All the vulnerabilites related to Tenda - i21
cve-2022-44367
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:54:02.549Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/Double-q1015/CVE-vulns/blob/main/Tenda/i21/formSetUplinkInfo/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda i21 V1.0.0.14(4656) is vulnerable to Buffer Overflow via /goform/setUplinkInfo." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-02T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/Double-q1015/CVE-vulns/blob/main/Tenda/i21/formSetUplinkInfo/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-44367", "datePublished": "2022-12-02T00:00:00", "dateReserved": "2022-10-30T00:00:00", "dateUpdated": "2024-08-03T13:54:02.549Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-4491
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.263080 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.263080 | signature, permissions-required | |
https://vuldb.com/?submit.323600 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formGetDiagnoseInfo.md | exploit |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:i21:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "i21", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-4491", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-05-06T17:54:56.587542Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:53:03.754Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:40:47.383Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-263080 | Tenda i21 formGetDiagnoseInfo stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.263080" }, { "name": "VDB-263080 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.263080" }, { "name": "Submit #323600 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.323600" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formGetDiagnoseInfo.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "i21", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263080. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda i21 1.0.0.14(4656) wurde eine Schwachstelle entdeckt. Sie wurde als kritisch eingestuft. Es geht um die Funktion formGetDiagnoseInfo. Durch Manipulation des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-04T23:31:04.379Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-263080 | Tenda i21 formGetDiagnoseInfo stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.263080" }, { "name": "VDB-263080 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.263080" }, { "name": "Submit #323600 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.323600" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formGetDiagnoseInfo.md" } ], "timeline": [ { "lang": "en", "time": "2024-05-04T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-05-04T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-05-04T09:28:08.000Z", "value": "VulDB entry last update" } ], "title": "Tenda i21 formGetDiagnoseInfo stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-4491", "datePublished": "2024-05-04T23:31:04.379Z", "dateReserved": "2024-05-04T07:22:38.318Z", "dateUpdated": "2024-08-01T20:40:47.383Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-4492
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.263081 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.263081 | signature, permissions-required | |
https://vuldb.com/?submit.323601 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formOfflineSet.md | exploit |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-4492", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-05-06T14:39:38.498101Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:56:31.160Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:40:47.371Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-263081 | Tenda i21 setStaOffline formOfflineSet stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.263081" }, { "name": "VDB-263081 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.263081" }, { "name": "Submit #323601 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.323601" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formOfflineSet.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "i21", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). This issue affects the function formOfflineSet of the file /goform/setStaOffline. The manipulation of the argument GO/ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263081 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda i21 1.0.0.14(4656) entdeckt. Sie wurde als kritisch eingestuft. Es geht hierbei um die Funktion formOfflineSet der Datei /goform/setStaOffline. Mittels dem Manipulieren des Arguments GO/ssidIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-05T00:31:04.263Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-263081 | Tenda i21 setStaOffline formOfflineSet stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.263081" }, { "name": "VDB-263081 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.263081" }, { "name": "Submit #323601 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.323601" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formOfflineSet.md" } ], "timeline": [ { "lang": "en", "time": "2024-05-04T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-05-04T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-05-04T09:28:10.000Z", "value": "VulDB entry last update" } ], "title": "Tenda i21 setStaOffline formOfflineSet stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-4492", "datePublished": "2024-05-05T00:31:04.263Z", "dateReserved": "2024-05-04T07:22:41.382Z", "dateUpdated": "2024-08-01T20:40:47.371Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-4247
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.262138 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.262138 | signature, permissions-required | |
https://vuldb.com/?submit.319832 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formQosManage_auto.md | related |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:i21:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "i21", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-4247", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-04-29T16:10:23.729272Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:55:24.699Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:33:53.099Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-262138 | Tenda i21 formQosManage_auto stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.262138" }, { "name": "VDB-262138 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.262138" }, { "name": "Submit #319832 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.319832" }, { "tags": [ "related", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formQosManage_auto.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "i21", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. This vulnerability affects the function formQosManage_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. VDB-262138 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda i21 1.0.0.14(4656) wurde eine kritische Schwachstelle gefunden. Dabei geht es um die Funktion formQosManage_auto. Durch Manipulieren des Arguments ssidIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-27T09:31:04.549Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-262138 | Tenda i21 formQosManage_auto stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.262138" }, { "name": "VDB-262138 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.262138" }, { "name": "Submit #319832 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.319832" }, { "tags": [ "related" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formQosManage_auto.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-26T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-26T14:46:17.000Z", "value": "VulDB entry last update" } ], "title": "Tenda i21 formQosManage_auto stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-4247", "datePublished": "2024-04-27T09:31:04.549Z", "dateReserved": "2024-04-26T12:40:30.430Z", "dateUpdated": "2024-08-01T20:33:53.099Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-4250
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.262141 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.262141 | signature, permissions-required | |
https://vuldb.com/?submit.319835 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formwrlSSIDset.md | exploit |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:i21:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "i21", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-4250", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-05-01T15:33:49.309577Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:55:17.222Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:33:53.191Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-262141 | Tenda i21 wifiSSIDset formwrlSSIDset stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.262141" }, { "name": "VDB-262141 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.262141" }, { "name": "Submit #319835 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.319835" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formwrlSSIDset.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "i21", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_tu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. Affected by this vulnerability is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda i21 1.0.0.14(4656) wurde eine kritische Schwachstelle ausgemacht. Das betrifft die Funktion formwrlSSIDset der Datei /goform/wifiSSIDset. Dank der Manipulation des Arguments ssidIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-27T12:00:06.348Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-262141 | Tenda i21 wifiSSIDset formwrlSSIDset stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.262141" }, { "name": "VDB-262141 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.262141" }, { "name": "Submit #319835 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.319835" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formwrlSSIDset.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-26T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-26T14:46:24.000Z", "value": "VulDB entry last update" } ], "title": "Tenda i21 wifiSSIDset formwrlSSIDset stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-4250", "datePublished": "2024-04-27T12:00:06.348Z", "dateReserved": "2024-04-26T12:40:39.719Z", "dateUpdated": "2024-08-01T20:33:53.191Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-4496
