Search criteria
57 vulnerabilities found for idrac9_firmware by dell
FKIE_CVE-2022-34435
Vulnerability from fkie_nvd - Published: 2023-01-18 12:15 - Updated: 2024-11-21 07:09
Severity ?
2.7 (Low) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N
4.9 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N
4.9 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N
Summary
Dell iDRAC9 version 6.00.02.00 and prior contain an improper input validation vulnerability in Racadm when the firmware lock-down configuration is set. A remote high privileged attacker could exploit this vulnerability to bypass the firmware lock-down configuration and perform a firmware update.
References
| URL | Tags | ||
|---|---|---|---|
| security_alert@emc.com | https://www.dell.com/support/kbdoc/000205346 | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.dell.com/support/kbdoc/000205346 | Patch, Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | idrac9_firmware | * | |
| dell | idrac9 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dell:idrac9_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3617B6C4-2CAF-4B61-A359-D3DAD45066C2",
"versionEndExcluding": "6.00.30.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dell:idrac9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BD8B684E-092F-496C-9D94-51CCD1F3575A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\nDell iDRAC9 version 6.00.02.00 and prior contain an improper input validation vulnerability in Racadm when the firmware lock-down configuration is set. A remote high privileged attacker could exploit this vulnerability to bypass the firmware lock-down configuration and perform a firmware update.\n\n\n\n\n\n"
},
{
"lang": "es",
"value": "Dell iDRAC9 6.00.02.00 y anteriores contienen una vulnerabilidad de validaci\u00f3n de entrada incorrecta en Racadm cuando se establece la configuraci\u00f3n de bloqueo del firmware. Un atacante remoto con privilegios elevados podr\u00eda aprovechar esta vulnerabilidad para evitar la configuraci\u00f3n de bloqueo del firmware y realizar una actualizaci\u00f3n del firmware."
}
],
"id": "CVE-2022-34435",
"lastModified": "2024-11-21T07:09:33.443",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 2.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 1.4,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-01-18T12:15:10.427",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/000205346"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/000205346"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-21538
Vulnerability from fkie_nvd - Published: 2021-07-29 16:15 - Updated: 2024-11-21 05:48
Severity ?
9.6 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:L
10.0 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
10.0 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Summary
Dell EMC iDRAC9 versions 4.40.00.00 and later, but prior to 4.40.10.00, contain an improper authentication vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability to gain access to the virtual console.
References
| URL | Tags | ||
|---|---|---|---|
| security_alert@emc.com | https://www.dell.com/support/kbdoc/000186420 | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.dell.com/support/kbdoc/000186420 | Patch, Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | idrac9_firmware | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dell:idrac9_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "33E8B56C-2459-4416-9AD7-E450D0A33222",
"versionEndExcluding": "4.40.10.00",
"versionStartIncluding": "4.40.00.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions 4.40.00.00 and later, but prior to 4.40.10.00, contain an improper authentication vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability to gain access to the virtual console."
},
{
"lang": "es",
"value": "Dell EMC iDRAC9 versiones 4.40.00.00 y posteriores, pero anteriores a 4.40.10.00, contienen una vulnerabilidad de autenticaci\u00f3n inapropiada. Un atacante no autenticado remoto podr\u00eda explotar potencialmente esta vulnerabilidad para conseguir acceso a la consola virtual"
}
],
"id": "CVE-2021-21538",
"lastModified": "2024-11-21T05:48:32.987",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 6.0,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 10.0,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 6.0,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-07-29T16:15:08.693",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/000186420"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/000186420"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-21540
Vulnerability from fkie_nvd - Published: 2021-04-30 21:15 - Updated: 2024-11-21 05:48
Severity ?
5.9 (Medium) - CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:L
8.1 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H
8.1 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H
Summary
Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a stack-based overflow vulnerability. A remote authenticated attacker could potentially exploit this vulnerability to overwrite configuration information by injecting arbitrarily large payload.
References
| URL | Tags | ||
|---|---|---|---|
| security_alert@emc.com | https://www.dell.com/support/kbdoc/000185293 | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.dell.com/support/kbdoc/000185293 | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | idrac9_firmware | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dell:idrac9_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5E9ED974-1468-4B8B-B82E-5E0340C2601B",
"versionEndExcluding": "4.40.00.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a stack-based overflow vulnerability. A remote authenticated attacker could potentially exploit this vulnerability to overwrite configuration information by injecting arbitrarily large payload."
},
{
"lang": "es",
"value": "Dell EMC iDRAC9 versiones anteriores a 4.40.00.00, contiene una vulnerabilidad de desbordamiento en la regi\u00f3n stack de la memoria.\u0026#xa0;Un atacante autenticado remoto podr\u00eda explotar potencialmente esta vulnerabilidad para sobrescribir la informaci\u00f3n de configuraci\u00f3n al inyectar una carga \u00fatil arbitrariamente grande."
}
],
"id": "CVE-2021-21540",
"lastModified": "2024-11-21T05:48:33.250",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 4.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 1.6,
"impactScore": 4.2,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-04-30T21:15:08.740",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-21539
Vulnerability from fkie_nvd - Published: 2021-04-30 21:15 - Updated: 2024-11-21 05:48
Severity ?
5.9 (Medium) - CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:L/I:H/A:L
7.1 (High) - CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H
7.1 (High) - CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H
Summary
Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a Time-of-check Time-of-use (TOCTOU) race condition vulnerability. A remote authenticated attacker could potentially exploit this vulnerability to gain elevated privileges when a user with higher privileges is simultaneously accessing iDRAC through the web interface.
