var-202405-0129
Vulnerability from variot

A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point of China's Tenda Company. The vulnerability is caused by the parameter cmdinput of the function formexeCommand failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202405-0129",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "i21",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "tenda",
        "version": "1.0.0.14(4656)"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-22403"
      }
    ]
  },
  "cve": "CVE-2024-4497",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "cna@vuldb.com",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "HIGH",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2024-22403",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cna@vuldb.com",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "cna@vuldb.com",
            "id": "CVE-2024-4497",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-22403",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-22403"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-4497"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Tenda i21 is a wireless access point of China\u0027s Tenda Company. The vulnerability is caused by the parameter cmdinput of the function formexeCommand failing to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-4497"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-22403"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-4497",
        "trust": 1.6
      },
      {
        "db": "VULDB",
        "id": "263086",
        "trust": 1.0
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-22403",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-22403"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-4497"
      }
    ]
  },
  "id": "VAR-202405-0129",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-22403"
      }
    ],
    "trust": 1.6
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-22403"
      }
    ]
  },
  "last_update_date": "2024-06-05T23:26:43.263000Z",
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-4497"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.0,
        "url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/i/i21/formexecommand.md"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?ctiid.263086"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?id.263086"
      },
      {
        "trust": 1.0,
        "url": "https://vuldb.com/?submit.323607"
      },
      {
        "trust": 0.6,
        "url": "https://www.cnnvd.org.cn/home/globalsearch?keyword=cve-2024-4497"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-22403"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-4497"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-22403"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-4497"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-05-11T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-22403"
      },
      {
        "date": "2024-05-05T07:15:06.463000",
        "db": "NVD",
        "id": "CVE-2024-4497"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-05-14T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-22403"
      },
      {
        "date": "2024-06-04T19:20:39.437000",
        "db": "NVD",
        "id": "CVE-2024-4497"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Tenda i21 formexeCommand function buffer overflow vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-22403"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.