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.263085 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.263085 | signature, permissions-required | |
https://vuldb.com/?submit.323606 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formWifiMacFilterSet.md | exploit |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-4496", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-05-06T14:38:56.608399Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:54:30.893Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:40:47.348Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-263085 | Tenda i21 formWifiMacFilterSet stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.263085" }, { "name": "VDB-263085 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.263085" }, { "name": "Submit #323606 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.323606" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formWifiMacFilterSet.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "i21", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263085 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine Schwachstelle in Tenda i21 1.0.0.14(4656) ausgemacht. Sie wurde als kritisch eingestuft. Es betrifft die Funktion formWifiMacFilterSet. Durch das Beeinflussen des Arguments ssidIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-05T06:00:06.060Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-263085 | Tenda i21 formWifiMacFilterSet stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.263085" }, { "name": "VDB-263085 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.263085" }, { "name": "Submit #323606 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.323606" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formWifiMacFilterSet.md" } ], "timeline": [ { "lang": "en", "time": "2024-05-04T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-05-04T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-05-04T09:28:16.000Z", "value": "VulDB entry last update" } ], "title": "Tenda i21 formWifiMacFilterSet stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-4496", "datePublished": "2024-05-05T06:00:06.060Z", "dateReserved": "2024-05-04T07:22:52.322Z", "dateUpdated": "2024-08-01T20:40:47.348Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-4495
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.263084 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.263084 | signature, permissions-required | |
https://vuldb.com/?submit.323605 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formWifiMacFilterGet.md | exploit |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:i21:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "i21", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-4495", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-07-18T15:04:25.270709Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-18T15:18:48.677Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:40:47.362Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-263084 | Tenda i21 formWifiMacFilterGet stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.263084" }, { "name": "VDB-263084 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.263084" }, { "name": "Submit #323605 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.323605" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formWifiMacFilterGet.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "i21", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263084. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine Schwachstelle wurde in Tenda i21 1.0.0.14(4656) gefunden. Sie wurde als kritisch eingestuft. Hierbei geht es um die Funktion formWifiMacFilterGet. Durch Manipulieren des Arguments index mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-05T05:31:04.418Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-263084 | Tenda i21 formWifiMacFilterGet stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.263084" }, { "name": "VDB-263084 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.263084" }, { "name": "Submit #323605 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.323605" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formWifiMacFilterGet.md" } ], "timeline": [ { "lang": "en", "time": "2024-05-04T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-05-04T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-05-04T09:28:14.000Z", "value": "VulDB entry last update" } ], "title": "Tenda i21 formWifiMacFilterGet stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-4495", "datePublished": "2024-05-05T05:31:04.418Z", "dateReserved": "2024-05-04T07:22:49.401Z", "dateUpdated": "2024-08-01T20:40:47.362Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-4497
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.263086 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.263086 | signature, permissions-required | |
https://vuldb.com/?submit.323607 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formexeCommand.md | exploit |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:i21:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "i21", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-4497", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-05-13T17:30:23.578110Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:54:14.378Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:40:47.441Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-263086 | Tenda i21 formexeCommand stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.263086" }, { "name": "VDB-263086 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.263086" }, { "name": "Submit #323607 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.323607" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formexeCommand.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "i21", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda i21 1.0.0.14(4656) wurde eine Schwachstelle ausgemacht. Sie wurde als kritisch eingestuft. Das betrifft die Funktion formexeCommand. Durch Beeinflussen des Arguments cmdinput mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-05T06:31:04.218Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-263086 | Tenda i21 formexeCommand stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.263086" }, { "name": "VDB-263086 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.263086" }, { "name": "Submit #323607 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.323607" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formexeCommand.md" } ], "timeline": [ { "lang": "en", "time": "2024-05-04T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-05-04T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-05-04T09:28:18.000Z", "value": "VulDB entry last update" } ], "title": "Tenda i21 formexeCommand stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-4497", "datePublished": "2024-05-05T06:31:04.218Z", "dateReserved": "2024-05-04T07:22:55.421Z", "dateUpdated": "2024-08-01T20:40:47.441Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-4494
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.263083 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.263083 | signature, permissions-required | |
https://vuldb.com/?submit.323604 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formSetUplinkInfo.md | exploit |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-4494", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "partial" } ], "role": "CISA Coordinator", "timestamp": "2024-05-06T20:47:31.722060Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:55:22.771Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:40:47.334Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-263083 | Tenda i21 setUplinkInfo formSetUplinkInfo stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.263083" }, { "name": "VDB-263083 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.263083" }, { "name": "Submit #323604 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.323604" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formSetUplinkInfo.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "i21", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263083. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "In Tenda i21 1.0.0.14(4656) wurde eine Schwachstelle gefunden. Sie wurde als kritisch eingestuft. Dabei geht es um die Funktion formSetUplinkInfo der Datei /goform/setUplinkInfo. Durch das Manipulieren des Arguments pingHostIp2 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Die Umsetzung des Angriffs kann dabei \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-05T05:00:04.554Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-263083 | Tenda i21 setUplinkInfo formSetUplinkInfo stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.263083" }, { "name": "VDB-263083 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.263083" }, { "name": "Submit #323604 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.323604" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formSetUplinkInfo.md" } ], "timeline": [ { "lang": "en", "time": "2024-05-04T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-05-04T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-05-04T09:28:13.000Z", "value": "VulDB entry last update" } ], "title": "Tenda i21 setUplinkInfo formSetUplinkInfo stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-4494", "datePublished": "2024-05-05T05:00:04.554Z", "dateReserved": "2024-05-04T07:22:46.769Z", "dateUpdated": "2024-08-01T20:40:47.334Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-44362
