"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Kalvin2077/tenda-fh-cve"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-11-29T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-11-29T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-11-29T16:54:22.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH451/FH1201/FH1202/FH1206 GetIPTV websReadEvent null pointer dereference"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-12002",
"datePublished": "2024-11-30T13:00:14.751Z",
"dateReserved": "2024-11-29T15:49:13.514Z",
"dateUpdated": "2024-12-02T15:54:21.033Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-44390 (GCVE-0-2024-44390)
Vulnerability from nvd – Published: 2024-08-23 00:00 – Updated: 2024-08-23 16:53
VLAI?
Summary
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function formWrlsafeset.
Severity ?
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:fh1206_firmware:1.2.0.8\\(8155\\)_en:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fh1206_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.8\\(8155\\)_en"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-44390",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-23T16:53:12.497414Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-23T16:53:52.431Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function formWrlsafeset."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-23T16:16:50.359597",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/GroundCTL2MajorTom/pocs/blob/main/tenda_FH1206_buffer_overflow8.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-44390",
"datePublished": "2024-08-23T00:00:00",
"dateReserved": "2024-08-21T00:00:00",
"dateUpdated": "2024-08-23T16:53:52.431Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-44387 (GCVE-0-2024-44387)
Vulnerability from nvd – Published: 2024-08-23 00:00 – Updated: 2024-08-23 17:00
VLAI?
Summary
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the functino formWrlExtraGet.
Severity ?
6.5 (Medium)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:fh1206_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fh1206_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.8\\(8155\\)_en"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-44387",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-23T16:54:00.527581Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-23T17:00:19.365Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the functino formWrlExtraGet."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-23T16:24:52.272074",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/GroundCTL2MajorTom/pocs/blob/main/tenda_FH1206_buffer_overflow1.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-44387",
"datePublished": "2024-08-23T00:00:00",
"dateReserved": "2024-08-21T00:00:00",
"dateUpdated": "2024-08-23T17:00:19.365Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-44386 (GCVE-0-2024-44386)
Vulnerability from nvd – Published: 2024-08-23 00:00 – Updated: 2024-08-23 18:48
VLAI?
Summary
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function fromSetIpBind.
Severity ?
7.3 (High)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:fh1206_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fh1206_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.8(8155)"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-44386",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-23T18:22:24.334012Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-23T18:48:47.900Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function fromSetIpBind."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-23T16:06:26.158418",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/GroundCTL2MajorTom/pocs/blob/main/tenda_FH1206_buffer_overflow2.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-44386",
"datePublished": "2024-08-23T00:00:00",
"dateReserved": "2024-08-21T00:00:00",
"dateUpdated": "2024-08-23T18:48:47.900Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-14994 (GCVE-0-2025-14994)
Vulnerability from cvelistv5 – Published: 2025-12-21 07:32 – Updated: 2025-12-22 16:36
VLAI?
Title
Tenda FH1201/FH1206 HTTP Request webtypelibrary strcat stack-based overflow
Summary
A flaw has been found in Tenda FH1201 and FH1206 1.2.0.14(408)/1.2.0.8(8155). This impacts the function strcat of the file /goform/webtypelibrary of the component HTTP Request Handler. This manipulation of the argument webSiteId causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used.
Severity ?
