Search criteria
2 vulnerabilities found for iDRAC7/iDRAC8 by Dell EMC
CVE-2018-1211 (GCVE-0-2018-1211)
Vulnerability from cvelistv5 – Published: 2018-03-23 14:00 – Updated: 2024-09-16 20:22
VLAI?
Summary
Dell EMC iDRAC7/iDRAC8, versions prior to 2.52.52.52, contain a path traversal vulnerability in its Web server's URI parser which could be used to obtain specific sensitive data without authentication. A remote unauthenticated attacker may be able to read configuration settings from the iDRAC by querying specific URI strings.
Severity ?
No CVSS data available.
CWE
- path traversal vulnerability
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell EMC | iDRAC7/iDRAC8 |
Affected:
versions prior to 2.52.52.52
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T03:51:48.979Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://en.community.dell.com/techcenter/extras/m/white_papers/20485410"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "iDRAC7/iDRAC8",
"vendor": "Dell EMC",
"versions": [
{
"status": "affected",
"version": "versions prior to 2.52.52.52"
}
]
}
],
"datePublic": "2018-03-20T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC7/iDRAC8, versions prior to 2.52.52.52, contain a path traversal vulnerability in its Web server\u0027s URI parser which could be used to obtain specific sensitive data without authentication. A remote unauthenticated attacker may be able to read configuration settings from the iDRAC by querying specific URI strings."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "path traversal vulnerability",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-23T13:57:01",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://en.community.dell.com/techcenter/extras/m/white_papers/20485410"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security_alert@emc.com",
"DATE_PUBLIC": "2018-03-20T00:00:00",
"ID": "CVE-2018-1211",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "iDRAC7/iDRAC8",
"version": {
"version_data": [
{
"version_value": "versions prior to 2.52.52.52"
}
]
}
}
]
},
"vendor_name": "Dell EMC"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC7/iDRAC8, versions prior to 2.52.52.52, contain a path traversal vulnerability in its Web server\u0027s URI parser which could be used to obtain specific sensitive data without authentication. A remote unauthenticated attacker may be able to read configuration settings from the iDRAC by querying specific URI strings."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "path traversal vulnerability"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://en.community.dell.com/techcenter/extras/m/white_papers/20485410",
"refsource": "MISC",
"url": "http://en.community.dell.com/techcenter/extras/m/white_papers/20485410"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2018-1211",
"datePublished": "2018-03-23T14:00:00Z",
"dateReserved": "2017-12-06T00:00:00",
"dateUpdated": "2024-09-16T20:22:05.961Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-1211 (GCVE-0-2018-1211)
Vulnerability from nvd – Published: 2018-03-23 14:00 – Updated: 2024-09-16 20:22
VLAI?
Summary
Dell EMC iDRAC7/iDRAC8, versions prior to 2.52.52.52, contain a path traversal vulnerability in its Web server's URI parser which could be used to obtain specific sensitive data without authentication. A remote unauthenticated attacker may be able to read configuration settings from the iDRAC by querying specific URI strings.
Severity ?
No CVSS data available.
CWE
- path traversal vulnerability
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell EMC | iDRAC7/iDRAC8 |
Affected:
versions prior to 2.52.52.52
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T03:51:48.979Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://en.community.dell.com/techcenter/extras/m/white_papers/20485410"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "iDRAC7/iDRAC8",
"vendor": "Dell EMC",
"versions": [
{
"status": "affected",
"version": "versions prior to 2.52.52.52"
}
]
}
],
"datePublic": "2018-03-20T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC7/iDRAC8, versions prior to 2.52.52.52, contain a path traversal vulnerability in its Web server\u0027s URI parser which could be used to obtain specific sensitive data without authentication. A remote unauthenticated attacker may be able to read configuration settings from the iDRAC by querying specific URI strings."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "path traversal vulnerability",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-23T13:57:01",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://en.community.dell.com/techcenter/extras/m/white_papers/20485410"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security_alert@emc.com",
"DATE_PUBLIC": "2018-03-20T00:00:00",
"ID": "CVE-2018-1211",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "iDRAC7/iDRAC8",
"version": {
"version_data": [
{
"version_value": "versions prior to 2.52.52.52"
}
]
}
}
]
},
"vendor_name": "Dell EMC"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC7/iDRAC8, versions prior to 2.52.52.52, contain a path traversal vulnerability in its Web server\u0027s URI parser which could be used to obtain specific sensitive data without authentication. A remote unauthenticated attacker may be able to read configuration settings from the iDRAC by querying specific URI strings."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "path traversal vulnerability"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://en.community.dell.com/techcenter/extras/m/white_papers/20485410",
"refsource": "MISC",
"url": "http://en.community.dell.com/techcenter/extras/m/white_papers/20485410"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2018-1211",
"datePublished": "2018-03-23T14:00:00Z",
"dateReserved": "2017-12-06T00:00:00",
"dateUpdated": "2024-09-16T20:22:05.961Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}