References
| URL | Tags | ||
|---|---|---|---|
| security_alert@emc.com | https://www.dell.com/support/kbdoc/000185293 | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.dell.com/support/kbdoc/000185293 | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | idrac9_firmware | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dell:idrac9_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5E9ED974-1468-4B8B-B82E-5E0340C2601B",
"versionEndExcluding": "4.40.00.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a Time-of-check Time-of-use (TOCTOU) race condition vulnerability. A remote authenticated attacker could potentially exploit this vulnerability to gain elevated privileges when a user with higher privileges is simultaneously accessing iDRAC through the web interface."
},
{
"lang": "es",
"value": "Dell EMC iDRAC9 versiones anteriores a 4.40.00.00, contiene una vulnerabilidad de condici\u00f3n de carrera Time-of-check Time-of-use (TOCTOU).\u0026#xa0;Un atacante autenticado remoto podr\u00eda explotar potencialmente esta vulnerabilidad para alcanzar privilegios elevados cuando un usuario con privilegios m\u00e1s elevados accede simult\u00e1neamente a iDRAC a trav\u00e9s de la interfaz web."
}
],
"id": "CVE-2021-21539",
"lastModified": "2024-11-21T05:48:33.110",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "HIGH",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:H/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:L/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 4.7,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-04-30T21:15:08.707",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-367"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-21542
Vulnerability from fkie_nvd - Published: 2021-04-30 21:15 - Updated: 2024-11-21 05:48
Severity ?
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Summary
Dell EMC iDRAC9 versions prior to 4.40.10.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected while generating a certificate. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application.
References
| URL | Tags | ||
|---|---|---|---|
| security_alert@emc.com | https://www.dell.com/support/kbdoc/000185293 | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.dell.com/support/kbdoc/000185293 | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | idrac9_firmware | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dell:idrac9_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5E9ED974-1468-4B8B-B82E-5E0340C2601B",
"versionEndExcluding": "4.40.00.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.40.10.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected while generating a certificate. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application."
},
{
"lang": "es",
"value": "Dell EMC iDRAC9 versiones anteriores a 4.40.10.00, contienen m\u00faltiples vulnerabilidades de tipo cross-site scripting almacenado.\u0026#xa0;Un usuario malicioso autenticado remoto con altos privilegios podr\u00eda explotar estas vulnerabilidades para almacenar c\u00f3digo HTML o JavaScript malicioso por medio de m\u00faltiples afectaciones mientras genera un certificado.\u0026#xa0;Cuando los usuarios v\u00edctimas acceden a los datos enviados a trav\u00e9s de sus navegadores, el navegador web ejecuta el c\u00f3digo malicioso en el contexto de la aplicaci\u00f3n vulnerable."
}
],
"id": "CVE-2021-21542",
"lastModified": "2024-11-21T05:48:33.500",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.7,
"impactScore": 2.7,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.7,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-04-30T21:15:08.820",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-21541
Vulnerability from fkie_nvd - Published: 2021-04-30 21:15 - Updated: 2024-11-21 05:48
Severity ?
6.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
6.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
6.1 (Medium) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Summary
Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a DOM-based cross-site scripting vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or JavaScript code to DOM environment in the browser. The malicious code is then executed by the web browser in the context of the vulnerable web application.
References
| URL | Tags | ||
|---|---|---|---|
| security_alert@emc.com | https://www.dell.com/support/kbdoc/000185293 | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.dell.com/support/kbdoc/000185293 | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | idrac9_firmware | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dell:idrac9_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5E9ED974-1468-4B8B-B82E-5E0340C2601B",
"versionEndExcluding": "4.40.00.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a DOM-based cross-site scripting vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or JavaScript code to DOM environment in the browser. The malicious code is then executed by the web browser in the context of the vulnerable web application."
},
{
"lang": "es",
"value": "Dell EMC iDRAC9 versiones anteriores a 4.40.00.00, contiene una vulnerabilidad de tipo cross-site scripting basada en DOM.\u0026#xa0;Un atacante remoto no autenticado podr\u00eda explotar potencialmente esta vulnerabilidad enga\u00f1ando al usuario de la aplicaci\u00f3n v\u00edctima para que suministre un c\u00f3digo HTML o JavaScript malicioso al entorno DOM en el navegador.\u0026#xa0;A continuaci\u00f3n, el navegador web ejecuta el c\u00f3digo malicioso en el contexto de la aplicaci\u00f3n web vulnerable."
}
],
"id": "CVE-2021-21541",
"lastModified": "2024-11-21T05:48:33.383",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-04-30T21:15:08.780",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-21544
Vulnerability from fkie_nvd - Published: 2021-04-30 21:15 - Updated: 2024-11-21 05:48
Severity ?
2.7 (Low) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N
2.7 (Low) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N
2.7 (Low) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N
Summary
Dell EMC iDRAC9 versions prior to 4.40.00.00 contain an improper authentication vulnerability. A remote authenticated malicious user with high privileges could potentially exploit this vulnerability to manipulate the username field under the comment section and set the value to any user.
References
| URL | Tags | ||
|---|---|---|---|
| security_alert@emc.com | https://www.dell.com/support/kbdoc/000185293 | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.dell.com/support/kbdoc/000185293 | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | idrac9_firmware | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dell:idrac9_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5E9ED974-1468-4B8B-B82E-5E0340C2601B",
"versionEndExcluding": "4.40.00.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain an improper authentication vulnerability. A remote authenticated malicious user with high privileges could potentially exploit this vulnerability to manipulate the username field under the comment section and set the value to any user."