Assigner
References
| URL | Tags | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||
Impacted products
Credits
z472421519 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-14994",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-22T16:36:14.706437Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-12-22T16:36:21.363Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"HTTP Request Handler"
],
"product": "FH1201",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.8(8155)"
},
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
},
{
"modules": [
"HTTP Request Handler"
],
"product": "FH1206",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.8(8155)"
},
{
"status": "affected",
"version": "1.2.0.14(408)"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "z472421519 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw has been found in Tenda FH1201 and FH1206 1.2.0.14(408)/1.2.0.8(8155). This impacts the function strcat of the file /goform/webtypelibrary of the component HTTP Request Handler. This manipulation of the argument webSiteId causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-21T07:32:08.767Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-337688 | Tenda FH1201/FH1206 HTTP Request webtypelibrary strcat stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.337688"
},
{
"name": "VDB-337688 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.337688"
},
{
"name": "Submit #719153 | Tenda FH1201 V1.2.0.14(408) Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.719153"
},
{
"name": "Submit #719155 | Tenda FH1206 1.2.0.8(8155) Stack-based Buffer Overflow (Duplicate)",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.719155"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/z472421519/BinaryAudit/blob/main/PoC/BOF/Tenda_FH1201/webtyplibrary/webtypelibrary.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/z472421519/BinaryAudit/blob/main/PoC/BOF/Tenda_FH1206/webtyplibrary/webtypelibrary.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-12-20T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-12-20T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-12-20T13:31:24.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH1201/FH1206 HTTP Request webtypelibrary strcat stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-14994",
"datePublished": "2025-12-21T07:32:08.767Z",
"dateReserved": "2025-12-20T12:22:17.860Z",
"dateUpdated": "2025-12-22T16:36:21.363Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-12002 (GCVE-0-2024-12002)
Vulnerability from cvelistv5 – Published: 2024-11-30 13:00 – Updated: 2024-12-02 15:54
VLAI?
Title
Tenda FH451/FH1201/FH1202/FH1206 GetIPTV websReadEvent null pointer dereference
Summary
A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
Severity ?
4.3 (Medium)
4.3 (Medium)
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
Credits
Kalv1n2077 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-12002",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-02T15:53:24.555896Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-02T15:54:21.033Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "FH451",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241129"
}
]
},
{
"product": "FH1201",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241129"
}
]
},
{
"product": "FH1202",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241129"
}
]
},
{
"product": "FH1206",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "20241129"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Kalv1n2077 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "In Tenda FH451, FH1201, FH1202 and FH1206 bis 20241129 wurde eine problematische Schwachstelle entdeckt. Betroffen ist die Funktion websReadEvent der Datei /goform/GetIPTV. Durch Beeinflussen des Arguments Content-Length mit unbekannten Daten kann eine null pointer dereference-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 4,
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "NULL Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-404",
"description": "Denial of Service",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-30T13:00:14.751Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-286417 | Tenda FH451/FH1201/FH1202/FH1206 GetIPTV websReadEvent null pointer dereference",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.286417"
},
{
"name": "VDB-286417 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.286417"
},
{
"name": "Submit #453974 | Tenda FH451/FH1201/FH1202/FH1206 FH451-V1.0.0.9/FH451-V1.0.0.7/FH451-V1.0.0.5/FH1201-V1.2.0.14(408)_EN/FH1201-V1.2.0.8(8155)/FH1202-V1.2.0.14(408)/etc NULL Pointer Dereference",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.453974"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Kalvin2077/tenda-fh-cve"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2024-11-29T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2024-11-29T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2024-11-29T16:54:22.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda FH451/FH1201/FH1202/FH1206 GetIPTV websReadEvent null pointer dereference"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2024-12002",
"datePublished": "2024-11-30T13:00:14.751Z",
"dateReserved": "2024-11-29T15:49:13.514Z",
"dateUpdated": "2024-12-02T15:54:21.033Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-44390 (GCVE-0-2024-44390)
Vulnerability from cvelistv5 – Published: 2024-08-23 00:00 – Updated: 2024-08-23 16:53
VLAI?
Summary
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function formWrlsafeset.
Severity ?
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:fh1206_firmware:1.2.0.8\\(8155\\)_en:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fh1206_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.8\\(8155\\)_en"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-44390",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-23T16:53:12.497414Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-23T16:53:52.431Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function formWrlsafeset."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-23T16:16:50.359597",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/GroundCTL2MajorTom/pocs/blob/main/tenda_FH1206_buffer_overflow8.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-44390",
"datePublished": "2024-08-23T00:00:00",
"dateReserved": "2024-08-21T00:00:00",
"dateUpdated": "2024-08-23T16:53:52.431Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-44387 (GCVE-0-2024-44387)
Vulnerability from cvelistv5 – Published: 2024-08-23 00:00 – Updated: 2024-08-23 17:00
VLAI?