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:47:05.836Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/Double-q1015/CVE-vulns/blob/main/Tenda/i21/formAddSysLogRule/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda i21 V1.0.0.14(4656) is vulnerable to Buffer Overflow via /goform/AddSysLogRule." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-02T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/Double-q1015/CVE-vulns/blob/main/Tenda/i21/formAddSysLogRule/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-44362", "datePublished": "2022-12-02T00:00:00", "dateReserved": "2022-10-30T00:00:00", "dateUpdated": "2024-08-03T13:47:05.836Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-4246
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.262137 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.262137 | signature, permissions-required | |
https://vuldb.com/?submit.319831 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formQosManageDouble_user.md | related |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:i21:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "i21", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.14 (4656)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-4246", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-04-29T15:29:21.679750Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:55:12.025Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:33:53.283Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-262137 | Tenda i21 formQosManageDouble_auto stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.262137" }, { "name": "VDB-262137 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.262137" }, { "name": "Submit #319831 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.319831" }, { "tags": [ "related", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formQosManageDouble_user.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "i21", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). This affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The identifier VDB-262137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine kritische Schwachstelle in Tenda i21 1.0.0.14(4656) gefunden. Es geht dabei um die Funktion formQosManageDouble_auto. Durch das Manipulieren des Arguments ssidIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-27T08:31:05.312Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-262137 | Tenda i21 formQosManageDouble_auto stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.262137" }, { "name": "VDB-262137 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.262137" }, { "name": "Submit #319831 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.319831" }, { "tags": [ "related" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formQosManageDouble_user.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-26T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-26T14:46:16.000Z", "value": "VulDB entry last update" } ], "title": "Tenda i21 formQosManageDouble_auto stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-4246", "datePublished": "2024-04-27T08:31:05.312Z", "dateReserved": "2024-04-26T12:40:27.568Z", "dateUpdated": "2024-08-01T20:33:53.283Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-4251
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.262142 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.262142 | signature, permissions-required | |
https://vuldb.com/?submit.319836 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/fromDhcpSetSer.md | exploit |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:i21_firmware:1.0.0.14\\(4656\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "i21_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.14\\(4656\\)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-4251", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-05-28T18:43:43.233736Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:55:19.363Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:33:53.048Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-262142 | Tenda i21 DhcpSetSe fromDhcpSetSer stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.262142" }, { "name": "VDB-262142 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.262142" }, { "name": "Submit #319836 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.319836" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/fromDhcpSetSer.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "i21", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_tu (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been rated as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSe. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda i21 1.0.0.14(4656) ausgemacht. Dies betrifft die Funktion fromDhcpSetSer der Datei /goform/DhcpSetSe. Dank Manipulation des Arguments dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-27T13:00:08.629Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-262142 | Tenda i21 DhcpSetSe fromDhcpSetSer stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.262142" }, { "name": "VDB-262142 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.262142" }, { "name": "Submit #319836 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.319836" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/fromDhcpSetSer.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-26T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-26T14:46:25.000Z", "value": "VulDB entry last update" } ], "title": "Tenda i21 DhcpSetSe fromDhcpSetSer stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-4251", "datePublished": "2024-04-27T13:00:08.629Z", "dateReserved": "2024-04-26T12:40:43.266Z", "dateUpdated": "2024-08-01T20:33:53.048Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-4248
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.262139 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.262139 | signature, permissions-required | |
https://vuldb.com/?submit.319833 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formQosManage_user.md | related |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:i21_firmware:1.0.0.14\\(4656\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "i21_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.14\\(4656\\)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-4248", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-04-29T17:29:37.741094Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:54:00.630Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:33:53.173Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-262139 | Tenda i21 formQosManage_user stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.262139" }, { "name": "VDB-262139 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.262139" }, { "name": "Submit #319833 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.319833" }, { "tags": [ "related", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formQosManage_user.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "i21", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. This issue affects the function formQosManage_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-262139. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda i21 1.0.0.14(4656) gefunden. Hierbei geht es um die Funktion formQosManage_user. Durch das Beeinflussen des Arguments ssidIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Umgesetzt werden kann der Angriff \u00fcber das Netzwerk." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-27T10:31:04.307Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-262139 | Tenda i21 formQosManage_user stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.262139" }, { "name": "VDB-262139 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.262139" }, { "name": "Submit #319833 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.319833" }, { "tags": [ "related" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formQosManage_user.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-26T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-26T14:46:20.000Z", "value": "VulDB entry last update" } ], "title": "Tenda i21 formQosManage_user stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-4248", "datePublished": "2024-04-27T10:31:04.307Z", "dateReserved": "2024-04-26T12:40:33.211Z", "dateUpdated": "2024-08-01T20:33:53.173Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-4493
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.263082 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.263082 | signature, permissions-required | |
https://vuldb.com/?submit.323602 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formSetAutoPing.md | exploit |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:tenda:i21_firmware:1.0.0.14\\(4656\\):*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "i21_firmware", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.14 (4656)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-4493", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-05-06T17:32:08.910620Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:55:56.102Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:40:47.436Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-263082 | Tenda i21 formSetAutoPing stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.263082" }, { "name": "VDB-263082 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.263082" }, { "name": "Submit #323602 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.323602" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formSetAutoPing.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "i21", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). Affected is the function formSetAutoPing. The manipulation of the argument ping1/ping2 leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-263082 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine Schwachstelle in Tenda i21 1.0.0.14(4656) gefunden. Sie wurde als kritisch eingestuft. Es geht dabei um die Funktion formSetAutoPing. Mittels Manipulieren des Arguments ping1/ping2 mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-05T03:00:04.998Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-263082 | Tenda i21 formSetAutoPing stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.263082" }, { "name": "VDB-263082 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.263082" }, { "name": "Submit #323602 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.323602" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formSetAutoPing.md" } ], "timeline": [ { "lang": "en", "time": "2024-05-04T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-05-04T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-05-04T09:28:11.000Z", "value": "VulDB entry last update" } ], "title": "Tenda i21 formSetAutoPing stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-4493", "datePublished": "2024-05-05T03:00:04.998Z", "dateReserved": "2024-05-04T07:22:44.057Z", "dateUpdated": "2024-08-01T20:40:47.436Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-44365
