Search criteria
21 vulnerabilities found for ht802_firmware by grandstream
FKIE_CVE-2020-5762
Vulnerability from fkie_nvd - Published: 2020-07-29 19:15 - Updated: 2024-11-21 05:34
Severity ?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field.
References
| URL | Tags | ||
|---|---|---|---|
| vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2020-43 | Exploit, Third Party Advisory | |
| vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2020-47 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2020-43 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2020-47 | Third Party Advisory, VDB Entry |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| grandstream | ht801_firmware | * | |
| grandstream | ht801 | - | |
| grandstream | ht802_firmware | * | |
| grandstream | ht802 | - | |
| grandstream | ht812_firmware | * | |
| grandstream | ht812 | - | |
| grandstream | ht814_firmware | * | |
| grandstream | ht814 | - | |
| grandstream | ht818_firmware | * | |
| grandstream | ht818 | - | |
| grandstream | ht813_firmware | * | |
| grandstream | ht813 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht801_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "10C6AE2E-DCBA-471E-AC05-D04021F625CE",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht801:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1338EDFF-1D52-41E1-9378-7D752E622188",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht802_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1EE48BC4-31F0-4D94-9A1E-C0E83776FDF4",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht802:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A44D9054-2A04-4A48-A270-4B56CD8BA7DD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht812_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CF548C51-32DF-4365-9C36-CE1FE17AC207",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht812:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AC0A2572-951D-4384-AF93-D674F3E07788",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht814_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "59773485-3A12-477B-BF83-C1E0E8C979AD",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht814:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE769C28-17BB-4570-8239-6393239BE542",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht818_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0CBC4277-2D62-4C60-A638-851BB92B9A67",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht818:-:*:*:*:*:*:*:*",
"matchCriteriaId": "35BEAB2F-5673-42EC-BA4F-982226C1CB7E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht813_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C9E5F102-13D3-47A4-926A-4B67E0742E82",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht813:-:*:*:*:*:*:*:*",
"matchCriteriaId": "76348549-9B8E-4E80-854F-8F8886C6BA59",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field."
},
{
"lang": "es",
"value": "Grandstream serie HT800 versiones de firmware 1.0.17.5 y posteriores, es vulnerable a un ataque de denegaci\u00f3n de servicio contra el servicio TR-069. Un atacante remoto no autenticado puede detener el servicio debido a una desreferencia del puntero NULL en el servicio TR-069. Esta condici\u00f3n es desencadenada debido a un manejo inapropiado del campo Authentication HTTP"
}
],
"id": "CVE-2020-5762",
"lastModified": "2024-11-21T05:34:33.477",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-07-29T19:15:15.123",
"references": [
{
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"source": "vulnreport@tenable.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"sourceIdentifier": "vulnreport@tenable.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-476"
}
],
"source": "vulnreport@tenable.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-476"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-5763
Vulnerability from fkie_nvd - Published: 2020-07-29 19:15 - Updated: 2024-11-21 05:34
Severity ?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt.
References
| URL | Tags | ||
|---|---|---|---|
| vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2020-43 | Exploit, Third Party Advisory | |
| vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2020-47 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2020-43 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2020-47 | Third Party Advisory, VDB Entry |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| grandstream | ht801_firmware | * | |
| grandstream | ht801 | - | |
| grandstream | ht802_firmware | * | |
| grandstream | ht802 | - | |
| grandstream | ht812_firmware | * | |
| grandstream | ht812 | - | |
| grandstream | ht814_firmware | * | |
| grandstream | ht814 | - | |
| grandstream | ht818_firmware | * | |
| grandstream | ht818 | - | |
| grandstream | ht813_firmware | * | |
| grandstream | ht813 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht801_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "10C6AE2E-DCBA-471E-AC05-D04021F625CE",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht801:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1338EDFF-1D52-41E1-9378-7D752E622188",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht802_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1EE48BC4-31F0-4D94-9A1E-C0E83776FDF4",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht802:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A44D9054-2A04-4A48-A270-4B56CD8BA7DD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht812_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CF548C51-32DF-4365-9C36-CE1FE17AC207",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht812:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AC0A2572-951D-4384-AF93-D674F3E07788",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht814_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "59773485-3A12-477B-BF83-C1E0E8C979AD",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht814:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE769C28-17BB-4570-8239-6393239BE542",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht818_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0CBC4277-2D62-4C60-A638-851BB92B9A67",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht818:-:*:*:*:*:*:*:*",
"matchCriteriaId": "35BEAB2F-5673-42EC-BA4F-982226C1CB7E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht813_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C9E5F102-13D3-47A4-926A-4B67E0742E82",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht813:-:*:*:*:*:*:*:*",
"matchCriteriaId": "76348549-9B8E-4E80-854F-8F8886C6BA59",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt."