Summary
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the functino formWrlExtraGet.
Severity ?
6.5 (Medium)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:fh1206_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fh1206_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.8\\(8155\\)_en"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-44387",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-23T16:54:00.527581Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-23T17:00:19.365Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the functino formWrlExtraGet."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-23T16:24:52.272074",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/GroundCTL2MajorTom/pocs/blob/main/tenda_FH1206_buffer_overflow1.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-44387",
"datePublished": "2024-08-23T00:00:00",
"dateReserved": "2024-08-21T00:00:00",
"dateUpdated": "2024-08-23T17:00:19.365Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-44386 (GCVE-0-2024-44386)
Vulnerability from cvelistv5 – Published: 2024-08-23 00:00 – Updated: 2024-08-23 18:48
VLAI?
Summary
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function fromSetIpBind.
Severity ?
7.3 (High)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:tenda:fh1206_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "fh1206_firmware",
"vendor": "tenda",
"versions": [
{
"status": "affected",
"version": "1.2.0.8(8155)"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-44386",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-23T18:22:24.334012Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-23T18:48:47.900Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function fromSetIpBind."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-23T16:06:26.158418",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/GroundCTL2MajorTom/pocs/blob/main/tenda_FH1206_buffer_overflow2.md"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-44386",
"datePublished": "2024-08-23T00:00:00",
"dateReserved": "2024-08-21T00:00:00",
"dateUpdated": "2024-08-23T18:48:47.900Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
FKIE_CVE-2024-12002
Vulnerability from fkie_nvd - Published: 2024-11-30 13:15 - Updated: 2024-12-10 23:21
Severity ?
4.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Summary
A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
References
| URL | Tags | ||
|---|---|---|---|
| cna@vuldb.com | https://github.com/Kalvin2077/tenda-fh-cve | Exploit, Third Party Advisory | |
| cna@vuldb.com | https://vuldb.com/?ctiid.286417 | Permissions Required, VDB Entry | |
| cna@vuldb.com | https://vuldb.com/?id.286417 | Third Party Advisory, VDB Entry | |
| cna@vuldb.com | https://vuldb.com/?submit.453974 | Third Party Advisory, VDB Entry | |
| cna@vuldb.com | https://www.tenda.com.cn/ | Product |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh451_firmware | 1.0.0.5 | |
| tenda | fh451_firmware | 1.0.0.7 | |
| tenda | fh451_firmware | 1.0.0.9 | |
| tenda | fh451 | - | |
| tenda | fh1201_firmware | 1.2.0.8\(8155\) | |
| tenda | fh1201_firmware | 1.2.0.14\(408\)_en | |
| tenda | fh1201 | - | |
| tenda | fh1202_firmware | 1.2.0.9 | |
| tenda | fh1202_firmware | 1.2.0.14\(408\) | |
| tenda | fh1202_firmware | 1.2.0.14\(408\)_en | |
| tenda | fh1202 | - | |
| tenda | fh1206_firmware | 1.2.0.8\(8155\) | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh451_firmware:1.0.0.5:*:*:*:*:*:*:*",
"matchCriteriaId": "645BB5C8-F542-4D2A-81EB-168982028C42",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tenda:fh451_firmware:1.0.0.7:*:*:*:*:*:*:*",
"matchCriteriaId": "7587331C-8CDC-43FA-869B-CACC9E39CC4F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tenda:fh451_firmware:1.0.0.9:*:*:*:*:*:*:*",
"matchCriteriaId": "A7521568-7BCD-43F8-9F20-440DF3919D5D",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh451:-:*:*:*:*:*:*:*",