},
{
"lang": "es",
"value": "Dell EMC iDRAC9 versiones anteriores a 4.40.00.00, contiene una vulnerabilidad de autenticaci\u00f3n inapropiada.\u0026#xa0;Un usuario malicioso autenticado remoto con privilegios elevados podr\u00eda explotar potencialmente esta vulnerabilidad para manipular el campo username en la secci\u00f3n comment y establecer el valor para cualquier usuario."
}
],
"id": "CVE-2021-21544",
"lastModified": "2024-11-21T05:48:33.760",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 2.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 1.4,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 2.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 1.4,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-04-30T21:15:08.900",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-602"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-287"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2021-21543
Vulnerability from fkie_nvd - Published: 2021-04-30 21:15 - Updated: 2024-11-21 05:48
Severity ?
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
4.8 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Summary
Dell EMC iDRAC9 versions prior to 4.40.00.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected parameters. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application.
References
| URL | Tags | ||
|---|---|---|---|
| security_alert@emc.com | https://www.dell.com/support/kbdoc/000185293 | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.dell.com/support/kbdoc/000185293 | Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | idrac9_firmware | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dell:idrac9_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5E9ED974-1468-4B8B-B82E-5E0340C2601B",
"versionEndExcluding": "4.40.00.00",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected parameters. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application."
},
{
"lang": "es",
"value": "Dell EMC iDRAC9 versiones anteriores a 4.40.00.00, contienen m\u00faltiples vulnerabilidades de tipo cross-site scripting almacenado.\u0026#xa0;Un usuario malicioso autenticado remoto con privilegios elevados podr\u00eda explotar estas vulnerabilidades para almacenar c\u00f3digo HTML o JavaScript malicioso por medio de m\u00faltiples par\u00e1metros afectados.\u0026#xa0;Cuando los usuarios v\u00edctimas acceden a los datos enviados por medio de sus navegadores, el navegador web ejecuta el c\u00f3digo malicioso en el contexto de la aplicaci\u00f3n vulnerable."
}
],
"id": "CVE-2021-21543",
"lastModified": "2024-11-21T05:48:33.613",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.7,
"impactScore": 2.7,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 1.7,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-04-30T21:15:08.860",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-26198
Vulnerability from fkie_nvd - Published: 2020-12-16 16:15 - Updated: 2024-11-21 05:19
Severity ?
Summary
Dell EMC iDRAC9 versions prior to 4.32.10.00 and 4.40.00.00 contain a reflected cross-site scripting vulnerability in the iDRAC9 web application. A remote attacker could potentially exploit this vulnerability to run malicious HTML or JavaScript in a victim’s browser by tricking a victim in to following a specially crafted link.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | idrac9_firmware | * | |
| dell | idrac9_firmware | 4.40.00.00 | |
| dell | idrac9 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dell:idrac9_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "61EDDB16-D51C-440B-AEB5-3F087BC5E5A0",
"versionEndIncluding": "4.32.10.00",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:dell:idrac9_firmware:4.40.00.00:*:*:*:*:*:*:*",
"matchCriteriaId": "F478B785-B01A-4715-A2E0-ED239299BDE0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dell:idrac9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BD8B684E-092F-496C-9D94-51CCD1F3575A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.32.10.00 and 4.40.00.00 contain a reflected cross-site scripting vulnerability in the iDRAC9 web application. A remote attacker could potentially exploit this vulnerability to run malicious HTML or JavaScript in a victim\u2019s browser by tricking a victim in to following a specially crafted link."
},
{
"lang": "es",
"value": "Dell EMC iDRAC9 versiones anteriores a 4.32.10.00 y 4.40.00.00, contienen una vulnerabilidad de tipo cross-site scripting reflejada en la aplicaci\u00f3n web de iDRAC9.\u0026#xa0;Un atacante remoto podr\u00eda potencialmente explotar esta vulnerabilidad para ejecutar HTML o JavaScript maliciosos en el navegador de una v\u00edctima enga\u00f1\u00e1ndola para que siga un enlace especialmente dise\u00f1ado"
}
],
"id": "CVE-2020-26198",
"lastModified": "2024-11-21T05:19:30.567",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "security_alert@emc.com",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-12-16T16:15:13.883",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
FKIE_CVE-2020-5366
Vulnerability from fkie_nvd - Published: 2020-07-09 14:15 - Updated: 2024-11-21 05:34
Severity ?
7.1 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
6.5 (Medium) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Summary
Dell EMC iDRAC9 versions prior to 4.20.20.20 contain a Path Traversal Vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability by manipulating input parameters to gain unauthorized read access to the arbitrary files.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| dell | idrac9_firmware | * | |
| dell | idrac9 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:dell:idrac9_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1B64D591-31BA-4D2F-B5A4-00529C25EDC7",
"versionEndExcluding": "4.20.20.20",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:dell:idrac9:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BD8B684E-092F-496C-9D94-51CCD1F3575A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.20.20.20 contain a Path Traversal Vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability by manipulating input parameters to gain unauthorized read access to the arbitrary files."
},
{
"lang": "es",
"value": "Dell EMC iDRAC9 versiones anteriores a 4.20.20.20, contienen una vulnerabilidad de Salto de Ruta. Un usuario malicioso autenticado remoto con pocos privilegios podr\u00eda explotar esta vulnerabilidad al manipular los par\u00e1metros de entrada para conseguir acceso de lectura no autorizado a los archivos arbitrarios"
}
],
"id": "CVE-2020-5366",
"lastModified": "2024-11-21T05:34:00.527",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 4.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 4.2,
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-07-09T14:15:10.793",
"references": [
{
"source": "security_alert@emc.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/article/en-us/sln322125/dsa-2020-128-idrac-local-file-inclusion-vulnerability?lang=en"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.dell.com/support/article/en-us/sln322125/dsa-2020-128-idrac-local-file-inclusion-vulnerability?lang=en"
}
],
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "security_alert@emc.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2022-34435 (GCVE-0-2022-34435)
Vulnerability from cvelistv5 – Published: 2023-01-18 11:07 – Updated: 2025-04-03 19:43
VLAI?