},
{
"lang": "es",
"value": "Grandstream serie HT800 versiones de firmware 1.0.17.5 y posteriores, contiene una backdoor en el servicio SSH. Un atacante remoto autenticado puede obtener un root shell cuando responde correctamente una petici\u00f3n de desaf\u00edo"
}
],
"id": "CVE-2020-5763",
"lastModified": "2024-11-21T05:34:33.593",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-07-29T19:15:15.200",
"references": [
{
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"source": "vulnreport@tenable.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"sourceIdentifier": "vulnreport@tenable.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-489"
}
],
"source": "vulnreport@tenable.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-326"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-5761
Vulnerability from fkie_nvd - Published: 2020-07-29 19:15 - Updated: 2024-11-21 05:34
Severity ?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service.
References
| URL | Tags | ||
|---|---|---|---|
| vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2020-43 | Exploit, Third Party Advisory | |
| vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2020-47 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2020-43 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2020-47 | Third Party Advisory, VDB Entry |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| grandstream | ht801_firmware | * | |
| grandstream | ht801 | - | |
| grandstream | ht802_firmware | * | |
| grandstream | ht802 | - | |
| grandstream | ht812_firmware | * | |
| grandstream | ht812 | - | |
| grandstream | ht814_firmware | * | |
| grandstream | ht814 | - | |
| grandstream | ht818_firmware | * | |
| grandstream | ht818 | - | |
| grandstream | ht813_firmware | * | |
| grandstream | ht813 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht801_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "10C6AE2E-DCBA-471E-AC05-D04021F625CE",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht801:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1338EDFF-1D52-41E1-9378-7D752E622188",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht802_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1EE48BC4-31F0-4D94-9A1E-C0E83776FDF4",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht802:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A44D9054-2A04-4A48-A270-4B56CD8BA7DD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht812_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CF548C51-32DF-4365-9C36-CE1FE17AC207",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht812:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AC0A2572-951D-4384-AF93-D674F3E07788",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht814_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "59773485-3A12-477B-BF83-C1E0E8C979AD",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht814:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE769C28-17BB-4570-8239-6393239BE542",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht818_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0CBC4277-2D62-4C60-A638-851BB92B9A67",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht818:-:*:*:*:*:*:*:*",
"matchCriteriaId": "35BEAB2F-5673-42EC-BA4F-982226C1CB7E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht813_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C9E5F102-13D3-47A4-926A-4B67E0742E82",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht813:-:*:*:*:*:*:*:*",
"matchCriteriaId": "76348549-9B8E-4E80-854F-8F8886C6BA59",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
},
{
"lang": "es",
"value": "Grandstream serie HT800 versiones de firmware 1.0.17.5 y posteriores, es vulnerable a un agotamiento del CPU debido a un bucle infinito en el servicio TR-069. Los atacantes remotos no autenticados pueden activar este caso mediante el env\u00edo de un mensaje TCP de un car\u00e1cter hacia el servicio TR-069"
}
],
"id": "CVE-2020-5761",
"lastModified": "2024-11-21T05:34:33.363",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-07-29T19:15:15.047",
"references": [
{
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"source": "vulnreport@tenable.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"sourceIdentifier": "vulnreport@tenable.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-835"
}
],
"source": "vulnreport@tenable.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-835"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-5760
Vulnerability from fkie_nvd - Published: 2020-07-29 19:15 - Updated: 2024-11-21 05:34
Severity ?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message.