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:54:02.577Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/Double-q1015/CVE-vulns/blob/main/Tenda/i21/formSetSysPwd/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda i21 V1.0.0.14(4656) has a stack overflow vulnerability via /goform/setSysPwd." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-02T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/Double-q1015/CVE-vulns/blob/main/Tenda/i21/formSetSysPwd/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-44365", "datePublished": "2022-12-02T00:00:00", "dateReserved": "2022-10-30T00:00:00", "dateUpdated": "2024-08-03T13:54:02.577Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-4249
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.262140 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.262140 | signature, permissions-required | |
https://vuldb.com/?submit.319834 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formwrlSSIDget.md | exploit |
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:h:tenda:i21:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "i21", "vendor": "tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2024-4249", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-04-29T14:26:28.428706Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:54:42.869Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:33:53.189Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-262140 | Tenda i21 wifiSSIDget formwrlSSIDget stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.262140" }, { "name": "VDB-262140 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.262140" }, { "name": "Submit #319834 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.319834" }, { "tags": [ "exploit", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formwrlSSIDget.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "i21", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. Affected is the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262140. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Es wurde eine kritische Schwachstelle in Tenda i21 1.0.0.14(4656) ausgemacht. Es betrifft die Funktion formwrlSSIDget der Datei /goform/wifiSSIDget. Durch Beeinflussen des Arguments ssidIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-27T11:31:05.162Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-262140 | Tenda i21 wifiSSIDget formwrlSSIDget stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.262140" }, { "name": "VDB-262140 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.262140" }, { "name": "Submit #319834 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.319834" }, { "tags": [ "exploit" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formwrlSSIDget.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-26T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-26T14:46:22.000Z", "value": "VulDB entry last update" } ], "title": "Tenda i21 wifiSSIDget formwrlSSIDget stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-4249", "datePublished": "2024-04-27T11:31:05.162Z", "dateReserved": "2024-04-26T12:40:36.518Z", "dateUpdated": "2024-08-01T20:33:53.189Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-44363
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:47:05.907Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/Double-q1015/CVE-vulns/blob/main/Tenda/i21/formSetSnmpInfo/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda i21 V1.0.0.14(4656) is vulnerable to Buffer Overflow via /goform/setSnmpInfo." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-02T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/Double-q1015/CVE-vulns/blob/main/Tenda/i21/formSetSnmpInfo/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-44363", "datePublished": "2022-12-02T00:00:00", "dateReserved": "2022-10-30T00:00:00", "dateUpdated": "2024-08-03T13:47:05.907Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2022-44366
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T13:54:02.577Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://github.com/Double-q1015/CVE-vulns/blob/main/Tenda/i21/formSetDiagnoseInfo/readme.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "Tenda i21 V1.0.0.14(4656) is vulnerable to Buffer Overflow via /goform/setDiagnoseInfo." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-12-02T00:00:00", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://github.com/Double-q1015/CVE-vulns/blob/main/Tenda/i21/formSetDiagnoseInfo/readme.md" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2022-44366", "datePublished": "2022-12-02T00:00:00", "dateReserved": "2022-10-30T00:00:00", "dateUpdated": "2024-08-03T13:54:02.577Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
cve-2024-4245
Vulnerability from cvelistv5
8.8 (High) - CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
▼ | URL | Tags |
---|---|---|
https://vuldb.com/?id.262136 | vdb-entry, technical-description | |
https://vuldb.com/?ctiid.262136 | signature, permissions-required | |
https://vuldb.com/?submit.319830 | third-party-advisory | |
https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formQosManageDouble_auto.md | related |
{ "containers": { "adp": [ { "metrics": [ { "other": { "content": { "id": "CVE-2024-4245", "options": [ { "Exploitation": "poc" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-04-29T17:47:22.323242Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-06-04T17:54:29.133Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-01T20:33:53.069Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "VDB-262136 | Tenda i21 formQosManageDouble_user stack-based overflow", "tags": [ "vdb-entry", "technical-description", "x_transferred" ], "url": "https://vuldb.com/?id.262136" }, { "name": "VDB-262136 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required", "x_transferred" ], "url": "https://vuldb.com/?ctiid.262136" }, { "name": "Submit #319830 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory", "x_transferred" ], "url": "https://vuldb.com/?submit.319830" }, { "tags": [ "related", "x_transferred" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formQosManageDouble_auto.md" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "i21", "vendor": "Tenda", "versions": [ { "status": "affected", "version": "1.0.0.14(4656)" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "value": "yhryhryhr_miemie (VulDB User)" } ], "descriptions": [ { "lang": "en", "value": "A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). Affected by this issue is the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The identifier of this vulnerability is VDB-262136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way." }, { "lang": "de", "value": "Eine kritische Schwachstelle wurde in Tenda i21 1.0.0.14(4656) entdeckt. Es geht hierbei um die Funktion formQosManageDouble_user. Mittels Manipulieren des Arguments ssidIndex mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk angegangen werden." } ], "metrics": [ { "cvssV3_1": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, { "cvssV3_0": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, { "cvssV2_0": { "baseScore": 9, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-121", "description": "CWE-121 Stack-based Buffer Overflow", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-04-27T07:31:04.745Z", "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "shortName": "VulDB" }, "references": [ { "name": "VDB-262136 | Tenda i21 formQosManageDouble_user stack-based overflow", "tags": [ "vdb-entry", "technical-description" ], "url": "https://vuldb.com/?id.262136" }, { "name": "VDB-262136 | CTI Indicators (IOB, IOC, IOA)", "tags": [ "signature", "permissions-required" ], "url": "https://vuldb.com/?ctiid.262136" }, { "name": "Submit #319830 | Tenda i21 V1.0.0.14(4656) Buffer Overflow", "tags": [ "third-party-advisory" ], "url": "https://vuldb.com/?submit.319830" }, { "tags": [ "related" ], "url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/i/i21/formQosManageDouble_auto.md" } ], "timeline": [ { "lang": "en", "time": "2024-04-26T00:00:00.000Z", "value": "Advisory disclosed" }, { "lang": "en", "time": "2024-04-26T02:00:00.000Z", "value": "VulDB entry created" }, { "lang": "en", "time": "2024-04-26T14:46:14.000Z", "value": "VulDB entry last update" } ], "title": "Tenda i21 formQosManageDouble_user stack-based overflow" } }, "cveMetadata": { "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5", "assignerShortName": "VulDB", "cveId": "CVE-2024-4245", "datePublished": "2024-04-27T07:31:04.745Z", "dateReserved": "2024-04-26T12:40:24.988Z", "dateUpdated": "2024-08-01T20:33:53.069Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1" }
var-202405-0051
Vulnerability from variot