Summary
Dell iDRAC9 version 6.00.02.00 and prior contain an improper input validation vulnerability in Racadm when the firmware lock-down configuration is set. A remote high privileged attacker could exploit this vulnerability to bypass the firmware lock-down configuration and perform a firmware update.
Severity ?
CWE
- CWE-20 - Improper Input Validation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller 9 |
Affected:
0 , ≤ 6.00.02.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:07:16.249Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000205346"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-34435",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-02T16:15:13.405834Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-03T19:43:41.022Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Integrated Dell Remote Access Controller 9",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "6.00.02.00",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-11-14T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cdiv\u003e\u003cdiv\u003eDell iDRAC9 version 6.00.02.00 and prior contain an improper input validation vulnerability in Racadm when the firmware lock-down configuration is set. A remote high privileged attacker could exploit this vulnerability to bypass the firmware lock-down configuration and perform a firmware update.\u003c/div\u003e\u003c/div\u003e\n\n"
}
],
"value": "\nDell iDRAC9 version 6.00.02.00 and prior contain an improper input validation vulnerability in Racadm when the firmware lock-down configuration is set. A remote high privileged attacker could exploit this vulnerability to bypass the firmware lock-down configuration and perform a firmware update.\n\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 2.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-18T11:07:45.399Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/000205346"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2022-34435",
"datePublished": "2023-01-18T11:07:45.399Z",
"dateReserved": "2022-06-23T18:55:17.120Z",
"dateUpdated": "2025-04-03T19:43:41.022Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21538 (GCVE-0-2021-21538)
Vulnerability from cvelistv5 – Published: 2021-07-29 15:55 – Updated: 2024-09-17 01:07
VLAI?
Summary
Dell EMC iDRAC9 versions 4.40.00.00 and later, but prior to 4.40.10.00, contain an improper authentication vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability to gain access to the virtual console.
Severity ?
9.6 (Critical)
CWE
- CWE-287 - Improper Authentication
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller (iDRAC) |
Affected:
unspecified , < 4.40.10.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:22.983Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000186420"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.40.10.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-05-10T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions 4.40.00.00 and later, but prior to 4.40.10.00, contain an improper authentication vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability to gain access to the virtual console."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287: Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-29T15:55:17",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/000186420"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-05-10",
"ID": "CVE-2021-21538",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.40.10.00"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC9 versions 4.40.00.00 and later, but prior to 4.40.10.00, contain an improper authentication vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability to gain access to the virtual console."
}
]
},
"impact": {
"cvss": {
"baseScore": 9.6,
"baseSeverity": "Critical",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287: Improper Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/000186420",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/000186420"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-21538",
"datePublished": "2021-07-29T15:55:17.320215Z",
"dateReserved": "2021-01-04T00:00:00",
"dateUpdated": "2024-09-17T01:07:08.122Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21544 (GCVE-0-2021-21544)
Vulnerability from cvelistv5 – Published: 2021-04-30 20:55 – Updated: 2024-09-17 03:28
VLAI?
Summary
Dell EMC iDRAC9 versions prior to 4.40.00.00 contain an improper authentication vulnerability. A remote authenticated malicious user with high privileges could potentially exploit this vulnerability to manipulate the username field under the comment section and set the value to any user.
Severity ?
CWE
- CWE-602 - Client-Side Enforcement of Server-Side Security
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller (iDRAC) |
Affected:
unspecified , < 4.40.00.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:22.987Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.40.00.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-04-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain an improper authentication vulnerability. A remote authenticated malicious user with high privileges could potentially exploit this vulnerability to manipulate the username field under the comment section and set the value to any user."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 2.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-602",
"description": "CWE-602: Client-Side Enforcement of Server-Side Security",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-30T20:55:21",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-04-14",
"ID": "CVE-2021-21544",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.40.00.00"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain an improper authentication vulnerability. A remote authenticated malicious user with high privileges could potentially exploit this vulnerability to manipulate the username field under the comment section and set the value to any user."
}
]
},
"impact": {
"cvss": {
"baseScore": 2.7,
"baseSeverity": "Low",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-602: Client-Side Enforcement of Server-Side Security"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/000185293",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/000185293"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-21544",
"datePublished": "2021-04-30T20:55:21.560938Z",
"dateReserved": "2021-01-04T00:00:00",
"dateUpdated": "2024-09-17T03:28:36.215Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21542 (GCVE-0-2021-21542)
Vulnerability from cvelistv5 – Published: 2021-04-30 20:55 – Updated: 2024-09-17 01:11
VLAI?
Summary
Dell EMC iDRAC9 versions prior to 4.40.10.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected while generating a certificate. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application.
Severity ?
4.8 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller (iDRAC) |
Affected:
unspecified , < 4.40.10.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:23.093Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.40.10.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-04-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.40.10.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected while generating a certificate. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-30T20:55:20",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-04-14",
"ID": "CVE-2021-21542",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.40.10.00"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC9 versions prior to 4.40.10.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected while generating a certificate. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application."
}
]
},
"impact": {
"cvss": {
"baseScore": 4.8,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/000185293",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/000185293"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-21542",
"datePublished": "2021-04-30T20:55:20.339400Z",
"dateReserved": "2021-01-04T00:00:00",
"dateUpdated": "2024-09-17T01:11:50.815Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21543 (GCVE-0-2021-21543)
Vulnerability from cvelistv5 – Published: 2021-04-30 20:55 – Updated: 2024-09-16 19:40
VLAI?