References
| URL | Tags | ||
|---|---|---|---|
| vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2020-43 | Exploit, Third Party Advisory | |
| vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2020-47 | Third Party Advisory, VDB Entry | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2020-43 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2020-47 | Third Party Advisory, VDB Entry |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| grandstream | ht801_firmware | * | |
| grandstream | ht801 | - | |
| grandstream | ht802_firmware | * | |
| grandstream | ht802 | - | |
| grandstream | ht812_firmware | * | |
| grandstream | ht812 | - | |
| grandstream | ht814_firmware | * | |
| grandstream | ht814 | - | |
| grandstream | ht818_firmware | * | |
| grandstream | ht818 | - | |
| grandstream | ht813_firmware | * | |
| grandstream | ht813 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht801_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "10C6AE2E-DCBA-471E-AC05-D04021F625CE",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht801:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1338EDFF-1D52-41E1-9378-7D752E622188",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht802_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1EE48BC4-31F0-4D94-9A1E-C0E83776FDF4",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht802:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A44D9054-2A04-4A48-A270-4B56CD8BA7DD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht812_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CF548C51-32DF-4365-9C36-CE1FE17AC207",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht812:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AC0A2572-951D-4384-AF93-D674F3E07788",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht814_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "59773485-3A12-477B-BF83-C1E0E8C979AD",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht814:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE769C28-17BB-4570-8239-6393239BE542",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht818_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0CBC4277-2D62-4C60-A638-851BB92B9A67",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht818:-:*:*:*:*:*:*:*",
"matchCriteriaId": "35BEAB2F-5673-42EC-BA4F-982226C1CB7E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht813_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C9E5F102-13D3-47A4-926A-4B67E0742E82",
"versionEndIncluding": "1.0.17.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht813:-:*:*:*:*:*:*:*",
"matchCriteriaId": "76348549-9B8E-4E80-854F-8F8886C6BA59",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message."
},
{
"lang": "es",
"value": "Grandstream serie HT800 versiones de firmware 1.0.17.5 y posteriores, es susceptible a una vulnerabilidad de inyecci\u00f3n de comandos del Sistema Operativo. Los atacantes remotos no autenticados pueden ejecutar comandos arbitrarios como root mediante el dise\u00f1o de un archivo de configuraci\u00f3n especial y enviado a un mensaje SIP dise\u00f1ado"
}
],
"id": "CVE-2020-5760",
"lastModified": "2024-11-21T05:34:33.240",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-07-29T19:15:14.967",
"references": [
{
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"source": "vulnreport@tenable.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"sourceIdentifier": "vulnreport@tenable.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "vulnreport@tenable.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2017-16565
Vulnerability from fkie_nvd - Published: 2017-11-06 08:29 - Updated: 2025-04-20 01:37
Severity ?
Summary
Cross-Site Request Forgery (CSRF) in /cgi-bin/login on Vonage (Grandstream) HT802 devices allows attackers to authenticate a user via the login screen using the default password of 123 and submit arbitrary requests.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/ | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/ | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| grandstream | ht802_firmware | - | |
| grandstream | ht802 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht802_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6F3D7120-1595-4888-BEE7-021931C3AEB5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht802:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A44D9054-2A04-4A48-A270-4B56CD8BA7DD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Cross-Site Request Forgery (CSRF) in /cgi-bin/login on Vonage (Grandstream) HT802 devices allows attackers to authenticate a user via the login screen using the default password of 123 and submit arbitrary requests."
},
{
"lang": "es",
"value": "Cross-Site Request Forgery (CSRF) en /cgi-bin/login en dispositivos Vonage (Grandstream) HT802 permite que atacantes autentiquen a un usuario mediante la pantalla de login empleando la contrase\u00f1a por defecto 123 y enviando peticiones arbitrarias."