"matchCriteriaId": "97A8BF83-E42A-4D6B-A52D-146FE1AEE2B0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.8\\(8155\\):*:*:*:*:*:*:*",
"matchCriteriaId": "0368A8C0-C2C0-477E-A0C2-4D941B963520",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tenda:fh1201_firmware:1.2.0.14\\(408\\)_en:*:*:*:*:*:*:*",
"matchCriteriaId": "84F68F46-077A-48C8-AA85-342A2264BF1C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1201:-:*:*:*:*:*:*:*",
"matchCriteriaId": "67A1C59D-AE12-4410-9173-B9B9A72B3AE4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.9:*:*:*:*:*:*:*",
"matchCriteriaId": "9DA584AC-7E1F-4FF7-91EA-F82AC2D2D3CC",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\\(408\\):*:*:*:*:*:*:*",
"matchCriteriaId": "B9FD9D0A-39F4-4AD8-AEE0-71C9E77D2799",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:tenda:fh1202_firmware:1.2.0.14\\(408\\)_en:*:*:*:*:*:*:*",
"matchCriteriaId": "9A318B1F-C8E5-4C39-A1B3-83C5693CEB61",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1202:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4A632A11-60A0-457C-A039-BED32F83BD52",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:1.2.0.8\\(8155\\):*:*:*:*:*:*:*",
"matchCriteriaId": "066BD21A-2694-474D-B885-6E9A2A1DBCFF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as problematic was found in Tenda FH451, FH1201, FH1202 and FH1206 up to 20241129. Affected by this vulnerability is the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack can be launched remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "es",
"value": "Se ha detectado una vulnerabilidad clasificada como problem\u00e1tica en Tenda FH451, FH1201, FH1202 y FH1206 hasta 20241129. Esta vulnerabilidad afecta a la funci\u00f3n websReadEvent del archivo /goform/GetIPTV. La manipulaci\u00f3n del argumento Content-Length provoca la desreferenciaci\u00f3n de un puntero nulo. El ataque puede ejecutarse de forma remota. El exploit ha sido divulgado al p\u00fablico y puede utilizarse."
}
],
"id": "CVE-2024-12002",
"lastModified": "2024-12-10T23:21:19.827",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "cna@vuldb.com",
"type": "Secondary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 1.4,
"source": "cna@vuldb.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "cna@vuldb.com",
"type": "Secondary"
}
]
},
"published": "2024-11-30T13:15:04.610",
"references": [
{
"source": "cna@vuldb.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/Kalvin2077/tenda-fh-cve"
},
{
"source": "cna@vuldb.com",
"tags": [
"Permissions Required",
"VDB Entry"
],
"url": "https://vuldb.com/?ctiid.286417"
},
{
"source": "cna@vuldb.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?id.286417"
},
{
"source": "cna@vuldb.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://vuldb.com/?submit.453974"
},
{
"source": "cna@vuldb.com",
"tags": [
"Product"
],
"url": "https://www.tenda.com.cn/"
}
],
"sourceIdentifier": "cna@vuldb.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-404"
},
{
"lang": "en",
"value": "CWE-476"
}
],
"source": "cna@vuldb.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-476"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2024-44387
Vulnerability from fkie_nvd - Published: 2024-08-23 17:15 - Updated: 2024-12-13 15:15
Severity ?
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the functino formWrlExtraGet.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh1206_firmware | 1.2.0.8\(8155\) | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:1.2.0.8\\(8155\\):*:*:*:*:*:*:*",
"matchCriteriaId": "066BD21A-2694-474D-B885-6E9A2A1DBCFF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the functino formWrlExtraGet."
},
{
"lang": "es",
"value": "Tenda FH1206 V1.2.0.8(8155)_EN contiene una vulnerabilidad de desbordamiento de b\u00fafer a trav\u00e9s de la funci\u00f3n formWrlExtraGet."