Summary
Dell EMC iDRAC9 versions prior to 4.40.00.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected parameters. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application.
Severity ?
4.8 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller (iDRAC) |
Affected:
unspecified , < 4.40.00.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:22.976Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.40.00.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-04-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected parameters. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-30T20:55:20",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-04-14",
"ID": "CVE-2021-21543",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.40.00.00"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected parameters. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application."
}
]
},
"impact": {
"cvss": {
"baseScore": 4.8,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/000185293",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/000185293"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-21543",
"datePublished": "2021-04-30T20:55:20.950938Z",
"dateReserved": "2021-01-04T00:00:00",
"dateUpdated": "2024-09-16T19:40:30.743Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21541 (GCVE-0-2021-21541)
Vulnerability from cvelistv5 – Published: 2021-04-30 20:55 – Updated: 2024-09-16 17:38
VLAI?
Summary
Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a DOM-based cross-site scripting vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or JavaScript code to DOM environment in the browser. The malicious code is then executed by the web browser in the context of the vulnerable web application.
Severity ?
6.1 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller (iDRAC) |
Affected:
unspecified , < 4.40.00.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:22.955Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.40.00.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-04-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a DOM-based cross-site scripting vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or JavaScript code to DOM environment in the browser. The malicious code is then executed by the web browser in the context of the vulnerable web application."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-30T20:55:19",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-04-14",
"ID": "CVE-2021-21541",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.40.00.00"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a DOM-based cross-site scripting vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or JavaScript code to DOM environment in the browser. The malicious code is then executed by the web browser in the context of the vulnerable web application."
}
]
},
"impact": {
"cvss": {
"baseScore": 6.1,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/000185293",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/000185293"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-21541",
"datePublished": "2021-04-30T20:55:19.672496Z",
"dateReserved": "2021-01-04T00:00:00",
"dateUpdated": "2024-09-16T17:38:25.537Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21540 (GCVE-0-2021-21540)
Vulnerability from cvelistv5 – Published: 2021-04-30 20:55 – Updated: 2024-09-16 20:01
VLAI?
Summary
Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a stack-based overflow vulnerability. A remote authenticated attacker could potentially exploit this vulnerability to overwrite configuration information by injecting arbitrarily large payload.
Severity ?
5.9 (Medium)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller (iDRAC) |
Affected:
unspecified , < 4.40.00.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:23.006Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.40.00.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-04-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a stack-based overflow vulnerability. A remote authenticated attacker could potentially exploit this vulnerability to overwrite configuration information by injecting arbitrarily large payload."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-30T20:55:18",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-04-14",
"ID": "CVE-2021-21540",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.40.00.00"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a stack-based overflow vulnerability. A remote authenticated attacker could potentially exploit this vulnerability to overwrite configuration information by injecting arbitrarily large payload."
}
]
},
"impact": {
"cvss": {
"baseScore": 5.9,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121: Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/000185293",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/000185293"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-21540",
"datePublished": "2021-04-30T20:55:19.049678Z",
"dateReserved": "2021-01-04T00:00:00",
"dateUpdated": "2024-09-16T20:01:18.387Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21539 (GCVE-0-2021-21539)
Vulnerability from cvelistv5 – Published: 2021-04-30 20:55 – Updated: 2024-09-16 16:58
VLAI?
Summary
Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a Time-of-check Time-of-use (TOCTOU) race condition vulnerability. A remote authenticated attacker could potentially exploit this vulnerability to gain elevated privileges when a user with higher privileges is simultaneously accessing iDRAC through the web interface.
Severity ?
5.9 (Medium)
CWE
- Other
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller (iDRAC) |
Affected:
unspecified , < 4.40.00.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:22.969Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.40.00.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-04-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a Time-of-check Time-of-use (TOCTOU) race condition vulnerability. A remote authenticated attacker could potentially exploit this vulnerability to gain elevated privileges when a user with higher privileges is simultaneously accessing iDRAC through the web interface."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:L/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Other",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-30T20:55:18",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-04-14",
"ID": "CVE-2021-21539",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.40.00.00"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a Time-of-check Time-of-use (TOCTOU) race condition vulnerability. A remote authenticated attacker could potentially exploit this vulnerability to gain elevated privileges when a user with higher privileges is simultaneously accessing iDRAC through the web interface."
}
]
},
"impact": {
"cvss": {
"baseScore": 5.9,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:L/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Other"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/000185293",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/000185293"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-21539",
"datePublished": "2021-04-30T20:55:18.417395Z",
"dateReserved": "2021-01-04T00:00:00",
"dateUpdated": "2024-09-16T16:58:47.474Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-26198 (GCVE-0-2020-26198)
Vulnerability from cvelistv5 – Published: 2020-12-16 15:50 – Updated: 2024-09-17 03:53
VLAI?
Summary
Dell EMC iDRAC9 versions prior to 4.32.10.00 and 4.40.00.00 contain a reflected cross-site scripting vulnerability in the iDRAC9 web application. A remote attacker could potentially exploit this vulnerability to run malicious HTML or JavaScript in a victim’s browser by tricking a victim in to following a specially crafted link.
Severity ?