A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263080. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point of China's Tenda Company. The vulnerability is caused by the parameter cmdinput of the function formGetDiagnoseInfo failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202405-0051", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "i21", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "1.0.0.14(4656)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22404" } ] }, "cve": "CVE-2024-4491", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-22404", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-4491", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-22404", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22404" }, { "db": "NVD", "id": "CVE-2024-4491" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263080. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point of China\u0027s Tenda Company. The vulnerability is caused by the parameter cmdinput of the function formGetDiagnoseInfo failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack", "sources": [ { "db": "NVD", "id": "CVE-2024-4491" }, { "db": "CNVD", "id": "CNVD-2024-22404" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-4491", "trust": 1.6 }, { "db": "VULDB", "id": "263080", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-22404", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22404" }, { "db": "NVD", "id": "CVE-2024-4491" } ] }, "id": "VAR-202405-0051", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-22404" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22404" } ] }, "last_update_date": "2024-06-05T23:30:23.676000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-4491" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/i/i21/formgetdiagnoseinfo.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.263080" }, { "trust": 1.0, "url": "https://vuldb.com/?id.263080" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.323600" }, { "trust": 0.6, "url": "https://www.cnnvd.org.cn/home/globalsearch?keyword=cve-2024-4491" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22404" }, { "db": "NVD", "id": "CVE-2024-4491" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-22404" }, { "db": "NVD", "id": "CVE-2024-4491" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-11T00:00:00", "db": "CNVD", "id": "CNVD-2024-22404" }, { "date": "2024-05-05T00:15:07.373000", "db": "NVD", "id": "CVE-2024-4491" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-14T00:00:00", "db": "CNVD", "id": "CNVD-2024-22404" }, { "date": "2024-06-04T19:20:38.950000", "db": "NVD", "id": "CVE-2024-4491" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda i21 formGetDiagnoseInfo function buffer overflow vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-22404" } ], "trust": 0.6 } }
var-202404-2111
Vulnerability from variot
A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. This issue affects the function formQosManage_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-262139. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point from China's Tenda company. No detailed vulnerability details are provided at present
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202404-2111", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "i21", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "1.0.0.14(4656)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23297" } ] }, "cve": "CVE-2024-4248", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-23297", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-4248", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-23297", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23297" }, { "db": "NVD", "id": "CVE-2024-4248" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. This issue affects the function formQosManage_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-262139. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point from China\u0027s Tenda company. No detailed vulnerability details are provided at present", "sources": [ { "db": "NVD", "id": "CVE-2024-4248" }, { "db": "CNVD", "id": "CNVD-2024-23297" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-4248", "trust": 1.6 }, { "db": "VULDB", "id": "262139", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-23297", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23297" }, { "db": "NVD", "id": "CVE-2024-4248" } ] }, "id": "VAR-202404-2111", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-23297" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23297" } ] }, "last_update_date": "2024-06-05T23:15:13.055000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-4248" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/i/i21/formqosmanage_user.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.262139" }, { "trust": 1.0, "url": "https://vuldb.com/?id.262139" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.319833" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-4248" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23297" }, { "db": "NVD", "id": "CVE-2024-4248" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-23297" }, { "db": "NVD", "id": "CVE-2024-4248" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-22T00:00:00", "db": "CNVD", "id": "CNVD-2024-23297" }, { "date": "2024-04-27T11:15:06.500000", "db": "NVD", "id": "CVE-2024-4248" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-20T00:00:00", "db": "CNVD", "id": "CNVD-2024-23297" }, { "date": "2024-06-04T19:20:34", "db": "NVD", "id": "CVE-2024-4248" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda i21 has an unspecified vulnerability (CNVD-2024-23297)", "sources": [ { "db": "CNVD", "id": "CNVD-2024-23297" } ], "trust": 0.6 } }
var-202405-0137
Vulnerability from variot
A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). This issue affects the function formOfflineSet of the file /goform/setStaOffline. The manipulation of the argument GO/ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263081 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point of China's Tenda Company. The vulnerability is caused by the parameter GO/ssidIndex of the file/goform/setStaOffline failing to correctly verify the length of the input data. A remote attacker can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202405-0137", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "i21", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "1.0.0.14(4656)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22406" } ] }, "cve": "CVE-2024-4492", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-22406", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-4492", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-22406", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22406" }, { "db": "NVD", "id": "CVE-2024-4492" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). This issue affects the function formOfflineSet of the file /goform/setStaOffline. The manipulation of the argument GO/ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263081 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point of China\u0027s Tenda Company. The vulnerability is caused by the parameter GO/ssidIndex of the file/goform/setStaOffline failing to correctly verify the length of the input data. A remote attacker can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack", "sources": [ { "db": "NVD", "id": "CVE-2024-4492" }, { "db": "CNVD", "id": "CNVD-2024-22406" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-4492", "trust": 1.6 }, { "db": "VULDB", "id": "263081", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-22406", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22406" }, { "db": "NVD", "id": "CVE-2024-4492" } ] }, "id": "VAR-202405-0137", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-22406" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22406" } ] }, "last_update_date": "2024-06-05T23:17:51.162000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-4492" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/i/i21/formofflineset.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.263081" }, { "trust": 1.0, "url": "https://vuldb.com/?id.263081" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.323601" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-4492" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22406" }, { "db": "NVD", "id": "CVE-2024-4492" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-22406" }, { "db": "NVD", "id": "CVE-2024-4492" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-11T00:00:00", "db": "CNVD", "id": "CNVD-2024-22406" }, { "date": "2024-05-05T01:15:06.380000", "db": "NVD", "id": "CVE-2024-4492" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-14T00:00:00", "db": "CNVD", "id": "CNVD-2024-22406" }, { "date": "2024-06-04T19:20:39.047000", "db": "NVD", "id": "CVE-2024-4492" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda i21 formsetStaOffline function buffer overflow vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-22406" } ], "trust": 0.6 } }
var-202405-0092
Vulnerability from variot
A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263083. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point of China's Tenda company. The vulnerability is caused by the parameter pingHostIp2 of the file /goform/setUplinkInfo failing to correctly verify the length of the input data. A remote attacker can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202405-0092", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "i21", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "1.0.0.14(4656)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22407" } ] }, "cve": "CVE-2024-4494", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-22407", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-4494", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-22407", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22407" }, { "db": "NVD", "id": "CVE-2024-4494" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263083. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point of China\u0027s Tenda company. The vulnerability is caused by the parameter pingHostIp2 of the file /goform/setUplinkInfo failing to correctly verify the length of the input data. A remote attacker can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack", "sources": [ { "db": "NVD", "id": "CVE-2024-4494" }, { "db": "CNVD", "id": "CNVD-2024-22407" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-4494", "trust": 1.6 }, { "db": "VULDB", "id": "263083", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-22407", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22407" }, { "db": "NVD", "id": "CVE-2024-4494" } ] }, "id": "VAR-202405-0092", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-22407" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22407" } ] }, "last_update_date": "2024-06-05T23:27:13.340000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-4494" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/i/i21/formsetuplinkinfo.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.263083" }, { "trust": 1.0, "url": "https://vuldb.com/?id.263083" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.323604" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-4494" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22407" }, { "db": "NVD", "id": "CVE-2024-4494" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-22407" }, { "db": "NVD", "id": "CVE-2024-4494" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-11T00:00:00", "db": "CNVD", "id": "CNVD-2024-22407" }, { "date": "2024-05-05T05:15:06.530000", "db": "NVD", "id": "CVE-2024-4494" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-14T00:00:00", "db": "CNVD", "id": "CNVD-2024-22407" }, { "date": "2024-06-04T19:20:39.240000", "db": "NVD", "id": "CVE-2024-4494" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda i21 formsetUplinkInfo function buffer overflow vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-22407" } ], "trust": 0.6 } }