}
],
"id": "CVE-2017-16565",
"lastModified": "2025-04-20T01:37:25.860",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2017-11-06T08:29:00.313",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-352"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2017-16564
Vulnerability from fkie_nvd - Published: 2017-11-06 08:29 - Updated: 2025-04-20 01:37
Severity ?
Summary
Stored Cross-site scripting (XSS) vulnerability in /cgi-bin/config2 on Vonage (Grandstream) HT802 devices allows remote authenticated users to inject arbitrary web script or HTML via the DHCP vendor class ID field (P148).
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/ | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/ | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| grandstream | ht802_firmware | - | |
| grandstream | ht802 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht802_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6F3D7120-1595-4888-BEE7-021931C3AEB5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht802:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A44D9054-2A04-4A48-A270-4B56CD8BA7DD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Stored Cross-site scripting (XSS) vulnerability in /cgi-bin/config2 on Vonage (Grandstream) HT802 devices allows remote authenticated users to inject arbitrary web script or HTML via the DHCP vendor class ID field (P148)."
},
{
"lang": "es",
"value": "Una vulnerabilidad de Cross-Site Scripting (XSS) persistente en /cgi-bin/config2 en dispositivos Vonage (Grandstream) HT802 permite que usuarios remotos autenticados inyecten scripts web o HTML arbitrarios mediante el campo ID de clase de proveedor DHCP (P148)."
}
],
"id": "CVE-2017-16564",
"lastModified": "2025-04-20T01:37:25.860",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
},
"exploitabilityScore": 2.3,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2017-11-06T08:29:00.283",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2017-16563
Vulnerability from fkie_nvd - Published: 2017-11-06 08:29 - Updated: 2025-04-20 01:37
Severity ?
Summary
Cross-Site Request Forgery (CSRF) in the Basic Settings screen on Vonage (Grandstream) HT802 devices allows attackers to modify settings, related to cgi-bin/update.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/ | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/ | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| grandstream | ht802_firmware | - | |
| grandstream | ht802 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:grandstream:ht802_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6F3D7120-1595-4888-BEE7-021931C3AEB5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:grandstream:ht802:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A44D9054-2A04-4A48-A270-4B56CD8BA7DD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Cross-Site Request Forgery (CSRF) in the Basic Settings screen on Vonage (Grandstream) HT802 devices allows attackers to modify settings, related to cgi-bin/update."
},
{
"lang": "es",
"value": "Cross-Site Request Forgery (CSRF) en la pantalla Basic Settings en dispositivos Vonage (Grandstream) HT802 permite que atacantes modifiquen la configuraci\u00f3n. Esto se relaciona con cgi-bin/update."
}
],
"id": "CVE-2017-16563",
"lastModified": "2025-04-20T01:37:25.860",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"exploitabilityScore": 2.1,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2017-11-06T08:29:00.253",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-352"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2020-5763 (GCVE-0-2020-5763)
Vulnerability from cvelistv5 – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
VLAI?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Grandstream HT800 Series |
Affected:
Versions 1.0.17.5 and below
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:39:25.821Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Grandstream HT800 Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Versions 1.0.17.5 and below"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-489",
"description": "CWE-489",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-29T19:06:11",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2020-5763",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Grandstream HT800 Series",
"version": {
"version_data": [
{
"version_value": "Versions 1.0.17.5 and below"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-489"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2020-43",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"name": "https://www.tenable.com/security/research/tra-2020-47",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2020-5763",
"datePublished": "2020-07-29T18:51:50",
"dateReserved": "2020-01-06T00:00:00",
"dateUpdated": "2024-08-04T08:39:25.821Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5762 (GCVE-0-2020-5762)
Vulnerability from cvelistv5 – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
VLAI?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Grandstream HT800 Series |
Affected:
Versions 1.0.17.5 and below
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:39:25.894Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Grandstream HT800 Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Versions 1.0.17.5 and below"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-29T19:06:10",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2020-5762",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Grandstream HT800 Series",
"version": {
"version_data": [
{