6.1 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller (iDRAC) |
Affected:
unspecified , < 4.32.10.00 and 4.40.00.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:49:07.162Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.32.10.00 and 4.40.00.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-12-15T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.32.10.00 and 4.40.00.00 contain a reflected cross-site scripting vulnerability in the iDRAC9 web application. A remote attacker could potentially exploit this vulnerability to run malicious HTML or JavaScript in a victim\u2019s browser by tricking a victim in to following a specially crafted link."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-16T15:50:13",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2020-12-15",
"ID": "CVE-2020-26198",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.32.10.00 and 4.40.00.00"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC9 versions prior to 4.32.10.00 and 4.40.00.00 contain a reflected cross-site scripting vulnerability in the iDRAC9 web application. A remote attacker could potentially exploit this vulnerability to run malicious HTML or JavaScript in a victim\u2019s browser by tricking a victim in to following a specially crafted link."
}
]
},
"impact": {
"cvss": {
"baseScore": 6.1,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2020-26198",
"datePublished": "2020-12-16T15:50:13.965718Z",
"dateReserved": "2020-09-30T00:00:00",
"dateUpdated": "2024-09-17T03:53:53.693Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5366 (GCVE-0-2020-5366)
Vulnerability from cvelistv5 – Published: 2020-07-09 13:45 – Updated: 2024-09-16 17:29
VLAI?
Summary
Dell EMC iDRAC9 versions prior to 4.20.20.20 contain a Path Traversal Vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability by manipulating input parameters to gain unauthorized read access to the arbitrary files.
Severity ?
7.1 (High)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller (iDRAC) |
Affected:
unspecified , < 4.20.20.20
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:30:23.394Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/article/en-us/sln322125/dsa-2020-128-idrac-local-file-inclusion-vulnerability?lang=en"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.20.20.20",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-07-07T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.20.20.20 contain a Path Traversal Vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability by manipulating input parameters to gain unauthorized read access to the arbitrary files."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-09T13:45:13",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/article/en-us/sln322125/dsa-2020-128-idrac-local-file-inclusion-vulnerability?lang=en"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2020-07-07",
"ID": "CVE-2020-5366",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.20.20.20"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC9 versions prior to 4.20.20.20 contain a Path Traversal Vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability by manipulating input parameters to gain unauthorized read access to the arbitrary files."
}
]
},
"impact": {
"cvss": {
"baseScore": 7.1,
"baseSeverity": "High",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/article/en-us/sln322125/dsa-2020-128-idrac-local-file-inclusion-vulnerability?lang=en",
"refsource": "MISC",
"url": "https://www.dell.com/support/article/en-us/sln322125/dsa-2020-128-idrac-local-file-inclusion-vulnerability?lang=en"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2020-5366",
"datePublished": "2020-07-09T13:45:13.810635Z",
"dateReserved": "2020-01-03T00:00:00",
"dateUpdated": "2024-09-16T17:29:00.784Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-34435 (GCVE-0-2022-34435)
Vulnerability from nvd – Published: 2023-01-18 11:07 – Updated: 2025-04-03 19:43
VLAI?
Summary
Dell iDRAC9 version 6.00.02.00 and prior contain an improper input validation vulnerability in Racadm when the firmware lock-down configuration is set. A remote high privileged attacker could exploit this vulnerability to bypass the firmware lock-down configuration and perform a firmware update.
Severity ?
CWE
- CWE-20 - Improper Input Validation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller 9 |
Affected:
0 , ≤ 6.00.02.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T09:07:16.249Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000205346"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-34435",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-02T16:15:13.405834Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-03T19:43:41.022Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Integrated Dell Remote Access Controller 9",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "6.00.02.00",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-11-14T17:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cdiv\u003e\u003cdiv\u003eDell iDRAC9 version 6.00.02.00 and prior contain an improper input validation vulnerability in Racadm when the firmware lock-down configuration is set. A remote high privileged attacker could exploit this vulnerability to bypass the firmware lock-down configuration and perform a firmware update.\u003c/div\u003e\u003c/div\u003e\n\n"
}
],
"value": "\nDell iDRAC9 version 6.00.02.00 and prior contain an improper input validation vulnerability in Racadm when the firmware lock-down configuration is set. A remote high privileged attacker could exploit this vulnerability to bypass the firmware lock-down configuration and perform a firmware update.\n\n\n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 2.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20: Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-18T11:07:45.399Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/000205346"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2022-34435",
"datePublished": "2023-01-18T11:07:45.399Z",
"dateReserved": "2022-06-23T18:55:17.120Z",
"dateUpdated": "2025-04-03T19:43:41.022Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21538 (GCVE-0-2021-21538)
Vulnerability from nvd – Published: 2021-07-29 15:55 – Updated: 2024-09-17 01:07
VLAI?
Summary
Dell EMC iDRAC9 versions 4.40.00.00 and later, but prior to 4.40.10.00, contain an improper authentication vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability to gain access to the virtual console.
Severity ?
9.6 (Critical)
CWE
- CWE-287 - Improper Authentication
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller (iDRAC) |
Affected:
unspecified , < 4.40.10.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:22.983Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000186420"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.40.10.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-05-10T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions 4.40.00.00 and later, but prior to 4.40.10.00, contain an improper authentication vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability to gain access to the virtual console."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 9.6,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287: Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-29T15:55:17",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/000186420"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-05-10",
"ID": "CVE-2021-21538",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.40.10.00"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC9 versions 4.40.00.00 and later, but prior to 4.40.10.00, contain an improper authentication vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability to gain access to the virtual console."
}
]
},
"impact": {
"cvss": {
"baseScore": 9.6,
"baseSeverity": "Critical",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287: Improper Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/000186420",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/000186420"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-21538",
"datePublished": "2021-07-29T15:55:17.320215Z",
"dateReserved": "2021-01-04T00:00:00",
"dateUpdated": "2024-09-17T01:07:08.122Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21544 (GCVE-0-2021-21544)
Vulnerability from nvd – Published: 2021-04-30 20:55 – Updated: 2024-09-17 03:28
VLAI?