var-202404-2089
Vulnerability from variot
A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. This vulnerability affects the function formQosManage_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. VDB-262138 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point from China's Tenda company. No detailed vulnerability details are provided at present
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202404-2089", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "i21", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "1.0.0.14(4656)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23296" } ] }, "cve": "CVE-2024-4247", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-23296", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-4247", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-23296", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23296" }, { "db": "NVD", "id": "CVE-2024-4247" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. This vulnerability affects the function formQosManage_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. VDB-262138 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point from China\u0027s Tenda company. No detailed vulnerability details are provided at present", "sources": [ { "db": "NVD", "id": "CVE-2024-4247" }, { "db": "CNVD", "id": "CNVD-2024-23296" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-4247", "trust": 1.6 }, { "db": "VULDB", "id": "262138", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-23296", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23296" }, { "db": "NVD", "id": "CVE-2024-4247" } ] }, "id": "VAR-202404-2089", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-23296" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23296" } ] }, "last_update_date": "2024-06-05T23:36:15.925000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-4247" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/i/i21/formqosmanage_auto.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.262138" }, { "trust": 1.0, "url": "https://vuldb.com/?id.262138" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.319832" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-4247" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23296" }, { "db": "NVD", "id": "CVE-2024-4247" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-23296" }, { "db": "NVD", "id": "CVE-2024-4247" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-17T00:00:00", "db": "CNVD", "id": "CNVD-2024-23296" }, { "date": "2024-04-27T10:15:08.730000", "db": "NVD", "id": "CVE-2024-4247" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-20T00:00:00", "db": "CNVD", "id": "CNVD-2024-23296" }, { "date": "2024-06-04T19:20:33.897000", "db": "NVD", "id": "CVE-2024-4247" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda i21 has an unspecified vulnerability (CNVD-2024-23296)", "sources": [ { "db": "CNVD", "id": "CNVD-2024-23296" } ], "trust": 0.6 } }
var-202404-2112
Vulnerability from variot
A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). Affected by this issue is the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The identifier of this vulnerability is VDB-262136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point from China's Tenda company. No detailed vulnerability details are provided at present
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202404-2112", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "i21", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "1.0.0.14(4656)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23294" } ] }, "cve": "CVE-2024-4245", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-23294", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-4245", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-23294", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23294" }, { "db": "NVD", "id": "CVE-2024-4245" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). Affected by this issue is the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The identifier of this vulnerability is VDB-262136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point from China\u0027s Tenda company. No detailed vulnerability details are provided at present", "sources": [ { "db": "NVD", "id": "CVE-2024-4245" }, { "db": "CNVD", "id": "CNVD-2024-23294" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-4245", "trust": 1.6 }, { "db": "VULDB", "id": "262136", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-23294", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23294" }, { "db": "NVD", "id": "CVE-2024-4245" } ] }, "id": "VAR-202404-2112", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-23294" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23294" } ] }, "last_update_date": "2024-06-05T23:36:15.895000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-4245" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/i/i21/formqosmanagedouble_auto.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.262136" }, { "trust": 1.0, "url": "https://vuldb.com/?id.262136" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.319830" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-4245" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23294" }, { "db": "NVD", "id": "CVE-2024-4245" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-23294" }, { "db": "NVD", "id": "CVE-2024-4245" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-17T00:00:00", "db": "CNVD", "id": "CNVD-2024-23294" }, { "date": "2024-04-27T08:15:06.277000", "db": "NVD", "id": "CVE-2024-4245" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-20T00:00:00", "db": "CNVD", "id": "CNVD-2024-23294" }, { "date": "2024-06-04T19:20:33.693000", "db": "NVD", "id": "CVE-2024-4245" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda i21 has an unspecified vulnerability (CNVD-2024-23294)", "sources": [ { "db": "CNVD", "id": "CNVD-2024-23294" } ], "trust": 0.6 } }
var-202405-0066
Vulnerability from variot
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263085 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point from China's Tenda company. The vulnerability is caused by the parameter ssidIndex of the function formWifiMacFilterSet failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202405-0066", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "i21", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "1.0.0.14(4656)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22409" } ] }, "cve": "CVE-2024-4496", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-22409", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-4496", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-22409", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22409" }, { "db": "NVD", "id": "CVE-2024-4496" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263085 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point from China\u0027s Tenda company. The vulnerability is caused by the parameter ssidIndex of the function formWifiMacFilterSet failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack", "sources": [ { "db": "NVD", "id": "CVE-2024-4496" }, { "db": "CNVD", "id": "CNVD-2024-22409" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-4496", "trust": 1.6 }, { "db": "VULDB", "id": "263085", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-22409", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22409" }, { "db": "NVD", "id": "CVE-2024-4496" } ] }, "id": "VAR-202405-0066", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-22409" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22409" } ] }, "last_update_date": "2024-06-05T23:26:43.288000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-4496" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/i/i21/formwifimacfilterset.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.263085" }, { "trust": 1.0, "url": "https://vuldb.com/?id.263085" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.323606" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-4496" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22409" }, { "db": "NVD", "id": "CVE-2024-4496" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-22409" }, { "db": "NVD", "id": "CVE-2024-4496" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-11T00:00:00", "db": "CNVD", "id": "CNVD-2024-22409" }, { "date": "2024-05-05T06:15:08.027000", "db": "NVD", "id": "CVE-2024-4496" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-14T00:00:00", "db": "CNVD", "id": "CNVD-2024-22409" }, { "date": "2024-06-04T19:20:39.340000", "db": "NVD", "id": "CVE-2024-4496" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda i21 formWifiMacFilterSet function buffer overflow vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-22409" } ], "trust": 0.6 } }
var-202404-2100
Vulnerability from variot
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. Affected is the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262140. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point from China's Tenda company. No detailed vulnerability details are provided at present