}
],
"id": "CVE-2024-44387",
"lastModified": "2024-12-13T15:15:24.313",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-08-23T17:15:10.243",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Broken Link"
],
"url": "https://github.com/GroundCTL2MajorTom/pocs/blob/main/tenda_FH1206_buffer_overflow1.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-44390
Vulnerability from fkie_nvd - Published: 2024-08-23 17:15 - Updated: 2024-12-13 15:15
Severity ?
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.0 (High) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.0 (High) - CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function formWrlsafeset.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh1206_firmware | 1.2.0.8\(8155\) | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:1.2.0.8\\(8155\\):*:*:*:*:*:*:*",
"matchCriteriaId": "066BD21A-2694-474D-B885-6E9A2A1DBCFF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function formWrlsafeset."
},
{
"lang": "es",
"value": "Tenda FH1206 V1.2.0.8(8155)_EN contiene una vulnerabilidad de desbordamiento de b\u00fafer a trav\u00e9s de la funci\u00f3n formWrlsafeset."
}
],
"id": "CVE-2024-44390",
"lastModified": "2024-12-13T15:15:13.767",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.1,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-08-23T17:15:10.300",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Broken Link"
],
"url": "https://github.com/GroundCTL2MajorTom/pocs/blob/main/tenda_FH1206_buffer_overflow8.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-44386
Vulnerability from fkie_nvd - Published: 2024-08-23 16:15 - Updated: 2025-04-04 14:37
Severity ?
Summary
Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function fromSetIpBind.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh1206_firmware | 1.2.0.8\(8155\)_en | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:1.2.0.8\\(8155\\)_en:*:*:*:*:*:*:*",
"matchCriteriaId": "113E1616-FA42-4085-B3FB-83655BB1859A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 V1.2.0.8(8155)_EN contains a Buffer Overflow vulnerability via the function fromSetIpBind."
},
{
"lang": "es",
"value": "Tenda FH1206 V1.2.0.8(8155)_EN contiene una vulnerabilidad de desbordamiento de b\u00fafer a trav\u00e9s de la funci\u00f3n fromSetIpBind."
}
],
"id": "CVE-2024-44386",
"lastModified": "2025-04-04T14:37:57.707",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.4,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-08-23T16:15:07.120",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Broken Link"
],
"url": "https://github.com/GroundCTL2MajorTom/pocs/blob/main/tenda_FH1206_buffer_overflow2.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-42985
Vulnerability from fkie_nvd - Published: 2024-08-15 17:15 - Updated: 2024-08-16 17:35
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromNatlimit function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromNatlimit.md | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh1206_firmware | v02.03.01.35 | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.01.35:*:*:*:*:*:*:*",
"matchCriteriaId": "6B880B95-84CF-4C01-B403-3E2F0686DCAF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromNatlimit function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
},
{
"lang": "es",
"value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n fromNatlimit. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
}
],
"id": "CVE-2024-42985",
"lastModified": "2024-08-16T17:35:10.400",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-08-15T17:15:21.623",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromNatlimit.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-42979
Vulnerability from fkie_nvd - Published: 2024-08-15 17:15 - Updated: 2024-08-16 18:11
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ProtForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh1206_firmware | 02.03.01.35 | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:02.03.01.35:*:*:*:*:*:*:*",
"matchCriteriaId": "5546734B-3297-4E57-95C6-52D7F6B44513",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ProtForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
},
{
"lang": "es",
"value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n frmL7ProtForm. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
}
],
"id": "CVE-2024-42979",
"lastModified": "2024-08-16T18:11:41.197",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-08-15T17:15:21.057",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit"
],
"url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/frmL7ProtForm.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-42980
Vulnerability from fkie_nvd - Published: 2024-08-15 17:15 - Updated: 2024-08-16 18:35
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ImForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/frmL7ImForm.md | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh1206_firmware | v02.03.01.35 | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.01.35:*:*:*:*:*:*:*",
"matchCriteriaId": "6B880B95-84CF-4C01-B403-3E2F0686DCAF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the frmL7ImForm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
},
{
"lang": "es",
"value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n frmL7ImForm. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
}
],
"id": "CVE-2024-42980",
"lastModified": "2024-08-16T18:35:15.747",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-08-15T17:15:21.147",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/frmL7ImForm.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-400"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-42986