Summary
Dell EMC iDRAC9 versions prior to 4.40.00.00 contain an improper authentication vulnerability. A remote authenticated malicious user with high privileges could potentially exploit this vulnerability to manipulate the username field under the comment section and set the value to any user.
Severity ?
CWE
- CWE-602 - Client-Side Enforcement of Server-Side Security
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller (iDRAC) |
Affected:
unspecified , < 4.40.00.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:22.987Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.40.00.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-04-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain an improper authentication vulnerability. A remote authenticated malicious user with high privileges could potentially exploit this vulnerability to manipulate the username field under the comment section and set the value to any user."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 2.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-602",
"description": "CWE-602: Client-Side Enforcement of Server-Side Security",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-30T20:55:21",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-04-14",
"ID": "CVE-2021-21544",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.40.00.00"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain an improper authentication vulnerability. A remote authenticated malicious user with high privileges could potentially exploit this vulnerability to manipulate the username field under the comment section and set the value to any user."
}
]
},
"impact": {
"cvss": {
"baseScore": 2.7,
"baseSeverity": "Low",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-602: Client-Side Enforcement of Server-Side Security"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/000185293",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/000185293"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-21544",
"datePublished": "2021-04-30T20:55:21.560938Z",
"dateReserved": "2021-01-04T00:00:00",
"dateUpdated": "2024-09-17T03:28:36.215Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21542 (GCVE-0-2021-21542)
Vulnerability from nvd – Published: 2021-04-30 20:55 – Updated: 2024-09-17 01:11
VLAI?
Summary
Dell EMC iDRAC9 versions prior to 4.40.10.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected while generating a certificate. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application.
Severity ?
4.8 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller (iDRAC) |
Affected:
unspecified , < 4.40.10.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:23.093Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.40.10.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-04-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.40.10.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected while generating a certificate. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-30T20:55:20",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-04-14",
"ID": "CVE-2021-21542",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.40.10.00"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC9 versions prior to 4.40.10.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected while generating a certificate. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application."
}
]
},
"impact": {
"cvss": {
"baseScore": 4.8,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/000185293",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/000185293"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-21542",
"datePublished": "2021-04-30T20:55:20.339400Z",
"dateReserved": "2021-01-04T00:00:00",
"dateUpdated": "2024-09-17T01:11:50.815Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21543 (GCVE-0-2021-21543)
Vulnerability from nvd – Published: 2021-04-30 20:55 – Updated: 2024-09-16 19:40
VLAI?
Summary
Dell EMC iDRAC9 versions prior to 4.40.00.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected parameters. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application.
Severity ?
4.8 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller (iDRAC) |
Affected:
unspecified , < 4.40.00.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:22.976Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.40.00.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-04-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected parameters. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-30T20:55:20",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-04-14",
"ID": "CVE-2021-21543",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.40.00.00"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain multiple stored cross-site scripting vulnerabilities. A remote authenticated malicious user with high privileges could potentially exploit these vulnerabilities to store malicious HTML or JavaScript code through multiple affected parameters. When victim users access the submitted data through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable application."
}
]
},
"impact": {
"cvss": {
"baseScore": 4.8,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/000185293",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/000185293"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-21543",
"datePublished": "2021-04-30T20:55:20.950938Z",
"dateReserved": "2021-01-04T00:00:00",
"dateUpdated": "2024-09-16T19:40:30.743Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21541 (GCVE-0-2021-21541)
Vulnerability from nvd – Published: 2021-04-30 20:55 – Updated: 2024-09-16 17:38
VLAI?
Summary
Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a DOM-based cross-site scripting vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or JavaScript code to DOM environment in the browser. The malicious code is then executed by the web browser in the context of the vulnerable web application.
Severity ?
6.1 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller (iDRAC) |
Affected:
unspecified , < 4.40.00.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:22.955Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.40.00.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-04-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a DOM-based cross-site scripting vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or JavaScript code to DOM environment in the browser. The malicious code is then executed by the web browser in the context of the vulnerable web application."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-30T20:55:19",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-04-14",
"ID": "CVE-2021-21541",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.40.00.00"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a DOM-based cross-site scripting vulnerability. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or JavaScript code to DOM environment in the browser. The malicious code is then executed by the web browser in the context of the vulnerable web application."
}
]
},
"impact": {
"cvss": {
"baseScore": 6.1,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/000185293",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/000185293"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-21541",
"datePublished": "2021-04-30T20:55:19.672496Z",
"dateReserved": "2021-01-04T00:00:00",
"dateUpdated": "2024-09-16T17:38:25.537Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21540 (GCVE-0-2021-21540)
Vulnerability from nvd – Published: 2021-04-30 20:55 – Updated: 2024-09-16 20:01
VLAI?
Summary
Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a stack-based overflow vulnerability. A remote authenticated attacker could potentially exploit this vulnerability to overwrite configuration information by injecting arbitrarily large payload.
Severity ?
5.9 (Medium)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller (iDRAC) |
Affected:
unspecified , < 4.40.00.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:23.006Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.40.00.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-04-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a stack-based overflow vulnerability. A remote authenticated attacker could potentially exploit this vulnerability to overwrite configuration information by injecting arbitrarily large payload."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121: Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-30T20:55:18",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-04-14",
"ID": "CVE-2021-21540",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.40.00.00"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a stack-based overflow vulnerability. A remote authenticated attacker could potentially exploit this vulnerability to overwrite configuration information by injecting arbitrarily large payload."