"version_value": "Versions 1.0.17.5 and below"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-476"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2020-43",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"name": "https://www.tenable.com/security/research/tra-2020-47",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2020-5762",
"datePublished": "2020-07-29T18:51:47",
"dateReserved": "2020-01-06T00:00:00",
"dateUpdated": "2024-08-04T08:39:25.894Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5761 (GCVE-0-2020-5761)
Vulnerability from cvelistv5 – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
VLAI?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Grandstream HT800 Series |
Affected:
Versions 1.0.17.5 and below
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:39:25.699Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Grandstream HT800 Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Versions 1.0.17.5 and below"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-835",
"description": "CWE-835",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-29T19:06:10",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2020-5761",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Grandstream HT800 Series",
"version": {
"version_data": [
{
"version_value": "Versions 1.0.17.5 and below"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-835"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2020-43",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"name": "https://www.tenable.com/security/research/tra-2020-47",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2020-5761",
"datePublished": "2020-07-29T18:51:43",
"dateReserved": "2020-01-06T00:00:00",
"dateUpdated": "2024-08-04T08:39:25.699Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5760 (GCVE-0-2020-5760)
Vulnerability from cvelistv5 – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
VLAI?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Grandstream HT800 Series |
Affected:
Versions 1.0.17.5 and below
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:39:25.853Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Grandstream HT800 Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Versions 1.0.17.5 and below"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-29T19:06:09",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2020-5760",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Grandstream HT800 Series",
"version": {
"version_data": [
{
"version_value": "Versions 1.0.17.5 and below"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-78"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2020-43",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"name": "https://www.tenable.com/security/research/tra-2020-47",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2020-5760",
"datePublished": "2020-07-29T18:51:40",
"dateReserved": "2020-01-06T00:00:00",
"dateUpdated": "2024-08-04T08:39:25.853Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-16563 (GCVE-0-2017-16563)
Vulnerability from cvelistv5 – Published: 2017-11-06 08:00 – Updated: 2024-08-05 20:27
VLAI?
Summary
Cross-Site Request Forgery (CSRF) in the Basic Settings screen on Vonage (Grandstream) HT802 devices allows attackers to modify settings, related to cgi-bin/update.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T20:27:04.056Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2017-11-06T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-Site Request Forgery (CSRF) in the Basic Settings screen on Vonage (Grandstream) HT802 devices allows attackers to modify settings, related to cgi-bin/update."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-11-06T08:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-16563",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-Site Request Forgery (CSRF) in the Basic Settings screen on Vonage (Grandstream) HT802 devices allows attackers to modify settings, related to cgi-bin/update."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/",
"refsource": "MISC",
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-16563",
"datePublished": "2017-11-06T08:00:00",
"dateReserved": "2017-11-06T00:00:00",
"dateUpdated": "2024-08-05T20:27:04.056Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-16564 (GCVE-0-2017-16564)
Vulnerability from cvelistv5 – Published: 2017-11-06 08:00 – Updated: 2024-08-05 20:27
VLAI?
Summary
Stored Cross-site scripting (XSS) vulnerability in /cgi-bin/config2 on Vonage (Grandstream) HT802 devices allows remote authenticated users to inject arbitrary web script or HTML via the DHCP vendor class ID field (P148).
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T20:27:04.127Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2017-11-06T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Stored Cross-site scripting (XSS) vulnerability in /cgi-bin/config2 on Vonage (Grandstream) HT802 devices allows remote authenticated users to inject arbitrary web script or HTML via the DHCP vendor class ID field (P148)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-11-06T08:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-16564",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Stored Cross-site scripting (XSS) vulnerability in /cgi-bin/config2 on Vonage (Grandstream) HT802 devices allows remote authenticated users to inject arbitrary web script or HTML via the DHCP vendor class ID field (P148)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/",
"refsource": "MISC",
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-16564",
"datePublished": "2017-11-06T08:00:00",
"dateReserved": "2017-11-06T00:00:00",
"dateUpdated": "2024-08-05T20:27:04.127Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-16565 (GCVE-0-2017-16565)
Vulnerability from cvelistv5 – Published: 2017-11-06 08:00 – Updated: 2024-08-05 20:27
VLAI?