Vulnerability from fkie_nvd - Published: 2024-08-15 17:15 - Updated: 2024-10-24 20:35
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the PPPOEPassword parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromAdvSetWan_PPPOEPassword.md | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh1206_firmware | v02.03.1.35 | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.1.35:*:*:*:*:*:*:*",
"matchCriteriaId": "2C2999F9-532B-40F6-8E72-E401ABA309F0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the PPPOEPassword parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
},
{
"lang": "es",
"value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro PPPOEPassword en la funci\u00f3n fromAdvSetWan. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
}
],
"id": "CVE-2024-42986",
"lastModified": "2024-10-24T20:35:09.653",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-08-15T17:15:21.717",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromAdvSetWan_PPPOEPassword.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-42984
Vulnerability from fkie_nvd - Published: 2024-08-15 17:15 - Updated: 2024-08-16 18:10
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromP2pListFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh1206_firmware | 02.03.01.35 | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:02.03.01.35:*:*:*:*:*:*:*",
"matchCriteriaId": "5546734B-3297-4E57-95C6-52D7F6B44513",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromP2pListFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
},
{
"lang": "es",
"value": "Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n fromP2pListFilter. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
}
],
"id": "CVE-2024-42984",
"lastModified": "2024-08-16T18:10:53.680",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-08-15T17:15:21.523",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit"
],
"url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromP2pListFilter.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-42981
Vulnerability from fkie_nvd - Published: 2024-08-15 17:15 - Updated: 2024-08-16 18:35
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the delno parameter in the fromPptpUserSetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromPptpUserSetting.md | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh1206_firmware | v02.03.01.35 | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.01.35:*:*:*:*:*:*:*",
"matchCriteriaId": "6B880B95-84CF-4C01-B403-3E2F0686DCAF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the delno parameter in the fromPptpUserSetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
},
{
"lang": "es",
"value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro delno en la funci\u00f3n fromPptpUserSetting. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
}
],
"id": "CVE-2024-42981",
"lastModified": "2024-08-16T18:35:16.483",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-08-15T17:15:21.240",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromPptpUserSetting.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-400"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-42983
Vulnerability from fkie_nvd - Published: 2024-08-15 17:15 - Updated: 2024-08-16 18:11
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the pptpPPW parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh1206_firmware | 02.03.01.35 | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:02.03.01.35:*:*:*:*:*:*:*",
"matchCriteriaId": "5546734B-3297-4E57-95C6-52D7F6B44513",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the pptpPPW parameter in the fromAdvSetWan function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
},
{
"lang": "es",
"value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro pptpPPW en la funci\u00f3n fromAdvSetWan. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
}
],
"id": "CVE-2024-42983",
"lastModified": "2024-08-16T18:11:08.020",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-08-15T17:15:21.433",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit"
],
"url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromAdvSetWan_pptpPPW.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-42987
Vulnerability from fkie_nvd - Published: 2024-08-15 17:15 - Updated: 2025-09-02 17:15
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack-based buffer overflow vulnerability in the fromPptpUserAdd function. The vulnerability can be triggered via the modino, username, newpwd, or pptpdnetseg parameters, all of which are passed via HTTP POST and used in unsafe sprintf calls without proper length validation. A remote attacker can exploit this flaw through a crafted POST request, which may cause a Denial of Service (DoS). In certain scenarios, this issue could potentially be leveraged to achieve remote code execution.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh1206_firmware | v02.03.1.35 | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.1.35:*:*:*:*:*:*:*",
"matchCriteriaId": "2C2999F9-532B-40F6-8E72-E401ABA309F0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack-based buffer overflow vulnerability in the fromPptpUserAdd function. The vulnerability can be triggered via the modino, username, newpwd, or pptpdnetseg parameters, all of which are passed via HTTP POST and used in unsafe sprintf calls without proper length validation. A remote attacker can exploit this flaw through a crafted POST request, which may cause a Denial of Service (DoS). In certain scenarios, this issue could potentially be leveraged to achieve remote code execution."