}
]
},
"impact": {
"cvss": {
"baseScore": 5.9,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121: Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/000185293",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/000185293"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-21540",
"datePublished": "2021-04-30T20:55:19.049678Z",
"dateReserved": "2021-01-04T00:00:00",
"dateUpdated": "2024-09-16T20:01:18.387Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21539 (GCVE-0-2021-21539)
Vulnerability from nvd – Published: 2021-04-30 20:55 – Updated: 2024-09-16 16:58
VLAI?
Summary
Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a Time-of-check Time-of-use (TOCTOU) race condition vulnerability. A remote authenticated attacker could potentially exploit this vulnerability to gain elevated privileges when a user with higher privileges is simultaneously accessing iDRAC through the web interface.
Severity ?
5.9 (Medium)
CWE
- Other
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller (iDRAC) |
Affected:
unspecified , < 4.40.00.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:22.969Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.40.00.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-04-14T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a Time-of-check Time-of-use (TOCTOU) race condition vulnerability. A remote authenticated attacker could potentially exploit this vulnerability to gain elevated privileges when a user with higher privileges is simultaneously accessing iDRAC through the web interface."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:L/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Other",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-30T20:55:18",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/000185293"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-04-14",
"ID": "CVE-2021-21539",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.40.00.00"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a Time-of-check Time-of-use (TOCTOU) race condition vulnerability. A remote authenticated attacker could potentially exploit this vulnerability to gain elevated privileges when a user with higher privileges is simultaneously accessing iDRAC through the web interface."
}
]
},
"impact": {
"cvss": {
"baseScore": 5.9,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:L/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Other"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/000185293",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/000185293"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-21539",
"datePublished": "2021-04-30T20:55:18.417395Z",
"dateReserved": "2021-01-04T00:00:00",
"dateUpdated": "2024-09-16T16:58:47.474Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-26198 (GCVE-0-2020-26198)
Vulnerability from nvd – Published: 2020-12-16 15:50 – Updated: 2024-09-17 03:53
VLAI?
Summary
Dell EMC iDRAC9 versions prior to 4.32.10.00 and 4.40.00.00 contain a reflected cross-site scripting vulnerability in the iDRAC9 web application. A remote attacker could potentially exploit this vulnerability to run malicious HTML or JavaScript in a victim’s browser by tricking a victim in to following a specially crafted link.
Severity ?
6.1 (Medium)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller (iDRAC) |
Affected:
unspecified , < 4.32.10.00 and 4.40.00.00
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:49:07.162Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.32.10.00 and 4.40.00.00",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-12-15T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.32.10.00 and 4.40.00.00 contain a reflected cross-site scripting vulnerability in the iDRAC9 web application. A remote attacker could potentially exploit this vulnerability to run malicious HTML or JavaScript in a victim\u2019s browser by tricking a victim in to following a specially crafted link."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-16T15:50:13",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2020-12-15",
"ID": "CVE-2020-26198",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.32.10.00 and 4.40.00.00"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC9 versions prior to 4.32.10.00 and 4.40.00.00 contain a reflected cross-site scripting vulnerability in the iDRAC9 web application. A remote attacker could potentially exploit this vulnerability to run malicious HTML or JavaScript in a victim\u2019s browser by tricking a victim in to following a specially crafted link."
}
]
},
"impact": {
"cvss": {
"baseScore": 6.1,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/en-us/000181088/dsa-2020-268-dell-emc-idrac9-reflected-xss-vulnerability"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2020-26198",
"datePublished": "2020-12-16T15:50:13.965718Z",
"dateReserved": "2020-09-30T00:00:00",
"dateUpdated": "2024-09-17T03:53:53.693Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-5366 (GCVE-0-2020-5366)
Vulnerability from nvd – Published: 2020-07-09 13:45 – Updated: 2024-09-16 17:29
VLAI?
Summary
Dell EMC iDRAC9 versions prior to 4.20.20.20 contain a Path Traversal Vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability by manipulating input parameters to gain unauthorized read access to the arbitrary files.
Severity ?
7.1 (High)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Dell Remote Access Controller (iDRAC) |
Affected:
unspecified , < 4.20.20.20
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T08:30:23.394Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/article/en-us/sln322125/dsa-2020-128-idrac-local-file-inclusion-vulnerability?lang=en"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Dell Remote Access Controller (iDRAC)",
"vendor": "Dell",
"versions": [
{
"lessThan": "4.20.20.20",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-07-07T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC iDRAC9 versions prior to 4.20.20.20 contain a Path Traversal Vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability by manipulating input parameters to gain unauthorized read access to the arbitrary files."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-09T13:45:13",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/article/en-us/sln322125/dsa-2020-128-idrac-local-file-inclusion-vulnerability?lang=en"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2020-07-07",
"ID": "CVE-2020-5366",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Dell Remote Access Controller (iDRAC)",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "4.20.20.20"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC iDRAC9 versions prior to 4.20.20.20 contain a Path Traversal Vulnerability. A remote authenticated malicious user with low privileges could potentially exploit this vulnerability by manipulating input parameters to gain unauthorized read access to the arbitrary files."
}
]
},
"impact": {
"cvss": {
"baseScore": 7.1,
"baseSeverity": "High",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/article/en-us/sln322125/dsa-2020-128-idrac-local-file-inclusion-vulnerability?lang=en",
"refsource": "MISC",
"url": "https://www.dell.com/support/article/en-us/sln322125/dsa-2020-128-idrac-local-file-inclusion-vulnerability?lang=en"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2020-5366",
"datePublished": "2020-07-09T13:45:13.810635Z",
"dateReserved": "2020-01-03T00:00:00",
"dateUpdated": "2024-09-16T17:29:00.784Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}