Summary
Cross-Site Request Forgery (CSRF) in /cgi-bin/login on Vonage (Grandstream) HT802 devices allows attackers to authenticate a user via the login screen using the default password of 123 and submit arbitrary requests.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T20:27:04.097Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2017-11-06T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-Site Request Forgery (CSRF) in /cgi-bin/login on Vonage (Grandstream) HT802 devices allows attackers to authenticate a user via the login screen using the default password of 123 and submit arbitrary requests."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-11-06T08:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-16565",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-Site Request Forgery (CSRF) in /cgi-bin/login on Vonage (Grandstream) HT802 devices allows attackers to authenticate a user via the login screen using the default password of 123 and submit arbitrary requests."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/",
"refsource": "MISC",
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-16565",
"datePublished": "2017-11-06T08:00:00",
"dateReserved": "2017-11-06T00:00:00",
"dateUpdated": "2024-08-05T20:27:04.097Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5763 (GCVE-0-2020-5763)
Vulnerability from nvd – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
VLAI?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Grandstream HT800 Series |
Affected:
Versions 1.0.17.5 and below
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:39:25.821Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Grandstream HT800 Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Versions 1.0.17.5 and below"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-489",
"description": "CWE-489",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-29T19:06:11",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2020-5763",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Grandstream HT800 Series",
"version": {
"version_data": [
{
"version_value": "Versions 1.0.17.5 and below"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below contain a backdoor in the SSH service. An authenticated remote attacker can obtain a root shell by correctly answering a challenge prompt."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-489"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2020-43",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"name": "https://www.tenable.com/security/research/tra-2020-47",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2020-5763",
"datePublished": "2020-07-29T18:51:50",
"dateReserved": "2020-01-06T00:00:00",
"dateUpdated": "2024-08-04T08:39:25.821Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5762 (GCVE-0-2020-5762)
Vulnerability from nvd – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
VLAI?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Grandstream HT800 Series |
Affected:
Versions 1.0.17.5 and below
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:39:25.894Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Grandstream HT800 Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Versions 1.0.17.5 and below"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-476",
"description": "CWE-476",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-29T19:06:10",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2020-5762",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Grandstream HT800 Series",
"version": {
"version_data": [
{
"version_value": "Versions 1.0.17.5 and below"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to a denial of service attack against the TR-069 service. An unauthenticated remote attacker can stop the service due to a NULL pointer dereference in the TR-069 service. This condition is triggered due to mishandling of the HTTP Authentication field."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-476"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2020-43",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"name": "https://www.tenable.com/security/research/tra-2020-47",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2020-5762",
"datePublished": "2020-07-29T18:51:47",
"dateReserved": "2020-01-06T00:00:00",
"dateUpdated": "2024-08-04T08:39:25.894Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5761 (GCVE-0-2020-5761)
Vulnerability from nvd – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
VLAI?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Grandstream HT800 Series |
Affected:
Versions 1.0.17.5 and below
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:39:25.699Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Grandstream HT800 Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Versions 1.0.17.5 and below"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-835",
"description": "CWE-835",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-29T19:06:10",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2020-5761",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Grandstream HT800 Series",
"version": {
"version_data": [
{
"version_value": "Versions 1.0.17.5 and below"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to CPU exhaustion due to an infinite loop in the TR-069 service. Unauthenticated remote attackers can trigger this case by sending a one character TCP message to the TR-069 service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-835"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2020-43",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"name": "https://www.tenable.com/security/research/tra-2020-47",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2020-5761",
"datePublished": "2020-07-29T18:51:43",
"dateReserved": "2020-01-06T00:00:00",
"dateUpdated": "2024-08-04T08:39:25.699Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5760 (GCVE-0-2020-5760)
Vulnerability from nvd – Published: 2020-07-29 18:51 – Updated: 2024-08-04 08:39
VLAI?
Summary
Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message.
Severity ?
No CVSS data available.