},
{
"lang": "es",
"value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro modino en la funci\u00f3n fromPptpUserAdd. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
}
],
"id": "CVE-2024-42987",
"lastModified": "2025-09-02T17:15:34.390",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-08-15T17:15:21.820",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromPptpUserAdd.md"
},
{
"source": "cve@mitre.org",
"url": "https://github.com/laohouzju/PoC/blob/main/Tenda%20FH1206%20fromPptpUserAdd_newpwd.md"
},
{
"source": "cve@mitre.org",
"url": "https://github.com/laohouzju/PoC/blob/main/Tenda%20FH1206%20fromPptpUserAdd_pptpdnetseg.md"
},
{
"source": "cve@mitre.org",
"url": "https://github.com/laohouzju/PoC/blob/main/Tenda%20FH1206%20fromPptpUserAdd_username.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-42982
Vulnerability from fkie_nvd - Published: 2024-08-15 17:15 - Updated: 2024-08-16 14:35
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
5.3 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromVirtualSer.md | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh1206_firmware | v02.03.01.35 | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.01.35:*:*:*:*:*:*:*",
"matchCriteriaId": "6B880B95-84CF-4C01-B403-3E2F0686DCAF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromVirtualSer function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
},
{
"lang": "es",
"value": "Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n fromVirtualSer. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
}
],
"id": "CVE-2024-42982",
"lastModified": "2024-08-16T14:35:03.793",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-08-15T17:15:21.337",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromVirtualSer.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-42977
Vulnerability from fkie_nvd - Published: 2024-08-15 17:15 - Updated: 2024-10-24 20:35
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the qos parameter in the fromqossetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromqossetting_qos.md | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh1206_firmware | v02.03.01.35 | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.01.35:*:*:*:*:*:*:*",
"matchCriteriaId": "6B880B95-84CF-4C01-B403-3E2F0686DCAF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the qos parameter in the fromqossetting function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
},
{
"lang": "es",
"value": "Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro qos en la funci\u00f3n fromqossetting. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
}
],
"id": "CVE-2024-42977",
"lastModified": "2024-10-24T20:35:08.860",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-08-15T17:15:20.860",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromqossetting_qos.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-42973
Vulnerability from fkie_nvd - Published: 2024-08-15 17:15 - Updated: 2024-08-16 18:11
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSetlpBind function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh1206_firmware | 02.03.01.35 | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:02.03.01.35:*:*:*:*:*:*:*",
"matchCriteriaId": "5546734B-3297-4E57-95C6-52D7F6B44513",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSetlpBind function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
},
{
"lang": "es",
"value": "Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n fromSetlpBind. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
}
],
"id": "CVE-2024-42973",
"lastModified": "2024-08-16T18:11:51.570",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-08-15T17:15:20.573",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit"
],
"url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromSetIpBind.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-42978
Vulnerability from fkie_nvd - Published: 2024-08-15 17:15 - Updated: 2025-03-25 17:16
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
An issue in the handler function in /goform/telnet of Tenda FH1206 v02.03.01.35 allows attackers to execute arbitrary commands via a crafted HTTP request.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/telnet.md | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh1206_firmware | v02.03.01.35 | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.01.35:*:*:*:*:*:*:*",
"matchCriteriaId": "6B880B95-84CF-4C01-B403-3E2F0686DCAF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue in the handler function in /goform/telnet of Tenda FH1206 v02.03.01.35 allows attackers to execute arbitrary commands via a crafted HTTP request."