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202404-2100", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "i21", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "1.0.0.14(4656)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23298" } ] }, "cve": "CVE-2024-4249", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-23298", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-4249", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-23298", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23298" }, { "db": "NVD", "id": "CVE-2024-4249" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. Affected is the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262140. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point from China\u0027s Tenda company. No detailed vulnerability details are provided at present", "sources": [ { "db": "NVD", "id": "CVE-2024-4249" }, { "db": "CNVD", "id": "CNVD-2024-23298" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-4249", "trust": 1.6 }, { "db": "VULDB", "id": "262140", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-23298", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23298" }, { "db": "NVD", "id": "CVE-2024-4249" } ] }, "id": "VAR-202404-2100", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-23298" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23298" } ] }, "last_update_date": "2024-06-06T23:10:25.514000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-4249" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/i/i21/formwrlssidget.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.262140" }, { "trust": 1.0, "url": "https://vuldb.com/?id.262140" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.319834" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-4249" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23298" }, { "db": "NVD", "id": "CVE-2024-4249" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-23298" }, { "db": "NVD", "id": "CVE-2024-4249" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-17T00:00:00", "db": "CNVD", "id": "CNVD-2024-23298" }, { "date": "2024-04-27T12:15:10.740000", "db": "NVD", "id": "CVE-2024-4249" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-20T00:00:00", "db": "CNVD", "id": "CNVD-2024-23298" }, { "date": "2024-06-04T19:20:34.093000", "db": "NVD", "id": "CVE-2024-4249" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda i21 has an unspecified vulnerability (CNVD-2024-23298)", "sources": [ { "db": "CNVD", "id": "CNVD-2024-23298" } ], "trust": 0.6 } }
var-202404-2097
Vulnerability from variot
A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). This affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The identifier VDB-262137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point from China's Tenda company. No detailed vulnerability details are provided at present
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202404-2097", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "i21", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "1.0.0.14(4656)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23295" } ] }, "cve": "CVE-2024-4246", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-23295", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-4246", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-23295", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23295" }, { "db": "NVD", "id": "CVE-2024-4246" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). This affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The identifier VDB-262137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point from China\u0027s Tenda company. No detailed vulnerability details are provided at present", "sources": [ { "db": "NVD", "id": "CVE-2024-4246" }, { "db": "CNVD", "id": "CNVD-2024-23295" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-4246", "trust": 1.6 }, { "db": "VULDB", "id": "262137", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-23295", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23295" }, { "db": "NVD", "id": "CVE-2024-4246" } ] }, "id": "VAR-202404-2097", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-23295" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23295" } ] }, "last_update_date": "2024-06-05T23:35:43.126000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-4246" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/i/i21/formqosmanagedouble_user.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.262137" }, { "trust": 1.0, "url": "https://vuldb.com/?id.262137" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.319831" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-4246" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23295" }, { "db": "NVD", "id": "CVE-2024-4246" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-23295" }, { "db": "NVD", "id": "CVE-2024-4246" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-17T00:00:00", "db": "CNVD", "id": "CNVD-2024-23295" }, { "date": "2024-04-27T09:15:09.307000", "db": "NVD", "id": "CVE-2024-4246" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-20T00:00:00", "db": "CNVD", "id": "CNVD-2024-23295" }, { "date": "2024-06-04T19:20:33.790000", "db": "NVD", "id": "CVE-2024-4246" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda i21 has an unspecified vulnerability (CNVD-2024-23295)", "sources": [ { "db": "CNVD", "id": "CNVD-2024-23295" } ], "trust": 0.6 } }
var-202405-0120
Vulnerability from variot
A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263084. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point of China's Tenda company. The vulnerability is caused by the parameter index of the function formWifiMacFilterGet failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202405-0120", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "i21", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "1.0.0.14(4656)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22408" } ] }, "cve": "CVE-2024-4495", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-22408", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-4495", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-22408", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22408" }, { "db": "NVD", "id": "CVE-2024-4495" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263084. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point of China\u0027s Tenda company. The vulnerability is caused by the parameter index of the function formWifiMacFilterGet failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack", "sources": [ { "db": "NVD", "id": "CVE-2024-4495" }, { "db": "CNVD", "id": "CNVD-2024-22408" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-4495", "trust": 1.6 }, { "db": "VULDB", "id": "263084", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-22408", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22408" }, { "db": "NVD", "id": "CVE-2024-4495" } ] }, "id": "VAR-202405-0120", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-22408" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22408" } ] }, "last_update_date": "2024-05-17T23:09:14.510000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-4495" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/i/i21/formwifimacfilterget.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.263084" }, { "trust": 1.0, "url": "https://vuldb.com/?id.263084" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.323605" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-4495" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22408" }, { "db": "NVD", "id": "CVE-2024-4495" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-22408" }, { "db": "NVD", "id": "CVE-2024-4495" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-11T00:00:00", "db": "CNVD", "id": "CNVD-2024-22408" }, { "date": "2024-05-05T06:15:06.637000", "db": "NVD", "id": "CVE-2024-4495" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-14T00:00:00", "db": "CNVD", "id": "CNVD-2024-22408" }, { "date": "2024-05-17T02:40:25.167000", "db": "NVD", "id": "CVE-2024-4495" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda i21 formWifiMacFilterGet function buffer overflow vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-22408" } ], "trust": 0.6 } }
var-202404-2094
Vulnerability from variot
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. Affected by this vulnerability is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point of China's Tenda company. No detailed vulnerability details are provided at present
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202404-2094", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "i21", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "1.0.0.14(4656)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23299" } ] }, "cve": "CVE-2024-4250", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-23299", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-4250", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-23299", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23299" }, { "db": "NVD", "id": "CVE-2024-4250" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. Affected by this vulnerability is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262141 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point of China\u0027s Tenda company. No detailed vulnerability details are provided at present", "sources": [ { "db": "NVD", "id": "CVE-2024-4250" }, { "db": "CNVD", "id": "CNVD-2024-23299" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-4250", "trust": 1.6 }, { "db": "VULDB", "id": "262141", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-23299", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23299" }, { "db": "NVD", "id": "CVE-2024-4250" } ] }, "id": "VAR-202404-2094", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-23299" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23299" } ] }, "last_update_date": "2024-06-06T23:01:55.408000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-4250" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/i/i21/formwrlssidset.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.262141" }, { "trust": 1.0, "url": "https://vuldb.com/?id.262141" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.319835" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-4250" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23299" }, { "db": "NVD", "id": "CVE-2024-4250" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-23299" }, { "db": "NVD", "id": "CVE-2024-4250" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-17T00:00:00", "db": "CNVD", "id": "CNVD-2024-23299" }, { "date": "2024-04-27T12:15:10.963000", "db": "NVD", "id": "CVE-2024-4250" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-20T00:00:00", "db": "CNVD", "id": "CNVD-2024-23299" }, { "date": "2024-06-04T19:20:34.200000", "db": "NVD", "id": "CVE-2024-4250" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda i21 has an unspecified vulnerability (CNVD-2024-23299)", "sources": [ { "db": "CNVD", "id": "CNVD-2024-23299" } ], "trust": 0.6 } }