CWE
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Grandstream HT800 Series |
Affected:
Versions 1.0.17.5 and below
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:39:25.853Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Grandstream HT800 Series",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Versions 1.0.17.5 and below"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-29T19:06:09",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2020-5760",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Grandstream HT800 Series",
"version": {
"version_data": [
{
"version_value": "Versions 1.0.17.5 and below"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Grandstream HT800 series firmware version 1.0.17.5 and below is vulnerable to an OS command injection vulnerability. Unauthenticated remote attackers can execute arbitrary commands as root by crafting a special configuration file and sending a crafted SIP message."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-78"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2020-43",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-43"
},
{
"name": "https://www.tenable.com/security/research/tra-2020-47",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2020-47"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2020-5760",
"datePublished": "2020-07-29T18:51:40",
"dateReserved": "2020-01-06T00:00:00",
"dateUpdated": "2024-08-04T08:39:25.853Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-16563 (GCVE-0-2017-16563)
Vulnerability from nvd – Published: 2017-11-06 08:00 – Updated: 2024-08-05 20:27
VLAI?
Summary
Cross-Site Request Forgery (CSRF) in the Basic Settings screen on Vonage (Grandstream) HT802 devices allows attackers to modify settings, related to cgi-bin/update.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T20:27:04.056Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2017-11-06T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-Site Request Forgery (CSRF) in the Basic Settings screen on Vonage (Grandstream) HT802 devices allows attackers to modify settings, related to cgi-bin/update."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-11-06T08:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-16563",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-Site Request Forgery (CSRF) in the Basic Settings screen on Vonage (Grandstream) HT802 devices allows attackers to modify settings, related to cgi-bin/update."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/",
"refsource": "MISC",
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-16563",
"datePublished": "2017-11-06T08:00:00",
"dateReserved": "2017-11-06T00:00:00",
"dateUpdated": "2024-08-05T20:27:04.056Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-16564 (GCVE-0-2017-16564)
Vulnerability from nvd – Published: 2017-11-06 08:00 – Updated: 2024-08-05 20:27
VLAI?
Summary
Stored Cross-site scripting (XSS) vulnerability in /cgi-bin/config2 on Vonage (Grandstream) HT802 devices allows remote authenticated users to inject arbitrary web script or HTML via the DHCP vendor class ID field (P148).
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T20:27:04.127Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2017-11-06T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Stored Cross-site scripting (XSS) vulnerability in /cgi-bin/config2 on Vonage (Grandstream) HT802 devices allows remote authenticated users to inject arbitrary web script or HTML via the DHCP vendor class ID field (P148)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-11-06T08:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-16564",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Stored Cross-site scripting (XSS) vulnerability in /cgi-bin/config2 on Vonage (Grandstream) HT802 devices allows remote authenticated users to inject arbitrary web script or HTML via the DHCP vendor class ID field (P148)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/",
"refsource": "MISC",
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-16564",
"datePublished": "2017-11-06T08:00:00",
"dateReserved": "2017-11-06T00:00:00",
"dateUpdated": "2024-08-05T20:27:04.127Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-16565 (GCVE-0-2017-16565)
Vulnerability from nvd – Published: 2017-11-06 08:00 – Updated: 2024-08-05 20:27
VLAI?
Summary
Cross-Site Request Forgery (CSRF) in /cgi-bin/login on Vonage (Grandstream) HT802 devices allows attackers to authenticate a user via the login screen using the default password of 123 and submit arbitrary requests.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T20:27:04.097Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2017-11-06T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Cross-Site Request Forgery (CSRF) in /cgi-bin/login on Vonage (Grandstream) HT802 devices allows attackers to authenticate a user via the login screen using the default password of 123 and submit arbitrary requests."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-11-06T08:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-16565",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-Site Request Forgery (CSRF) in /cgi-bin/login on Vonage (Grandstream) HT802 devices allows attackers to authenticate a user via the login screen using the default password of 123 and submit arbitrary requests."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/",
"refsource": "MISC",
"url": "https://distributedcompute.com/2017/11/04/vonage-ht802-multiple-vulnerabilities/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-16565",
"datePublished": "2017-11-06T08:00:00",
"dateReserved": "2017-11-06T00:00:00",
"dateUpdated": "2024-08-05T20:27:04.097Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}