},
{
"lang": "es",
"value": " Un problema en la funci\u00f3n de controlador en /goform/telnet de Tenda FH1206 v02.03.01.35 permite a los atacantes ejecutar comandos arbitrarios a trav\u00e9s de una solicitud HTTP manipulada."
}
],
"id": "CVE-2024-42978",
"lastModified": "2025-03-25T17:16:04.710",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-08-15T17:15:20.960",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/telnet.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-42974
Vulnerability from fkie_nvd - Published: 2024-08-15 17:15 - Updated: 2024-08-16 18:11
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromwebExcptypemanFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh1206_firmware | 02.03.01.35 | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:02.03.01.35:*:*:*:*:*:*:*",
"matchCriteriaId": "5546734B-3297-4E57-95C6-52D7F6B44513",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromwebExcptypemanFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
},
{
"lang": "es",
"value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n fromwebExcptypemanFilter. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
}
],
"id": "CVE-2024-42974",
"lastModified": "2024-08-16T18:11:47.980",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-08-15T17:15:20.667",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit"
],
"url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromwebExcptypemanFilter.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-42976
Vulnerability from fkie_nvd - Published: 2024-08-15 17:15 - Updated: 2024-08-16 17:35
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromSafeClientFilter_page.md | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh1206_firmware | v02.03.01.35 | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.01.35:*:*:*:*:*:*:*",
"matchCriteriaId": "6B880B95-84CF-4C01-B403-3E2F0686DCAF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSafeClientFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
},
{
"lang": "es",
"value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n fromSafeClientFilter. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
}
],
"id": "CVE-2024-42976",
"lastModified": "2024-08-16T17:35:09.687",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-08-15T17:15:20.767",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromSafeClientFilter_page.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-42969
Vulnerability from fkie_nvd - Published: 2024-08-15 17:15 - Updated: 2024-08-16 18:35
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSafeUrlFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromSafeMacFilter%20_page.md | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh1206_firmware | v02.03.01.35 | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:v02.03.01.35:*:*:*:*:*:*:*",
"matchCriteriaId": "6B880B95-84CF-4C01-B403-3E2F0686DCAF",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the page parameter in the fromSafeUrlFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
},
{
"lang": "es",
"value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro page en la funci\u00f3n fromSafeUrlFilter. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
}
],
"id": "CVE-2024-42969",
"lastModified": "2024-08-16T18:35:15.027",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-08-15T17:15:20.480",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromSafeMacFilter%20_page.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-400"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
FKIE_CVE-2024-42968
Vulnerability from fkie_nvd - Published: 2024-08-15 17:15 - Updated: 2024-08-16 18:14
Severity ?
7.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
6.5 (Medium) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Summary
Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the Go parameter in the fromSafeUrlFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tenda | fh1206_firmware | 02.03.01.35 | |
| tenda | fh1206 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tenda:fh1206_firmware:02.03.01.35:*:*:*:*:*:*:*",
"matchCriteriaId": "5546734B-3297-4E57-95C6-52D7F6B44513",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tenda:fh1206:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1412759D-05ED-4D6C-93C3-FE59F6A1490E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda FH1206 v02.03.01.35 was discovered to contain a stack overflow via the Go parameter in the fromSafeUrlFilter function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted POST request."
},
{
"lang": "es",
"value": " Se descubri\u00f3 que Tenda FH1206 v02.03.01.35 conten\u00eda un desbordamiento de pila a trav\u00e9s del par\u00e1metro Go en la funci\u00f3n fromSafeUrlFilter. Esta vulnerabilidad permite a los atacantes provocar una denegaci\u00f3n de servicio (DoS) mediante una solicitud POST manipulada."
}
],
"id": "CVE-2024-42968",
"lastModified": "2024-08-16T18:14:39.303",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2024-08-15T17:15:20.373",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit"
],
"url": "https://github.com/TTTJJJWWW/AHU-IoT-vulnerable/blob/main/Tenda/FH1206/fromSafeMacFilter_Go.md"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",