var-202404-2104
Vulnerability from variot
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been rated as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSe. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point from China's Tenda company. No detailed vulnerability details are currently provided
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202404-2104", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "i21", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "1.0.0.14(4656)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23300" } ] }, "cve": "CVE-2024-4251", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-23300", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-4251", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-23300", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23300" }, { "db": "NVD", "id": "CVE-2024-4251" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been rated as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSe. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point from China\u0027s Tenda company. No detailed vulnerability details are currently provided", "sources": [ { "db": "NVD", "id": "CVE-2024-4251" }, { "db": "CNVD", "id": "CNVD-2024-23300" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-4251", "trust": 1.6 }, { "db": "VULDB", "id": "262142", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-23300", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23300" }, { "db": "NVD", "id": "CVE-2024-4251" } ] }, "id": "VAR-202404-2104", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-23300" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23300" } ] }, "last_update_date": "2024-06-05T23:34:09.254000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-4251" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/i/i21/fromdhcpsetser.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.262142" }, { "trust": 1.0, "url": "https://vuldb.com/?id.262142" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.319836" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-4251" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-23300" }, { "db": "NVD", "id": "CVE-2024-4251" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-23300" }, { "db": "NVD", "id": "CVE-2024-4251" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-17T00:00:00", "db": "CNVD", "id": "CNVD-2024-23300" }, { "date": "2024-04-27T13:15:09.850000", "db": "NVD", "id": "CVE-2024-4251" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-20T00:00:00", "db": "CNVD", "id": "CNVD-2024-23300" }, { "date": "2024-06-04T19:20:34.297000", "db": "NVD", "id": "CVE-2024-4251" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda i21 has an unspecified vulnerability (CNVD-2024-23300)", "sources": [ { "db": "CNVD", "id": "CNVD-2024-23300" } ], "trust": 0.6 } }
var-202405-0129
Vulnerability from variot
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point of China's Tenda Company. The vulnerability is caused by the parameter cmdinput of the function formexeCommand failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202405-0129", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "i21", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "1.0.0.14(4656)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22403" } ] }, "cve": "CVE-2024-4497", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-22403", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-4497", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-22403", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22403" }, { "db": "NVD", "id": "CVE-2024-4497" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point of China\u0027s Tenda Company. The vulnerability is caused by the parameter cmdinput of the function formexeCommand failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack", "sources": [ { "db": "NVD", "id": "CVE-2024-4497" }, { "db": "CNVD", "id": "CNVD-2024-22403" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-4497", "trust": 1.6 }, { "db": "VULDB", "id": "263086", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-22403", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22403" }, { "db": "NVD", "id": "CVE-2024-4497" } ] }, "id": "VAR-202405-0129", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-22403" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22403" } ] }, "last_update_date": "2024-06-05T23:26:43.263000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-4497" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/i/i21/formexecommand.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.263086" }, { "trust": 1.0, "url": "https://vuldb.com/?id.263086" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.323607" }, { "trust": 0.6, "url": "https://www.cnnvd.org.cn/home/globalsearch?keyword=cve-2024-4497" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22403" }, { "db": "NVD", "id": "CVE-2024-4497" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-22403" }, { "db": "NVD", "id": "CVE-2024-4497" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-11T00:00:00", "db": "CNVD", "id": "CNVD-2024-22403" }, { "date": "2024-05-05T07:15:06.463000", "db": "NVD", "id": "CVE-2024-4497" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-14T00:00:00", "db": "CNVD", "id": "CNVD-2024-22403" }, { "date": "2024-06-04T19:20:39.437000", "db": "NVD", "id": "CVE-2024-4497" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda i21 formexeCommand function buffer overflow vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-22403" } ], "trust": 0.6 } }
var-202405-0133
Vulnerability from variot
A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). Affected is the function formSetAutoPing. The manipulation of the argument ping1/ping2 leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-263082 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point of China's Tenda Company. The vulnerability is caused by the failure of the parameter ping1/ping2 of the function formSetAutoPing to correctly verify the length of the input data. A remote attacker can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202405-0133", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "i21", "scope": "eq", "trust": 0.6, "vendor": "tenda", "version": "1.0.0.14(4656)" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22405" } ] }, "cve": "CVE-2024-4493", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "cna@vuldb.com", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "SINGLE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 9.0, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.0, "id": "CNVD-2024-22405", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "cna@vuldb.com", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ], "severity": [ { "author": "cna@vuldb.com", "id": "CVE-2024-4493", "trust": 1.0, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2024-22405", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22405" }, { "db": "NVD", "id": "CVE-2024-4493" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). Affected is the function formSetAutoPing. The manipulation of the argument ping1/ping2 leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-263082 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point of China\u0027s Tenda Company. The vulnerability is caused by the failure of the parameter ping1/ping2 of the function formSetAutoPing to correctly verify the length of the input data. A remote attacker can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack", "sources": [ { "db": "NVD", "id": "CVE-2024-4493" }, { "db": "CNVD", "id": "CNVD-2024-22405" } ], "trust": 1.44 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2024-4493", "trust": 1.6 }, { "db": "VULDB", "id": "263082", "trust": 1.0 }, { "db": "CNVD", "id": "CNVD-2024-22405", "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22405" }, { "db": "NVD", "id": "CVE-2024-4493" } ] }, "id": "VAR-202405-0133", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2024-22405" } ], "trust": 1.6 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "Network device" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22405" } ] }, "last_update_date": "2024-06-05T23:34:09.186000Z", "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-121", "trust": 1.0 } ], "sources": [ { "db": "NVD", "id": "CVE-2024-4493" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.0, "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/i/i21/formsetautoping.md" }, { "trust": 1.0, "url": "https://vuldb.com/?ctiid.263082" }, { "trust": 1.0, "url": "https://vuldb.com/?id.263082" }, { "trust": 1.0, "url": "https://vuldb.com/?submit.323602" }, { "trust": 0.6, "url": "https://nvd.nist.gov/vuln/detail/cve-2024-4493" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2024-22405" }, { "db": "NVD", "id": "CVE-2024-4493" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2024-22405" }, { "db": "NVD", "id": "CVE-2024-4493" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-11T00:00:00", "db": "CNVD", "id": "CNVD-2024-22405" }, { "date": "2024-05-05T03:15:07.340000", "db": "NVD", "id": "CVE-2024-4493" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2024-05-14T00:00:00", "db": "CNVD", "id": "CNVD-2024-22405" }, { "date": "2024-06-04T19:20:39.143000", "db": "NVD", "id": "CVE-2024-4493" } ] }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Tenda i21 formSetAutoPing function buffer overflow vulnerability", "sources": [ { "db": "CNVD", "id": "CNVD-2024-22405" } ], "trust": 0.6 } }